• Title/Summary/Keyword: X-Ray

Search Result 16,598, Processing Time 0.042 seconds

Variations in Morphological and Geochemical Characteristics in Manganese Nodules from the East Siberian Arctic Shelf with Varying Water Depths (동시베리아해 대륙붕에서 산출되는 망가니즈단괴의 수심에 따른 형태학적·지화학적 특성 변화)

  • Hyo-Jin Koo;Hyen-Goo Cho;Sangmi Lee;Gi-Teak Lim;Hyo-Im Kim
    • Economic and Environmental Geology
    • /
    • v.56 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • In this study, we explore the morphological and geochemical characteristics for 440 manganese nodules collected from two different water depths [ARA12B-St52 (150 m, n = 239) and ARA12B-St58i (73 m, n = 201)] on the continental shelf of the East Siberian Sea from the ARA12B expedition in 2021. We also discussed the variations in the characteristics of manganese nodules with varying water depths in the Arctic Sea. The sizes of the nodules are generally greater than 3 cm at both sites. However, there is an obvious difference in the morphology with water depths. For the nodules collected at 150 m, brown-black colored tabular, tube, and ellipsoidal shapes with a rough surface texture are dominant. On the other hand, yellow-brown tabular shapes with a smooth surface texture are common for the nodules collected at 73 m. Furthermore, the slope of trend line between size and weight is significantly different at both sites: particularly, the slopes of nodules at 150 and 73 m are 1.60 and 0.84, respectively. This indicates the difference in the internal structure, porosity, and constituting elements between both nodules. Micro X-ray Flourescence (µ-XRF) results clearly demonstrate that the internal textures and chemical compositions are different with water depths. The nodules at 150 m are composed of a thick Mn-layer and a thin Fe-layer centered on the nucleus, while the nodules at 73 m are alternately grown with thin Mn- and Fe- layers around the nucleus. The average chemical compositions obtained by µ-XRF are 40.6 wt% Mn, 5.2 wt% Fe, and 7.9 Mn/Fe ratio at 150 m, and 10.3 wt% Mn, 19.0 wt% Fe, and 0.6 Mn/Fe ratio at 73 m. The chemical compositions of the nodules at 150 m are similar to those of nodules from the Peru Basin in the Pacific Ocean, while the compositions of the nodules at 73 m are similar to those of nodules from the Cook Islands or the Baltic Sea. The observed morphological and geochemical characteristics of the nodules show a clear difference at the two sites, which indicates that the aqueous conditions and formation processes of the nodules in the Arctic Sea vary with the water depths.

Characteristics of Blood Mixed Cement in Percutaneous Vertebroplasty (경피적 척추 성형술에서 혈액 혼합 시멘트의 특성)

  • Seo, Jin-Hyeok;Woo, Young-Ha;Jeong, Ju-Seon;Kim, Do-Hun;Kim, Ok-Gul;Lee, Sang-Wook;Park, Chan-Ho
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.435-439
    • /
    • 2019
  • Purpose: This study evaluated the efficacy of blood mixed cement for osteoporotic vertebral compression fractures in reducing the complications of percutaneous vertebroplasty using conventional cement. Materials and Methods: This study was performed retrospectively in 80 patients, from January 2016 to January 2017. Porous cement was formed by mixing 2, 4, and 6 ml of blood with 20 g of cement used previously. A tube with a diameter and length of 2.8 mm and 215 mm, respectively, was used and the polymerization temperature, setting time, and optimal passing-time were measured and compared with those using only conventional cement. Radiologically, the results were evaluated and compared. Results: The polymerization temperature was 70.3℃, 55.3℃, 52.7℃, and 45.5℃ in the conventional cement (R), 2 ml (B2), 4 ml (B4), and 6 ml (B6), respectively, and the corresponding setting time decreased from 960 seconds (R) to 558 seconds (B2), 533 seconds (B4), and 500 seconds (B6). The optimal passing-time was 45 seconds (B2), 60 seconds (B4), and 78 seconds (B6) at 73 seconds (R), respectively and as the amount of blood increased, it was similar to the cement passing-time. The radiological results showed that the height restoration rates and the vertebral subsidence rates similar among the groups. Two cases of adjacent vertebral compression fractures in the R group and one in the B2 and B4 groups were encountered, and the leakage rate of the cement was approximately two times higher than that in the conventional cement group. Conclusion: In conventional percutaneous vertebroplasty, the procedure of using autologous blood with cement decreased the polymerization temperature, reduced the setting time, and the incidence of cement leakage was low. These properties may contribute to more favorable mechanical properties that can reduce the complications compared to conventional cements alone.

A study on characteristics of palace wallpaper in the Joseon Dynasty - Focusing on Gyeongbokgung Palace, Changdeokgung Palace and Chilgung Palace - (조선시대 궁궐 도배지 특성 연구 - 경복궁, 창덕궁, 칠궁을 중심으로 -)

  • KIM Jiwon;KIM Jisun;KIM, Myoungnam;JEONG Seonhwa
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.1
    • /
    • pp.80-97
    • /
    • 2023
  • By taking wallpaper specimens from Gyeongbokgung Palace, Changdeokgung Palace, and Chilgung Palace preserved from the late Joseon Dynasty to the present, we planned in this study to determine the types and characteristics of the paper used as wallpaper in the Joseon royal family. First, we confirmed the features of paper hanging in the palaces with old literature on the wallpaper used by the royal family based on archival research. Second, we conducted a field survey targeting the royal palaces whose construction period was relatively clear, and analyzed the first layer of wallpaper directly attached to the wall structure after sampling the specimens. Therefore, we confirmed that the main raw material was hanji, which was used as a wallpaper by the royal family, and grasped the types of substances(dyes and pigments) used to produce a blue color in spaces that must have formality by analyzing the blue-colored paper. Based on the results confirmed through the analysis, we checked documents and the existing wallpaper by comparing the old literature related to wallpaper records of the Joseon Dynasty palaces. We also built a database for the restoration of cultural properties when conserving the wallpaper in the royal palaces. We examined the changes in wallpaper types by century and the content according to the place of use by extracting wallpaper-related contents recorded in 36 cases of Uigwe from the 17th to 20th centuries. As a result, it was found that the names used for document paper and wallpaper were not different, thus document paper and wallpaper were used without distinction during the Joseon Dynasty. And though there are differences in the types of wallpaper depending on the period, it was confirmed that the foundation of wallpaper continued until the late Joseon Dynasty, with Baekji(white hanji), Hubaekji(thick white paper), jeojuji(common hanji used to write documents), chojuji(hanji used as a draft for writing documents) and Gakjang(a wide and thick hanji used as a pad). As a result of fiber identification by the morphological characteristics of fibers and the normal color reaction(KS M ISO 9184-4: Graph "C" staining test) for the first layer of paper directly attached to the palace wall, the main materials of hanji used by the royal family were confirmed and the raw materials used to make hanii in buildings of palaces based on the construction period were determined. Also, as a result of analyzing the coloring materials of the blue decorative paper with an optical microscope, ultraviolet-visible spectroscopic analysis(UV-Vis), and X-ray diffraction analysis(XRD), we determined that the type of blue decorative paper dyes and pigments used in the palaces must have formality and identified that the raw materials used to produce the blue color were natural indigo, lazurite and cobalt blue.

Difference of perception of the duties of dental hygienist between dentists and dental hygiene students in an area (일개 지역 치과의사와 치위생학과 학생 간 치과위생사의 업무에 대한 인식의 차이)

  • Hwang, Soo-Jeong;Koong, Hwa-Soo;Lee, Sang-Hoon
    • Journal of Korean Academy of Dental Administration
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • Although dental hygienists have performed chair-side assisting and other dental cares as well as preventive dental cares in Korea, medical technician law confines duties of dental hygienists as closed narrative. The aim of this study was to investigate difference in perception of duties of dental hygienists in dental clinic between dentists and dental hygiene students. A total of 245 copies of questionnaires were distributed to dentists and students by post-mail. Only 42 dentists and 30 students in an area replied these questionnaires about the present and future duties of dental hygienists after providing written consent. Both groups agreed that intra and extra oral X-ray taking, education about oral health behavior, instruction after dental treatment, chair-side assisting, consulting for patients, scaling, initial impression taking, management of dental materials and equipment, sterilization of equipment, and receiving dental bills are duties of dental hygienists. However, they had different perceptions about various dental treatments as duties of dental hygienists even if they were under instructions of a dentist, including infiltration anesthesia, filling in cavity, intramuscular injection, FC change, canal irrigation, orthodontic treatment including separating, ligature bracket bonding and removing, setting crown and bridge, making individual, removing implant screw, and so on. These findings demonstrated that there were different perceptions about duties of dental hygienists between dentists and dental hygiene students, especially on dental treatment.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

An Analysis of the Characteristics of Glass Beads from the Joseon Dynasty Using Non-destructive Analysis (비파괴 분석을 활용한 조선시대 유리구슬의 특성 분석)

  • Lee Sujin;Kim Gyuho
    • Conservation Science in Museum
    • /
    • v.30
    • /
    • pp.71-88
    • /
    • 2023
  • This paper examined the visible characteristics and chemical composition of glass beads from the Joseon Dynasty as well as the associations thereof. It also explored the characteristics and uses of glass beads by region. This study covered a total of 1,819 pieces excavated from 25 locations in the Gyeonggi, Chungcheong, and Gyeongsang regions, of which 537 pieces were analyzed for their chemical composition. Glass beads of the Joseon Dynasty take a variety of shapes such as a Round, Coil, Floral, Segmented, Flat, Oval, and Calabash. Colors vary from shades of brown (brown, lemon yellow) and shades of blue (Bluish-Green, greenish-Blue, Purple-Blue) to shades of white (colorless, white) and shades of green (Green, Greenish-Blue, Greenish-Brown). Brown accounts for the largest percentage, followed by Bluish-Green, greenish-Blue. It was identified that Drawing technique was the most common glass bead production technique of the Joseon Dynasty. Potassium oxide (K2O) was the most common flux agent for glass beads, while the potash glass and mixed alkali glass groups account for the largest quantity. The choice of stabilizers depended on the type of flux agents used, but the most common were calcium oxide (CaO) and aluminum oxide (Al2O3). The potash glass and potash lead glass groups are high in CaO and low in Al2O3, the mixed alkali glass group is high in CaO, and the lead glass group is low in CaO. In terms of the association between color and shape, most of the beads with shade of brown and blue have round shapes of brown and blue have spherical shapes, while the coil shape is prominent in blue beads. A high percentage of green and colorless beads also take the shape of a coil, while white beads in general have a floral shape. In terms of the association between shape and chemical composition, round, floral and segmented shapes account for a high percentage of the potash glass group, while coil and flat shapes are common in the mixed alkali glass group. This paper also analyzed the colorants for each color based on the association between color and chemical composition. Iron (Fe) was used as the colorant for brown and white, and titanium (Ti) and iron were used for light yellow. Purple-Blue was produced by by cobalt (Co), and greenish-Blue, Bluish-Green, green, Greenish-Blue were produced by iron and copper (Cu). Colorless beads had a generally low colorant content.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

Mineralogical Analysis of Calcium Silicate Cement according to the Mixing Rate of Waste Concrete Powder (폐콘크리트 미분말 치환율에 따른 이산화탄소 반응경화 시멘트의 광물상 분석)

  • Lee, Hyang-Sun;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.2
    • /
    • pp.181-191
    • /
    • 2024
  • In the realm of cement manufacturing, concerted efforts are underway to mitigate the emission of greenhouse gases. A significant portion, approximately 60%, of these emissions during the cement clinker sintering process is attributed to the decarbonation of limestone, which serves as a fundamental ingredient in cement production. Prompted by these environmental concerns, there is an active pursuit of alternative technologies and admixtures for cement that can substitute for limestone. Concurrently, initiatives are being explored to harness technology within the cement industry for the capture of carbon dioxide from industrial emissions, facilitating its conversion into carbonate minerals via chemical processes. Parallel to these technological advances, economic growth has precipitated a surge in construction activities, culminating in a steady escalation of construction waste, notably waste concrete. This study is anchored in the innovative production of calcium silicate cement clinkers, utilizing finely powdered waste concrete, followed by a thorough analysis of their mineral phases. Through X-ray diffraction(XRD) analysis, it was observed that increasing the substitution level of waste concrete powder and the molar ratio of SiO2 to (CaO+SiO2) leads to a decrease in Belite and γ-Belite, whereas minerals associated with carbonation, such as wollastonite and rankinite, exhibited an upsurge. Furthermore, the formation of gehlenite in cement clinkers, especially at higher substitution levels of waste concrete powder and the aforementioned molar ratio, is attributed to a synthetic reaction with Al2O3 present in the waste concrete powder. Analysis of free-CaO content revealed a decrement with increasing substitution rate of waste concrete powder and the molar ratio of SiO2/(CaO+SiO2). The outcomes of this study substantiate the viability of fabricating calcium silicate cement clinkers employing waste concrete powder.

A Study on the Radioprotection Effect of Selenium and Arginine Mixtures for Reducing Radiation Damage to Police SOU (경찰특공대 요원의 방사선손상 감소를 위한 셀레늄과 아르기닌 혼합물의 방호효과 연구)

  • Geun-Woo Jeong;Hae-Suk Kim;Jae-Hyeong Park;Sung-Hyun Joo;Jae-Gyeong Choi;Se-Im Cheon;Byung-In Min
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2024
  • The purpose of this study is to examine the radioprotection effect of mixtures of selenium and arginine for development of radioprotection agents that can minimize radiation damage to police special operation unit in the event of radioactive terrorism. In this study 72 male rats were classified into 4 groups: normal group(NC Group), selenium and arginine mixtures administration group(SeAr Group), radiation exposure group(IR Group), and selenium and arginine mixture administration group followed by radiation exposure(SeAr+IR Group). The 7Gy of X-ray was irradiated to whole body of SD rats. And selenium and arginine were dministered orally at 3mg/kg and 150mg/kg once a day for 14 days. And then hematological and histological analyzes were performed on days 1, 7, and 21 after radiation exposure. In hemotological analysis, significant radioprotection wes observed in lymphocytes(p<0.05) on day 1, platelet(p<0.01) on day 7, red blood cell(p<0.01) on day 21 of radiation exposure in SeAr+IR group compared to IR group. In histological analysis, it was observed that the border of small crypt cells in the small intestine was less collapsed and the length of small crypts was relatively recovered on day 7 and showed that the number of cells and cell wall thickness were better in the prostate on day 21 in SeAr+IR group compared to IR group. Therefore, it is judged that selenium and arginine mixtures have radioprotection effect on blood and tissues due to radiation exposure. it will be helpful for research on radioprotection agents to reduce radiation damage to police special operation unit.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.