• 제목/요약/키워드: X-probe

검색결과 610건 처리시간 0.028초

동축 슬롯 선로를 이용한 기준 용액들의 이동 통신 주파수帶에서의 복소 유전율 측정 (Complex Permittivity Measurement using a Coaxial Slotted Line of Reference Liquids at Mobile Communication Frequencies)

  • 김정호;김윤명
    • 한국전자파학회논문지
    • /
    • 제14권9호
    • /
    • pp.955-960
    • /
    • 2003
  • 본 논문에서는 이동 가능한 프로브(probe)가 있는, 종단된 동축 슬롯 선로(Coaxial slotted line)를 샘플 液의 흘더로 사용하여, 이동 통신 단말기 의 송신 주파수帶에서의 복소 유전율을 측정할 수 있는 시스템을 제작하였으며, 이를 이용하여 IEEE Std 1528-200X에 서 제안한 기준 액체들(Reference Liquids)의 복소 유전율을 측정 비교하여 봄으로써, 측정 시스템의 타당성을 조사하였다.

Experimental Investigation on the Turbulence Augmentation of a Gun-type Gas Burner by Slits and Swirl Vanes

  • Kim, Jang-kweon
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1819-1828
    • /
    • 2004
  • The purpose of this paper is to investigate the effects of slits and swirl vanes on the turbulence augmentation in the flow fields of a gun-type gas burner using an X-type hot-wire probe. The gun-type gas burner adopted in this study is composed of eight slits and swirl vanes located on the surface of an inclined baffle plate. Experiment was carried out at a flow rate of 450 ι/min in burner model installed in the test section of subsonic wind tunnel. Swirl vanes playa role diffusing main flow more remarkably toward the radial direction than axial one, but slits show a reverse feature. Consequently, both slits and swirl vanes remarkably increase turbulence intensity in the whole range of a gun-type gas burner with a cone-type baffle plate.

Low-Z Electron Probe X-ray Microanalysis를 이용한 불균일 NaCl-Na$_2$SO$_4$ 입자의 분석 (Characterization of Heterogeneous NaCl-Na$_2$SO$_4$ Particles Using Low-Z Electron Probe X-ray Microanalysis)

  • 구희준;안용훈;김혜경;노철언
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.394-395
    • /
    • 2003
  • 대기 중의 황산염 입자는 인체 건강에 좋지 않은 영향을 미칠 뿐 아니라, 지구에 유입되는 빛을 산란시키고 구름을 생성하는 핵으로 작용함으로서 직ㆍ간접적으로 햇빛을 차단하여 전지구적 기후 변화에 상당한 역할을 하는 것으로 알려져 있다. 황산염 입자는 대기 중 SO$_2$의 산화에 의해 주로 생성되는데, 지금까지의 대기 모델을 활용한 연구에 의하면 대기 중의 SO$_2$의 양에 비해 황산염의 양은 과소 평가되고 있다. 이는 대기 중 황산염의 생성에 대한 대기 화학 반응기전이 제대로 파악되지 않아서 global scale의 예측이 불확실하기 때문이다. (중략)

  • PDF

Low-Z Electron Probe X-ray Microanalysis를 이용한 서울시 대기 중 입자상 물질 분석 (Single particle characterization of atmospheric aerosol particles collected in Seoul, using low-Z electron probe X-ray microanalysis)

  • 구희준;노철언;김혜경
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2002년도 추계학술대회 논문집
    • /
    • pp.352-353
    • /
    • 2002
  • 최근 산업이 발달함에 따라 수도권을 비롯한 도시에서의 인구집중과 증가로 인한 운행 차량 수의 증가, 산업규모의 확대 둥으로 인해 대기분진 중 호흡성 또는 미세분진 농도의 증가가 관찰되고 있으며 이로 인한 주민건강 위해의 가능성이 제기되고 있다. 2.5$\mu\textrm{m}$ 이하의 미세 입자는 폐포내 침착율이 높으며, 유해성 가스 및 중금속을 쉽게 흡착하여 인체에 전달하는 매체가 되기도 하고, 빛을 흡수, 산란시키기 때문에 시정을 악화.시킨다. 따라서 도시대기의 입자상 물질의 물리적, 화학적 특성에 대해서 많은 연구가 진행되어 왔다. (중략)

  • PDF

X-ray Micro-Imaging 기법 소개 및 불투명 튜브 내부의 마이크로 버블 가시화 연구 (X-ray Micro-Imaging Technique and Its Application to Micro-Bubbles in an Opaque Tube)

  • 이상준;김석;백부근
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.31-34
    • /
    • 2002
  • Imaging techniques using x-ray beam at high energies (>6KeV) such as contact radiography, projection microscopy, and tomography have been used to nondestructively discern internal structure of objects in material science, biology, and medicine. This paper introduces the x-ray micro-imaging method using 1B2 micro-probe line of PAL (Pohang Accelerator Laboratory). Cross-sectional information on low electron density materials can be obtained by probing a sample with coherent synchrotron x-ray beam in an in-line holography setup. Living organism such as plants, insects are practically transparent to high energy x-rays and create phase shift images of x-ray wave front. X-ray micro-images of micro-bubbles of $20\~120\;{\mu}m$ diameter in an opaque tube were recorded. Clear phase contrast images were obtained at Interfaces between bubbles and surrounding liquid due to different decrements of refractive index.

  • PDF

Preparation, Structure, and Photoemission Studies on the High Temperature Superconductor $YBa_2Cu_{3-x}Ni_xO_{7-{\delta}}$

  • Choy, Jin-Ho;Choe, Won-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제11권5호
    • /
    • pp.379-383
    • /
    • 1990
  • $YBa_2Cu_{3-x}Ni_xO_{7-{\delta}}$, with x = 0.05, 0.2, 0.4, 0.7 and 1.0 had been prepared by the thermal decomposition of corresponding nitrates. Among them, the sample with x = 0.05 shows above-liquid-$N_2$ temperature superconductivity with $T_c$ of 88.7K. According to the X-ray diffraction analysis, its crystal symmetry was estimated as orthorhombic with the lattice parameters of a = 3.866${\AA}$, b = 3.893${\AA}$, c = 11.715${\AA}$. The chemical composition of the sample was determined by electron probe microanalysis and the chemical composition around its grain boundaries was carefully studied by the X-ray line scanning technique. From the observed binding energy of Ni-$2p_{3/2}$ orbital electron (B.E. = 853 eV) measured by X-ray photoelectron spectroscopy, the valency state of nickel stabilized in $YBa_2Cu_{2.95}Ni_{0.05}O_{7-{\delta}}$ oxide lattice could be determined to be Ni(II).

A High-speed Atomic Force Microscope for Precision Measurement of Microstructured Surfaces

  • Cui, Yuguo;Arai, Yoshikazu;Asai, Takemi;Ju, BinFeng;Gao, Wei
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.27-32
    • /
    • 2008
  • This paper describes a contact atomic force microscope (AFM) that can be used for high-speed precision measurements of microstructured surfaces. The AFM is composed of an air-bearing X stage, an air-bearing spindle with the axis of rotation in the Z direction, and an AFM probe unit. The traversing distance and maximum speed of the X stage are 300 mm and 400 mm/s, respectively. The spindle has the ability to hold a sample in a vacuum chuck with a maximum diameter of 130 mm and has a maximum rotation speed of 300 rpm. The bandwidth of the AFM probe unit in an open loop control circuit is more than 40 kHz. To achieve precision measurements of microstructured surfaces with slopes, a scanning strategy combining constant height measurements with a slope compensation technique is proposed. In this scanning strategy, the Z direction PZT actuator of the AFM probe unit is employed to compensate for the slope of the sample surface while the microstructures are scanned by the AFM probe at a constant height. The precision of such a scanning strategy is demonstrated by obtaining profile measurements of a microstructure surface at a series of scanning speeds ranging from 0.1 to 20.0 mm/s.

Spatial Distributions of Alloying Elements Obtained from Atom Probe Tomography of the Amorphous Ribbon Fe75C11Si2B8Cr4

  • Shin, Jinkyung;Yi, Seonghoon;Pradeep, Konda Gokuldoss;Choi, Pyuck-Pa;Raabe, Dierk
    • 한국재료학회지
    • /
    • 제23권3호
    • /
    • pp.190-193
    • /
    • 2013
  • Spatial distributions of alloying elements of an Fe-based amorphous ribbon with a nominal composition of $Fe_{75}C_{11}Si_2B_8Cr_4$ were analyzed through the atom probe tomography method. The amorphous ribbon was prepared through the melt spinning method. The macroscopic amorphous natures were confirmed using an X-ray diffractometer (XRD) and a differential scanning calorimeter (DSC). Atom Probe (Cameca LEAP 3000X HR) analyses were carried out in pulsed voltage mode at a specimen base temperature of about 60 K, a pulse to base voltage ratio of 15 %, and a pulse frequency of 200 kHz. The target detection rate was set to 5 ions per 1000 pulses. Based on a statistical analyses of the data obtained from the volume of $59{\times}59{\times}33nm^3$, homogeneous distributions of alloying elements in nano-scales were concluded. Even with high carbon and strong carbide forming element contents, nano-scale segregation zones of alloying elements were not detected within the Fe-based amorphous ribbon. However, the existence of small sub-nanometer scale clusters due to short range ordering cannot be completely excluded.

원발성 무월경 여성에서 관찰된 Pseudoisodicentric X 염색체 (Pseudoisodicentric X chromosome in a female with primary amenorrhea)

  • 박상희;심성한;진미욱;강수진;배성미;손수민;차동현;윤태기;조정현
    • Journal of Genetic Medicine
    • /
    • 제5권1호
    • /
    • pp.61-64
    • /
    • 2008
  • 24세의 무월경을 주소로 내원한 여성에게서 세포유전학적 검사를 시행하였다. GTG-분염법 결과, 환자의 핵형이 46,X,der(X)로 관찰되어 LSI Kallmann(KAL) 형광소식자[probes for Xp22.3 (KAL)과 CEP(X) for control]로 FISH 분석을 시행하였다. 비정상 X 염색체에서는 KAL (Xp22.3)에 대한 형광이 보이지 않았고, CEP(X)에 대한 형광이 두 개씩 관찰되었다. 간기세포 FISH 분석 결과, CEP(X) 형광소식자에 대해 분석한 세포의 90%에서 세 개의 형광이, 10%의 세포에서 하나의 형광이 관찰되어 두가지 cell line이 혼재되어 있는 모자이시즘을 확인하였다. 이들 결과들을 통해 환자의 핵형이 45,X/46,X,psu idic(X)(p22.1)이며, 이는 Xqter${\rightarrow}$Xp22.1 부분은 중복되어 있고, Xpter${\rightarrow}$Xp22.1 부분은 결실된 상태로 터너 증후군의 변형된 형태임을 판명하였다. Idic(X)와 낮은 비율의 모자이시즘을 확인하는데 CEP(X) 형광소식자로 FISH를 시행하는 것이 유용하였다.

  • PDF