• Title/Summary/Keyword: X-Ray diffraction measurement

Search Result 519, Processing Time 0.026 seconds

A Study on the Measurement of Residual Stress in Rolled Steel for Automobile using X-ray Diffraction (X선 회절을 이용한 자동차 압연강의 잔류응력 측정에 관한 연구)

  • 홍순혁;이동우;조석수;주원식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.150-157
    • /
    • 2002
  • In textured material, diffraction angle $2{\theta}$ usually shows a nonlinear relation against $sin^2{\psi}$ due to elastic anisotropy of crystals. SPHD and SPCD steel is cold-rolled carbon steel for automobile. The characteristics X-ray for stress measurement is Cr $K_{\alpha}\;and\;Mo\;K_{\alpha}$ characteristic X-ray. The $2{\theta}-sin^2{\psi}$ diagram under elastic strain seems to have a linear behavior using regression line of data but has a nonlinear behavior in distribution of data by Cr $K_{\alpha}$ characteristic X-ray. As the plastic strain of specimen increases, the nonlinearity of $2{\theta}$ with respect to $sin^2{\psi}$ increases remarkably. On the other hand, the diffraction angle $2{\theta}$ by Mo $K_{\alpha}$ characteristic X-ray shows a good linearity on $2{\theta}-sin^2{\psi}$ diagram under plastic strain as well as elastic strain. Therefore, this paper presents the measurement of residual stress in cold-rolled carbon steel for automobile using penetration depth of Mo $K_{\alpha1}$ characteristic X-ray and multiplicity factor of crystal diffraction plane.

Comparison of Different Techniques for Measurement of Cold Work in Mild Steel

  • Badgujar, B.P.;Jha, S.K.;Goswami, G.L.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.616-621
    • /
    • 2003
  • There are various Non-Destructive Evaluation (NDE) techniques used for measurement of residual stresses in material, such as magnetic methods, X-ray diffraction, Ultrasonic velocity measurement etc. The capabilities, applications and limitations of these techniques for evaluation of cold work/plastic deformation were studied and compared. Mild steel plates were subjected to different degree of cold deformation and were analyzed by Magneto-mechanical Acoustic Emission (MAE), Barkhausen Noise (BN) and magnetic properties (hysteresis loop parameters analysis). Further, these specimens were analyzed by X-ray diffraction and ultrasonic velocity measurements. The microhardness measurement and microstructure studies of these cold worked plates were also carried out. The results of all these studies and comparison of different techniques are discussed in this paper.

A Study on Residual Stress for Fatigue Fracture Surface in General Purpose Structural Steel using X-ray Diffraction (X-선 회절을 이용한 피로하중을 받는 일반구조용강의 잔류응력에 관한 연구)

  • 조석수;장득열;주원식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.248-261
    • /
    • 1999
  • The fatigue life of mechanical components and structures has been influenced by mechanical, material and environmental conditions. It is important to search out the load type and size for accurate cause of fracture at the damaged surface of material. The fractographic method by x-ray diffraction can utilize residual stress $\sigma$_r and half-value breadth B and find out the types and the mechanical conditions of fracture. This study showed the relationship between fracture mechanical parameters $\Delta$K, $K_{max}$ and X-ray residual stress $\sigma$_r for normalized SS41 steel with homogeneous crystal structure and M.E.F. dual phase steel(martensite encapsulated islands of ferrite). The fatigue crack propagation tests were carried out under stress ratios 0.1 and 0.5. The x-ray diffraction technique according to crack propatation direction was applied to fatigue fractured surface. Residual stress $\sigma$_r was independent on stress ratios by arrangement of $\Delta$K. The equation of $\sigma$_r$\Delta$K was established by the experimental data. Therefore, fracture mechanical parameters can be estimated can be estimated by the measurement of X-ray parameters.

  • PDF

Evaluation of Thermal Degradation of 2.25Cr-1Mo Steel Using Ultrasonic Nonlinear Effect and X-ray Diffraction Method (초음파 비선형 음향 효과 및 X-선 회절법을 이용한 2.25Cr-1Mo 강의 열화 손상 평가)

  • Kim, Duk-Hee;Park, Un-Su;Park, Ik-Keun;Byeon, Jai-Won;Kwun, Sook-In
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.71-79
    • /
    • 2002
  • It was attempted to evaluate the degree of degradation of thermally aged 2.25-1Mo steek by ultrasonic monlinear parameter(UNP) measurement and X-ray diffraction analysis of extracted carbide. Artificial aging was performed to simulate the microstructural degradation in 2.25Cr-1Mo steel arising from long time exposure at $540{\circ}C$. Microstructural analysis (number of carbides per unit area) and measurements of mechanical properties(Vickers hardness, DBTT) and degradation evaluation parameters(UNP and intensity ration of X-ray diffraction peak of electrolytically extracted carbide) were performed. Both of UNP and intensity ratio of X-ray diffraction peak for M6C carbide to that of M23C6 carbide(IR) increased abruptly in the initial 1000 hour of aging and then changed little. UNP and IR were proposed as potential parameters to evaluate the degree of aging degradation of 2.25Cr-1Mo steel.

Phase Analysis of Immiscible V-Cu MA Powders by Neutron and X-ray Diffraction (비고용 V-Cu계 MA합금의 중성자 및 X선 회절에 의한 상분석)

  • Lee Chung-Hyo;Cho Jae-Moon;Lee Sang-Jin;Kim Ji-Soon
    • Korean Journal of Materials Research
    • /
    • v.14 no.5
    • /
    • pp.348-352
    • /
    • 2004
  • The mechanical alloying (MA) effect in immiscible V-Cu system with positive heat of mixing was studied by not only the neutron and X-ray diffraction but also the analysis of DSC spectra. The total energy, ΔHt accumulated during MA for the mixture of $V_{50}$ $Cu_{50}$ / powders increased with milling time and approached the saturation value of 14 kJ/mol after 120 h of milling. It can be seen that the free energy difference between the amorphous phase and the pure V and Cu powders with an atomic ratio 5:5 is estimated to be 11 kJ/mol by Miedema et al. This is thermodynamically taken as one of the evidences for the amorphization. The structural changes of V-Cu MA powders were characterized by the X-ray diffraction and neutron diffraction. We take a full advantage of a negligibly small scattering length of the V atom in the neutron diffraction measurement. The neutron diffraction data definitely indicate that the amorphization proceeds gradually but incompletely even after 120 h of MA and bcc-Cu Bragg peaks appears after 60 h of MA.

Residual Stress Measurement on Welded Specimen by Neutron Diffraction (중성자 회절을 이용한 용접부위의 잔류응력 측정)

  • 박만진;장동영;최희동
    • Journal of Welding and Joining
    • /
    • v.20 no.2
    • /
    • pp.50-58
    • /
    • 2002
  • Residual stress is generated in the structures as a result of irregular elastic-plastic deformation during fabrication processes such as welding, heat treatment, and mechanical processing. There are several factors attributed to the origin of residual stresses, tensile or compressive. The stresses can be determined by destructive ways or nondestructive ways using X-ray or neutron diffraction. Although X-ray diffraction is a well established technique, it is practically limited to near-surface stresses. Neutrons penetrate easily into most materials and neutron diffraction permits non-destructive evaluation of lattice strain within the bulk of large specimens because the radiation is more deeply penetrating for metallic engineering components. This paper presented application of neutron diffraction technique to the residual stress measurement using 20 mm thick welded stainless steel plate($100{\times}100 \textrm{mm}^2$)

Effect of Thermal Cycle on Strength of Ceramic and Metal Joint (세라믹/금속접합재의 강도에 미치는 열사이클 영향)

  • 박영철;오세욱;김광영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1664-1673
    • /
    • 1994
  • As a fundamental study on effects of thermal-cycles on residual stress of ceramics/metal joints, residual stresses in $Si_3N_4$/SUS304 joint specimens were measured before and single thermal-cycle by X-ray diffraction method and finite element method(FEM). The residual stress was found to increase after single thermal-cycle, which was agreeable with the results of residual stress measurement by X-ray diffraction method and residual stress analysis by finite element method. After the residual stress measurement, 4-point bending tests were performed. The relationship between the bending strength, the thermal-cycle temperature and hold time was examined. The bending strength was found to decrease with the increase of residual stress in linear relation.

Modification of conventional X-ray diffractometer for the measurement of phase distribution in a narrow region

  • Park, Yang-Soon;Han, Sun-Ho;Kim, Jong-Goo;Jee, Kwang-Yong;Kim, Won-Ho
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.407-414
    • /
    • 2006
  • An X-ray diffractometer for spatially resolved X-ray diffraction measurements was developed to identify phase in the narrow (micron-scaled) region of high burn-up fuels and some nuclear materials. The micro-XRD was composed of an X-ray microbeam alignment system and a sample micro translation system instead of a normal slit and a fixed sample stage in a commercial XRD. The X-ray microbeam alignment system was fabricated with a microbeam concentrator having two Ni deposited mirrors, a vertical positioner, and a tilt table for the generation of a concentrated microbeam. The sample micro translation system was made with a sample holder and a horizontal translator, allowing movement of a specimen at $5{\mu}m$ steps. The angular intensity profile of the microbeam generated through a concentrator was symmetric and not distorted. The size of the microbeam was $4,000{\times}20{\mu}m$ and the spatial resolution of the beam was $47{\mu}m$ at the sample position. When the diffraction peaks were measured for a $UO_2$ pellet specimen by this system, the reproducibility ($2{\Theta}={\pm}0.01^{\circ}$) of the peaks was as good as a conventional X-ray diffractometer. For the cross section of oxidized titanium metal, not only $TiO_2$ in an outer layer but also TiO near an oxide-metal interface was observed.

Crystal Structure of $KD_2PO_4$: Neutron and X-ray Diffraction Studies ($KD_2PO_4$의 결정구조: 중성자와 X-선 회절에 의한 연구)

  • 김신애;심해섭;이창희
    • Korean Journal of Crystallography
    • /
    • v.11 no.3
    • /
    • pp.162-166
    • /
    • 2000
  • KD₂PO₄ single crystals were grown from D₂O with reagent KH₂PO₄ and the crystal structure was determined by X-ray and neutron diffraction methods. The crystals are tetragonal at room temperature, I42d, with lattice parameters of a=7.4633(7), c=6.9785(5) Å and Z=4. Intensity data were collected on an Enraf-nonius CAD4 diffractometer with a graphite monochromated MoK/sub α/ radiation (λ=0.7107Å) and on the neutron four circle single crystal diffractometer with Ge(331) monochromated neutron beam (λ=0.997Å). The structure was refined by full-matrix least-square to final R and wR values of 0.030 and 0.072, respectively, for 204 observed reflections with I>2σ(I) by X-ray diffraction and to final R=0.041 and wR=0.096 for 144 observed relfecdtions by neutron diffraction. The O…O distance of 2.516(4)Å obtained by X-ray diffraction is the same as that of 2.515(4)Å by neutron diffraction. On the other hand, the O-D/H distance of 0.84(4)Å by X-ray diffraction is considerably shorter than 1.029(7) Åby neutron diffraction. Hydrogen and deuterium can be readily distinguished by neutrons. In this crystal 66% of H-positions were substituted by D and the rest 34% occupied by H. The phase transition temperature of DKDP obtained with deuteration levels is f193K. This value agrees fairly well with the result of DSC measurement. The nuclear density distribution by neutron diffraction provides an observation of the disordered state of D/H in KD₂PO₄ at room temperature.

  • PDF

Real-time X-ray Scattering as a Nanostructure Probe for Organic Photovoltaic Thin Films

  • Lee, Hyeon-Hwi;Kim, Hyo-Jeong;Kim, Jang-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.181-181
    • /
    • 2013
  • Recently, nanostructure and the molecular orientation of organic thin films have been largely paid attention due to its importance in organic electronics such as organic thin film transistors (OTFTs), organic light emitting diodes (OLEDs), and organic photovoltaics (OPVs). Among various methods, the diffraction and scattering techniques based on synchrotron x-rays have shown powerful results in organic thin film systems. In this work, we introduce the in-situ annealing system installed at PLS-II (Pohang Light Source II) for organic thin films by simultaneously conducting various x-ray scattering measurements of x-ray reflectivity, conventional x-ray scattering, grazing incidence wide angle x-ray scattering (GI-WAXS) and so on. Using the in-situ measurement, we could obtain real time variation of nanostructure as well as molecular orientation during thermal annealing in metal-phthalocyanine thin films. The variation of surface and interface also could be simultaneously investigated by the x-ray reflectivity measurement.

  • PDF