• Title/Summary/Keyword: X-ray Examination

Search Result 653, Processing Time 0.037 seconds

A Diagnostic Ultrasound Imaging System (초음파 영상진단장치)

  • Lee, Seong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.217-232
    • /
    • 1999
  • The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result. their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result. the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described.

  • PDF

A Study on X-ray Radiography for the Diagnosis of Screw Insertion Operation of Odontoid Fracture Patients in Cervical (목뼈 치아돌기 골절 환자의 나사못 삽입수술 진단을 위한 X-Ray 촬영법 연구)

  • Byung-Ju-Ahn;In-Soo Kim;Jong-Nam Song;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.309-315
    • /
    • 2024
  • The Study In order to obtain a Clear Image of fractures in Atlas and Axis of Cervical Spin, this Study obtained Images examined using a Cervical Spin Pantom and a Radiation device, and then Commissioned five Radiologists and three Orthopedic Regent Doctors for Subjective Psychological ROC (Receiver, Operation, Characteristic) Evaluation. As aRresult, the X-ray Tube was Tilted 15° toward the leg to Receive a high score of 29 Points during the Eamination, and the Objective Evaluation Signal-to-noise Ratio (SNR) was 6.032 points, which was high. In Addition, by Tilting the X-ray tube 10° toward the head, it received a high score of 33 points during the Examination, and a high score of 7.840 Points in the objective evaluation. And as a result of Subjectively and Objectively Statistically Evaluating the Examined Images, the Cronbach Alpha value was Calculated as 0.791. Since the Cronbach Alpha value was 0.7 or higher, the Reliability could be Evaluated as 'very good', and the significance probability (p) was Statistically Significant at 0.042 points.

The Study of Effectiveness in a Modified Rib Oblique Projection View Using a Chest Phantom (흉부팬텀을 이용한 변형된 늑골 사방향 검사의 유용성에 관한 연구)

  • Um, Ki-Tae;Lee, Min-Su;Kang, Sung-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.525-532
    • /
    • 2018
  • This study is filmed by applying the axial angle variation of the X-ray tube instead of the patient's position change during the perimetric examination of the ribs. A Reference image with the rib oblique examination using a chest phantom and experimental images applied with a six-phase variation in the axial angle by increasing $5^{\circ}$ tube angle each from $5^{\circ}{\sim}30^{\circ}$ from the vertical incident direction of the chest phantom to the right horizontal axis were obtained. For the quantitative comparative evaluation of the images, SNR and CNR were calculated for regions of interest in the experimental images based on the reference image. Also, the left-right rib ratio in the reference image and the left-right rib ratio in the experimental images are measured and compared. As a result of the study, the experimental images with a tube angle of $25^{\circ}$ were best shown in the measurements of the SNR, CNR and left-right rib ratio compared to the reference image with a standard examination method. The modified rib examinations will consider useful, if it is difficult to maintain the patient's examination position.

The Prognostic Factors in Progression of Pneumoconiosis (진폐증의 예후에 영향을 미치는 인자)

  • Kim, Hyung-Ju;Jang, An-Soo;Kim, Sang-Guk;Choi, Soo-In;Park, Sang-Hoo;Yang, Seung-Won;Seo, Jeong-Pyeong;Lee, Soong;Park, Hong-Bae;Son, Myung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.57-65
    • /
    • 1999
  • Backround : Pneumoconiosis is the parenchymal lung disease that results from the inhalation and deposition of dust, usually mineral dust of occupational or environmental origin. Most of the pneumoconiosis can be categorized to coal workers' pneumoconiosis (CWP) in Korea. No effective treatement is currently available, and the therapy for symptomatic CWP is limited to treatment of complication. Therefore authors analyzed and reviewed clinical features and radiological findings of 95 patients with pneumoconiosis for assessing the prognostic factors in disease progression. Method: We reviewed medical records of 95 cases with pneumoconiosis including history, chest X-ray, pulmonary function test, electrocardiography, AFB stain and culture of sputum, and routine blood examination between June 1995 and June 1997 in Seonam University Namkwang Hospital. Results: All of cases are male(mean age, 57.4 years), 91 cases out of them are miners. The mean duration of exposure to dust is 18.8 years. Major clinical symptoms are dyspnea (100%), sputum (71.6%), chest pain (55.8%), cough (23.2%), and hemoptysis (6.3%). 82 % of cases are over Morgan-Seaton Grade 2 in the degree of dyspnea. Small opacity on chest x-ray is 82.1 % and large opacity is 17.9%. Small opacity has tit type (37.2%), q/q type (25.6%) and r/r type (11.5%). B type is 42.2% in large opacity. For the pulmonary function test, restrictive type is 40.3%, mixed type 19.5% and obstructive type 8.3%. The more increasing chest Xray density, the more decreasing $FEV_1$ (p<0.01). 38% of patients show tuberculosis in chest X-ray, 15.8% positive smear of acid fast bacilli in sputum. The prevalence of pulmonary tuberculosis is high in patients with poor clinical condition. The cases with the active pulmonary tuberculosis have severe dyspnea. Expired cases show 100% and 75% of positive pulmonary tuberculosis in chest X-ray and sputum examination, respectively. 75% of expired cases show the chronic cor pulmonale, who died of acute respiratory failure. Conclusion: These findings indicate that tuberculoois infection has a decisive influence on the progress and prognoois of pneumoconioois.

  • PDF

Nationwise Survey of the X-ray Beam Collimator Utilization in General Diagnostic Radiograph (진단방사선 일반촬영에서의 X-ray Beam Collimator 사용 전국 실태조사)

  • Kim, Jee Hye;Sung, Dong-Wook;Kim, Jeong Wook;Shin, Jin Ho;Lee, Soon Keun;Jung, Kyung Il;Uhm, Jong Kwan;Lee, Ki Nam;Seong, Ho Jin;Kim, Youn Hyun;Kim, Hyeog Ju
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.119-126
    • /
    • 2013
  • Due to the introduction of CR and DR, it has been neglected the use of the X-ray beam collimator and field size. This study examines nationwide survey of the proper use of collimator and field size by area in a specific field of plain radiography and the current status. Authors emphasized the need for the field size criteria, and propose a standard reference field size in each specific radiologic examination. Total 333 medical institutions (included in Seoul, Gyeonggi-do, Jeolla, Chungcheong, Gangwon-do, Busan area), were investigated in relation to the status of the X-ray beam collimation field size, type specific inspection areas, medical facilities, and image analyses by type to figure out whether they use the adjustment of image field to the specific examination. To assess the awareness and the impact of radiation exposure to the collimation adjustable, 168 radiographers who was working in 10 general hospitals, 10 hospitals, and 10 clinics, were surveyed how they haver adjusted the actual field size. We examine that 61.3% of medical institutions used the "Proper collimation" and only 49.9% of them employed proper one in lumbar spine densely crowded by major organs. 69% among general hospitals, and 65% among hospitals using DR system were using proper collimation. Radiographers recognized that proper adjustment of collimation could reduce the harmful radiation dose on patients. In the survey, 97.6% of respondents were aware of this fact, but only 83.3% of respondents did the adjustment of the size of the collimation field. The using of proper collimation field was low in the nationwide survey, so the effort to reduce the radiation dose on the patients is urgently needed. A unified standard for the field accompanied by thorough education should be needed.

Facial Exposure Dose Assessment During Intraoral Radiography by Radiological Technologists (구내 촬영시 방사선사의 안면부 피폭선량 측정)

  • Yu, Hwan;Yang, Hanjoon
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.195-201
    • /
    • 2014
  • The study examined the changes in the decreased facial exposure dose for radiological technologists depending on increased distance between the workers and the X-ray tube head during intraoral radiography. First, the facial phantom similar to the human tissues was manufactured. The shooting examination was configured to the maxillary molars for adults (60kVp, 10mA, 50msec) and for children (60kVp, 10mA, 20msec), and the chamber was fixed where the facial part of the radiation worker would be placed using the intraoral radiography equipment. The distances between the X-ray tube head and the phantom were set to 10cm, 15cm, 20cm, 25cm, 30cm, 35cm, and 40cm. The phantom was radiated 20 times with each examination condition and the average scattered doses were examined. The rate at the distance of 40cm decreased by about 92.6% to 7.43% based on the scattered rays radiated at the distance of 10cm under the adult conditions. The rate at the distance of 40cm decreased by about 97.6% to 2.58% based on the scattered rays radiated at the distance of 10cm under the children conditions. Protection from the radiation exposure was required during the dental radiographic examination.

A Clinical Study of Cervical Radiculopathy in Patients with Shoulder Pain (견통을 주소로 한 경추부 신경근병변의 임상적 고찰)

  • Her Young-Gu
    • The Journal of Korean Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.17-22
    • /
    • 1994
  • The purpose of this study were to identify the correlation of shoulder pain to Cervical Pathology and effectiveness of Cervical treatment on the neck and shoulder. Sixty patients complaining of shoulder pain only without neck pain were evaluated by physical examination. Cervical X- rays and electrodiagnostic Study. The results were as follows: 1) Forty nine Cases were abnormal in plain Cervical spine X-ray with straightening of Cervical lordotic curve in 41 cases, Cervical spondybsis 16 cases and disc space narrowing in 4 cases. 2) Cervical radiculopathies were diagnosed 52 cases which showed abnormal spontaneous activities in needle. EMG : 26 cases in paraspinal muscles and 26 cases in both paraspinal and upper extremity muscles. 3) The results of treatment were excellent in 6 cases, good in 6 cases and fair in 32 cases. 4) Treatment side were effective with shoulder and conical in 36 cases.

  • PDF

The Study for Radio Protection According to a Possible Danger of Exposure During low energy X-ray Examination (저 에너지 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Jeong, Cheon-Soo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.187-188
    • /
    • 2011
  • 저 에너지 방사선검사 시 부득이하게 방사선 노출을 받게 되는 방사선 작업종사자나 환자의 보호자가 위치와 거리에 따른 방사선 피폭 선량의 감소 방안을 알아보고자 한다. Ion chamber mode 2026c, Reader기 20X6-1800을 사용하여 구강내 검사와 구강외 검사의 각각 검사실과 조정실에서의 관전압의 변화, 관전류와 조사시간의 변화, 조사방향의 변화에 따라 선량을 측정하였다. 그 결과 검사실 안에서는 최고선량이 평균 $702.8{\mu}R$으로 측정 되었으며, 조정실 안에서 측정하였을 경우 $20{\mu}R$이하의 낮은 선량을 보였으며, 후방검사보다 측방검사가 낮은 선량으로 나타났다. 방사선검사 시 위치와 거리에 따른 조사선량을 비교 분석하여, 적절한 거리 확보와 조사되는 중심방사선을 기준으로 측방($90{\sim}135^{\circ}$)에 위치함으로써 방사선 방어에 도움을 줄 것이며, 차폐문을 이용하여 방사선 피폭으로부터 감소 효과를 볼 수 있을 것이다.

  • PDF

Conservation of Buddhist Painting "Ten Kings of Hell" (십왕도(十王圖)의 보존처리(保存處理))

  • Cheon, Juhyun;Jang, Eunji;Kim, Woohyun
    • Conservation Science in Museum
    • /
    • v.4
    • /
    • pp.33-39
    • /
    • 2003
  • We examined the causes of the damage of a Joseon Buddhist painting, "Ten Kings of the Hell", for which we had performed conservation treatment while preparing for the special exhibition entitled "A Journey into the Joseon Buddhist Paintings", presented by the National Museum of Korea. For the parts that could not be easily observed by naked eyes, we examined it with microscopes, X-rays and infrared rays. Hereby we introduced the result of the scientific examination performed prior to the conservation treatment, and arranged its process for the "Ten Kings of the Hell".

Effects of Breast Dose on Plain Abdominal Position (복부 방사선검사 자세가 유방선량에 미치는 영향)

  • Joo, Young-Cheol;Kim, Sheung-Hyuk
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.