• Title/Summary/Keyword: X-Ray Projection

검색결과 143건 처리시간 0.031초

6 DOF Pose Estimation of Polyhedral Objects Based on Geometric Features in X-ray Images

  • Kim, Jae-Wan;Roh, Young-Jun;Cho, Hyung-S.;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.63.4-63
    • /
    • 2001
  • An x-ray vision can be a unique method to monitor and analyze the motion of mechanical parts in real time which are invisible from outside. Our problem is to identify the pose, i.e. the position and orientation of an object from x-ray projection images. It is assumed here that the x-ray imaging conditions that include the relative coordinates of the x-ray source and the image plane are predetermined and the object geometry is known. In this situation, an x-ray image of an object at a given pose can be estimated computationally by using a priori known x-ray projection image model. It is based on the assumption that a pose of an object can be determined uniquely to a given x-ray projection image. Thus, once we have the numerical model of x-ray imaging process, x-ray image of the known object at any pose could be estimated ...

  • PDF

Rotating-Gantry-Based X-Ray Micro-Tomography System with the Sliding Mechanism Capable of Zoom-In Imaging

  • Cho, Min-Hyoung;Lee, Dong-Hun;Han, Byung-Hee;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권2호
    • /
    • pp.107-113
    • /
    • 2008
  • We introduce a rotating-gantry-based x-ray micro-tomography system to be used for small animal imaging studies. It has the zoom-in imaging capability for high resolution imaging of a local region inside the animal subject without any contrast anomalies arising from truncation of the projection data. With the sliding mechanism mounted on the rotating gantry holding the x-ray source and the x-ray detector, we can control the magnification ratio of the x-ray projection data. By combining the projection data from the large field of view (FOV) scan of the whole animal subject and the projection data from the small FOV scan of the region of interest, we can obtain artifact-free zoomed-in images of the region of interest. For the acquisition of x-ray projection data, we use a $1248{\times}1248$ flat-panel x-ray detector with the pixel pitch of 100 mm. It has been experimentally found that the developed system has the spatial resolution of up to 121p/mm when the highest magnification ratio of 5:1 is applied to the zoom-in imaging. We present some in vivo rat femur images to demonstrate utility of the developed system for small animal imaging.

X-ray 코곁굴 검사에서 위턱굴 진단을 위한 비극-두정방향 촬영법 개발 (Development of Acanthial Parieto Projection for Maxillary Diagnosis in X-ray Paranasal Sinuses)

  • 안병주;김용완;김인수
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.327-333
    • /
    • 2023
  • 본 연구는 X-Ray 단순 코곁굴 검사에서 위턱뼈와 위턱굴의 진단하고자 바로누운자세에서 부비동 비극-두정방향은 검사법 연구하였다. Skull Rando Phantom을 이용하여 자세와 엑스선관 각도를 변경하여 검사 후 영상의학과에서 10년 이상 근무한 방사선사 5명에게 주관적평가(ROC)를 의뢰한 결과 엑스선관을 머리쪽 또는 다리쪽을 향하여 5° 씩 기울려 검사 시 19점으로 높은 평가를 맞았다. 평가한 점수를 SPSS Ver. 3.0을 통해 유의성을 검증하였으며 Cronbach 값이 0.712로 유의하게 나타났다. 또한 위턱굴과 위턱뼈 영상의 관심영역(ROI)을 설정하여 SNR를 산출한 결과 엑스선관 머리쪽 또는 다리쪽 5° 씩 기울려 검사 시 6.449로 가장 높게 나타났다. 본 연구에서 X-Ray 단순검사의 코곁굴 검사에서 비극-두정방향(acanthi oparietal projection: Revesse Waters) 검사 시 엑스선관을 머리쪽 또는 다리쪽을 향하여 5° 씩 기울려 검사할 경우 선예한 영상을 얻을 수 있을 것으로 사료된다.

X-ray 등뼈의 사위 촬영에서 돌기사이관절의 진단을 위한 촬영법 연구 (A Study on Projection for Apophyseal Joints Diagnosis in X-ray Thoracic Bone Oblique Projection)

  • 이준행
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.351-357
    • /
    • 2023
  • 본 연구는 엑스선 등뼈 사위촬영에서 등뼈의 돌기사이관절 및 고리뿌리의 선예한 영상을 얻어 진단하고자 대학병원 영상의학과 방사선사 5명에게 주관적 평가 ROC 평가를 받아다. 주관적 평가에서 등뼈 엑스선 촬영에서 팬톰을 바로누운자세에서 LAO로 70° 기울게 하고 엑스선관을 머리 쪽 향하여 5°에서 20점을 받아 가장 높은 점수를 얻었다. 또한, 팬톰을 엎드려서 RAO로 60° 기울게 하고 엑스선관을 머리쪽을 향하여 8°에서 19점으로 가장 높은 점수를 받았다. 객관적 평가를 위하여 신호대 잡음비(SNR)를 산출했다. 영상신호 평균값(Mean값)과 표준편차(SD값)를 획득하기 위하여 1,564 mm2에서 ROI를 설정하였다. 객관적 평가는 등뼈 사위촬영, 바로누운자세는 팬톰을 LPO 70° 기울게 한 자세는 엑스선관을 머리쪽을 향하여 5°에서 신호대 잡음비가 6.154로 가장 높았으며, 또한 팬톰을 엎드려서 RAO 60° 와 엑스선관을 머리쪽을 향하여 8°에서 5,645으로 가장 높았다.

이중 프로젝션 필터를 이용한 흉부 X-선 영상의 복원 (Restoration of Chest X-ray Image Using Dual Projection Filter)

  • 이태수;민병구
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권1호
    • /
    • pp.25-32
    • /
    • 1992
  • A new restoration method of chest X -ray image (dual project filter) was proposed to improve SNR(signal to noise ratio) characteristics. In this method, a priori Information of system and anatomical structure and statistics of projected object are used in the design of filter. Dual projection filter varies its parameters, adapting to the local regions of chest(lung region, mediasternum, subdiaphragm) and the structure of chest (bone, tissue, blood vessel, bronchia). The performance of Dual Projection Filter was 0.1-0.2dB better than Dual Sensor Wiener Filter, which was used for initial estimate of Dual Porjection Filter.

  • PDF

Metal Area Segmentation in X-ray CT Images Using the RNA (Relevant Neighbor Ar ea) Principle

  • Kim, Youngshin;Kwon, Hyukjoon;Kim, Joongkyu;Yi, Juneho
    • 한국멀티미디어학회논문지
    • /
    • 제15권12호
    • /
    • pp.1442-1448
    • /
    • 2012
  • The problem of Metal Area Segmentation (MAS) in X-ray CT images is a very hard task because of metal artifacts. This research features a practical yet effective method for MAS in X-ray CT images that exploits both projection image and reconstructed image spaces. We employ the Relevant Neighbor Area (RNA) idea [1] originally developed for projection image inpainting in order to create a novel feature in the projection image space that distinctively represents metal and near-metal pixels with opposite signs. In the reconstructed result of the feature image, application of a simple thresholding technique provides accurate segmentation of metal areas due to nice separation of near-metal areas from metal areas in its histogram.

X-ray CT의 실시간 영상재구성을 위한 병렬처리 구조에 관한 연구 (A Study on the Parallel Processing Architecture for the Real Time Image Reconstruction of X-ray CT)

  • 진승오;허창원;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3153-3155
    • /
    • 1999
  • 최근 수년간 의료영상분야는 국내외적으로 급격한 발전을 거듭하고 있다. 특히 자기공명영상장치 (Magnetic Resonance Imaging), X-ray CT(Computed Tomography)와 단층촬영장치는 인체내부를 비침습적(non-invasive)으로 영상화함으로써 해부학적인 질병진단에 많은 장점을 가지고 있다. 이와같은 단층영상 재구성에는 역매트릭스법(matrix inversion). 반복재구성법(interative method), 역투영 법(back-projection), 2차원 Fourier 변환법(2D FFT), 중첩재구성법(Filtered back-projection) 등의 다양한 알고리즘을 사용하고 있다. 본 연구에서는 X-ray CT에서의 단층영상재구성 기법 중 널리 사용되고 있는 Filtered Back Projection 기법의 연산순서도와 연산량을 분석하고 이를 시뮬레이션을 통하여 확인하고 실시간 영상재구성을 위하여 범용 Digital Signal Processor의 병렬처리시스템 구성에 기반된 최적 Architecture를 선정하고자 한다.

  • PDF

경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석 (Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image)

  • 황중원;황재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

인체 골격의 X-ray 투사 이미지를 활용한 패션디자인 (Human Skeletal X-ray Projection Images Applied Fashion Design)

  • 박정인;이연희
    • 한국의상디자인학회지
    • /
    • 제17권3호
    • /
    • pp.13-27
    • /
    • 2015
  • The purpose of this study is to understand the general process from textile design till fashion design and to understand the relation between the body structure by using the x-ray technique. The research method was to see background of the anatomic feature and human skeletal X-ray projection through historical aspect of publications, the Internet, and paper. In terms of production, in order to present a design that takes into account the unique silhouette of the human body without distorting the shape of the human skeleton, X-ray images that were reconstituted using a computer graphic tool (Photoshop CS) were reproduced into the fabric as intense images through the digital Textile Printing technique that is capable of expressing fine and delicate details, and applied into the design. An original design was developed that emphasized the impression of the human body being projected and the shape of the human skeleton realistically expressed in terms of silhouette and detail. The results are as follows: First, Body has a anatomic formative characteristic and its formativeness becomes as a great motive for the artistic expression and thereby it becomes more unique and available for new design expression. Second, Using the 'body frame' as the motive of the research, there's mainly tried to make an unique expression. Third, according to reconstructing human skeletal X-ray projection by using Adobe Photoshop CS2, it can be expressed strong and unique design. Forth, DTP which is being used as an essential technique, expresses the body frame realistically and being used the special type of functional product and silk. Likewise by discovering the diverse formativeness of our body frame and reflecting the sense of humanity into the pieces there's been able to make and develop an unique fashion design. I sincerely hope there is a hug progress in this research in this area.

  • PDF

두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가 (Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.153-159
    • /
    • 2024
  • 일반 X-선 촬영에서 경험이 없는 비숙련자의 경우, 검사 실패의 경험을 통해 숙련되는 과정을 겪는다. 이것은 불필요한 의료 피폭 가중의 문제를 유발한다. 본 연구에서는 배치 전 비숙련 방사선사가 임상 숙련도를 높일 수 있는 방안으로, 시각적, 공간적 보조 장치를 이용한 두개골 측방향 촬영 실습을 통해, 촬영 보조장치 사용에 따른 정확도와 유용성을 평가하였다. 육안적 관찰과 학습에 의존해서 촬영한 경우 영상 왜곡을 나타내는 회전 이격도 7.85 ± 1.45 mm, 기울임 이격도 4.84 ± 0.5 mm였다. 시각적 보조 장치를 이용해서 실습한 경우 회전 이격도 4.4 ± 0.76 mm, 기울임 이격도 3.01 ± 0.87mm였다. 공간적 보정 기구를 이용해서 실습한 경우 회전과 기울임 이격도는 5.2 ± 0.69 mm, 3.33 ± 0.61 mm로 나타났다. 배치 후 작업 환경과 동일한 조건에서 경험적 촬영 실습에 의한 영상 왜곡은 5.4% 감소하였으나, 기울임에 의한 영상 왜곡은 1.2% 증가하였다. 시각적 보조 장치를 이용해서 실습한 경우, 경험적 촬영 실습보다 회전이격도 40.1% 기울임 이격도 30.7% 감소하였다. 공간적 보정 기구를 사용할 경우, 기존의 경험적 실습 방식보다 회전 이격도 41.7%, 기울임 이격도 23.7% 감소하였다. 따라서 비숙련 방사선사의 배치 전 시각적, 공간적 촬영 보조 기구를 이용한 실습은 배치 후 검사 정확도 향상과 재촬영률 감소에 도움을 줄 수 있을 것으로 사료된다.