• Title/Summary/Keyword: X-선 필름 판독

Search Result 5, Processing Time 0.018 seconds

Issues in Ancient Metal Wire Inlay: A Case Study of Relics from Baekje (고대 금속 선상감 기법의 쟁점과 그 해석 - 백제 선상감 자료를 중심으로 -)

  • Choi, Gieun
    • Conservation Science in Museum
    • /
    • v.20
    • /
    • pp.13-30
    • /
    • 2018
  • Ancient metal objects with inlaid designs were mainly decorated using the wire inlay technique in which "V"- or "U"-shaped grooves were cut in a metal object and then filled with gold or silver. Previous studies on ancient metal objects featuring wire inlay generally attempted to ascertain the inlay techniques applied by examining photomicroscopes acquired during conservation treatment. However, they had limitations when examining wire inlay technique to the minute details. Wire inlay technique can be better investigated by enlarging X-ray films of relics using stereoscopic microscopy under transmitted light. The core processes of the wire inlay technique involve cutting grooves using a chisel and creating the inlay wires, but researchers hold varying opinions about the two processes. This study analyzed the entirety of the materials able to shed light on the main processes applied in Baekje wire inlay by examining X-ray films of relics through stereoscopic microscopy. This exhaustive research revealed that two types of techniques were used for wire inlay during the Baekje period. One is a plastic process of engraving dotted lines using a chisel and is found mostly in objects from the Cheonan and Gongju areas. The other is a cutting process that incises fine lines and was used mostly in relics from the Osan, Seosan, and Wanju areas. It is likely that the Baekje wire inlay techniques feature regional differences because the respective techniques were used or introduced by different groups of people.

A Detection of the Microcalcification using fractal Dimension on Mammograms (Mammogram에 있어서 Fractal Dimension을 이용한 Microcalcification 검출)

  • 남상희;최준영;서지현
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 1998.04a
    • /
    • pp.128-132
    • /
    • 1998
  • 유방암의 조기진단을 위한 수단으로 Mammography의 x-선 film-screen이 많이 사용된다. 그러나, Mammogram에서 정상조직과 암조직 간의 대조도 차이가 크지 않으므로 판독은 그다지 쉽지가 않다. 이러한 문제들의 해결을 위하여 mammogram의 디지털 화상처리 및 분석 연구가 활발히 진행 중이다. 본 연구에서는 진단방사선의들이 필름을 판독할 때 시각적인 인지도를 높여주고, 보다나은 의료지원 서비스의 제공을 위한 목적으로, 유방암의 조기진단의 중요한 요소인 미세석회의 검출을 위한 방법으로서 fractal dimension을 구하여 종괴와 미세석회, 미세석회에 대한 차이를 분석하고자 하였다. 각각의 실험군에 대하여 30명씩 60명의 데이터를 0.1mm resolution의 12bit gray scale로 획득하여 사용하였는데, 일차로 화상의 대조도 개선을 위하여 처리를 하였고 화상의 분석으로 강조된 화상의 불규칙정도 및 거친 정도를 나타내기 위하여 fractal dimension을 계산하였다. 원화상에서 가시적으로 분간하기 힘들었던 병변을 화상처리를 통해 강조된 화상에서는 쉽게 그 특징을 볼 수 있었다. 실제로 mammogram을 진단할 때, 강조화상으로 미세석회와 같은 조기진단의 가시적인 판단을 도모할 수 있으며, 미세석회의 진단에서 fractal dimension값을 이용하여 병변 특성의 하나로서 사용할 수 있을 것으로 판단된다.

  • PDF

이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발

  • 김새롬;김희중;정해조;강원석;이재훈;이상호;신성범;유선국
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.81-81
    • /
    • 2003
  • 목적 : 현재, 많은 병원이 방사선과 의료영상정보를 기존의 필름형태로 판독하고, 진료하는 방식에서 PACS 를 도입하여 디지털 형태로 영상을 전송, 저장, 검색, 판독하는 환경으로 변화하고 있다. 한편, PACS 가 가지는 가장 큰 제한점은 휴대성의 결핍이다. 본 연구는 이동형 장치가 가지는 호스트의 이동성 및 휴대성의 장점들을 살리면서, 무선 채널 용량의 한계, 무선 링크 사용이라는 제약점들을 감안하여 의료영상을 JPEG2000 영상압축 방식으로 부호화한 후 무선 환경을 고려한 전송 패킷의 크기를 결정하고자 하였으며, 무선 통신 중 발생되는 패킷 손실에 대응하기 위한 자동 오류 수정 기능도 함께 구현하고자하였다. 방법 : Window 2000 운영체계에서 의료영상을 로드하고, 데이터베이스화하며, 저장하고, 다른 네트워크와 접속, 제어가 가능한 PC급 서버를 구축하였다. 영상데이터는 무선망을 통해 전송하기 때문에 가장 높은 압축비율을 지원하면서 에너지 밀도가 높은 JPEG2000 알고리즘을 사용하여 영상을 압축하였다. 또한, 무선망 사용으로 인한 패킷 손실에 대비하여, 영상을 JPEG2000 방식으로 부호화한 후 각 블록단위로 전송하였다. 결과 : PDA에서 JPEG2000 영상을 복호화 하는데 걸리는 시간은 256$\times$256 크기의 MR 뇌영상의 경우 바로 확인할 수 있었지만, 800$\times$790 크기의 CR 흉부 영상의 경우 약 5 초 정도의 시간이 걸렸다. CDMA 1X(Code Division Multiple Access 1st Generation) 모듈을 사용하여 영상을 전송하는 경우, 256 byte/see 정도에서는 안정된 전송 결과를 보여주었고, 1 Kbyte/see 정도의 전송의 경우 중간 중간에 패킷이 손실되는 결과를 관찰할 수 있었다. 반면 무선 랜의 경우 이보다 더 큰 패킷을 전송하더라도 문제점은 발견되지 않았다. 결론 : 현재의 PACS는 유선과 무선사이의 인터페이스의 부재로 인해 유무선 연동이 되지 못하고 있다. 따라서 이동형 JPEG2000 영상 뷰어는 PACS가 가지는 문제점인 휴대성을 보완하기 위하여 개발되었다. 또한 무선망이 가지는 데이터 손실에 대하여서도 허용할 수 있는 범위에서 재전송을 가능하게 함으로서 약한 연결성을 보완하였다. 본 JPEG2000 영상 뷰어 시스템은 기존 유선상의 PACS와 이동형 장치간에 유기적인 인터페이스 역할을 하리라 기대된다.

  • PDF

Development of JPEG2000 Viewer for Mobile Image System (이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발)

  • 김새롬;정해조;강원석;이재훈;이상호;신성범;유선국;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.124-130
    • /
    • 2003
  • Currently, as a consequence of PACS (Picture Archiving Communication System) implementation many hospitals are replacing conventional film-type interpretations of diagnostic medical images with new digital-format interpretations that can also be saved, and retrieve However, the big limitation in PACS is considered to be the lack of mobility. The purpose of this study is to determine the optimal communication packet size. This was done by considering the terms occurred in the wireless communication. After encoding medical image using JPGE2000 image compression method, This method embodied auto-error correction technique preventing the loss of packets occurred during wireless communication. A PC class server, with capabilities to load, collect data, save images, and connect with other network, was installed. Image data were compressed using JPEG2000 algorithm which supports the capability of high energy density and compression ratio, to communicate through a wireless network. Image data were also transmitted in block units coeded by JPEG2000 to prevent the loss of the packets in a wireless network. When JPGE2000 image data were decoded in a PUA (Personal Digital Assistant), it was instantaneous for a MR (Magnetic Resonance) head image of 256${\times}$256 pixels, while it took approximately 5 seconds to decode a CR (Computed Radiography) chest image of 800${\times}$790 pixels. In the transmission of the image data using a CDMA 1X module (Code-Division Multiple Access 1st Generation), 256 byte/sec was considered a stable transmission rate, but packets were lost in the intervals at the transmission rate of 1Kbyte/sec. However, even with a transmission rate above 1 Kbyte/sec, packets were not lost in wireless LAN. Current PACS are not compatible with wireless networks. because it does not have an interface between wired and wireless. Thus, the mobile JPEG2000 image viewing system was developed in order to complement mobility-a limitation in PACS. Moreover, the weak-connections of the wireless network was enhanced by re-transmitting image data within a limitations The results of this study are expected to play an interface role between the current wired-networks PACS and the mobile devices.

  • PDF

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.