• Title/Summary/Keyword: X-ray Fluorescence

Search Result 415, Processing Time 0.031 seconds

Determination of Trace Elements in Atmospheric Dust by X-Ray Fluorescence Spectrometry(II) : X-ray Fluorescence Spectrometric Determination of Light Elements (형광 X선에 의한 대기분진중의 미량성분의 측정(II): 대기부유분진 중 경원소의 X-선 형광분석)

  • 이용근;박현미;이동수;이보경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.247-254
    • /
    • 1993
  • A simple and direct method is developed for the determination of light Elements in atmospheric particulates by X-ray fluorescence spectrometry. Calibration standards for the light elements such as Al, Mg, K, Ca, etc are prepared by filtering real atmospheric particulates over variable time and subsequently standardizing them by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) or Atomic Absorption Spectrophotometry(AAS) analysis. The validity of this calibration method is tested by analyzing more than 100 aerosol samples, collected at urban(Seoul) and rural(Padori) sites over a two year period with this method and then comparing them with those by other accuracy proven methods such as AAS or ICP-MS: for all metals tested the results showed reasonably good agreements (R $\geq$ 0.95).

  • PDF

Improvement of detection sensitivity of impurities on Si wafer surface using synchrotron radiation (방사광을 이용한 Si 웨이퍼 표면불순물 검출감도 향상)

  • 김흥락;김광일;강성건;김동수;윤화식;류근걸;김영주
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.1
    • /
    • pp.13-19
    • /
    • 1999
  • Total reflection X-ray fluorescence spectroscopy using synchrotron radiation source called as TRSFA was explored to achieve high sensitivities to impurity metals on Si wafer surface. It consists of monochromating part to select a specific wavelength, slit part to shield direct beam and to control monochromated beam, and main chamber to dectect fluorescent X-ray counts of impurities on si wafer. Monochromated X-ray of 10.90 KeV was selected and the optimum total reflection condition on silicon wafer was obtained through tuning the dead time and fluorescent X-ray count of Si and Fe. TRSFA system could increase the sensitivity as high as 50 times in comparision with TRXFA using normal X-ray source. But the trend was varied since the surface conditions of Si wafers and, therefore, the reflectivities were different. Furthemore, there seems to be a promising path to reaching a detection limit useful to the next generation metal impurities control, because Fe impurity below to the $5\times10^{9}\textrm{atomas/cm}^2$ can be detectable through the developed TRSFA system.

  • PDF

Comparative Studies on the Discrimination of Angelicae Gigantis Radix by Near-infrared Spectroscopy, Electronic Nose and X-ray Fluorescence Spectrometry (근적외선분광법, 전자코 및 엑스선형광법을 이용한 당귀의 기원판별법 비교 연구)

  • 조창희;김수정;김효진
    • YAKHAK HOEJI
    • /
    • v.46 no.3
    • /
    • pp.161-167
    • /
    • 2002
  • Angelicae gigantis radix is the root of the perennial plant, which belongs to the family Umbelliferae. However, this herbal drug is represented quite different chemical components according to its different genus name, though other herbal drugs (i.e. Leonuri Herba, Xanthii Fructus and so on) show similar constituents on the same name. The root of Angelica gigas containing the coumarin compounds is commonly used in Korea, while Angelica sinensis and Angelica acutiloba including phthalide compounds are used in China and Japan, respectively as Angelicae gigantis radix. In this paper, a nearinfrared spectroscopic method was developed to determine genus name of Angelica spp., especially A. gigas and A. sinensis which are commonly misused in herbal markets. X-ray fluorescence spectrometry and electronic nose have been also applied as nondestructive methods to discriminate A. gigas from A. sinensis according to their specific properties.

Fabrication of X-ray monocapillary optics for soft X-ray fluorescence analysis (경 X선 형광분석을 위한 모세관 광학소자 제작)

  • Cho, Hyung-Wook;Park, Byung-Hoon;Kim, Yong-Min;Choi, Chul-Hee;Choi, Seong-Hee;Kim, Ki-Hong;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.409-413
    • /
    • 2011
  • An X-ray tube used an X-ray fluorescence analysis system has a low X-ray photon intensity which results in reducing measurement accuracy and increasing exposure time. These shortages can be overcame by using a monocapillary optics. A monocapillary optics was optimally designed for focusing the characteristic X-ray of tungsten (8.4 keV). The monocapillary optics can achieve a gain of 10 at the least. The monocapillary optics was fabricated by using puller and pyrex glass, raw material. In fabrication, a weigh of 45g and a temperature of $650^{\circ}$ was loaded. The total fabrication time was 460 minutes. The fabricated capillary had 87 mm in length and maximum diameter of 300 ${\mu}m$ and minimum diameter of 192 ${\mu}m$. When the fabricated monocapillary optics is applied to an X-ray fluorescence analysis system, the detection accuracy for soft elements, for example sulfur (S), will be improved.

A Study on the On-site Flame Resistant Inspection Method by X-ray Fluorescence Spectrometer (X-선 형광분석기를 이용한 현장방염검사방법에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.124-129
    • /
    • 2016
  • According to the current law, on-site flame resistant-treated interior decorations should pass the flame resistant performance test through a 45 degree combustion test from the district fire department. Although a 45 degree combustion test is the most accurate method for determining the flame resistant performance, it can be unreliable when tested on unauthorized samples. To avoid unauthorized sampling, this study suggests on-site flame resistant inspection by X-ray fluorescence spectrometer. Ten types of flame resistant paint were spread on plywoods and MDFs and the components were analyzed by X-ray fluorescence spectrometer. As a result, due to a difference amounts of substances in each paint, each flame resistant paints showed its own characteristic spectrum and the contents of each substance could be determined. On-site flame resistant inspections can be used efficiently when institutional procedures are created.

The analytical application for cement using X-Ray diffraction and X-Ray fluorescence spectrometer (X-Ray Diffraction과 X-Ray Fluorescence를 이용한 시멘트 비교 분석)

  • Jung, Ji Eun;Jang, Yu Rim;Kim, Ki-Wook;Heo, Sangcheol;Min, Ji-Sook
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.340-351
    • /
    • 2013
  • The chemical element and structural characterization of different types of cements and its brick stones are been investigated under forensic aspects using X-ray florescence (XRF) and X-ray diffraction (XRD) spectrometer. The XRF provides rapid compositional data for controlling almost all stages of raw materials, clinker and cement. The decisive advantage of XRD methods is based on the unique character of the diffraction patterns of crystalline substances, the ability to distinguish between elements and their oxides, and the possibility to identify chemical compounds, polymeric forms, and mixed crystals by non-destructive examination. Therefore, combination of these examinations is useful and able to apply for the forensic analysis in comparison of cements and brick stones. There are more study remained to determine the viability of method for forensic analysis of brick stones and the limits of the discrimination that can be achieved.

The Correlations between Mineralogy and Engineering Characteristics of Soft Clay in Sihwa Area (시화지구 연약점토의 광물학적 특성과 공학적 특성의 상관관계)

  • Kim Nak-Kyung;Park Jong-Sik;Joo Yong-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.9
    • /
    • pp.155-166
    • /
    • 2004
  • The characteristics of soft clays are very important for the land development plan. This study is to investigate correlations between the engineering properties and the characteristics of clay minerals of the undisturbed clay samples obtained from Sihwa area. This study included X-Ray diffraction analysis, X-Ray fluorescence spectrometer analysis, scanning electron microscopy analysis and energy dispersive X-Ray spectrometer analysis. The correlations between the clay mineral properties and the laboratory and field testing results were investigated. The characteristics of soft clay in Sihwa area were compared with those in Yangsan and Kunsan area.

Crystal structure analysis of orthohombic $Sr_{0.6}Ca_{0.4}CuO_2$ compound (사방정계 $Sr_{0.6}Ca_{0.4}CuO_2$ 화합물의 결정구조해석)

  • Park, H.M.;Goetz, D.;Hahn, Th.
    • Korean Journal of Crystallography
    • /
    • v.7 no.1
    • /
    • pp.20-29
    • /
    • 1996
  • Sr0.6Ca0.4CuO2 single crystal has been synthesized by flux method and characterized by the single crystal X-ray diffraction. The compound has the orthorhombic system and the space group is Cmcm(63), lattice parameters are a=3.4645Å, b=16.1417Å, c=3.8727Å. In the (Sr1-xCax)CuO2 compound the limit of Ca from substitution for Sr was determined by the change of bond length. For this, X-ray diffraction, scanning electron microscopy (SEM), energy dispersive X-ray fluorescence (EDAX) and electron probe micro-analysis (EPMA) were used. From the change of Cu-O bond length as the Ca substitution, we concluded the limit of Ca incorporation Xca≒0.73.

  • PDF

Removal of Heavy Metals(Pb, Cr) Using Waste Eggshell

  • Park, Heung-Jai;Bong, Sang-Hun;Jeong, Seong-Ug
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.386-393
    • /
    • 2005
  • The calcination characteristic of waste eggshell were examined by thermal gravimetric analysis (TGA), qualitative and quantitative analysis by X-ray fluorescence, and microstructural analysis by scanning electronic microscopy(SEM). The calcined sample was lager grain and pore size.

  • PDF

X-ray Fluorescence Analysis of Chemical Ingredients for Portland Cement (X-선 형광분석법에 의한 포틀란드 시멘트의 정량분석)

  • 임헌진;백연봉;김도생;윤준수;이경원
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.8
    • /
    • pp.928-934
    • /
    • 1996
  • Quantitative analysis each portland cement components was conducted by standard calibration method using X-ray fluorescence spectrometer. Standard sample and the unknown sample were prepared by fused cast bead method. In checking the errors of standard cement 227A372 the relative errors of constituents such as CaO, SiO2, Al2O3, Fe2O3, MgO and SrO were less than 1% and the relative errors of constituents such as So3, K2O, TiO2, Na2O P2O5, and Mn2O3 were less than 5% Sample preparation was mainly contributed to the errors. Compared with general wet chemical method the results of X-ray fluorescence analyses were more precise and accurate. Moreover it is possible to analyze precisely a little amount of the constituents such as SrO, Mn2O3 and P2O5 the analyses of which were very difficult using the wet chemical method.

  • PDF