• Title/Summary/Keyword: X-ray 시스템

Search Result 499, Processing Time 0.026 seconds

Development of Test Software Program and Digital Signal Processing Board for Array Module Signal Processing System (Array 검출 모듈 신호처리 시스템의 테스트 소프트웨어 프로그램 개발 및 디지털 신호처리 보드 개발)

  • Park, Geo;Kim, Young-kil;Lee, Jean
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.3
    • /
    • pp.499-505
    • /
    • 2018
  • Shipping and logistics safety, security system is strengthening worldwide, the development of shipping and logistics safety security core technology for national security logistics system construction has been carried out. In addition, it is necessary to localize the Array Detection System, which is a core component of the container search machine, to cope with the 100% pre-inspection of the container scheduled for 2018 in the United States. In this research, we propose a test software program developed by using TI-RTOS (Texas Instruments - Real Time Operating System) with a test digital signal processing board which is developed self development. We have developed a program that can test GPIO, SRAM, TCP/IP, and SDcard using M4 MCU. Also we propose a study on a self-developed Digital Signal Processing Board among the array detection systems that replace foreign products. We have developed a test board that can test M4 MCU and developed an X-Ray Detector Digital Signal Processing Board that combines MCU and FPGA.

Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species (Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1))

  • Song, Jung Il;Kim, Han Seul
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.220-231
    • /
    • 2021
  • The use of digital copies of film-based analog images and the introduction of digital radiographic imaging systems using image plates gradually replace the non-destructive radiationirradiation method of Cultural Heritage. The quality of images obtained from this technique is affected by conditions such as tube voltage, tube current, and exposure time, type of image acquisition medium, distance of the artifacts from the image acquisition medium, and thickness of artifacts. In this study, we evaluated the grayscale image obtained using GE's Computed Radiograhpy (CR) imaging system, the transmission characteristics of the X-ray source for each tree type (pine, chestnut, sawtooth oak, ginkgo) used in wooden Cultural Heritage, and the signal-to-noise ratio (SNR) and contrast. The GE's CR imaging were analyzed using the Duplex wire image quality indicator, line-pair gauges.

Improvement of Physical security System Operation (물리적 보안시스템 운용수준 분석)

  • Chung, Taehwang
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.2
    • /
    • pp.282-286
    • /
    • 2014
  • This study is to present an improvement of physical security system operation by survey on the install and operation of physical security system of 90 facilities. The level of CCTV operation is higher than Access Control system and Intrusion Detection System. But the level of maintenance and management of physical security system is low. The rate of install of X-ray Inspection device show the concern on material detection, although the rate is low. The level of install and operation for the Integration of physical security system is low, so integration of security personnel and security system is necessary for the effective operation. For reinforcement of access control management, security gate and preparing of some obstacles are required with RFID.

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.

Development of Next Medical Imaging System beyond MRI (POST MRI 시대를 위한 3차원 차세대 의료영상기술 개발)

  • Hong, H.B.;Shin, S.W.;Park, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.29 no.5
    • /
    • pp.96-104
    • /
    • 2014
  • 1895년 독일 과학자 Wilhelm Roentgen 박사가 X-ray를 발견하고 미국의 Herman Carr가 MRI(Magnetic Resonance Imaging)의 기본 원리를 개발하여 발표한 이후 전자기장을 이용한 비침습적 의료영상 이미지 시스템은 놀라운 발전을 계속하여 왔다. 하지만, X-ray, CT(Computed Tomography), PET(Positron Emission Tomography)의 경우는 방사능의 사용과 조영제의 독성이라는 문제로 인하여 안전성에 대한 계속적인 문제를 야기해왔고 상대적으로 안전성이 입증된 MRI의 경우는 장비 자체 및 운용비가 일반화되기에는 고가여서 우리나라를 포함한 선진국에서도 아주 제한적으로 운영되고 있는 실정이다. 따라서, 세계적으로도 이러한 문제를 해결하기 위하여 안전하면서도 상대적으로 저렴한 비용으로 운용이 가능한 의료영상장비를 개발하기 위하여 많은 노력들이 경주되고 있어 관련 연구동향 및 산업화 동향을 소개하고자 한다.

  • PDF

Displacement measurement in nanometer region and calibration of transducers using combined optical and x-ray interferometer (광/엑스선 복합간섭계를 이용한 나노미터 영역의 변위 측정 및 trnasducer의 비선형 교정)

  • Park Jin-Won;Jo Jae-Gun;Byun Sang-Ho;Eom Cheon-Il
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.515-518
    • /
    • 2005
  • 현재 정밀한 길이를 측정하기 위해서는 광 간섭계를 이용한 측정기술이 주로 사용되어지고 있다. 이러한 광 간섭계의 발전과 더불어 이보다 더 높은 분해능을 얻기 위해 광파장보다 1000배 정도 짧은 엑스선을 이용한 변위 측정 기술개발이 진행되고 있다. 본 연구에서는 이러한 엑스선을 이용한 간섭계를 제작하고, 광 간섭계와 결합된 광/엑스선 복합간섭계를 구성하여 광 간섭계가 안고 있는 자체의 비선형성이 제거된 정밀 변위 측정 시스템을 구성하였다. 그 응용으로써, 제작된 광/엑스선 복합간섭계를 이용하여 나노미터 영역에 서 사용하는 transducer의 비선형성을 측정하였다.

  • PDF

(Various Electionic system Applications by Using Silicon-based Thin Films) (실리콘계 박막을 이용한 다양한 전자시스템 응용)

  • 이준신
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.186.2-189
    • /
    • 2001
  • 요실리콘을 기반으로 하는 박막은 반도체 재료로 Si, Si:Ge, SiC등이 사용되고있으며, 절연박막재료로 SiN, SiOxNy, SiOx 등이 있다. 이들 재료는 국내 반도체 산업의 핵심위치에 있는 물질이다. 한국 산업의 근간이라 할 수 있는 메모리분야에 적용될 뿐만 아니라 TFT-LCD, 태양전지, 각종 센서, X-ray 사진 촬영기 개발에도 응용되고 있다. 본 논문에서는 Silicon-based 박막의 제조기법과 그에 따른 다양한 실리콘 박막 실리콘 트랜지스터를 이용한 능동형 액정과 유기발광 화소제어 활용, 센서 응용 부분에서 태양전지, X-ray 촬영기활용 분야에서 기술현황 시장분석을 통해 차세대 연구개발의 방향을 제시하고자 한다. 현재 국내에서 실리콘 박막의 가장 큰 응용 분야는 메모리 소자의 평판디스플레이의 TFT-LCD 시장이다. 그러나 실리콘 박막으로 가능한 응용분야는 아직 산업계에서 열매를 맺지 못한 분야가 더 많고 실제로 적용할 수 있는 분야의 다양함을 본 논문을 통해 소개한다.

  • PDF

A Study on the Improvement of Import Clearance System for Express Consignments by Increase of Electronic Commerce (전자상거래 확대에 따른 특송물품 수입통관시스템의 개선방안에 관한 연구)

  • Song, Seon-Uk
    • International Commerce and Information Review
    • /
    • v.6 no.3
    • /
    • pp.183-201
    • /
    • 2004
  • Recently, Electronic commerce market is growing sharply for the expansion of internet and development of means of air transportation. Import Clearance System for express consignments, introduced in Korea, confers some benefit upon express consignments, ie. prompt clearance, simplification of the clearance procedure, exemption of necessary documents. But it has some problems such as lack of social security and trade compliance. So it requires some improvements as follows. Firstly, it has no legal background to clear all articles valued at US$100 or less carried by an express consignment operator. So customs brokers, not express consignment operators, should clear that articles. Secondly, it should be presented necessary documents including commercial invoice to prevent a wrong price declaration in entering express consignments valued at US$100 or less. Thirdly, X-ray inspectors must enhance their inspection ability. Customs must provide education programs for X-ray inspectors to improve their inspection ability. Lastly, Cargo selectivity system for express consignments have to be improved to operate effectively.

  • PDF

Computer-Aided Diagnosis System for the Detection of Breast Cancer (유방암검출을 위한 컴퓨터 보조진단 시스템)

  • Lee, C.S.;Kim, J.K.;Park, H.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.319-322
    • /
    • 1997
  • This paper presents a CAD (Computer-Aided Diagnosis) system or detection of breast cancer, which is composed of personal computer, X-ray film scanner, high resolution display and application softwares. There are three major algorithms implemented in the application software. The irst algorithm is the adaptive enhancement of the digitized X-ray mammograms based on the first derivative and the local statistics. The second one is to detect the clustered microcalcifications by using the statistical texture analysis, and the third one is the classification of the clustered microcalcifications as malignant or benign by using the shape analysis. These algorithms were verified by real experiments.

  • PDF

Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System (Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF