• 제목/요약/키워드: X-RD

검색결과 273건 처리시간 0.028초

Idiopathic Hypertrophic Cranial Pachymeningitis Misdiagnosed as Acute Subtentorial Hematoma

  • Park, Ik-Seong;Kim, Hoon;Chung, Eun-Yong;Cho, Kwang-Wook
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권2호
    • /
    • pp.181-184
    • /
    • 2010
  • A case of idiopathic hypertrophic cranial pachymeningitis (IHCP) misdiagnosed as an acute subdural hematoma is reported. A 37-year-old male patient presented with headache following head trauma 2 weeks earlier. Computerized tomography showed a diffuse high-density lesion along the left tentorium and falx cerebri. Initial chest X-rays revealed a small mass in the right upper lobe with right lower pleural thickening, which suggested lung cancer, such as an adenoma or mediastinal metastasis. During conservative treatment under the diagnosis of a subdural hematoma, left cranial nerve palsies were developed (3rd and 6th), followed by scleritis and uveitis involving both eyes. Magnetic resonance imaging (MRI) revealed an unusual tentorium-falx enhancement on gadolinium-enhanced T1-weighted images. Non-specific chronic inflammation of the pachymeninges was noticed on histopathologic examination following an open biopsy. Systemic steroid treatment was initiated, resulting in dramatic improvement of symptoms. A follow-up brain MRI showed total resolution of the lesion 2 months after steroid treatment. IHCP should be included in the differential diagnosis of subtentorial-enhancing lesions.

폐 Aspergillosis 의 외과적 치료 (Surgical treatment of pulmonary aspergillosis)

  • 유회성
    • Journal of Chest Surgery
    • /
    • 제17권2호
    • /
    • pp.269-274
    • /
    • 1984
  • Since tuberculosis was a common pulmonary disease in Korea, Aspergillosis was easily misdiagnosed as tuberculosis and an acute form of Aspergillosis was misinterpreted as pneumonia because of their similarities in the X-ray findings. This investigation is designed to illustrate the clinical features and preoperative diagnosis and surgical role in the management of this disease. In a retrospective review of operative cases from Jan. 1963 through Dec. 1983, 36 cases were analyzed. Peak age incidence lies in the 3rd decade [41.7%]. All cases had a history of treatment with antituberculous drugs under diagnosis of pulmonary tuberculosis and the most common chief complaint was hemoptysis [69.5%]. Only nine cases [25%] showed cavitary lesions with mycetoma and preoperative sputum study for fungus showed low positive valve [42.3%]. Anatomical location of lesion was located mainly upper lobe [66.7%] and most of cases were managed by lobectomy. We experienced 7 cases of complication; they were postoperative empyema, hepatic failure, esophageal varix bleeding. Postoperative pathologic findings showed that 29 cases [80.5%] were combined with tuberculosis 3 cases were combined with bronchiectasis and 4 cases were not combined with other disease. In conclusion, when the patient has a longstanding history of pulmonary tuberculosis and has a hemoptysis, he must be suspected fungus super infection. Resectional surgery is the treatment of choice for symptomatic localized disease and needed resection in asymptomatic patient to prevent possible fatal sequelae in the future.

  • PDF

고전압 전력기기응용을 위한 에폭시-나노콤포지트의 전기장 분산기술연구 (A Study on Electric Field Dispersion Techniques of Epoxy-Nanocomposites for Application of High Voltage Power Apparatus)

  • 이창훈;김효철;조영화;김현;정훈;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.97-97
    • /
    • 2010
  • A new electric application method was developed to prepare epoxy/organoclay nanocomposite for the electrical insulation in the AC electric fields and it could be also used in the field of various viscous polymer/organoclay systems. The applied AC electric field condition was as follows; (1) inter-electrode distance: 40 mm, (2) application voltage: 3-11 kV, (3) frequency: 60~1,000 Hz, and (4) application time: 0~60 min. To characterize the epoxy/clay nanocomposite, WAXS and TEM analyses were confirmed. In order to explain how the organic modifier affects the exfoliation phenomena, a mechanism of the oscillating collision of the quaternary ammonium head was proposed and the effects of the AC voltage and frequency and the organoclay content were studied.

  • PDF

균질기와 초음파 동시 분산을 통한 나노콤포지트의 구조적, 열적, 기계적특성 (Structural, Thermal and Mechanical Properties of Nano Composites according to Homogenizer and Power Ultrasonic)

  • 염규호;박광식;최성조;전상훈;곽영훈;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.82-82
    • /
    • 2010
  • 에폭시메트릭스 내에서 초음파 및 균질기를 이용하여 층상실리케이트 마이크로 입자의 균질분산을 위하여 사용하였다. 초음파와 균질기를 동시에 사용하여 최적의 적용시간과 충진나노입자 충진함량과의 관계를 연구하기위하여 구조적 특성으로 X-RD, 열적특성으로 DSC, 열적 기계적 특성으로 DMA를 사용하여 특성을 평가하였다. 충진함량 변화에 대해서 층상실리케이트의 층간사이 간격의 변화는 반비례하는 특성을 나타내었고, 충진함량이 증가됨에따라 자체만으로는 크게 응집된 입자의 분산이 미약한 결과로 볼 수 있다. 그러나 Homogenizer와 동시에 분산할 때는 충진함량이 크게 증가하여도 균질한 분산이 이루어졌다.

  • PDF

Accurate Characterization of T/R Modules with Consideration of Amplitude/Phase Cross Effect in AESA Antenna Unit

  • Ahn, Chang-Soo;Chon, Sang-Mi;Kim, Seon-Joo;Kim, Young-Sik;Lee, Juseop
    • ETRI Journal
    • /
    • 제38권3호
    • /
    • pp.417-424
    • /
    • 2016
  • In this paper, an accurate characterization of a fabricated X-band transmit/receive module is described with the process of generating control data to correct amplitude and phase deviations in an active electronically scanned array antenna unit. In the characterization, quantization errors (from both a digitally controlled attenuator and a phase shifter) are considered using not theoretical values (due to discrete sets of amplitude and phase states) but measured values (of which implementation errors are a part). By using the presented procedure for the characterization, each initial control bit of both the attenuator and the phase shifter is closest to the required value for each array element position. In addition, each compensated control bit for the parasitic cross effect between amplitude and phase control is decided using the same procedure. Reduction of the peak sidelobe level of an array antenna is presented as an example to validate the proposed procedure.

하이브리드 열가소성 복합재료의 압축성형에서 공정특성에 관한 연구 (A Study on the Processing Characteristic in the Compression Molding of Hybrid Thermoplastic Composites)

  • 허석봉;이중희;신귀수;이경엽
    • 대한기계학회논문집A
    • /
    • 제26권12호
    • /
    • pp.2550-2555
    • /
    • 2002
  • Hybrid composites usually are defined as composites having different types of reinforcements such as fibers and particles. The major advantage of hybrid composites is able to control the material properties such as optical, electrical, and mechanical properties. For this reason, hybrid composites are widely used in automotive, marine, household, and electrical industries. The objective of this work was to investigate processing characteristics in the compression molding of hybrid thermoplastic composites. The mechanical properties of composites manufactured in various forming conditions were monitored. The composites contained randomly oriented long carbon fiber and carbon black in polypropylene(PP) matrix were used. The carbon fiber contents of composites were 5%, 10%, 15%, and 20%, and carbon black contents were 5%, 10%, 15%, 20%, and 25% by weight. Compression molding was conducted at various mold temperatures. Crstallinity was also measured by using X-RD. The tensile modulus of the composites increased with increasing the mold temperature. However, the impact strength of the composites decreased as the mold temperature increased.

폐 Aspergollosis의 외과적 치료[제 2보] (Surgical Treatment of Pulmonary Aspergillosis[II])

  • 차경태
    • Journal of Chest Surgery
    • /
    • 제25권11호
    • /
    • pp.1292-1298
    • /
    • 1992
  • This investigation is designed to illustrate the clinical features '||'&'||' preoperative diagnosis, surgical role in the management of pulmonary aspergilloma, '||'&'||' compare with the previous study. We reviewed 42 cases of surgically treated pulmonary aspergillosis from Jan. 1984 to July 1992. The peak age incidence laid in the 2nd '||'&'||' 3rd decade of 25 cases[59.5%]. The 41 cases[97.6%] had a history of treatment with anti-tuberculous drugs under impression of pulmonary tuberculosis. The most common complaint was hemoptysis in 28 cases[66.7%]. The 21 cases showed so called "Air-meniscus sign" on the preoperative chest X-ray. As a preoperative diagnostic modality, the positivity was 30.0%, 57.8%, 88.5% on the fungus culture of sputum for Aspergillus, Chest CT, serum immunodiffusion test for A. fumigatus, respectively. The 37 cases[88.1%] can be diagnosed as pulmonary aspergillosis pre-operatively by any diagnostic method. The anatomical location of aspergilloma was mainly upper lobe in 17 cases[40.5%] '||'&'||' the majority of cases were managed by lobectomy. The postoperative pathologic findings showed that 18 cases[41.0%] were combined with tuberculosis '||'&'||' 15 cases[34.1%] were not combined with any other disease[Pr imary Aspergillosis]. The 6 cases showed postoperative empyema including 4 cases of bronchopleural fistula, 3 cases showed postoperative bleeding. One case was died postoperatively due to respiratory failure. In conclusion, when the patient who has longstanding history fo pulmonary tuberculosis '||'&'||' hemoptysis, must be suspected fungal super infection. The resectional surgery is the treatment of choice for symptomatic localized disease. And compare with the previous study, preop. chest CT '||'&'||' immunodiffusion test were more commonly available '||'&'||' showed high positivity.

  • PDF

여성가구주 근로자의 직무 스트레스와 정신건강 (Job Stress and Mental Health of Female Household Head Workers)

  • 김형선;권민;이진화
    • 한국직업건강간호학회지
    • /
    • 제25권4호
    • /
    • pp.249-258
    • /
    • 2016
  • Purpose: The purpose of this study is to identify job stress and psychological health of female household head workers and investigate the relationship between them. Methods: This study was cross-sectionally designed. We analysed the secondary data extracted from the 2nd and 3rd Korean Working Condition Survey. 4,807 female employees were included in the final analysis. $x^2$ test and multiple logistic regression using IBM SPSS 23.0 were performed. Results: 46.7% of female household head workers were in poor psychological health. In the area of job stress-related characteristics affecting the level of psychological health, it was found that female household head workers had a higher likelihood of becoming psychologically unhealthy due to organizational relationships and inadequate compensation factors. Conclusion: Considering the fact that the number of female household head workers is gradually expanding as a breadwinner, it is necessary to find a way of paying attention to their job stress and psychological health in order to support them.

자속구속형 고온초전도 전류제한기 동작 특성 (Operational characteristic of flux-lock type HTSC-FCL)

  • 임성훈;최효상;강형곤;고석철;이종화;최명호;송재주;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.20-23
    • /
    • 2003
  • The operational characteristics of flux-lock type high-Tc superconducting fault currentlimiters(HTSC-FCLs) was described and currents equation at each coil was derived from equivalent circuit. $YBa_{2}Cu_{3}O_{7-x}$(YBCO) thin film was used as the current limiting elements of the flux-lock type HTSC-FCL, which were fabricated by etching the YBCO thin film into 2 mm wide and 420 mm long meander line consisting of foureen stripes with different length. The 2nd peak on the current of coil 2 after a fault disappeared by current of the 3rd winding, which was installed in the flux-lock type HTSC-FCL.

  • PDF

홀로그래픽 간섭법을 이용한 편심하중에 의한 외팔보의 변형률분포 해석 (Strain analysis of cantilever beam under eccentric force using holographic interferometry)

  • 박승옥;김홍석;권혁홍;조동현
    • 한국광학회지
    • /
    • 제8권1호
    • /
    • pp.14-18
    • /
    • 1997
  • 홀로그래픽 간섭법을 이용하여 외팔보에 편심하중이 가해졌을 때 발생되는 변형을 해석하였다. 물체에 휨(bending)과 미소한 비틀림(torsion)의 복합변형이 발생될 때 사선의 홀로그래픽 간섭무늬를 얻었으며, 간섭무늬 개수와 경사도를 이용하여 변위분포함수를 근사적으로 구하여 간편하게 변형률분포를 해석할 수 있는 방법을 제시하였다. 자유단 근처에서의 최대 휨량이 9.7.+-.0.6.mu.m일 때, 고정단 부근에서 수직변형률의 최대값 e$_{x}$는 약 1.0 * $10^{-6}$, e$_{y}$ 는 약 -0.3 * $10^{-6}$이고, 전단변형률은 약 1.3 * $10^{-6}$으로 측정되었다. 본 방법의 신뢰성을 확인하기 위하여 FEM으로 변위 및 변형률을 이론적으로 해석하여 실험결과와 비교해 보았다.다.

  • PDF