• Title/Summary/Keyword: X-ray 시스템

Search Result 499, Processing Time 0.035 seconds

Development of Various Inorganic Crystal Structure Database Retrieval System (다양한 무기결정구조데이터베이스(ICSD) 검색 시스템 개발)

  • 김지영;이상호;한정민
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.05a
    • /
    • pp.529-534
    • /
    • 2004
  • KISTI has intended to provide domestic researchers of chemistry and materials with the Inorganic Crystal Structure Database free of charge. Therefore, we construct the database and develop new web-based information searching system with the use of the ICSD data licensed by the FIZ Karlsruhe, Germany. We organize several menus possible to search the structure of crystal in a variety of ways on the web and the search results show not only numerical data of the structure of crystal but also the graphic of X-ray diffraction pattern and the 3-dimension structure of crystal. The data will be updated continuously and the searching system will be improved in order to provide researchers with information easily and swiftly.

  • PDF

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

A Charge Pump Circuit in a Phase Locked Loop for a CMOS X-Ray Detector (CMOS X-Ray 검출기를 위한 위상 고정 루프의 전하 펌프 회로)

  • Hwang, Jun-Sub;Lee, Yong-Man;Cheon, Ji-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.359-369
    • /
    • 2020
  • In this paper, we proposed a charge pump (CP) circuit that has a wide operating range while reducing the current mismatch for the PLL that generates the main clock of the CMOS X-Ray detector. The operating range and current mismatch of the CP circuit are determined by the characteristics of the current source circuit for the CP circuit. The proposed CP circuit is implemented with a wide operating current mirror bias circuit to secure a wide operating range and a cascode structure with a large output resistance to reduce current mismatch. The proposed wide operating range cascode CP circuit was fabricated as a chip using a 350nm CMOS process, and current matching characteristics were measured using a source measurement unit. At this time, the power supply voltage was 3.3 V and the CP circuit current ICP = 100 ㎂. The operating range of the proposed CP circuit is △VO_Swing=2.7V, and the maximum current mismatch is 5.15 % and the maximum current deviation is 2.64 %. The proposed CP circuit has low current mismatch characteristics and can cope with a wide frequency range, so it can be applied to systems requiring various clock speed.

A Study on the Liquid Crystal Formed in PLO Gel Containing Ceramide NP (Ceramide NP 를 함유한 PLO Gel 에서 형성되는 액정에 관한 연구)

  • Heo, Min Geun;Yoon, Kyung-Sup
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.1
    • /
    • pp.85-92
    • /
    • 2021
  • The stratum corneum is formed from keratinocytes and intercellular lipids, with ceramide as the main component of intercellular lipids. Ceramides are one of the important components of the intercellular lipids to form a lamellar structure, but they are insoluble and therefore are not suitable for direct application to the skin. Thus, it was intended to apply ceramide to the formulation of pluronic lecithin organogel (PLO gel), which received constant attention among drug delivery systems. A suitable oil for formulation was selected and a PLO gel containing ceramide was manufactured. Liquid crystal formation and variation were observed using polarized microscopes, and viscoelastic analysis was performed to find out the viscoelastic behavior of the PLO gel. Small-angle X-ray scattering (SAXS) and wide-angle X-ray scattering (WAXS) analysis were performed to confirm the structures in the formulation. Results showed that the size and stability of the liquid crystal differed depending on the content ratio of ceramide and lecithin in the PLO gel containing ceramide. Furthermore, viscoelastic analysis showed the stability of the formulation, and SAXS/WAXS analysis confirmed that the PLO gel without ceramide had hexagonal structure of the quadrilateral system array, and the PLO gel with ceramide had the lamellar structure of the quadrilateral system array.

Study on Synthesis of Boron-Containing Nanoparticles Using Thermal Plasma System (고온 플라즈마를 이용한 붕소 함유 나노입자 제조에 관한 연구)

  • Shin, Weon-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.731-736
    • /
    • 2012
  • A new method for producing boron-containing nanoparticles is described. Boron trichloride ($BCl_3$) and methane ($CH_4$) are dissociated through injection into a thermal plasma followed by a nucleation process producing boron or boron carbide nanoparticles. X-ray photoelectron spectroscopy was used to detect B-C bonds related to the carbide state and to probe the ratio of boron to carbon in the B-C bond structure. In addition, nanoparticles were characterized with scanning transmission electron microscopy and electron energy loss spectroscopy. It was found that nanoparticles were in the range 30-70 nm and a boron to carbon ratio in the B-C bond structure of up to 2 can be reached when $BCl_3$ of 20 sccm and $CH_4$ of 25 sccm were used.

Influence of Electroless Ni-plated MWCNTs on Thermal Conductivity and Fracture Toughness of MWCNTs/Al2O3/Epoxy Composites (무전해 니켈도금된 다중벽 탄소나노튜브의 첨가가 알루미나강화 에폭시 복합재료의 열전도도 및 파괴인성에 미치는 영향)

  • Choi, Jeong-Ran;Lee, Young-Sil;Park, Soo-Jin
    • Polymer(Korea)
    • /
    • v.37 no.4
    • /
    • pp.449-454
    • /
    • 2013
  • In this work, the effect of electroless Ni-plating of multi-walled carbon nanotubes (MWCNTs) on thermal conductivity and fracture toughness properties of MWCNTs/$Al_2O_3$/epoxy composites was investigated. The surface properties of the Ni-plated MWCNTs were determined by scanning electron microscopy (SEM), X-ray photoelectron spectrometry (XPS), and X-ray diffraction (XRD) analyses. Thermal conductivity was tested using a thermal conductivity measuring system. The fracture toughness of the composites was carried out through the critical stress intensity factor ($K_{IC}$) measurement. As a result, the electroless Ni-plated MWCNTs led to a significant change of surface characteristics of the MWCNTs. Thermal conductivity and fracture toughness of the MWCNTs/$Al_2O_3$/epoxy composites were greater than those of non-treated ones. These results were probably due to the improvement of intermolecular interaction between the Ni-MWCNTs and the matrix resins.

Design of essage-based Collaborative System for Mobile Medical System (모바일 시스템을 위한 메시지 기반의 협력 시스템 설계)

  • Koo Je-young;Oh Geun-tak;Lee Yun-bae
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.430-432
    • /
    • 2005
  • PDA는 작은 몸체로 이동성 및 편리성 등이 PC보다 뛰어나지만, 처리 속도가 상대적으로 느리기 때문에 해상도가 큰 이미지, 높은 처리 속도를 요구하는 작업 등을 처리하기에는 효율성이 낮은 문제점이 있다. 또한 정보를 Display할 수 있는 액정이 매우 작아서 환자와 관련된 의료 영상 즉, MRI 사진이나 X-ray 사진 등을 자세히 보기에는 현재의 기술력으로는 매우 어렵다. 그리고 특히 다수의 PDA와 PC 클라이언트의 데이터 요청으로 인한 서버의 과부하 문제 또한 모바일 진료시스템의 발전에 걸림돌이 되고 있다. 따라서 본 논문에서는 처리 속도와 Display의 제한을 대처하기 위하여 모바일 다중처리 시스템과 작업 이양 시스템을 구성하기 위한 하나의 방법론을 제안한다.

  • PDF

Design of Collaborative System for Mobile Remote Medical System (모바일 원격진료시스템을 위한 협력 시스템 설계)

  • Koo Je-Young;Lee Yun-Bae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.1203-1206
    • /
    • 2006
  • 무선 인터넷이 보급됨에 따라 개인 휴대용 단말 장치(PDA)와 같은 모바일 PC를 이용하여 실시간으로 Server에 접속, 의료정보 및 환자 정보 등을 볼 수 있다. 여기서 PDA는 작은 몸체로 이동성 및 편리성 등이 PC보다 뛰어나지만, 처리 속도가 상대적으로 느리기 때문에 해상도가 큰 이미지, 높은 처리 속도를 요구하는 작업 등을 처리하기에는 효율성이 낮은 문제점이 있다. 또한 정보를 Display할 수 있는 액정이 매우 작아서 환자와 관련된 의료 영상 즉, MRI 사진이나 X-ray 사진 등을 자세히 보기에는 현재의 기술력으로는 매우 어렵다. 특히 다수의 PDA와 PC 클라이언트의 데이터 요청으로 인한 서버의 과부하 문제 또한 모바일 진료시스템의 발전에 걸림돌이 되고 있다. 따라서 본 논문에서는 처리 속도와 Display의 제한을 대처하기 위하여 모바일 다중처리 시스템과 작업 이양 시스템을 구성하기 위한 하나의 방법론을 제안한다.

  • PDF

Remote Medical Authentication System on the Mobile Environment (모바일 환경의 원격의료 인증 시스템)

  • 오근탁;김경주;이윤배;이성태;이영신
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.373-375
    • /
    • 2004
  • 오늘날 원격 환경의 진료시스템이 개발되고 있는데, 이들 시스템은 미래의 원격진료 즉, 병원에 직접가지 않고 집에서 바로 혈압, 심박수 등을 검사 받을 수 있는 시스템 개발의 기본이 되고 있다. 그리고 정보통신의 발전으로 모바일 PC 즉, 개인 휴대용 단말기(PDA: Personal Digital Assistants)가 의료분야에서 PC를 대체하여 이동성, 편리성을 제공하는 전자 차트를 선보이고 있다. 그러나 PDA는 작은 몸체로 이동성 및 편리성 등이 PC보다 뛰어나지만, 해상도가 큰 이미지, 높은 처리 속도를 요구하는 작업등을 처리하기에는 효율성이 낮은 문제점이 있다. 또한 정보를 공유 할 수 있는 데이터를 무선 환경으로 처리해야 하기 때문에 환자와 관련된 의료 영상 즉, MRI 사진이나 X-ray 사진 등을 의료 환경에 이용하는 데는 보안의 문제점을 가지고 있다. 따라서 본 논문에서는 매우 빠르게 발전하고 있는 진단과 치료기술을 이러한 의료를 필요로 하는 사랑들에게 제공하는 접근성의 보장 문제를 해결할 수 있는 대안으로 원격의료 인증시스템을 제안 하고자 한다.

  • PDF

PACS Authentication System on the Mobile Environment (무선 환경의 PACS 인증 시스템)

  • Oh, Guan-Tack;Lee, Yun-Bae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.11a
    • /
    • pp.1035-1038
    • /
    • 2005
  • 오늘날 원격 환경의 진료시스템이 개발되고 있는데, 이들 시스템은 미래의 원격진료 즉, 병원에 직접가지 않고 집에서 바로 혈압, 심박수 등을 검사 받을 수 있는 시스템 개발의 기본이 되고 있다. 그리고 정보통신의 발전으로 모바일 PC 즉, 개인 휴대용 단말기(PDA:Personal Digital Assistants)가 의료 분야에서 PC를 대체하여 이동성, 편리성을 제공하는 전자 차트를 선보이고 있다. 그러나 PDA는 작은 몸체로 이동성 및 편리성 등이 PC보다 뛰어나지만, 해상도가 큰 이미지, 높은 처리 속도를 요구하는 작업 등을 처리하기에는 효율성이 낮은 문제점이 있다. 또한 정보를 공유 할 수 있는 데이터를 무선 환경으로 처리 해야 하기 때문에 환자와 관련된 의료 영상 즉, MRI 사진이나 X-ray 사진 등을 의료 환경에 이용 하는 데는 보안 의 문제점을 가지고 있다 따라서 본 논문에서는 매우 빠르게 발전하고 있는 진단과 치료기술을 이러한 의료를 필요로 하는 사람들에게 제공하는 접근성의 보장 문제를 해결할 수 있는 대안으로 무선 환경의 PACS의료 인증시스템을 제안 하고자 한다.

  • PDF