• Title/Summary/Keyword: X-ray Fluorescence

Search Result 415, Processing Time 0.024 seconds

Identification of the geographical origin of cheonggukjang by using fourier transform near-infrared spectroscopy and energy dispersive X-ray fluorescence spectrometry (근적외선분광분석기 및 에너지 분산형 X선 형광분석기를 이용한 청국장 원산지 판별)

  • Kang, Dong-Jin;Moon, Ji-Young;Lee, Dong-Gil;Lee, Seong-Hun
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.418-423
    • /
    • 2016
  • This study was conducted to identify the geographical origin of soybeans in Cheonggukjang by analyzing its organic components and inorganic elements with Fourier transform near-infrared spectroscopy (FT-NIRS) and with energy dispersive X-ray fluorescence (ED-XRF) coupled with multivariate statistical analysis. For method development, 280 samples from various regions were collected and analyzed. The discriminant accuracy for the developed methods was 97.5% for FT-NIRS and 98.0% for ED-XRF with multivariate statistical analysis. A validation test confirmed the discriminant accuracy to be 96.3% for FT-NIRS and 95.0% for ED-XRF. Overall, the results showed that methods using FT-NIRS and ED-XRF could be used to identify the geographical origin of Cheonggukjang.

A study on development of CRM by means of XRF analysis for fine ceramic ($BaTiO_3$) (티탄산바륨 소재의 XRF 분석용 CRM 개발에 관한 연구)

  • Kim, Young Man;Jeong, Chan Yee;Lim, Chang Ho;Song, Taek Yong;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.382-391
    • /
    • 1996
  • In this study, 12 different chemical species of fine ceramic($BaTiO_3$) were synthesized as the standard materials for the fast and accurate measurements of X-ray fluorescence spectrometry. Samples were diluted to sixteen times with the filling compound ($Li_2B_4O_7+LiBO_2$) in order to remove the matrix effect, and to get the convenient storage and homogeneity of ingredients. The matrix effects among the ingredients were corrected by the empirical coefficient method based on the Lucas-Tooth and Price model. The standard curve on 12 standard materials containing 15 elements were obtained by using X-ray fluorescence spectrometry at three different laboratories. The correlation factors of BaO, PbO, SrO, $Fe_2O_3$, $La_2O_3$, $SnO_2$, ZnO, $ZrO_2$, CaO indicated the relati vely good agreement over 0.995 among the three different laboratories. $SiO_2$ and $Al_2O_3$ showed the poor linearity because of their low fluorescence intensities.

  • PDF

Generalized Two-dimensional (2D) Correlation Spectroscopy: Principle and Its Applications (일반화된 이차원 상관 분광학: 원리 및 응용)

  • Young Mee Jung;Seung Bin Kim
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.5
    • /
    • pp.447-459
    • /
    • 2003
  • Generalized 2D correlation spectroscopy has been applied extensively to the analysis of spectral data sets obtained during the observation of a system under some external perturbation. It is used in various fields of spectroscopy including IR, Raman, UV, fluorescence, X-ray diffraction, and X-ray absorption spectroscopy (XAS) as well as chromatography. 2D hetero-spectral correlation analysis compares two completely different types of spectra obtained for a system under the same perturbation. Because of the wide range of applications of this technique, it has become one of the standard analytical techniques for the analytical chemistry, physical chemistry, biochemistry, and so on, and for studies of polymers, biomolecules, nanomaterials, etc. In this paper, we will introduce the principle of generalized 2D correlation spectroscopy and its applications that we have studied.

Dyeing of Cotton Fabrics with Loess Using Soybean Milk - The Compositions of Loess Deposited on the Cotton Fabrics - (콩즙을 이용한 면직물의 황토염색 -면직물에 부착된 황토의 성분분석을 중심으로-)

  • Kim, Soo-Jung;Ryu, Hyo-Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.10
    • /
    • pp.1770-1778
    • /
    • 2001
  • 황토는 대표적인 천연 무기염재의 일종으로서 바람에 의해 운반되어 퇴적된 담황색 내지는 황회색을 띠는 실트질의 퇴적물을 일컫는다. 황토의 구성물질은 주로 석영, 장석, 산화철광물, 깁사이트 등의 여러 가지 점토광물을 포함하는데, 주로 적색을 띠는 것은 소량의 산화철 광물에 기인되는 경우가 많으며 황토를 구성하는 점토광물로는 버미큘라이트, 카오린 광물인 캐올리나이트와 할로이사이트, 일라이트 등이 있다. 본 연구에서는 면직물에 천연 무기염재인 황토를 사용한 염색시에 황토 단독염색과 콩즙 전처리 후 황토염색으로 나누어 염색을 실시하고, 원료 황토와 황토염색 후 면직물에 부착된 성분 간에 차이가 있는지를 확인하기 위해 X선 형광분석(X-ray fluorescence analysis, XRF)을 이용하여 염색 전.후 황토의 성분을 분석하였고, X선 회절분석(X-ray diffraction analysis, XRD)을 이용하여 황토 및 염색 전 후 면직물에 부착된 광물질의 주성분을 분석하였으며, energy dispersive spectrometer (EDS)가 장착된 주사전자현미경을 이용하여 면직물에 부착된 광물의 성분을 조사하였다. 그 결과, 황토로 면직물을 염색하는 경우 면직물에 부착되는 황토의 양과 K/S 값은 거 의 비례하여 증가하는 것으로 나타났다. 황토 염색 후 면직물에 부탁되는 주성분은 주로 SiO$_2$, A1$_2$O$_3$, Fe$_2$O$_3$등인 것으로 나타났으며, X선 회절분석과 EDS분석에 의해 캐올리나이트, 일라이트 등의 점토광물의 형태로 존재하는 것이 확인되었다.

  • PDF

Preparation and Structure Properties of LaBa2Cu2O9, LaBa22CaCu3O12 and LaBa2Ca2Cu5O15 Perovskites

  • Kareem Ali Jasim;Hind Abdulmajeed Mahdi;Rafah Ismael Noori;Marwa Ayad Abdulmajeed
    • Korean Journal of Materials Research
    • /
    • v.33 no.9
    • /
    • pp.367-371
    • /
    • 2023
  • In this study we examine variations in the structure of perovskite compounds of LaBa2Cu2O9, LaBa22CaCu3O12 and LaBa2Ca2Cu5O15 synthesized using the solid state reaction method. The samples' compositions were assessed using X-ray fluorescence (XRF) analysis. The La: Ba: Ca: Cu ratios for samples LaBa2Cu2O9, LaBa22CaCu3O12 and LaBa2Ca2Cu5O15 were found by XRF analysis to be around 1:2:0:2, 1:2:1:3, and 1:2:2:5, respectively. The samples' well-known structures were then analyzed using X-ray diffraction. The three samples largely consist of phases 1202, 1213, and 1225, with a trace quantity of an unknown secondary phase, based on the intensities and locations of the diffraction peaks. According to the measured parameters a, b, and c, every sample has a tetragonal symmetry structure. Each sample's mass density was observed to alter as the lead oxide content rose. Scanning electron microscope (SEM) images of the three phases revealed that different Ca-O and Cu-O layers can cause different grain sizes, characterized by elongated thin grains, without a preferred orientation.

Quantitative Analysis of X-Ray Fluorescence for Understanding the Effect of Elevated Temperatures on Cement Pastes (XRF (X-ray fluorescence)를 활용한 고온환경에 노출된 시멘트 페이스트 분석의 이해)

  • Kil-Song Jeon;Young-Sun Heo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.130-137
    • /
    • 2023
  • By using XRF (X-ray fluorescence), this study investigates the variation of chemical properties in cement pastes at elevated temperatures. High-temperature conditions were prepared by using an electric furnace, planning a total of 11 target temperatures ranging from room temperature to 1000 ℃. A standard library of geo-quant basic was applied for the analysis of 12 elements in cement paste, including Ca, Si, Al, Fe, S, Mg, Ti, Sr, P, Mn, Zn and K. The results revealed that, as the temperature increased, the proportion of each element in the cement paste also increased. With the exception of a few elements present in extremely low amounts in the cement pastes, the variation in the composition ratio of most elements exhibited a strong correlation with temperature, with an R-squared value exceeding 0.98. In this study, cement pastes exposed to normal and high-temperature environments were compared. The authors established that the reasons for the different results in this comparison can be explained from the same perspective as when comparing raw cement with cement paste. Furthermore, this study discussed the potentially most dominant parameter when investigating the properties of cement paste using XRF.

Studies on X-Ray Fluorescence Analysis of Sulfide Ores by Solution Technique (I). Analysis of Sulfur (용액법을 이용한 황화광석의 X-선 형광분석에 관한 연구 (제1보). 황의 분석)

  • Young-Sang Kim;Kee-Chae Park
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.229-234
    • /
    • 1982
  • Using solution technique, sulfur in the sulfide ore was indirectly determined by X-ray fluorescence spectrometry. The sample was dissolved with the mixed solution of B$r_2$ and HN$O_3$, and Si$O_2$, a major constituent, was repelled from the solution by HF treatment several times, B$a^{2+}$ solution was added to the solution to precipitate the S$O^4_{2-}$ ion as BaS$O_4$. Measuring the fluorescent X-ray intensity of excess Ba2+ ion in the filtrate, the content of sulfur in the original ore was back-calculated. Comparing the results by this method with the gravimetric method, the mean difference was ${\pm}1.7%$ in the range of 20 to 40% of sulfur content and the method was tolerably reproducible.

  • PDF

An Efficient Background Modeling and Correction Method for EDXRF Spectra (EDXRF 스펙트럼을 위한 효율적인 배경 모델링과 보정 방법)

  • Park, Dong Sun;Jagadeesan, Sukanya;Jin, Moonyong;Yoon, Sook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.238-244
    • /
    • 2013
  • In energy dispersive X-ray fluorescence analysis, the removal of the continuum on which the X-ray spectrum is superimposed is one of the most important processes, since it has a strong influence on the analysis result. The existing methods which have been used for it usually require tight constraints or prior information on the continuum. In this paper, an efficient background correction method is proposed for Energy Dispersive X-ray fluorescence (EDXRF) spectra. The proposed method has two steps of background modeling and background correction. It is based on the basic concept which differentiates background areas from the peak areas in a spectrum and the SNIP algorithm, one of the popular methods for background removal, is used to enhance the performance. After detecting some points which belong to the background from a spectrum, its background is modeled by a curve fitting method based on them. And then the obtained background model is subtracted from the raw spectrum. The method has been shown to give better results than some of traditional methods, while working under relatively weak constraints or prior information.

A Study on X-Ray Fluorescence Analysis of Ta$_2O_5,\;Nb_2O_5,\;SnO_2$ and ZrO$_2$ in Tin-slag Samples (희석 파라미터법에 의한 주석슬랙중 Ta$_2O_5,\;Nb_2O_5,\;SnO_2$ 및 ZrO$_2$의 X-선형광분석에 관한 연구)

  • Young Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.265-270
    • /
    • 1985
  • Ta$_2$O$_5$, Nb$_2$O$_5$, SnO$_2$ and ZrO$_2$ in tin-slag samples were determined by X-ray fluorescence spectrometry using the dilution parameter method and the analytical results were compared with the data obtained by standard calibration curve method. Tin-slag samples and one standard sample having very similar composition to the tin-slags were diluted with a proper diluent (La$_2$O$_3$) to the ratio of 1: 1, 1 : 2, 1 : 3 and 1 : 4. After measuring the X-ray intensities of original and diluted samples, the values of dilution parameters were calculated by using the dilution parameter equation. Without any calibration curve, the analytical results were calculated from the equation including the dilution parameter term. The results were in good agreement with the reference data by the standard calibration curve method.

  • PDF

A design of transmission-type multi-target X-ray tube based on electric field modulation

  • Zhao, Lei;Jia, Wenbao;Jin, Limin;Shan, Qing;Cheng, Can;Zhu, Hongkui;Hei, Daqian
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3026-3034
    • /
    • 2021
  • Multi-target X-ray tube is a new type X-ray source, and can be applied in many fields such as sensitive X-ray fluorescence analysis and medical imaging. In this work, we report an electric field modulation multi-target X-ray tube, which contains four targets (Cr, Ni, Au, Mo) coated on a Beryllium (Be) window. A four-valve electric field deflector was developed to deflect the electron beam to bombard the corresponding targets. Particle dynamics analysis software was employed to simulate the particle tracking of electron beam. The results show that the 30 keV electron beam could get a 6.7 mm displacement on the target plane by 105 V/m electric field. The focus areas are about 2 mm × 5 mm and 4 mm × 2.5 mm after deflection in two directions. Thermal behavior calculated by ANSYS shows that the designed target assembly could withstand a 10 W continuous power. The optimum target thicknesses and emission spectra were obtained by Geant4 when the thickness of Be window was 300 mm and the electron beam incident angle was 0.141 rad. The results indicate that this multi-target X-ray tube could provide different X-ray sources effectively.