• Title/Summary/Keyword: X-ray Imaging System

Search Result 290, Processing Time 0.026 seconds

Discrimination for Line-clustering Segmental Approach to Steel-tube X-ray Image (경사조사(傾斜照射) 강판튜브 방사선영상 영역특성 분석)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.399-400
    • /
    • 2007
  • This paper proposes an regional analytic approach in image data space for radiographic image. Image is segmented into four regions, such as background, thickness, weld area and tube area, due to directional properties. Each region has its own gray level distribution, contrast range and noise property, originated from X-ray project mechanism and electric control system itself. Projection incorrectness and noise influence included on imaging quality is analyzed functionally and statistically. The experimental results shows not only segmental effects, but also visual edge evaluation.

  • PDF

Investigations on borate glasses within SBC-Bx system for gamma-ray shielding applications

  • Rammah, Y.S.;Tekin, H.O.;Sriwunkum, C.;Olarinoye, I.;Alalawi, Amani;Al-Buriahi, M.S.;Nutaro, T.;Tonguc, Baris T.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.282-293
    • /
    • 2021
  • This paper examines gamma-ray shielding properties of SBC-Bx glass system with the chemical composition of 40SiO2-10B2O3-xBaO-(45-x)CaO- yZnO- zMgO (where x = 0, 10, 20, 30, and 35 mol% and y = z = 6 mol%). Mass attenuation coefficient (µ/ρ) which is an essential parameter to study gamma-ray shielding properties was obtained in the photon energy range of 0.015-15 MeV using PHITS Monte Carlo code for the proposed glasses. The obtained results were compared with those calculated by WinXCOM program. Both the values of PHITS code and WinXCOM program were observed in very good agreement. The (µ/ρ values were then used to derive mean free path (MFP), electron density (Neff), effective atomic number (Zeff), and half value layer (HVL) for all the glasses involved. Additionally, G-P method was employed to estimate exposure buildup factor (EBF) for each glass in the energy range of 0.015-15 MeV up to penetration depths of 40 mfp. The results reveal that gamma-ray shielding effectiveness of the SBC-Bx glasses evolves with increasing BaO content in the glass sample. Such that SBC-B35 glass has superior shielding capacity against gamma-rays among the studied glasses. Gamma-ray shielding properties of SBC-B35 glass were compared with different conventional shielding materials, commercial glasses, and newly developed HMO glasse. Therefore, the investigated glasses have potential uses in gamma shielding applications.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

A study on the development of the computerized imaging system for diagnosis and treatment plannig of orthodontics and orthognathic surgery (치아교정과 턱수술용 컴퓨터 영상분석 및 진단 시스템 개발에 관한 연구)

  • Kim, J.H.;Kim, D.Y.;Lee, W.Y.;Ha, E.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.275-276
    • /
    • 1998
  • In this paper, we present the software on the development of the computerized imaging system for diagnosis and treatment plannig of orthodontics and orthognathic surgery. Soft tissue changes followed by orthognathic surgery mainly depends on surgical movements of hard tissue. Then, the stepwise multiple regression method was used to investigate the soft tissue changes followed by hard tissue changes. As a result of this research, we were able to develop a system which diagnoses automatic X-ray images and predicts soft tissue changes after othognathic surgery.

  • PDF

An Accuracy Evaluation on Convolutional Neural Network Assessment of Orientation Reversal of Chest X-ray Image (흉부 방사선영상의 좌, 우 반전 발생 여부 컨벌루션 신경망 기반 정확도 평가)

  • Lee, Hyun-Woo;Oh, Joo-Young;Lee, Joo-Young;Lee, Tae-Soo;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.65-70
    • /
    • 2020
  • PA(postero-anterior) and AP(antero-posterior) chest projections are the most sought-after types of all kinds of projections. But if a radiological technologist puts wrong information about the position in the computer, the orientation of left and right side of an image would be reversed. In order to solve this problem, we utilized CNN(convolutional neural network) which has recently utilized a lot for studies of medical imaging technology and rule-based system. 70% of 111,622 chest images were used for training, 20% of them were used for testing and 10% of them were used for validation set in the CNN experiment. The same amount of images which were used for testing in the CNN experiment were used in rule-based system. Python 3.7 version and Tensorflow r1.14 were utilized for data environment. As a result, rule-based system had 66% accuracy on evaluating whether the orientation reversal on chest x-ray image. But the CNN had 97.9% accuracy on that. Being overcome limitations by CNN which had been shown on rule-based system and shown the high accuracy can be considered as a meaningful result. If some problems which can occur for tasks of the radiological technologist can be separated by utilizing CNN, It can contribute a lot to optimize workflow.

Time-Phased Implementation of a Large-Scale PACS at Samsung Medical Center

  • Ro, Duk-Woo;Choi, Hyung-Sik;Lim, Jae-Hoon;Kim, Won-Ki
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.26-27
    • /
    • 1994
  • The first step implementation of a hospital-wide Picture Archiving Communications System (PACS) at a newly built hospital Samsung Medical Center (SMC), is described. Current clinical operation encompasses the fiber optics delivery of direct-interfaced magnetic resonance imager (LRI), X-ray computed tomography (CT). digital subtraction angiography (DSA) and computed radiography (CR) digital images via high performance file server to the departments of radiology, neurosurgery, orthopedics surgery, neurology, emergency room and the surgical intensive care unit.

  • PDF

Analysis of the Influence of Examination Gowns on the Image and the Suitable Fabrics for Chest AP Examinations on DR X-ray Systems (디지털 X-선 시스템에서 흉부 전·후 방향 검사 시 검사복이 영상에 미치는 영향과 적정 검사복 원단의 분석)

  • Eun-Bi Baek;Yoo-Jin Jeong;Su-Bin Lim;Sang-Jo Park;Yeong-Cheol Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.865-872
    • /
    • 2023
  • The purpose of this study was to analyze fabrics suitable for use as examination gowns to determine whether examination gowns affect imaging during anterior to posterior chest examinations(Chest AP) on a digital X-ray system. Examination gowns in use at five medical centers in Seoul were collected and included modal, tencel, cotton, and rayon fabrics. The selection of fabrics was based on studies that reported fabrics with good tactile, absorbent, stretchable, and wrinkle resistance. Phantoms of five hospital gowns and four fabrics, arranged in overlapping layers from one to eight, were created and examined on a digital X-ray system in both Chest AP examination. The images examined were subjected to a first-step profile analysis, a second-step signal intensity averaging analysis, and a third-step microscopic analysis. The results showed that all nine materials had an increasing impact on the image as the number of layers of fabric increased, with the modal fabric having the least impact on the image in the first, second, and third analyses. In conclusion, as the resolution of digital x-ray systems increases, the impact of examination clothing on the image will increase, and research to find suitable materials for examination clothing will continue to be necessary.

Investigation of Near Infrared Radiation Based Screening for Video-Fluoroscopy Swallowing Studies (비디오투시연하검사 스크리닝을 위한 근적외선 기술 조사)

  • Park, Ji-Su;Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • With the recent advances in radiological science, there was radiographic techniques development and several researches to diagnosing dysphagia. We proposed the new Imaging technology based on Near Infrared radiation (NIR) for video fluoroscopic swallowing study (VFSS). To reduce the risk of the VFSS examination for swallowing rehabilitation, multi-NIR camera system comprised. Based on the multi-NIR camera imaging system, Computational simulation was conducted to identify the potential of the multi-NIR camera imaging system as a clinical tool (screening system). As a result of the simulation applied in this study, the proposed system has a potential to be a clinical solution although there is a few of limitations. we believe that it will be a good tool to support the VFSS as a screening technology in clinical fields.

Conversion of Radiology Report into DICOM SR (의료 영상 판독 결과의 DICOM SR 변환)

  • Kim Yong-Soo;Shin Seung-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.3 s.35
    • /
    • pp.331-337
    • /
    • 2005
  • 'Supplement 23:DICOM SR' announced on April 2000 made possible co-relations between the clinical reports and human body parts by standardizing the exchange of clinical information. DICOM SR uses its own coding schemes and values to represent information, which convey hierarchically structured content items. This paper analyzes radiology reports produced in HIS(Hospital Information System) and categorizes content structures into three parts such as, finding, conclusion, and recommendation, and implements a system which can be used by clinicians. Digital X-ray images and their reports have been managed separately. Since the report made by DICOM SR can refer to images, the integrated information of reports and images is possible.

  • PDF

Gaussian apodization and superresolution optical imaging system for soft X-ray region (Gaussian Apodization이 되어 있는 X-선 결상계의 초분해능)

  • 송영란;이민희;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.89-95
    • /
    • 1996
  • Superresolution optics, employing Gaussian apodization, is rigorously treated at the soft X-ray wave-length(λ=0.013 ${\mu}{\textrm}{m}$) region. In the diffraction integral, the line integral along the imaginary axis is found small, and it is ignored, so that the diffraction integral consists of the integration along the real axis. The resolution of the diffracted image is not effected by the pupil angular frequency bandwidth $2{\omega}_0$, which is one of the most important the characteristic features of Gaussian apodization ($e^{-o^2x^2}$ optics. The superresolution optics has resolution ($\frac{1}{2}{\times}FWHM)$=$\Delta$x=0.008 $\mu$m which is smaller than the Rayleigh criterion of 2λ=0.026 ${\mu}{\textrm}{m}$ for NA=0.25. The optical system has ${\omega}_0{\ge}\frac{1}{2}{\sigma}$, which gives the peak intensity of the diffracted image larger than $e^{-2}$ times intensity obtainable by the infinite sperture.

  • PDF