• 제목/요약/키워드: X-ray 영상 센서

검색결과 57건 처리시간 0.021초

명암 대비와 에지 선예도를 이용하는 영역 성장법에 의한 디지털 X선 맘모그램 영상에서의 미세 석회화 검출 (Microcalcification Detection Based on Region Growing Method with Contrast and Edge Sharpness in Digital X-ray Mammographic Images)

  • 원철호;강신원;조진호
    • 센서학회지
    • /
    • 제13권1호
    • /
    • pp.56-65
    • /
    • 2004
  • In this paper, we proposed the detection algorithm of microcalcification based on region growing method with contrast and edge sharpness in digital X-ray mammographic images. We extracted the local maximum pixel and watershed regions by using watershed algorithm. Then, we used the mean slope between local maximum and neighborhood pixels to extract microcalcification candidate pixels among local maximum pixels. During increasing threshold value to grow microcalcification region, at the maximum threshold value of the contrast and edge sharpness, the microcalcification area is decided. The regions of which area of grown candidate microcalfication region is larger than that of watershed region are excluded from microcalcifications. We showed the diagnosis algorithm can be used to aid diagnostic-radiologist in the early detection breast cancer.

디지털 흉부엑스선 검사에서 환자선량 감소를 위한 부가필터와 Ion chamber 센서 조합 (The Additional Filter and Ion Chamber Sensor Combination for Reducing Patient Dose in Digital Chest X-ray Projection)

  • 이진수;김창수
    • 한국방사선학회논문지
    • /
    • 제9권3호
    • /
    • pp.175-181
    • /
    • 2015
  • 본 연구는 디지털 흉부엑스선 검사에서 화질의 저하 없이 환자선량을 감소시키기 위한 부가필터와 Ion chamber 센서 조합을 알아보고자 하였다. 실험은 관전압 125 kVp, 관전류 320 mA, AEC모드로 하여 부가필터와 Ion chamber의 센서를 네 가지 조합으로 나누어 선량을 측정하고, PCXMC를 이용하여 장기선량을 산출하였다. 또한 MTF로 물리적 화질을 평가하였다. 그 결과 동일 부가필터의 조건하에서 Ion chamber의 좌우 양쪽 센서 모두를 선택했을 때 입사표면 선량과 장기선량이 가장 낮게 나타났으며, 화질평가에서는 좌우 Ion chamber의 선택과 0.1 mmCu 필터를 선택했을 때 공간주파수 값이 2.494 lp/mm로 가장 높게 나타났다. 결론적으로 디지털 흉부촬영 시 Ion chamber의 좌우 양쪽 센서와 0.1 mmCu 필터를 선택하는 것이 우수한 화질의 영상을 획득하고 환자선량 저감에 도움이 될 것이다.

기체전자증폭기를 이용한 X-선 영상획득실험에 관한 연구 (A Study for The X-ray Image Acquisition Experiment Using by Gas Electron Multipliers)

  • 강상묵;한상효;조효성;남상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권2호
    • /
    • pp.83-89
    • /
    • 2003
  • 기체전자증폭기는 기존의 기체검출기의 표류공간에 위치하여 표류전기장을 매우 짧은 거리에 걸쳐 전자사태가 가능한 세기(〉 $10^4$ V/cm) 이상으로 압축함으로써 기체이득을 향상시키는 개념적으로 간단한 기구이다 이 기구는 양면이 금속(구리)으로 얇게 코팅된 수십 $\mu\textrm{m}$ 두께의 절연성 foil에 화학적 에칭이나 고출력 레이저빔 천공방법을 이용하여 직경 100 $\mu\textrm{m}$ 이하의 미소 hole들을 100-200 $\mu\textrm{m}$ 간격으로 균일하게 뚫어 놓은 구조로 되어 있다. 본 연구에서는 다양한 실험조건에서 기체전자증폭기의 동작특성을 조사하였으며 또한 기체전자증폭기의 섬광특성을 이용하여 표준 CCD 카메라와 결합하여 X-선 영상을 획득함으로써 디지털 X-선 영상센서로서의 가능성을 제시하였다.

비정질 셀레늄을 이용한 평판 Digital X선 검출기 개발 (Development of flat panel digital x-ray detectorusing a-Se)

  • 박지군;최장용;강상식;차병열;장기원;최준영;남상희
    • 대한디지털의료영상학회논문지
    • /
    • 제6권1호
    • /
    • pp.24-30
    • /
    • 2003
  • 평판 digital x-선 검출기는 차세대 x-ray system으로 최근 연구와 개발이 활발하게 진행되고 있는 system이다. 본 연구는 환자의 피폭 및 작업 종사자의 피폭을 최소화 할 수 있고 의료장비의 디지털화에 발맞추어 PACS 등에 사용 가능한 a-Se을 이용한 직접방식의 digital x-선 검출기 구현에 관한 것이다. Prototype digital x-선 검출기는 TFT층과 a-Se층으로 이루어져 있다. Digital x-선 검출기센서 증착과 정의 최적화 수행 결과를 참고문헌1)-4)과 비교했을 때 매우 유사함을 확인하였다. 제작된 검출기의 pixel pitch는 $139{\mu}m$였고, fill factor는 86%, 전체 검출기의 검출면적은 14"${\times}$8.5"였다. Digital 영상의 해상력을 고려하기 위해 손과 test 패턴영상을 얻었고, 58%, 3.0lp/mm의 높은 MTF를 얻을 수가 있었다. 이러한 결과로 a-Se 기반의 Digital X선 검출기가 구현되었으며 본 연구결과를 토대로 향후 digital X선 검출기 개발기술의 발전과 성능향상을 가져올 것으로 기대된다.

  • PDF

등가회로 모델에 의한 레이저다이오드의 누설전류 해석 (Analysis of Leakage Current of a Laser Diode by Equivalent Circuit Model)

  • 최영규;김기래
    • 한국정보통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.330-336
    • /
    • 2007
  • 본 논문에서는 디지털 의료 영상 및 진단 분야 그리고 산업용으로도 활용 가능한 싱글 포톤 계수형 영상센서를 $0.18{\mu}m$ triple-well CMOS(Complementary Metal Oxide Semiconductor) 공정을 사용하여 설계하였다. 설계된 Readout 칩용 싱글 픽셀은 디지털 X-ray 이미지 센서모듈을 간단화 하기 위해 단일 전원전압을 사용하였으며, Preamplifier의 출력 전압인 signal voltage(${\Delta}Vs$)를 크게 하기 위해 Folded Cascode CMOS OP amp를 이용한 Preamplifier를 설계하였으며, 기존의 Readout 칩 외부에서 인가하던 threshold voltage를 Readout 칩 내부에서 생성해 줄 수 있도록 Externally Tunable Threshold Voltage Generator 회로를 새롭게 제안하였다. 그리고, Photo Diode에서 발생하는 Dark Current Noise를 제거하기 위한 Dark Current Compensation 회로를 제안하였으며, 고속 counting이 가능하고, layout 면적이 작은 15bit LFSR(Linear Feedback Shift Resister) Counter를 설계하였다.

영상장치 센서 데이터 QC에 관한 연구 (A study on imaging device sensor data QC)

  • 윤동민;이재영;박성식;전용한
    • Design & Manufacturing
    • /
    • 제16권4호
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

진단 X선 영상을 위한 CsI:Na/a-Se 구조설계 및 신호특성 (The signal property and structure design of CsI:Na/a-Se for diagnostic x-ray imaging)

  • 박지군;허예지;박정은;박상진;김현희;노시철;강상식
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.35-38
    • /
    • 2009
  • 최근 의료영상분야에서 형광체와 광도전체 물질을 이용한 디지털 평판형 X선 영상검출기가 폭넓게 이용되고 있다. 본 연구는 CsI:Na 형광체층과 광민감도가 우수한 비정질 셀레늄(a-Se)층의 이중 접합구조로 구성된 변환구조 설계를 위한 몬테카를로 시뮬레이션과 X선에 대한 광학적 및 전기적 반응특성을 조사하였다. 먼저 CsI:Na의 발광스펙트럼과 a-Se의 광흡수 스펙트럼을 측정하여 X선에 의한 신호 변환특성을 분석하였다. 또한, 인가전기장의 함수에 따른 X선 민감도을 측정하여 상용화된 a-Se($500{\mu}m$)의 직접변환 검출기와 비교 평가하였다. 측정결과로부터, $10V/{\mu}m$에서 CsI:Na($180{\mu}m$)/a-Se($30{\mu}m$) 변환센서의 X선 민감도는 $7.31nC/mR-cm^2$ 이고, a-Se($500{\mu}m$) 검출기는 $3.95nC/mR-cm^2$로 약 2배 정도 높은 값을 보였다.

  • PDF

Dual-Sensor 기반 스테레오 X-선 영상의 3차원 형상복원기술을 이용한 검색 자동화를 위한 연구 (The Study of automated inspection technology using a three-dimensional reconstruction of stereo X-ray image based dual-sensor Environment)

  • 황영관;이남호;김종열
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.695-698
    • /
    • 2014
  • 화물 검색용으로 사용되고 있는 X-선 검색장치는 대상물의 단면 정보만을 제공하고 있기에 검색 대상체의 식별에 어려움이 있어 이에 대한 개선이 요구되어 왔다. 또한 대량의 화물 검색을 효율적으로 수행하기 위해서는 검색시스템에 대한 자동화가 요구되며 자동화를 위해서는 대상체를 식별하기 위한 다양한 식별자가 필요하다. 스테레오 X-ray 시스템은 기존의 검색 장치에 라인센서를 추가하여 검색 대상체에 대한 추가적인 정보를 제공함으로써 검색 효율을 높이도록 고안되었다. 본 논문에서는 선행 연구를 통해 개발된 스테레오 X-선 검색장치를 이용하여 다양한 물체에 대한 검색을 수행하며 형상정보를 복원하여 실제 값과의 비교를 통해 스테레오 방사선 스캔장치에 대한 성능분석을 수행하였다. 또한 본 논문에서 제시하는 3차원 형상복원 알고리즘을 통해 검색시스템을 자동화할 수 있는 새로운 식별자의 제공이 가능하다고 판단된다. 본 연구의 결과는 대형 화물 스캔 장치 및 고속화물 스캔 장치 개발을 위해 활용될 수 있다.

  • PDF

광계수형 센서의 포톤계수효율 평가를 위한 포톤플루엔스 측정 (Measurement of the Photon Fluence for the Evaluation of Photon Detection Efficiency of Photon Counting Sensor)

  • 박지군;허예지;김교태;노시철;강상식
    • 한국방사선학회논문지
    • /
    • 제10권1호
    • /
    • pp.1-6
    • /
    • 2016
  • 현재 CCD 및 TFT LCD 기반의 평판형 디지털 X선 센서를 이용한 많은 디지털 X선 영상장치가 활용되고 있으며, 특히 포톤계수형 센서 기술에 대한 많은 연구가 수행되고 있다. 본 연구에서는 포톤계수형 센서의 정량적 성능 평가 항목인 포톤계수효율을 측정하기 위해 포톤계수형 센서 물질에 입사되는 X선 플루엔스 측정하였다. IEC 61223-1-2 권고안의 RQA-M2 Radiation beam quality를 이용하여 포톤 플루엔스를 측정한 결과, $10{\mu}m$ 핀홀 영역에서 입사 광자 플루엔스는 $4photon/unit\;area{\cdot}{\mu}Gy$, $30{\mu}m$ 핀홀 영역에서 약 $50photons/unit\;area{\cdot}{\mu}Gy$, $100{\mu}m$ 핀홀 영역에서 $698photons/unit\;area{\cdot}{\mu}Gy$의 플루엔스로 규정할 수 있었다. 셋업된 입사 플루엔스를 이용하여 포톤계수형 센서 물질에서의 X선 조사시 출력파형을 측정함으로써 실제 포톤계수효율을 측정할 수 있을 것으로 판단된다.

싱크로트론 방사선 영상 획득을 위한 Hybrid 기반의 X선 센서 제작 및 특성 (The Characteristic of Hybrid X-ray Sensor for Synchrotron Radiation image)

  • 차병열;강상식;김소영;윤경준;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 반도체 재료 센서 박막재료 전자세라믹스
    • /
    • pp.68-71
    • /
    • 2004
  • 본 연구는 싱크로트론 방사광의 단색광 (monobeam)을 이용한 영상을 획득하였다. 영상센서로서 CMOS를 사용하였으며 센서 앞단에는 형광체 (phosphor)를 이용하여 방사광에 대한 빛의 신호로서 영상을 획득하였다. 사용된 싱크로트론 방사광의 beam size는 $5mm{\times}2mm$ 이며 ion chamber를 통한 beam intensity 는 $10{\times}10^{-7}$이다. 형광체는 각각 ZnS(Cu:Al), ZnS(Ag,Al), $BiTiO_3$, $Y_2O_2S(Tb)$로서 4가지를 사용하였으며 여기에 사용된 형광체는 기계식 스크린 프린팅 (Screen Printing) 방식으로 직접 제조하였다. 두께는 모두 동일하게 $10{\mu}m$이며 각각에 대한 PL(Photoluminescence)을 측정하여 분석하였다. object로는 물고기와 20linepair를 사용하였으며 CMOS센서를 이용하여 각각의 phosphor에 대하여 영상을 획득하였다. 영상의 평가는 20line pair 영상의 MTF를 이용하였다. 각각의 형광체에 대한 MTF는 5 lp/mm 에서는 0.5650, 0.2150, 0.7890, 0.3840 이며 10 lp/mm 은 0.4500, 0.0900, 0.2510, 0.1500이고 15 lp/mm 는 0.1900, 0.0300, 0.1430, 0.0500이며 마지막으로 20 lp/mm 은 0.0810, 0.004, 0.0500, 0.0320의 MTF 값을 나타내었다. $10{\mu}m$ 두께에 대하여 ZnS(Cu:Al)이 가장 좋은 MTF의 값을 나타내었다.

  • PDF