• Title/Summary/Keyword: X-선 촬영

Search Result 358, Processing Time 0.026 seconds

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

A Study of Lung Cancers Without Demonstrable Mass Lesions on Simple Chest X-rays (단순흉부 X-선촬영상 종괴가 보이지 않았던 폐암에 관한 연구)

  • Suh, Gee-Young;Jeong, Ki-Ho;Yoo, Chul-Kyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keon-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.1
    • /
    • pp.15-23
    • /
    • 1992
  • Background: The prognosis of lung cancer remains poor and early detection and curative surgery is still the most effective treatment for many. In the early detection of lung cancer, sputum cytology and simple chest x-ray are used, but both of these tests are far from being perfect. So we studied the characteristics of patients diagnosed as lung cancer without demonstrable mass lesion on simple chest x-ray to help in the early diagnosis of lung cancer. Methods: We conducted a retrospective study on 11 subjects who were diagnosed as lung cancer at Seoul National University Hospital between August 1986 and June 1989 and had no demonstrable mass lesion on simple chest x-rays. Results: Ten of 11 patients were male, 8 had a history of smoking, most frequent symptoms were sputum, cough, and hemoptysis, and 3 patients either had wheezing or stridor. In 3 of the cases, although there were no mass lesion, there were ill-defined infiltration, major fissure thickening, and fibrostreaky density mimiking tuberculosis where the tumor was eventually found and in one patient tumor was masked by a rib shadow. Also in one case, lateral chest film demonstrated a retrocardiac mass. Both bronchoscopy and computed tomogram were useful in the localization of the tumor. Seven of 11 had relatively early disease (less than StageII). Four of 11 are still alive without any evidence of recurrence between 2 and a half and 4 years after the operation. Conclusion: We conclude that in patients with respiratory symtoms in whom cancer cannot be ruled out, sputum cytology and lateral chest x-rays should be taken and that if necessary further studies like computed tomogram and bronchoscopy should be done to aid in the early diagnosis of lung cancer.

  • PDF

A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography (진단용 X-선 촬영시 부가 필터 및 노출의 변화에 따른 피폭선량 및 영상 화질 비교 연구)

  • Choi, Nam-Gil;Seong, Ho-Jin;Jeon, Joo-Seop;Kim, Youn-Hyun;Seong, Dong-Ook
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • To know which parameters were acceptable for achieving lowest radiation exposure to the patients and highest image quality at the diagnostic X-ray radiography, we measured the patient radiation dose and image quality in transmitted PACS (Picture Archiving and Communication System) at variable combinations of the added filters. As a result, the Dose Area Product (DAP: $mGy{\cdot}cm^2$) and Entrance Surface Doses (ESDs: $mGy$) was lowest at 1 mmAl + 0.2 mmCu and highest at 0 mmAl. The histogram of the image quality by transmitted PACS was not significantly different at variable combinations of exposure parameters on the MATLAB. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic X-ray radiography.

Auto-Positioning of Patient in X-ray Diagnostic Imaging (진단 엑스선 영상에서 환자 위치잡이의 자동화)

  • Yang, Won Seok;Son, Jung Min;Kwon, Su Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.793-799
    • /
    • 2018
  • As interest in artificial intelligence has increased, artificial intelligence has been actively studied in the medical field. In Korea, artificial intelligence has been applied to medical imaging devices such as X-ray imaging, Computer Tomography and Magnetic Resonance Imaging and artificial intelligence capable of acquiring radiation images of patients without radiologists in the future Medical devices are expected to be invented. This study was an initial study on the automation of patient positioning in X - ray imaging. We used x-ray equipment and human phantoms to evaluate the positioning. The program used Visual Studio 2010 MFC and the image was in the size $1450{\times}1814$. The pixel values were converted to contrasts with values of 0 to 255 that can be visually recognized and output to the monitor. We developed a procedure algorithm program that predicts the angle of the output image through three pixel coordinate values and induces the patient to perform correct positioning according to the voice guidance according to the angle. In the next study, we will study the artificial intelligence to grasp the structure itself and calculate the angle, rather than conveying the reference of coordinates to artificial intelligence. In the future, it is expected that it will be helpful in the study of artificial intelligence from shooting to positioning through the automation of positioning.