• Title/Summary/Keyword: X-Probe

Search Result 610, Processing Time 0.031 seconds

Measurements of Five-Hole Pressure Probe on Swirling Flow Fields of Gun-Type Gas Burner for Furnace (온풍난방기용 Gun식 가스버너의 스월유동장에 대한 5공압력프로브의 측정)

  • Kim, Jang Kweon;Oh, Seok Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.991-997
    • /
    • 2014
  • This study investigated the swirling flow fields of a gun-type gas burner (GTGB) without a combustion chamber under cold flow conditions. Three velocity components and the static pressure were measured with a straight-type five-hole pressure probe (GHPP) using a non-nulling calibration method and compared with the results of an X-type hot-wire probe (X-probe) and computational fluid dynamics (CFD). The GHPP measured the velocity and static pressure for the swirling flow of the central region of the GTGB better than the X-probe but produced slightly worse results than the CFD.

Electromagnetic Micro x-y Stage for Probe-Based Data Storage

  • Park, Jae-joon;Park, Hongsik;Kim, Kyu-Yong;Jeon, Jong-Up
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.1
    • /
    • pp.84-93
    • /
    • 2001
  • An electromagnetic micro x-y stage for probe-based data storage (PDS) has been fabricated. The x-y stage consists of a silicon body inside which planar copper coils are embedded, a glass substrate bonded to the silicon body, and eight permanent magnets. The dimensions of flexures and copper coils were determined to yield $100{\;}\mu\textrm{m}$ in x and y directions under 50 mA of supplied current and to have 440 Hz of natural frequency. For the application to PDS devices, electromagnetic stage should have flat top surface for the prevention of its interference with multi-probe array, and have coils with low resistance for low power consumption. In order to satisfy these design criteria, conducting planar copper coils have been electroplated within silicon trenches which have high aspect ratio ($5{\;}\mu\textrm{m}$in width and $30{\;}\mu\textrm{m}$in depth). Silicon flexures with a height of $250{\;}\mu\textrm{m}$ were fabricated by using inductively coupled plasma reactive ion etching (ICP-RIE). The characteristics of a fabricated electromagnetic stage were measured by using laser doppler vibrometer (LDV) and dynamic signal analyzer (DSA). The DC gain was $0.16{\;}\mu\textrm{m}/mA$ and the maximum displacement was $42{\;}\mu\textrm{m}$ at a current of 180 mA. The measured natural frequency of the lowest mode was 325 Hz. Compared with the designed values, the lower natural frequency and DC gain of the fabricated device are due to the reverse-tapered ICP-RIE process and the incomplete assembly of the upper-sided permanent magnets for LDV measurements.

  • PDF

Cytogenetic and Molecular Genetic Studies on Duchenne Muscular Dystrophy (Duchenne Muscular Dystrophy에 관한 세포유전학 및 분자유전학적 연구)

  • Hong, Hea-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.7 no.1
    • /
    • pp.29-46
    • /
    • 2005
  • Purpose ; 본 연구는 X-염색체와 관련된 장애 중에서 가장 흔하고 심한 Duchenne Muscular Dystrophy(DMD)의 세포유전학 및 분자유전학적 특성을 설명하기 위해서 DMD에 영향을 받고 있는 두 가계의 13명을 대상으로 가계도 분석과 염색체 분석 및 DNA 분석을 하였다. Method ; DNA분석은 DNA probe을 이용한 Southern blotting method로써 RFLPs와 DMD유전자 부위의 exon소실 유무를 조사하여 아래와 같은 결과를 얻었다. Conclusion ; A 염색체 분석 : 말초혈액과 양수를 표본으로 High-Resolution GTG염색에서 A가계와 B가계의 염색체 분석에서 12명의 염색체는 정상 X-염색체였으나 B가계의 I-2(DMD여성)에서 46, x,-x,+t(2:x)(q 21.1 : p21.2)로 나타난다. B. DNA분석3 : 1) RFLPs의 분석 J66,XJ-1.1,754-11로써 B가계의 RELPs(Restriction Fragment Length Polymorphisms)에서 J66/Pst I은 1.7hb(E), 1.6kb(e)을 보여 주었고 XJ-1.1/Taq I은 3.6kb(F), 3.0kb(f), 754-11/EoR I은 4.2kb(G), 2.0kb(g)의 대립인자를 나타내었다. 이상의 결과를 바탕으로 영향을 받고 있는 남자 (II-2)의 haplotype는 보인자인 어머니의 한쪽 인자를 받았으며 어머니와 딸은 보인자이고 임산부의 태아는 남아였고 태아의 인자들은 그의 할아버지로부터 물려받아 DMD에 영향을 받지 않은 것으로 진단되었다. 2) DMD 유전자의 exon 소실에 대한 분석 cDNA probe 8과 cDNA probe 2b-3으로써 소실에 대한 진단은 영향을 받은 남자(II-2)는 cDNA probe 8에서 12, 7.3, 6.6, 4.2kb에 소실이 있고 cDNA 2b-3은 1.7kb에 소실에 나타났다.

  • PDF

Design of the Slider and Suspension for 4x1 Near-field Probe Array in Micro Optical Disk Drives (마이크로 광디스크 드라이브용 4x1 근접장 탐침 어레이를 위한 슬라이더와 서스펜션의 설계)

  • Hong, Eo-Jin;Jung, Min-Su;Oh, Woo-Seok;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.393-398
    • /
    • 2004
  • The near-field scanning micro scope (NSOM) technique is in the spotlight as the next generation storage device. Many different types of read/write mechanism for NSOM have been introduced in the literature. In order for a near-field probe to be successfully implemented in the system, a suitable slider and suspension are needed to be properly designed. The optical slider is designed considering near-filed optics and probe array. The suspension generally supports slider performance, and tracking servo capacity in HDD. Moreover, the suspension for optical slider also should meet the optical characteristics, and is also required to satisfy shock performances for the mobility for the actuator. In this study, the optical slider and the suspension fer near-field probe array are designed and analyzed.

  • PDF

Investigation on the Turbulent Flow Field Characteristics of a Gun-Type Gas Burner with and without a Duct (덕트의 유무에 따른 Gun식 가스버너의 난류유동장 특성 고찰)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.17-24
    • /
    • 2006
  • The turbulent flow field characteristics of a gun-type gas burner with and without a duct were investigated under the isothermal condition of non-combustion. Vectors and mean velocities were measured by hot-wire anemometer system with an X-type hot-wire probe in this paper. The turbulent flow field with a duct seems to cause a counter-clockwise recirculation flow from downstream to upstream due to the unbalance of static pressure between a main jet flow and a duct wall. Moreover, the recirculation flow seems to expand the main jet flow to the radial and to shorten it to the axial. Therefore, the turbulent flow field with a duct increases a radial momentum but decreases a axial momentum. As a result, an axial mean velocity component with a duct above the downstream range of about X/R=1.5 forms a smaller magnitude than that without a duct in the inner part of a burner, but it shows the opposite trend in the outer part.

  • PDF

Characterization of Asian Dust Using Low-Z Electron Probe X-ray Microanalysis (Low-Z Electron Probe X-ray Microanalysis를 이용한 황사 입자의 특성 분석)

  • 황희진;노철언;김혜경
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.350-351
    • /
    • 2002
  • 대기 중 부유 입자상물질(에어로졸)은 지구 대기 환경과 기후, 그리고 인체 건강에 영향을 미치는 까닭에, 에어로졸을 효과적으로 분석하는 방법을 개발하는 연구는 매우 중요하다. 특히 한국과 일본에서는 매년 봄 중국에서 발원하여 동북부 아시아로 이동하는 황사(Asian Dust) 현상이 매우 중요한 관심 대상이다. 이것은 황사 입자가 중국의 공업단지인 중국 북동부를 거쳐오면서, 황산염이나 질산염, 해염 입자와 반응하여 한국이나 일본, 태평양으로 이동시킬 수 있다는 점에서 중요하게 여겨진다. (중략)

  • PDF

Pathogen-Imprinted Polymer Film Integrated probe/Ti3C2Tx MXenes Electrochemical Sensor for Highly Sensitive Determination of Listeria Monocytogenes

  • Xiaohua, Jiang;Zhiwen, Lv;Wenjie, Ding;Ying, Zhang;Feng, Lin
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.431-437
    • /
    • 2022
  • As one of the most hazardous and deadliest pathogens, Listeria monocytogenes (LM) posed various serious diseases to the human being, thus designing effective strategy for its detection is of great significance. In this work, by preparing Ti3C2Tx MXenes nanoribbon (Ti3C2TxR) as carrier and selecting thionine (Th) acted simultaneously as signal probe and functional monomer, a LM pathogen-imprinted polymers (PIP) integrated probe electrochemical sensor was design to monitor LM for the first time, that was carried out through the electropolymerization of Th on the Ti3C2TxR/GCE surface in the existence of LM. Upon eluting the templates from the LM imprinted cavities, the fabricated PIP/Ti3C2TxR/GCE sensor can rebound LM cells effectively. By recording the peak current of Th as the response signal, it can be weakened when LM cell was re-bound to the LM imprinted cavity on PIP/Ti3C2TxR/GCE, and the absolute values of peak current change increase with the increasement of LM concentrations. After optimizing three key parameters, a considerable low analytical limit (2 CFU mL-1) and wide linearity (10-108 CFU mL-1) for LM were achieved. In addition, the experiments demonstrated that the PIP/Ti3C2TxR sensor offers satisfactory selectivity, reproducibility and stability.

Narrow Resonant Double-Ridged Rectangular Waveguide Probe for Near-Field Scanning Microwave Microscopy

  • Kim, Byung-Mun;Son, Hyeok-Woo;Cho, Young-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.406-412
    • /
    • 2018
  • In this paper, we propose a narrow resonant waveguide probe that can improve the measurement sensitivity in near-field scanning microwave microscopy. The probe consists of a metal waveguide incorporating the following two sections: a straight section at the tip of the probe whose cross-section is a double-ridged rectangle, and whose height is much smaller than the waveguide width; and a standard waveguide section. The advantage of the narrow waveguide is the same as that of the quarter-wave transformer section i.e., it achieves impedance-matching between the sample under test (SUT) and the standard waveguide. The design procedure used for the probe is presented in detail and the performance of the designed resonant probe is evaluated theoretically by using an equivalent circuit. The calculated results are compared with those obtained using the finite element method (Ansoft HFSS), and consistency between the results is demonstrated. Furthermore, the performance of the fabricated resonant probe is evaluated experimentally. At X-band frequencies, we have measured the one-dimensional scanning reflection coefficient of the SUT using the probe. The sensitivity of the proposed resonant probe is improved by more than two times as compared to a conventional waveguide cavity type probe.

Crystal structure analysis of orthohombic $Sr_{0.6}Ca_{0.4}CuO_2$ compound (사방정계 $Sr_{0.6}Ca_{0.4}CuO_2$ 화합물의 결정구조해석)

  • Park, H.M.;Goetz, D.;Hahn, Th.
    • Korean Journal of Crystallography
    • /
    • v.7 no.1
    • /
    • pp.20-29
    • /
    • 1996
  • Sr0.6Ca0.4CuO2 single crystal has been synthesized by flux method and characterized by the single crystal X-ray diffraction. The compound has the orthorhombic system and the space group is Cmcm(63), lattice parameters are a=3.4645Å, b=16.1417Å, c=3.8727Å. In the (Sr1-xCax)CuO2 compound the limit of Ca from substitution for Sr was determined by the change of bond length. For this, X-ray diffraction, scanning electron microscopy (SEM), energy dispersive X-ray fluorescence (EDAX) and electron probe micro-analysis (EPMA) were used. From the change of Cu-O bond length as the Ca substitution, we concluded the limit of Ca incorporation Xca≒0.73.

  • PDF