• 제목/요약/키워드: X-ray CT system

검색결과 161건 처리시간 0.028초

Microstructure and Biocompatibility of Porous BCP(HA/β-TCP) Biomaterials Consolidated by SPS Using Space Holder

  • Woo, Kee-Do;Kwak, Seung-Mi;Lee, Tack;Oh, Seong-Tak;Woo, Jeong-Nam
    • 한국재료학회지
    • /
    • 제26권8호
    • /
    • pp.449-453
    • /
    • 2016
  • $HA(hydroxyapatite)/{\beta}-TCP$ (tricalcium phosphate) biomaterial (BCP; biphasic calcium phosphate) is widely used as bone cement or scaffolds material due to its superior biocompatibility. Furthermore, $NH_4HCO_3$ as a space holder (SH) has been used to evaluate feasibility assessment of porous structured BCP as bone scaffolds. In this study, using a spark plasma sintering (SPS) process at 393K and 1373K under 20MPa load, porous $HA/{\beta}-TCP$ biomaterials were successfully fabricated using $HA/{\beta}-TCP$ powders with 10~30 wt% SH, TiH2 as a foaming agent, and MgO powder as a binder. The effect of SH content on the pore size and distribution of the BCP biomaterial was observed by scanning electron microscopy (SEM) and a microfocus X-ray computer tomography system (SMX-225CT). The microstructure observations revealed that the volume fraction of the pores increased with increasing SH content and that rough pores were successfully fabricated by adding SH. Accordingly, the cell viabilities of BCP biomaterials were improved with increasing SH content. And, good biological properties were shown after assessment using Hanks balanced salt solution (HBSS).

The electronic structure of the ion-beam-mixed Pt-Cu alloys by XPS and XANES

  • Lim, K.Y.;Lee, Y.S.;Chung, Y.D.;Lee, K.M.;Jeon, Y.;Whang, C.N.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.133-133
    • /
    • 1998
  • In the thin film alloy formation of the transition metals ion-beam-mixing technique forms a metastable structure which cannot be found in the arc-melted metal alloys. Sppecifically it is well known that the studies about the electronic structure of ion-beam-mixed alloys pprovide the useful information in understanding the metastable structures in the metal alloy. We studied the electronic change in the ion-beam-mixed ppt-Ct alloys by XppS and XANES. These analysis tools pprovide us information about the charge transfer in the valence band of intermetallic bonding. The multi-layered films were depposited on the SiO2 substrate by the sequential electron beam evapporation at a ppressure of less than 5$\times$10-7 Torr. These compprise of 4 ppairs of ppt and Cu layers where thicknesses of each layer were varied in order to change the alloy compposition. Ion-beam-mixing pprocess was carried out with 80 keV Ae+ ions with a dose of $1.5\times$ 1016 Ar+/cm2 at room tempperature. The core and valence level energy shift in these system were investigated by x-ray pphotoelectron sppectroscoppy(XppS) pphotoelectrons were excited by monochromatized Al K a(1486.6 eV) The ppass energy of the hemisppherical analyzer was 23.5 eV. Core-level binding energies were calibrated with the Fermi level edge. ppt L3-edge and Cu K-edge XANES sppectra were measured with the flourescence mode detector at the 3C1 beam line of the ppLS (ppohang light source). By using the change of White line(WL) area of the each metal sites and the core level shift we can obtain the information about the electrons pparticippating in the intermetallic bonding of the ion-beam-mixed alloys.

  • PDF

SPS로 제조된 HA/β-TCP 복합재의 기공의 크기와 분포에 미치는 지지체 량의 영향 (Effect of Space Holder Content on Pore Size and Distribution in HA/β-TCP Composites Consolidated by SPS)

  • 이택;우기도;강동수;이해철;장준호
    • 한국재료학회지
    • /
    • 제25권4호
    • /
    • pp.165-170
    • /
    • 2015
  • Ceramics biomaterials are useful as implant materials in orthopedic surgery. In this study, porous HA(hydroxyapatite)/${\beta}$-TCP(tricalcium phosphate) composite biomaterials were successfully fabricated using HA/${\beta}$-TCP powders with 10-30 wt% $NH_4HCO_3$ as a space holder(SH) and $TiH_2$ as a foaming agent, and MgO powder as a binder. The HA/${\beta}$-TCP powders were consolidated by spark plasma sintering(SPS) process at $1000^{\circ}C$ under 20 MPa conditions. The effect of SH content on the pore size and distribution of the HA/${\beta}$-TCP composite was observed by scanning electron microscopy(SEM) and a microfocus X-ray computer tomography system(SMX-225CT). These microstructure observations revealed that the volume fraction of the pores increased with increasing SH content. The pore size of the HA/${\beta}$-TCP composites is about $400-500{\mu}m$. The relative density of the porous HA/${\beta}$-TCP composite increased with decreasing SH content. The porous HA/${\beta}$-TCP composite fabricated with 30%SH exhibited an elastic modulus similar to that of cortical bone; however, the compression strength of this composite is higher than that of cortical bone.

지속성 좌상대정맥을 없이, 좌심방으로 연결되는 전관상정맥환류이상과 동반된 관상정맥동 입구폐쇄 1예: 심장전산화단층촬영 소견 (A Case of Coronary Sinus Atresia with a Total Anomalous Cardiac Venous Drainage to the Left Atrium without Persistent Left Superior Vena Cava: Imaging Findings on Cardiac CT)

  • 백상훈;강은주;이기남
    • 대한영상의학회지
    • /
    • 제82권4호
    • /
    • pp.982-987
    • /
    • 2021
  • 관상정맥동은 심장의 정맥 배출 체계이다. 관상정맥동 입구의 폐쇄는 드문 심장 기형이다. 선천적인 관상정맥동 입구의 폐쇄는 주로 지속성 좌상대정맥을 동반하며 그 외에 다른 심장 기형과 동반되어서 나타난다. 하지만 선천적인 관상정맥동 입구의 폐쇄만 단독적으로 나타나는 경우는 아주 드물다. 이 논문에서는 58세 여성에서 발견된 지속성 좌상대정맥을 동반하지 않고, 좌심방과 심장정맥이 연결되는 선천적인 관상정맥동 입구의 폐쇄만 단독적으로 나타나는 드문 증례를 보고하고자 한다.

Moire 영상을 이용한 근골격계 질환의 한의학적 진단에 관한 연구 (A Study on Oriental Medical Diagnosis of Musculoskeletal Disorders using Moire Image)

  • 이은경;유승현;이수경;강성호;한종민;정명수;천은주;송용선;이기남
    • 대한예방한의학회지
    • /
    • 제4권2호
    • /
    • pp.72-92
    • /
    • 2000
  • This research has conducted studies on an Oriental medicine-based method of diagnosing of occupational musculoskeletal system diseases. This researcher has searched through existing relevant medical literature. Also, this researcher has worked on a moire topography using moire topography. In this course, this researcher has reached the following conclusion in relation to the possibility of using a moire topography as a diagnosing device of musculoskeletal system diseases under Oriental medicine . 1 The Western medicine outlines its criteria of screening occupational musculoskeletal system diseases as follows A. The occupational musculoskeletal diseases must clearly include one or more of the subjective symptoms characterized by pain, hypoesthesia dysaesthesia, anaesthesia. etc . B, There should be clinically admitted objective observations and diagnosis outlining that the disease concerned shows symptoms such as tenderness, induration. and edema that can appear with occupational musculoskeletal system diseases. dyscinesia should be admitted with the disease concerned, or there should be observations and diagnosis outlining that abnormality exists in electric muscular or nervous diagnosis and examination . C. It should be admitted that prior to the occurrence of symptoms or observations and diagnosis on musculoskeletal system-related diseases, a patient has been engaged in works with conditions requiring improper work posture or work movement. That is, this is an approach whereby they see abnormality in the musculoskeletal system come from material and structural defect, and adjust and control abnormality in the musculoskeletal system and secreta . 2. The Oriental medicines sees that a patient develops the pain of occupational musculoskeletal diseases as he cannot properly activate the flow of his life force and blood thus not only causing formation of lumps in the body and blocking the flow of life force and blood in some parts of the body. Hence, The Oriental medicine focuses on resolving the cause of weakening the flow of life force and blood, instead of taking material approach of correcting structural abnormality Furthermore , Oriental medicine sees that when muscle tension builds up, this presses blood vessels and nerves passing by, triggering circulation dyscrasia and neurological reaction and thus leading to lesion. Thus, instead of taking skeletal or neurophysiological approach. it seeks to fundamentally resolve the cause of the flow of the life force and blood in muscles not being activated. As a result Oriental medicine attributes the main cause of musculoskeletal system diseases to muscle tension and its build-up that stem from an individual's long formed chronicle habit and work environment. This approach considers not only the social structure aspect including companies owners and work environment that the existing methods have looked at, but also individual workers' responsibility and their environmental factors. Hence, this is a step forward method. 3 The diagnosis of musculoskeletal diseases under Oriental medicine is characterized by the fact that an Oriental medicine doctor uses not only photos taken by himself, but also various detection devices to gather information and pass comprehensive judgment on it. Thus, it is the core of diagnosis under Oriental medicine to develop diagnosing devices matching the characteristics of information to be induced and to interpret information so induced from the views of Oriental medicine. Diagnosis using diagnosing devices values the whole state of a patient and formal abnormality alike, and the whole balance and muscular state of a patient serves as the basis of diagnosis. Hence, this method, instead of depending on the information gathered from devices under Western medicine, requires devices that provide information on the whole state of a patient in addition to the local abnormality information that X-ray. CT, etc., can offer. This method sees muscle as the central part of the abnormality in the musculoskeletal system and thus requires diagnosing devices enabling the muscular state. 4. The diagnosing device using moire topography under Oriental medicine has advantages below and can be used for diagnosing musculoskeletal system diseases with industrial workers . First, the device can Provide information on the body in an unbalanced state. and thus identify the imbalance and difference of height in the left and right stature that a patient can not notice at normal times. Second, the device shows the twisting of muscles or induration regions in a contour map. This is not possible with existing shooting machines such as X-ray, CT, etc., thus differentiating itself from existing machines. Third, this device makes it possible for Oriental medicine to take its unique approach to the abnormality in the musculoskeletal system. Oriental medicine sees the state and imbalance state in muscles as major factors in determining the lesion of musculoskeletal system, and the device makes it possible to shoot the state of muscles in detail. In this respect, the device is significant. Fourth, the device has an advantage as non-aggression diagnosing device.

  • PDF

소아복부 종괴의 방사선학적 고찰 (Radiologic Evaluation of Intraabdomenal Masses in Childhood)

  • 권혁포;변우목;황미수;김선용;장재천;박복환
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.33-42
    • /
    • 1988
  • 최근 5년간의 소아의 복부종괴 23예를 발생빈도, 부위 및 방사선학적 소견을 중심으로 비교분석하여 다음과 같은 결론을 얻었다. 1. 전체 23예중 신경아세포종이 6예로 가장 많았고 그 다음이 Wilms 종양 5예, 담도낭종, 난소종양, 수신종 등의 순위였다. 2. 발생연령별로 분석해 본 결과 6세 이하가 78%(14예)를 차지했고 특히 후복강 종양은 6세 이하에 집중되어 있었다. 3. 부위별로는 후복강 종양이 60%(14예)로 가장 많았다. 4. 방사선학적 소견을 분석하여 본 결과 1) 단순 복부촬영상 신경아세포종의 50%에서 특징적인 석회와 음영을 볼 수 있었고 후복강 종양의 대부분에서 비특이적인 석회화 음영을 볼 수 있었다. 2) 초음파 소견상 저에코, 고에코 또는 혼합에코 등의 종괴 내부성상을 알 수 있었으나 종괴의 정확한 해부학적 위치를 파악할 수 없는 경우가 많았다. 3) 경정맥 신우 조영촬영상 신우신배의 비정상적인 소견과 신장의 전위 소견으로부터 신장내 종양과 신장의 다른 부위의 종양을 구분할 수 있었다. 4) 전산화 단층촬영상 종괴 내부의 성상뿐만 아니라 종괴의 해부학적인 위치, 주위 구조와의 관계, 임파절이나 다른 부위로의 전이유무를 알 수 있었다.

  • PDF

상용화된 영상의학 인공지능 의료기기의 기술 및 동향 분석 (Analyze Technologies and Trends in Commercialized Radiology Artificial Intelligence Medical Device)

  • 한창화
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.881-887
    • /
    • 2023
  • 본 연구는 한국에서 상용화된 인공지능(AI) 기반 의료 영상 장치의 발전과 현재 동향을 분석하는 것을 목표로 한다. 2023년 9월 30일 기준으로 한국 식품의약품안전처에 허가, 인증 및 신고된 AI 기반 의료기기는 총 186개로, 이 중 138개가 영상의학과와 관련된 제품이었다. 본 연구는 2018년부터 2023년까지의 연도별 허가 추세, 장비 유형, 적용 부위, 주요 기능 등을 종합적으로 고찰하였다. 연구 결과, AI 의료기기는 2018년 4개 제품에서 시작하여 2023년까지 꾸준한 성장세를 보였으며, 특히 2020년 이후 급격한 증가세를 나타내었다. 이는 AI 기술의 발전과 의료분야의 수요 증가가 상호 작용한 결과로 볼 수 있다. 장비별로는 CT, X-ray, MR 순으로 AI 의료기기가 개발되었으며, 이는 각 장비별 이미지의 특성과 임상적 중요성을 반영한다. 본 연구에서는 흉부, 뇌신경, 근골격계 등 특정 부위에 대한 AI 의료기기 개발이 활발한 것을 확인하였고, 주요 기능별로는 의료영상 분석, 탐지 및 진단 보조, 영상 전송 등이 주를 이루었다. 이러한 결과는 AI의 패턴 인식 및 데이터 분석 능력이 의료영상 분야에서 중요한 역할을 하고 있음을 시사한다. 또한, 본 연구는 한국 제품이 국제적인 인증, 특히 미국 FDA와 유럽 CE 인증을 받은 사례를 조사하였다. 그 결과, 다수의 제품이 두 기관의 인증을 받았으며, 이는 한국의 AI 의료기기가 국제적 수준에 부합하며, 글로벌 시장에서의 경쟁력을 갖추고 있음을 보여준다. 본 연구는 AI 기술이 의료영상 분야에서 미치는 영향과 그 발전 가능성을 분석함으로써, 향후 연구 및 개발 방향에 중요한 시사점을 제공한다. 하지만, 규제 측면, 데이터의 질과 접근성, 임상적 유효성 등의 도전 과제도 지적되어, 이러한 문제들에 대한 지속적인 연구와 개선이 요구된다.

소장 용적 측정을 통한 직장암의 수술 후 방사선치료 시 사용하는 소장 전위 장치(Small Bowel Displacement System : SBDS) 의 효용성 검토 (Efficacy of Small Bowel Displacement System in Post-Operative Pelvic Radiation Therapy of Rectal Cancer)

  • 안용찬;임도훈;김문경;우홍균;김대용;허승재
    • Radiation Oncology Journal
    • /
    • 제16권1호
    • /
    • pp.63-69
    • /
    • 1998
  • 목적 : 본 연구는 치료 선량의 방사선 조사역 내에 포함되는 소장의 용적을 전산화 단층 촬영을 통하여 측정함으로써 직장암의 수술 후 방사선치료 시 사용하는 소장 전위 장치의 효용성을 검토해보고자 하였다. 대상 및 방법 1997년 5월에 삼성서울병원 치료방사선과에서 방사선치료를 시작하게 된 10명의 직장암 환자들을 대상으로 하였다. 소장의 확인 및 구별을 용이하게 하기 위해 모의 치료 시작 전에 환자들에게 $Gastrographln^(R)$ 을 마시게 하였으며, 모의치료 시에는 환자들을 복와위로 엎드리게 하여 소장 전위 장치를 사용하지 않은 상태와 사용한 상태에서 방사선 조사역을 각각 결정하여 후전 및 측방 X-ray 영상을 얻었고, 같은 조건으로 전산화 단층 촬영을 각각 시행하였다. 전산화 단층 촬영 영상에서 조영제로 구별이 되는 소장 중에서 치료 선량의 방사선 조사역 내에 포함되는 소장의 용적을 영상 저장 및 전송 시스템(PACS) 을 이용하여 측정하였다. 결과 : 소장 전위 장치의 사용 전 및 사용 후의 측정된 소장의 평균 용적은 185.1ml(54.5-434.2ml) 및 176.0ml(5.2-415.6ml) 이었다. 소장 전위 장치의 사용 전과 비교한 사용 후의 소장 용적의 증감은 $10\%$ 이상 감소가 3명, $10\%$ 이하의 감소가 2명, $10\%$ 이하의 증가가 3명, $10\%$ 이상의 증가가 2명씩 이었다. 결론 : 직장암의 수술 후 방사선치료 시 사용하는 소장 전위 장치의 효용성을 소장 용적의 측정을 통하여 검토하여 본 결과 이 장치의 제작 및 사용에 소요되는 추가적인 시간과 노련을 감안하여 볼때 큰 이득이 없을 것으로 판단된다. 대한 반응이었으며, 병리학적 종류와 자궁 주변 침범의 정도는 경계의 의미가 있었다. 57명의 치료 실패가 있었으며 국소 재발은 2년 이내가 대부분 이었고 원격 전이는 3년 이후도 $29\%$를 보였다. 만성 합병증은 28명(16.8%) 38건에서 보였으며 발생률과 심한 정도가 총 선량과 1회당 선량에 유의한 상관관계가 있었다. 결론 : 국소적으로 진행된 자궁경부암은 종양의 크기와 치료에 대한 반응이 생존율과 국소재발에 가장 영향을 주는 요소이므로 방사선 치료를 할 때 종양의 크기에 따라 세분화하고 종양이 큰 경우 기존의 방법으로는 실패율이 비교적 높으므로 방사선 치료 기간의 단축이나 항암제의 추가 등을 고려하여 치료의 효과를 높여야 하며, 환자의 추적 관찰은 2년 이내 국소재발과 원격 전이가 많으므로 2년 이내는 적극적 추적 관찰의 중요성과 원격 전이의 경우 3년 이후 5년 이내에도 재발이 많기 때문에 종양표지자나 방사선학적 추적 관찰이 중요하다. 그리고 만성 합병증을 최소화하기 위해 적절한 질 packing 등으로 주위 조직의 방사선 피폭량을 줄여야 할 것으로 생각된다. 환자의 2년 생존을과 5년 생존율은 $29.9\%$$13.3\%$로 나타났으며, 병기가 낮고, 임상수행능력이 높을수록 생존율이 향상됨을 알 수 있었다. 또한 근치적 절제술후 방사선 치료를 받은 환자와 항암화학요법을 병행한 군의 치료성적이 비교적 높은 것으로 볼 때, 담낭 및 간외담도계 악성종양환자중 일부에서 적극적인 병합치료요법이 생존율의 향상에 도움을 줄 것으로 기대된다.술후 방사선치료 단독시행한 치료군보다 국소제어율을 높여주는 것을 알 수 있었으나($50.3\%\;vs.\;65.8\%,\;p=0.04$),

  • PDF

심폐소생술 후 발생한 다량의 기복증 (Massive pneumoperitoneum following cardiopulmonary resuscitation)

  • 최정우;신상열;황용
    • 한국산학기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.3303-3307
    • /
    • 2015
  • 본 연구는 74세 여자 환자가 심정지 후 일반인과 119구급대원들에게 시행된 심폐소생술의 합병증인 기복증에 대한 증례를 경험하였기에 이에 대한 임상양상과 병태생리를 조사하기 위해 시도되었다. 평소 건강했던 74세 여자가 식당에서 일하던 중 갑자기 발생한 의식저하로 쓰러졌다. 증상발생 후 즉시 119에 신고를 하였고 현장에서 목격자에 의한 즉각적인 심폐소생술이 시행되었으며, 현장에 도착한 119구급대원에 의한 심폐소생술과 제세동이 시행된 결과 자발순환을 회복하였다. 자발순환 회복 후 환자는 인근 2차병원으로 이송되어 시행한 심전도 검사에서 급성심근경색이 의심되어 추가적인 검사와 치료를 위해 3차병원으로 이송되었다. 이후 시행한 X-ray 검사와 복부전산화 단층촬영 검사결과 위문접합부의 파열과 다량의 기복증을 보여 수술치료를 결정하였으나 수술실에서 다시 심정지가 발생하여 심폐소생술을 시행하였으나 환자는 결국 사망하였다. 따라서 병원 전 현장에서 심폐소생술을 시행 할 때 흉부압박의 정확한 위치 선정이 필요하며 양압 환기에 대한 신중한 고려가 필요하겠다. 또한 심폐소생술 후 발생한 기복증의 치료는 환자의 혈역학적 상태를 충분히 고려해야 할 것으로 사료된다.

전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구 (Research on Dose Reduction During Computed Tomography Scanning by CARE kV System and Bismuth)

  • 곽영곤;김종일;정성표
    • 한국콘텐츠학회논문지
    • /
    • 제14권8호
    • /
    • pp.233-242
    • /
    • 2014
  • 본 논문에서는 전산화 단층검사 시 방사선 투과 물질로 방사선량을 흡수하여 피폭 선량을 감소시키는 물질로 알려진 차폐용 Bismuth(비스무스)와 CARE kV(Automated Dose-Optimized Selection of X-ray Tube Voltage)을 사용하여 유용성을 평가하였다. 방사선 감수성이 높은 기관인 수정체(안와), 갑상선, 가슴(유방), 생식기의 선량 감소 효과와 각 기관의 심부선량 차폐 효과를 평가하기 위해 Rando Phantom과 유리 선량계를 이용하여 Bismuth 사용 전 후와, CARE kV의 적용에 따른 선량 감소 효과를 비교해 보았다. 그 결과, 뇌혈관 검사 시 CARE kV을 단독 설정한 검사 방법의 선량이 가장 적었으며, CARE kV 사용여부에 따라 63%의 선량 감소 효과가 있었다. 경동맥 검사 시 CARE kV+Bismuth의 설정 방법에서 선량이 13% 증가하였다. 심혈관 검사 시 CARE kV+Bismuth의 설정 방법이 31% 선량 감소 효과가 있었다. 하지 혈관 검사 시 Bismuth 전체의 설정 방법이 가장 선량이 적게 측정되었지만, 영상 평가 기준에 부적합 하였다. CARE kV을 설정한 검사 방법과는 약 9%의 선량 감소 효과가 있었다.