• 제목/요약/키워드: X-Ray image

검색결과 1,268건 처리시간 0.029초

열교환기 브레이징 결함의 유형 분류 및 형상 디스플레이 (Type Classification and Shape Display of Brazing Defect in Heat Exchanger)

  • 김진영
    • 제어로봇시스템학회논문지
    • /
    • 제19권2호
    • /
    • pp.171-176
    • /
    • 2013
  • X-ray cross-sectional image-based inspection technique is one of the most useful methods to inspect the brazing joints of heat exchanger. Through X-ray cross-sectional image acquisition, image processing, and defect inspection, the defects of brazing joints can be detected. This paper presents a method to judge the type of detected defects automatically, and to display them three-dimensionally. The defect type is classified as unconnected defect, void, and so on, based on location, size, and shape information of defect. Three-dimensional display which is realized using OpenGL (Open Graphics Library) will be helpful to understand the overall situation including location, size, shape of the defects in a test object.

조명-투과 영상모델을 이용한 방사선 영상 개선에 관한 연구 (The Model of Illumination-Transillumination for Image Enhancement of Xray Images)

  • 유광열;이상민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권1호
    • /
    • pp.67-73
    • /
    • 2001
  • In digital image processing, the homomorphic filtering approach is derived from an illumination-reflectance model of the image. It can also be used with an illumination-transillumnation model of X-ray film. Several X-ray images were applied to enhancement with histogram equalization and homomorphic filter based on an illumination-transillumination model. The homomorphic filter has proven theoretical claim of image density range compression and balanced contrast enhancement, and also was found a valuable tool to process analog X-ray images to digital images.

  • PDF

An Optimal Method to Improve the Visual Quality of Medical Images

  • Shin, Choong-ho;Jung, Chai-yeoung
    • 통합자연과학논문집
    • /
    • 제8권2호
    • /
    • pp.141-144
    • /
    • 2015
  • As the visual quality of X-ray images is a critical reference for the accuracy of the clinical diagnosis, the methods to improve the quality of X-ray images have been investigated. Among many existing methods, using frequency domain filter is a very powerful method to improve the visual quality of images. In this paper, the inherent noises of the input images are suppressed by adding the Laplacian image to the subjected image. The medical X-ray images using the optimal high pass filter has shown improved edges. Further, the optimal high frequency emphasis filter has shown the improved contrast of flat areas by using the result image from the optimal high pass filter. Also the resulting images of the global contrast have improved by the histogram equalization. As a result, the proposed methods have shown enhanced contrast and edges of the images with noise canceling effect.

Spiral CT의 고속 영상재구성 알고리즘에 관한 연구 (A Study on the Fast Image Reconstruction Algorithm for Spiral CT)

  • 허창원;진승오;이재덕;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3207-3209
    • /
    • 2000
  • X-ray CT(Computed Tomography) has been a good modality for non-invasive diagnosis and recently, Conventional CT has been replaced rapidly with Spiral CT in recent. In X-ray CT, spiral scanning has various advantages such as better image quality, reduced scan time (in a single breath-hold), a lower x-ray dose. But, it requires very fast and high performance image processing system to reconstruct slice images from spiral scanning. This paper describes the fast image reconstruction techniques with filtered back projection from the viewpoints of fast algorithm as well as hardware implementation for real-time imaging.

  • PDF

Computed Radiography의 영상특성에 관한 연구 (Study of Image Properties for Computed Radiography)

  • 류기현;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

X-ray CT 스캔을 이용한 사질토 간극비 측정 (Estimation of Void Ratio of Sandy Soil Using X-ray CT Scan)

  • 김광염;신휴성;허성준;임성빈;권영철;김홍택
    • 한국지반공학회논문집
    • /
    • 제27권1호
    • /
    • pp.87-97
    • /
    • 2011
  • 본 연구에서는 산업 전분야에 걸쳐 다양하게 활용되고 있는 X-ray CT의 지반분야 적용을 위해 X-ray CT를 이용한 사질토의 간극비 측정에 관한 연구를 수행하였다. 이를 위해 고분해능 X-ray CT 시스템의 적용에 문제가 되는 빔하드닝(Beam hardening) 및 동심원상 화상결함(Ring artifact) 등에 대한 문제점 지적 및 해결방안을 제시하였다. 또한 X-ray CT를 이용한 간극비 산정을 위한 알고리즘 및 프로그램을 개발하였으며, 이를 이용하여 주문진 표준사의 간극비를 측정하여 신뢰성을 검토하였다.

PCM 클러스터링을 이용한 X-Ray 영상에서 장폐색 추출 (Extraction of Intestinal Obstruction in X-Ray Images Using PCM)

  • 김광백;우영운
    • 한국정보통신학회논문지
    • /
    • 제24권12호
    • /
    • pp.1618-1624
    • /
    • 2020
  • X-ray를 기반으로 하는 장 폐색 진단 방법은 검사자의 주관적인 요소가 포함되기 때문에 객관적 진단에 영향을 미칠 수 있다. 따라서 본 논문에서는 허프 변환과 PCM 클러스터링 기법을 적용하여 장폐색 영역을 추출하는 방법을 제안한다. 제안된 방법은 X-ray 장폐색 영상에서 ROI 영역을 추출한 후, 허프 변환 기법을 이용하여 ROI 영역에서 직선을 검출하고, 검출된 직선을 이용하여 공기 액체층의 형태학적 특징을 이용하여 대장 폐색을 추출한다. 그리고 추출된 ROI 영역을 PCM 클러스터링을 적용하여 ROI 영역을 양자화 한다. 양자화된 ROI 영역 중에서 대장 폐색의 특징이 포함된 클러스터의 그룹을 선정하고, 선정된 클러스터의 그룹에서 객체를 탐색하여 소장 장폐색 영역을 추출한다. 장폐색 환자의 X-ray 영상 30개를 대상으로 PCM 클러스터링을 적용한 결과, PCM의 초기 클러스터의 수를 4개로 설정한 경우가 장폐색 검출 성능이 우수하였고 TPR은 81.47%로 나타났다.

X-ray 코곁굴 검사에서 위턱굴 진단을 위한 비극-두정방향 촬영법 개발 (Development of Acanthial Parieto Projection for Maxillary Diagnosis in X-ray Paranasal Sinuses)

  • 안병주;김용완;김인수
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.327-333
    • /
    • 2023
  • 본 연구는 X-Ray 단순 코곁굴 검사에서 위턱뼈와 위턱굴의 진단하고자 바로누운자세에서 부비동 비극-두정방향은 검사법 연구하였다. Skull Rando Phantom을 이용하여 자세와 엑스선관 각도를 변경하여 검사 후 영상의학과에서 10년 이상 근무한 방사선사 5명에게 주관적평가(ROC)를 의뢰한 결과 엑스선관을 머리쪽 또는 다리쪽을 향하여 5° 씩 기울려 검사 시 19점으로 높은 평가를 맞았다. 평가한 점수를 SPSS Ver. 3.0을 통해 유의성을 검증하였으며 Cronbach 값이 0.712로 유의하게 나타났다. 또한 위턱굴과 위턱뼈 영상의 관심영역(ROI)을 설정하여 SNR를 산출한 결과 엑스선관 머리쪽 또는 다리쪽 5° 씩 기울려 검사 시 6.449로 가장 높게 나타났다. 본 연구에서 X-Ray 단순검사의 코곁굴 검사에서 비극-두정방향(acanthi oparietal projection: Revesse Waters) 검사 시 엑스선관을 머리쪽 또는 다리쪽을 향하여 5° 씩 기울려 검사할 경우 선예한 영상을 얻을 수 있을 것으로 사료된다.

X-ray 영상을 이용한 척추측만증 정도 검출 알고리즘 개발 (Development of Level Detecting Algorithm for Scoliosis using X-ray Image)

  • 박은정;정주영;이기영;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권4호
    • /
    • pp.242-249
    • /
    • 2011
  • 본 연구에서는 척추측만증의 정도를 자동으로 검출할 수 있는 알고리즘을 개발하였다. 개발한 시스템은 X-ray 영상 원본을 사용하였다. 척추 만곡 정도에 대한 수식은 S<0 이고, L>0 인 성립 조건을 갖는 $Y=SX^2+L$의 함수식이다. X축의 길이는 변경이 가능하고 모든 척추선 함수 그래프에서 동일하게 적용되었으며, 기울기 $S=-L/92^2$이다. 척추측만증 정도에 대한 미분 그래프의 수식은 Y'=2SX임을 알 수 있었고, 추출된 척추선에 대한 분류와 척추측만증 정도에 대한 분류가 가능한 알고리즘으로 판단된다.

포톤 계수 방식의 $32{\times}32$ 픽셀 어레이를 갖는 디지털 CMOS X-ray 이미지 센서 설계 (A Design of Digital CMOS X-ray Image Sensor with $32{\times}32$ Pixel Array Using Photon Counting Type)

  • 성관영;김태호;황윤금;전성채;진승오;허영;하판봉;박무훈;김영희
    • 한국정보통신학회논문지
    • /
    • 제12권7호
    • /
    • pp.1235-1242
    • /
    • 2008
  • 본 논문에서는 $0.18{\mu}m$ triple-well CMOS 공정을 사용하여 포톤계수 방식의 $32{\times}32$ 픽셀 어레이를 갖는 CMOS ray 영상센서를 설계하였다. 설계된 영상센서의 카픽셀은 $100{\times}100\;{\mu}m2$ 면적을 가지고 있고 약 400개의 트랜지스터로 구성되어 있으며, 범프 본딩을 통해 ray 검출기와 CSA(Charge Sensitive Amplifier)의 연결을 위한 $50{\times}50{\mu}m2$의 오픈패드를 가지고 있다. 각각의 싱글픽셀 CSA에서 전압 바이어스 회로를 사용한 folded cascode CMOS OP amp 대신 레이아웃 면적을 줄이기 위하여 self biased folded cascode CMOS OP amp를 이용하였으며, 계수 모드 진입 전후에 CLK에서 발생 할 수 있는 short pulse를 제거하는 15bit LFSR 계수기 (Linear Feedback Shift Register Counter) 클럭 발생회로를 제안하였으며, 읽기 모드에서 CMOS X-ray 영상센서의 최대 전류를 줄이기 위하여 열 어드레스 디코더를 이용하여 한 열씩 읽도록 설계하였다.