• Title/Summary/Keyword: X-joint

Search Result 595, Processing Time 0.034 seconds

Studies on the Knee Joint Pain (무릎관절의 통증에 관한 연구)

  • Choe, Joon-Rieb;Lee, Hee-Jeon;Choe, Wook-Yoen;Han, Sang-Yoen
    • The Korean Journal of Pain
    • /
    • v.5 no.2
    • /
    • pp.249-257
    • /
    • 1992
  • It is general knowledge that knee joint pain can be attributed to trauma and degenerative change around the knee joint. However most patients who have suffered from pain or limited range of motion of the knee joint show no definite pathology on X-ray or laboratory examination. We examined 242 patients with knee joint pain and found compression or entrapment of the articular nerve fiber by the tissue around the knee joint resulted in pain in almost all cases. Conclusion: by relieving the compression of the articular nerve fiber with just physical therapy and LASER stimulation on the identified trigger points, in conjunction with NSAIDs, muscle relaxants, were found to be very effective in the treatment of knee joint pain.

  • PDF

Analysis of Angular Deformation in Multi-pass Butt Joint Welding of Thick Plates with X-shape Grooves using the Finite Element Method (X형 개선을 가진 후판 맞대기 용접에 있어서 유한요소법을 이용한 각변형 해석)

  • Yang, Young-Soo;Bae, Kang-Yul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.169-176
    • /
    • 2018
  • Removal of angular deformation induced during the welding of butt joints in thick steel plates needs expert skill and is costly. To reduce deformation, proper joint designs are studied with a prediction of deformation prior to welding. However, as the thickness of a plate increases, a predictive analysis of the welding process is more difficult, especially if there is an increase in the number of welding passes in the joint. In this study, a numerical model with the finite element method (FEM) was developed to analyze the angular deformation in the multi-pass welding of butt joints of plates made of AH32 steel that had a thickness of up to 100 mm. A series of numerical simulations were then performed based on the developed model to predict the deformations for thick plates. With the results obtained by the analyses, this study suggested optimal X-shape grooves for the butt joints of thick plates to minimize the angular deformation. As the thickness of the plate increased to 100 mm, the ratio of the depth of the front-side groove to that of the back-side groove should be gradually increased to nearly 1:3.

Anatomic reconstruction for acromioclavicular joint injuries: a pilot study of a cost-effective new technique

  • Pattu, Radhakrishnan;Chellamuthu, Girinivasan;Sellappan, Kumar;Kamalanathan, Chendrayan
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.4
    • /
    • pp.209-214
    • /
    • 2021
  • Background: The treatment for acromioclavicular joint injuries (ACJI) ranges from a conservative approach to extensive surgical reconstruction, and the decision on how to manage these injuries depends on the grade of acromioclavicular (AC) joint separation, resources, and skill availability. After a thorough review of the literature, the researchers adopted a simple cost-effective technique of AC joint reconstruction for acute ACJI requiring surgery. Methods: This was a prospective single-center study conducted between April 2017 and April 2018. For patients with acute ACJI more than Rockwood grade 3, the researchers performed open coracoclavicular ligament reconstruction using synthetic sutures along with an Endobutton and a figure of 8 button plate. This was followed by AC ligament repair augmenting it with temporary percutaneous AC K-wires. Clinical outcomes were evaluated using the Constant Murley shoulder score. Results: Seventeen patients underwent surgery. The immediate postoperative radiograph showed an anatomical reduction of the AC joint dislocation in all patients. During follow-up, one patient developed subluxation but was asymptomatic. The mean follow-up period was 30 months (range, 24-35 months). The mean Constant score at 24 months was 95. No AC joint degeneration was noted in follow-up X-rays. The follow-up X-rays showed significant infra-clavicular calcification in 11 of the 17 patients, which was an evidence of a healed coracoclavicular ligament post-surgery. Conclusions: This study presents a simple cost-effective technique with a short learning curve for anatomic reconstruction of acute ACJI. The preliminary results have been very encouraging.

Staistical analysis and measurements of array receivers for use in optical communication (광통신에 이용되는 배열 수신기의 측정과 통계적 해석)

  • Sung, Pyung-Shik
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.1
    • /
    • pp.57-64
    • /
    • 2007
  • In the paper, considers the design of a detection system, consisting of n identical detectors, to process the sum of spatially invariant signal fields $S_\jmath(t)$, an additive, homogeneous, spatially isotropic (in the array plane x). covariance_separable, and zero_mean Gaussian random noise field n(t, x). consisting of arrey receivers for use in optical communication through optimum turbulence atmosphers and covriance_circuit, staistical analysis through detection the maximum gain are compared with analysis theoretical analysis theoretical value and get through experimental measured value, as well the measured valus are confirmed to agreement joint Gaussian theoretical curves.

  • PDF

A Study on Automatic Seam Tracking of Arc Welding Using an Laser Displacement Sensor (레이져 변위센서를 이용한 용접선 자동추적에 관한 연구(2))

  • 양상민;조택동;전진환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.729-733
    • /
    • 1997
  • Due to the variety of disturbance, it is not ease to accomplish the in-process detection of weld line with non-contact sensor. To get around this difficulties problem develop an automatic seam tracking weld system, the reliable signal processing algorithm has been recommanded. In this research, laser displacement sensor is applied as a seam finder in the automatic tracking system. The sensor is controlled by a dc servo motor which is mounted at X-Y moving table. X-Y moving table manipulated by an ac servo motor controls the position and velocity of the welding torch. First, X-Y table moves to Y-axis to search the welding joint feature before starting the welding, and welding joint is from the scanning data and weighting factor for each other. Second, weld line is determined using proposed signal processing algorithm during welding process. Form the experimental results, we could see the possibility that laser displacement sensor with procesed algorithm can be used as a seam finder in welding process under the severe noise (spatter,arc light etc.) condition

  • PDF

Evaluation of Residual Stress on Welded Joint in API X65 Pipe Line through Nondestructive Instrumented Indentation Technique (비파괴 계장화 압입시험기법을 통한 API X65 배관 용접부 잔류응력 평가)

  • 지원재;이윤희;김우식;김철만;권동일
    • Journal of Welding and Joining
    • /
    • v.21 no.5
    • /
    • pp.547-554
    • /
    • 2003
  • Apparent mechanical properties in structural components can be different from the initially designed values due to the formation of the residual stress in metal forming and welding. Therefore, the evaluation of residual stress has great importance in the reliability diagnosis of structural components. A nondestructive instrumented indentation technique has been proposed to evaluate various strength concerning mechanical properties from the analysis of load-depth curve. In this study, quantitative residual stress estimation on API X65 welded joints for natural gas pipeline was performed by analyzing the variation of indentation loading curve by residual stress through a new proposed theoretical model. The residual stress from the indentation method was compared with that from the saw-cutting method.

Flexural behavior and resistance of uni-planar KK and X tubular joints

  • Chen, Yiyi;Wang, Wei
    • Steel and Composite Structures
    • /
    • v.3 no.2
    • /
    • pp.123-140
    • /
    • 2003
  • The importance of the research on moment-resistant properties of unstiffened tubular joints and the research background are introduced. The performed experimental research on the bending rigidity and capacity of the joints is reported. The emphasis is put on the discussion of the flexural behavior of the joints including sets of geometrical parameters of the joints and several loading combinations. Procedures and results of loading tests on four full size joints in planar KK and X configuration are described in details at first. Mechanical models are proposed to analyze the joint specimens. Three-dimensional nonlinear FE models are established and verified with the experimental results. By comparing the experimental data with the results of the analysis, it is reported reasonable to carry out the structural analysis under the assumption that the joint is fully rigidly connected, and their bending capacities can assure the strength of the members connected under certain limitation. Furthermore, a parametric formula for inplane bengding rigidity of T and Y type tubular joints is proposed on the basis of FE calculation and regression analysis. Compared with test results, it is shown that the parametric formula developed in this paper has good applicability.

Seismic behavior of reinforced concrete interior beam-column joints with beams of different depths

  • Xing, G.H.;Wu, T.;Niu, D.T.;Liu, X.
    • Earthquakes and Structures
    • /
    • v.4 no.4
    • /
    • pp.429-449
    • /
    • 2013
  • Current Design Codes for Reinforced Concrete (RC) interior beam-column joints are based on limited experimental studies on the seismic behavior of eccentric joints. To supplement existing information, an experimental study was conducted that focused on the effect of eccentricity of the deeper beams with respect to the shallow beams. A total of eight one-third scale interior joints with beams of different depths were subjected to reverse cyclic loading. The primary variables in the test specimens were the amount of joint transverse reinforcement and the cross section of the shallow beams. The overall performance of each test assembly was found to be unsatisfactory in terms of joint shear strength, stiffness, energy dissipation and shear deformation. The results indicated that the vertical eccentricity of spandrel beams in this type of joint led to lower capacity in joint shear strength and severe damage of concrete in the joint core. Increasing the joint shear reinforcement was not effective to alter the failure mode from joint shear failure to beam yielding which is favorable for earthquake resistance design, whereas it was effective to reduce the crack width at the small loading stages. Based on the observed behavior, the shear stress of the joint core was suggested to be kept as low as possible for a safe and practical design of this type of joint.

A comparative study on keypoint detection for developmental dysplasia of hip diagnosis using deep learning models in X-ray and ultrasound images (X-ray 및 초음파 영상을 활용한 고관절 이형성증 진단을 위한 특징점 검출 딥러닝 모델 비교 연구)

  • Sung-Hyun Kim;Kyungsu Lee;Si-Wook Lee;Jin Ho Chang;Jae Youn Hwang;Jihun Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.460-468
    • /
    • 2023
  • Developmental Dysplasia of the Hip (DDH) is a pathological condition commonly occurring during the growth phase of infants. It acts as one of the factors that can disrupt an infant's growth and trigger potential complications. Therefore, it is critically important to detect and treat this condition early. The traditional diagnostic methods for DDH involve palpation techniques and diagnosis methods based on the detection of keypoints in the hip joint using X-ray or ultrasound imaging. However, there exist limitations in objectivity and productivity during keypoint detection in the hip joint. This study proposes a deep learning model-based keypoint detection method using X-ray and ultrasound imaging and analyzes the performance of keypoint detection using various deep learning models. Additionally, the study introduces and evaluates various data augmentation techniques to compensate the lack of medical data. This research demonstrated the highest keypoint detection performance when applying the residual network 152 (ResNet152) model with simple & complex augmentation techniques, with average Object Keypoint Similarity (OKS) of approximately 95.33 % and 81.21 % in X-ray and ultrasound images, respectively. These results demonstrate that the application of deep learning models to ultrasound and X-ray images to detect the keypoints in the hip joint could enhance the objectivity and productivity in DDH diagnosis.

Three-Dimensional Characterizing Analysis of Astronomic CCDs with a deep depletion (깊은 공핍층을 가지는 우주항공용 촬상소자의 3 차원 특성 분석)

  • Kim, M. H.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.228-229
    • /
    • 2000
  • Buried channel JET-X CCDs (Joint European X-ray Telescope Charge Coupled Devices: EEV CCD12) with a deep depletion have been analyzed to provide an optimized condition for a charge storage and transfer. A maximum charge capacity has been found for the supplementary narrow channel by considering the potential distribution as a function of a mobile charge. Analysis for the depletion edges of JET-X CCDs have been successfully performed, showing good agreement with the depths estimated from X-ray detection efficiency measurements [1]. (omitted)

  • PDF