• Title/Summary/Keyword: X-Ray Inspection System

Search Result 77, Processing Time 0.03 seconds

Mechanical Properties and Reaction Products of Activated Slag System Depending on Gypsum Presence and Calcium Carbonate Addition (석고 존재 및 탄산칼슘 첨가에 따른 활성 슬래그의 역학적 성능 및 반응생성물)

  • Jeong, Yeonung;Lim, Gwi Hwan;Park, Su Hyeon;Kim, Joo Hyung;Kim, Tae-Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.55-63
    • /
    • 2020
  • This study investigates the mechanical properties and reaction products of activated slag pastes depending on gypsum presence and calcium carbonate addition in terms of compressive strength tests and synchrotron X-ray diffraction. The chemicals of CaO and NaOH are used as activators with different two dosages. The reaction of CaO-activated slag without gypsum just accelerated by addition of calcium carbonate at early ages, but no improvement was observed at later ages. On the other hand, the mechanical properties of CaO-activated slag pastes with gypsum were improved with calcium carbonate, enhancing the stability of ettringite. The variation of mechanical properties of NaOH-activated slag pastes was negligible depending on calcium carbonate addition in case of no gypsum. The addition of calcium carbonate into NaOH-activated slag pastes with gypsum deteriorated its mechanical properties due to the ion competition between CO32- ions and SO32- ions, decreasing crystallinity of reaction products.

Study on Optimal Welding Condition for Shipbuilding Steel Materials (조선강재의 최적 용접조건에 관한 연구)

  • Kim, Ok-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.128-133
    • /
    • 2011
  • In this study, the steel material for shipbuilding(LR-A class) was used, and FCAW was taken advantage of 3G attitude and they are welded by different welding ways. As a result of analyzing wave with welding monitoring system, the stable values are obtained which are the first floor(electronic current 164~182 A, voltage 24 V), the second floor(electronic current 174~190 A, voltage 22~25 V), the third floor(electronic current 158~188 A, voltage 22~25 V), and fourth floor(electronic current 172~184 A, voltage 22~25 V), at this time, the stable wave standard deviation and changing coefficient could be obtained. When the welding testing through nondestructive inspection was analyzed know defect of welding, there was no defect of welding in A, D, E, but some porosities in B, and slag conclusion near the surface in C, because the length of arc was not accurate, and the electronic current and voltage was not stable. After observing the change of heat affect zone through micro testing, each organization of floor formed as Grain Refinement, so welding part was fine, the distance of heat affect zone is getting wider up to change the values of the electronic current and voltage. As a result of degree of hardness testing, the hardness orders were the heat affect zone(HAZ), Welding Zone(WZ), and Base Metal(BM). When the distribution of degree of hardness is observed. B is the highest degree of hardness The reason why heat effect zone is higher than welding zone and base metal, welding zone is boiled over melting point($1539^{\circ}C$) and it starts to melt after the result of analysis through metal microscope, so we can know that delicate tissue is created at the welding zone. Therefore, in order to get the optimal conditions of the welding, the proper current of the welding and voltage is needed. Furthermore the precise work of welding is required.

Diagnosis of Work-related Musculoskeletal Disease through Moire Image Pattern and Treatment Measure using a Sling System (Moire' 영상무늬를 통한 근골격계질환의 진단과 현가장치를 이용한 치료방안)

  • Lee Sang-Yong;Lee Eun-Kyong;Kwon So-Hee;Jung He-Kyong;Kim Sam-Tae;Chong Myong-Soo;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 2003
  • The Musculoskeletal Disease has been ignored or turned away due to the difficulty of diagnosis and the vagueness of judgement up to now. Contrary to other diseases, there were many cases where the character of the Musculoskeletal Disease wasn't revealed through the objective inspection. And that's because the Musculoskeletal Disease appears for the most part due to muscular defect so it is impossible to diagnose the muscle by X-ray diagnosing the bone and it is also impossible to diagnose the fine damage of the muscle or tendon even by advanced device like MRI. As the nervous blood vessels or acupunctures pass through or are next to the muscle, the tension of the muscle put pressure on these so can become the direct or indirect causes of various kinds of pains or intern diseases. But in spite of that, for lack of proper equipment diagnosing the state of the muscle(Shortened.. Relaxed... or Hardened...) the muscle has been disregarded or neglected intentionally or unintentionally. While many people think themselves to be a muscular expert, if they don't see the shape of the muscle, that is just like blind treatment. But as now the equipment diagnosing the state of the muscle is developed, it seems that this problem can be settled. It was attempted in this study that the muscle or skeleton of the Musculoskeletal disease patients was diagno the treatment order and method were decided by a questionnaire survey and simple inspection, and the Musculoskeletal correction exercise using the muscle management and sling system made them escape from the Musculoskeletal disease, turning their muscle into more flexible and stronger muscle. As a result notwithstanding the limited treatment period '12 times', the improvement rate was as high as 74%, which showed that the muscle management and Musculoskeletal correction exercise had a great effect on the symptom improvement of the patients. If the treatment times had increased, the improvement rate also would have increased more.

  • PDF

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.

Quality Improvement on Upper Gastrointestinal Series (위장조영검사에서 화질 개선 방법)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.395-401
    • /
    • 2016
  • Upper gastrointestinal series is a diagnostic test that X-ray passes through the stomach after administering contrast media such as barium or gastrografin. Upper gastrointestinal series with an advantage of no side effect except temporary constipation or abdominal pain has been widely used to diagnose diseases of the gastrointestinal system. However, image degradation and diagnostic accuracy frequently occurred when improper movement and breath control were carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. The movie of the upper gastrointestinal series was made for improving inspection accuracy and image quality. The examinees encouraged to see the movie for waiting time before doing upper gastrointestinal series. In this study, image quality and diagnostic accuracy was examined for the effect of the movie about upper gastrointestinal series. 60 patients composed of each 10 people from 30s to 80s were selected randomly among both 2,940 examinees in 2014 and 3,076 examinees in 2015. Image quality was evaluated by the full width at half maximum of profile for each image using the Image J. The measurement of the full width at half maximum showed 0.208 mm and 0.133 mm for after and before seeing the movie. Thus it was verified that the movie education could improve the image quality and diagnostic accuracy for upper gastrointestinal series.

Research on Dose Reduction During Computed Tomography Scanning by CARE kV System and Bismuth (전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Jeong, Seong-Pyo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.8
    • /
    • pp.233-242
    • /
    • 2014
  • The purpose of this study is to compare the reduction of the dose radioactivity by CARE kV with that of the Bismuth shielding. First, CT was performed with transparent materials, including a Bismuth shielder which is a well-known material for decreasing the dose of radiation. Moreover, we have estimated and compared the affects of the reduction of dose on eye lens, thyroid, breast and genitals. These steps aim to compare reactions with and without the application of the Rando phantom with PLD as well as with CARE kV or not. As a result, during the Brain angio scan, the dose of CARE kV set inspection test methods showed the least dose. Depending on whether we use CARE kV, which showed the effect of dose reduction by 63%. During the Carotid angio scan, the dose was increased by 13% by how to set CARE kV+Bismuth. During the Cardiac angio scan, which showed the effect of dose reduction by 31% by how to set CARE kV+Bismuth. During the Lower extremity angio scan, the dose was measured least by how to set up the whole Bismuth. Compared with CARE kV set of test methods, which showed the effect of dose reduction by 9%.

Effectiveness Evaluation of the Tube Voltage Measurement by using Additional Filter (부가필터를 이용한 kVp 측정의 실효성 평가)

  • Hwang, Jun-Ho;Lee, Kyung-Ho;Choi, Yoon-Bong;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.355-363
    • /
    • 2015
  • Advancement in the medical field provides an opportunity for the development of medical equipment and also enable accurate diagnosis for the inspection and the treatment of diseases. The aging of equipment due to the frequent operation produce uncertainty in the patient exposure dose, so a quality control was implemented by establishing a safety management system on a regular basis. The x-ray tube voltage (kVp), which is directly involved in the patient exposure dose and the life of the equipment, needs periodic performance for the quality control, but it has a limitation due to the time and the cost. In this study, we proposed a new method for measuring the kVp with ease by using the Y and Cu to solve the problem of the time and cost. We also evaluated the usefulness and the effectiveness of the new method and its accuracy through the kVp measurement. After securing the condition, the amount of the tube current and evaluating the usefulness and effectiveness of kVp measured using Y and Cu. The density range used was at 0.5-1.0, kVp was in the range of ${\pm}10%$, then, we recorded the change in concentration as % of Y and Cu. This experiment showed that when Cu and Y was at 75 kVp, concentration was the same, and when the kVp was changed to 65 ~ 85 %, a gradual increase in concentration to 85 ~ 110 % was noted.