• Title/Summary/Keyword: X-intercept

Search Result 20, Processing Time 0.026 seconds

Relationship of Fixation Disparity and Heterophoria According to Fixation Distance (원, 근거리에서 주시시차와 사위와의 관계)

  • Kim, Chang-Jin;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • Purpose: This study measured Y-intercept that means a fixation disparity, X-intercept that means a associated phoria and slope of a fixation disparity curve (FDC), which are variables of dissociated phoria and the FDC. We searched for the result value and examined the direction, distribution pattern and a variable that give an most affect on dissociated phoria and the FDC at distance and near. Also this study examined that there were statistically significant differences between distance and near, comparing the result value. Methods: We measured the dissociated phoria and the fixation disparity for 51 subjects at distance and near in June, 2007. All subjects ranged from 20 to 25 years of age (average 21.72${\pm}$1.88 years old) and had no eye disease. At distance the dissociated phoria measured with the distance MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the modified Mallett Far Unit (Bernell co., USA). At near the dissociated phoria measured with the near MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the Wesson fixation disparity card (American Optical co., USA). Results: The percentage distribution of types of fixation disparity curves was that at distance prevalence of Type I (74.6%) was the highest, followed by Type IV (17.6%) and Type II (3.9%), Type III (3.9%) and that at near prevalence of Type I (53.0%) was the highest, followed by Type III (29.4%), Type IV (13.7%) and Type II (3.9%). 2. There were significantly correlation in dissociated phoria, fixation disparity (Y-intercept) and associated phoria (X-intercept). 3. The fixation disparity at distance was most affected by associated phoria (X-intercept) (p=0.000). The distance dissociated phoria was most affected by fixation disparity (Y-intercept) (p=0.342), but the influence was weak. 4. The fixation disparity at near was most affected by associated phoria (X-intercept) (p=0.000). The near also dissociated phoria was most affected by associated phoria (X-intercept) (p=0.009). The result that compared the each variables with the same variables at distance and near had statistically significant on paired t-test for among dissociated phoria (t=7.529, p=0.000), X-intercept (t=5.860, p=0.000), the Y-intercept (t=4.640, p=0.000) but slope of the FDC did not differ significant (t=1.336 p=0.188). Conclusions: Relationship of fixation disparity and Heterophoria had close correlation at distance and near.

  • PDF

The Study of Vertical Fixation Disparity by Fixation Disparity Card (주시시차 카드를 이용한 수직주시시차 연구)

  • Park, Hyun-Ju;Yoon, Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: This study was performed to determine vertical fixation disparity by Fixation Disparity Card. The purpose of this study was to investigate distribution of the curve types obtained with Wesson card. Methods: Fixation disparity curves were measured on 52 subjects with the Wesson fixation disparity card. A fixation disparity curve was an x, y coordinate plot of the angular amount of fixation disparity as a function of the power of prisms through which the patient views. The fixation disparity curve variables that were used to aid in the diagnosis and management of binocular vision disorders included the x-intercept, y-intercept, curve slope and curve type. Results: Vertical fixation disparity curves by Wesson Fixation Disparity Card were very various. Conclusions: Vertiical fixation disparity curves could be used to aid in the diagnosis and prescription.

Analysis of Binocular Vision by Wesson Fixation Disparity Card (Wesson Fixation Disparity Card를 이용한 양안시 분석)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • A commonly used device to determine fixation disparity curves is the Wesson Fixation Disparity Card. A fixation disparity curve is an x, y coordinate plot of the angular amount of fixation disparity as a function of the power of prisms through which the patient views. The fixation disparity curve variables that are used to aid in the diagnosis and management of binocular vision disorders include the x-intercept, y-intercept, curve slope and curve type. Fixation disparity curves were measured on 102 subjects with the Wesson fixation disparity card. The purpose of this study is to investigate distribution of the curve types obtained with Wesson card. Fixation Disparity by Wesson Fixation Disparity Card were that in case of type I 63.0%, in case of type II 0.0%, in case of type III 25.0% and in case of type IV 12.0%.

  • PDF

T/R Module Development for X-Band Active Phased-Array Radar (능동 위상 배열 레이더용 X-대역 T/R 모듈 개발)

  • Kim, Dong-Yoon;Chong, Min-Kil;Kim, Sang-Keun;Chon, Sang-Mi;Na, Hyung-Gi;Baik, Seung-Hun;Ahn, Chang-Soo;Kim, Seon-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1243-1251
    • /
    • 2009
  • This paper presents design and test results of X-Band Transmit/Receive(T/R) module for active phased-array radar. Active phased array radars typically require solid state T/R modules with high output power, low noise figure, high Third Order Intercept(TOI), and sufficient gain in both transmit and receive. The output power of the module is 9 watts over a wide bandwidth. The noise figure is as low as 2.8 dB. Phase and amplitude are controlled by the 6-bit phase shifter and 5-bit attenuator, respectively. Highly integrated T/R module is achieved by using LTCC(Low Temperature Co-fired Ceramic) multiple layer substrate. The module incorporates a compact digital interface, requires only three supply voltages.

Minimum time Algorithm for intercepting a Moving Object on Conveyor System (컨베이어 상의 이동 물체 획득을 위한 로봇의 최소시간 알고리즘)

  • Shin, Ik-Sang;Moon, Seung-Bin B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.526-528
    • /
    • 2004
  • This paper focuses on planning strategies for object interception, especially with minimum time. Herein, the goal is for robot to intercept object with minimum time on a conveyor line that flows to x-axis with respect to world coordinate system. In order to do it, conveyor system needs the algorithms for minimizing time. This objective is achieved by solving about two problems: selection of a minimum-time interception point and planning of an optimal robot trajectory. Herein, the first problem is formulated a minimization of the robot-object interception time.

  • PDF

APPLICATION STUDY OF CHEMOINFOMETRICAL NEAR-INFRARED SPECTROSCOPY IN PHARMACEUTICAL INDUSTRY

  • Otsuka, Makoto;Kato, Fumie;Matsuda, Yoshihisa
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2111-2111
    • /
    • 2001
  • A chemoinfometrical method for evaluating the quantitative determination of crystallinity one polymorphs based on fourie-transformed near-infrared (FT-NIR) spectroscopy was established. A direct comparison of the data with the ones collected from using the and compared with the conventional powder X-ray diffraction method was performed. [Method] The pPure a and g forms of indomethacin (IMC) were prepared by reportedusing published methods. Six kinds of standard samples obtained by physically mixing of a and g forms. After the powder X-ray diffraction profiles of samples have been measured, the intensity values were normalized to against the intensity of silicon powder as the as an external standard. The calibration curves for quantification of crystal content were based upon the total relative intensity of four diffraction peaks from of the form g crystal. FT-NIR spectra of six calibration sample sets were recorded 5 times with the NIR spectrometer (BRAN+LUEBBE). Chemoinfometric analysis was performed on the NIR spectral data sets by applying the principal component regression (PCR). [Results] The relation between the actual and predicted polymorphic contents of form g IMC measured using by the X-ray diffraction method shows a good straight linen linear relation., and it has slope of 0.023, an intercept of 0.131 and a correlation coefficient of 0.986. PCR analyses wereis was performed based on normalized NIR spectra sets offer standard samples of known content of IMC g form. IMC. A calibration equation was determined to minimize the root mean square error of the predictionthe prediction. Figure 1 shows a plot of the calibration data obtained by NIR method between the actual and predicted contents of form g IMC. The predicted values were reproducible and had a smaller standard deviation. Figure 2 shows that the plot for the predicted transformation rate (%) of form a IMC to form g as measured by X-ray diffractomeoy against to those as measured by NIR method. The plot has a slope of 1.296, an intercept of 1,109, and a correlation coefficient of 0.992. The line represents a satisfactory correlation between the two predicted values of form g IMC content. Thus NIR spectroscopy is an effective method for the evaluation to the pharmaceutical products of quantitative of polymorph.

  • PDF

A Study of Parallel Test Among Three ADVIA 2120 System (3대의 ADVIA 2120 System 평행시험에 대한 연구)

  • Chang, Sang-Wu;Cho, Eun-Hae;Kim, Nam-Yong;Chu, Kyung-Bok;Lee, Suk-Jong;Hong, Sung-No;Oh, Jong-Do
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.1
    • /
    • pp.16-21
    • /
    • 2006
  • Parallel testing means ordering a number of tests at the same time so abnormalities in any of the tests can be found quickly and used in making the diagnosis. This is a good medical strategy to eliminate diseases and it is relatively inexpensive if all the tests are potential sources of information and performed on the same analyzer. In regression, the equation for the straight line is recast as y = bx + a. This change in terminology leads to confusion. Here a is the y-intercept or constant and b is the coefficient or slope of the line. A few more words of caution about regression - as in all of statistics there are certain assumptions: the x value is a true measure, both X and Y distributions are normal, and homoscedasticity, i.e., the variance of y is the same for each value of x. In this study the linearity classification made by different scientists were always in agreement. Typical examples of curves that were considered linear are presented in Fig. 1-5. Because these automated procedures values were usually within five percent of each other the curvature could be easily detected. The plot of the WBC, RBC, hemoglobin, hematocrit and platelet concentrations from approximately 74.4 to $0{\times}10^3/{\mu}L$ and $80.4-0{\times}10^3/{\mu}L$, $5.6-0{\times}10^6/{\mu}L$ and $6.1-0{\times}1106/{\mu}L$, 18.3-0 g/dL and 19.0-0 g/dL, 54.1-0% and 56.8-0% and 642.0 to $0.03{\times}10^3{\mu}L$ and $754.0-0{\times}10^3/{\mu}L$ on the ADVIA 2120 C Versus and A and B typical of an acceptable linear study as shown in Fig. 1-5. The grand mean of R2, intercept and slope is 0.99898, 0.99459 and 1.54626.

  • PDF

A Study on the Fabrication of 1W Power Amplifier for IMT2000 Repeater Using Nonlinear Analysis (비선형 해석법을 이용한 IMT2000 중계기용 1W 전력증폭기 제작 연구)

  • 전광일
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.2
    • /
    • pp.83-90
    • /
    • 2000
  • A simple low-cost and small size 1.88-198 GHz Band RF power amplifier module is developed for IMT2000 repeater. The power amplifier consists of two stage amplifiers that the first stage amplifier is drive amplifier using discrete type P-HEMT (ATF-34143, 800 micron gate width, Agilent Technologies) and the second is power amplifier with 300Bm 1dB gain compression point using GaAs FET(EFA240D-SOT89, 2400 micron gate width, Excelics Semiconductor). this power amplifier module feature a 29.5dBm 1dB gain compression point, 29.5dB gain, 42dBm 3rd order intercept point(OIP3) and -10dB/-l2dB input/output return loss over the 1880-1980 MHz. This PA module is fully integrated using MIC technology into a small size and design by full nonlinear design technologies. The dimensions of this PA module are 42(L) $\times$ 34(W) mm.

  • PDF

OXIDES OF NITROGEN SPECIES MEASUREMENTS AND ANALYSIS IN THE CENTRAL PIEDMONT OF NORTH CAROLINA, U.S.A.

  • Kim, Deug-Soo;Viney P. Aneja
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.E
    • /
    • pp.311-324
    • /
    • 1994
  • The quantitative knowledge of N $O_{\gamma}$ (=N $O_{x}$ +HN $O_3$+/PAN+N $O_3$$N_2$ $O_{5}$ +HN $O_2$+N $O_3$$^{-10}$ +organic nitrates+......)distribution is essential in tropospheric chemistry, especially, especially that related to understanding the processes leading to ozone production. Ambient concentrations of NO, N $O_2$, HN $O_3$ and PAN as well as total N $O_{\gamma}$ were measured during June and early July 1992 at a rural site(Candor, NC), in the central Piedmont region of NC. The measurements of N $O_{\gamma}$ species were made in an effort to provide a comprehensive understanding of nitrogen chemistry and to investigate the total nitrogen budget at the site. N $O_{\gamma}$, N $O_2$, and NO showed diurnal variations with maxima in the morning. The maximum N $O_{\gamma}$ concentration reached was 14.5 ppbv, and the maximum concentrations of NO and N $O_2$ were 5.4 and 7.8 PPbv, respectively. The mean N $O_{\gamma}$ concentration as found to be 2.88$\pm$1.58 ppbv(n=743). The mean concentrations of NO and N $O_2$, were found to be 0.15 $\pm$ 0.29 ppbv(n=785) and 1.31 $\pm$ 0.99 ppbv(n=769). Products of photochemical oxidants, (N <$O_{\gamma}$-N $O_{x}$ ), such as HN $O_3$ and PAN, as well as ozone showed diurnal variation with maxima in the afternoon and minima at night The fractions of individual reactive nitrogen species to total N $O_{\gamma}$ were investigated and contrasted to the results from remote marine site and rural continental sites. N $O_{x}$ was the major species to total N $O_{\gamma}$(45%). NO concentrations appeared to be nearly constant whether the Prevailing winds were from continental areas or from oceanic areas. Linear regression of $O_3$ with (N $O_{\gamma}$- N $O_{x}$ )/N $O_{\gamma}$ (i.e. percent N $O_{x}$ converted to the photochemical products of N $O_{\gamma}$) yielded ( $O_3$) =25.8 〔 N $O_{\gamma}$-N $O_{x}$ 〕/(N $O_{\gamma}$) +27, ( $r^{2}$=0.58). The regression intercept is interpreted as the ozone back ground (intercept=27ppbv) and the slope suggests that 8.6 molecules of ozone are formed per molecule of N $O_{x}$ oxidized products (when the average N $O_{\gamma}$ concentration, about 3 ppbv at the site, is used). The N $O_{x}$ N $O_{\gamma}$ ratio was used as an indicator of the chemical age of airmasses and the ratio showed strong positive correlations with HN $O_3$( $r^{2}$=0.58), PAN ( $r^{2}$=0.46) and $O_3$( $r^{2}$=0.62). Larger N $O_{\gamma}$ and N $O_{x}$ N $O_{\gamma}$ ratio were found when winds came from continental sides. It may suggest that synoptic meteorological conditions and transport of N $O_{x}$ are important in the distribution of N $O_{\gamma}$ and its relationship with photochemical oxidants at the site.

  • PDF

Statistical notes for clinical researchers: simple linear regression 2 - evaluation of regression line

  • Kim, Hae-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.3
    • /
    • pp.34.1-34.5
    • /
    • 2018
  • In the previous section, we established a simple linear regression line by finding the slope and intercept using the least square method as: ${\hat{Y}}=30.79+0.71X$. Finding the regression line was a mathematical procedure. After that we need to evaluate the usefulness or effectiveness of the regression line, whether the regression model helps explain the variability of the dependent variable. Also, statistical inference of the regression line is required to make a conclusion at the population level, because practically, we work with a sample, which is a small part of population. Basic assumption of sampling method is simple random sampling.