• 제목/요약/키워드: X ray image

검색결과 1,290건 처리시간 0.026초

A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes

  • Cho, Jae-Hun;Kim, Jae-Yun;Kang, Joo-Eun;Park, Pyong-Eun;Kim, Jae-Hun;Lim, Jeong-Ae;Kim, Hae-Kyoung;Woo, Nam-Sik
    • The Korean Journal of Pain
    • /
    • 제24권4호
    • /
    • pp.199-204
    • /
    • 2011
  • Background: Although many clinicians know about the reducing effects of the pulsed and low-dose modes for fluoroscopic radiation when performing interventional procedures, few studies have quantified the reduction of radiation-absorbed doses (RADs). The aim of this study is to compare how much the RADs from a fluoroscopy are reduced according to the C-arm fluoroscopic modes used. Methods: We measured the RADs in the C-arm fluoroscopic modes including 'conventional mode', 'pulsed mode', 'low-dose mode', and 'pulsed + low-dose mode'. Clinical imaging conditions were simulated using a lead apron instead of a patient. According to each mode, one experimenter radiographed the lead apron, which was on the table, consecutively 5 times on the AP views. We regarded this as one set and a total of 10 sets were done according to each mode. Cumulative exposure time, RADs, peak X-ray energy, and current, which were viewed on the monitor, were recorded. Results: Pulsed, low-dose, and pulsed + low-dose modes showed significantly decreased RADs by 32%, 57%, and 83% compared to the conventional mode. The mean cumulative exposure time was significantly lower in the pulsed and pulsed + low-dose modes than in the conventional mode. All modes had pretty much the same peak X-ray energy. The mean current was significantly lower in the low-dose and pulsed + low-dose modes than in the conventional mode. Conclusions: The use of the pulsed and low-dose modes together significantly reduced the RADs compared to the conventional mode. Therefore, the proper use of the fluoroscopy and its C-arm modes will reduce the radiation exposure of patients and clinicians.

유기금속화학기상증착법을 이용한 청색 발광 InGaN/GaN MQWs의 성장에 관한 연구 (Growth of Blue Light Emitting InGaN/GaN MQWs by Metalorganic Chemical Vapor Deposition)

  • 김동준;문용태;송근만;박성주
    • 대한전자공학회논문지SD
    • /
    • 제37권12호
    • /
    • pp.11-17
    • /
    • 2000
  • 저압 유기금속화학기상증착법을 이용하여 효율적인 청색 발광을 하는 InGaN/GaN multiple quantum wells(MQWs)을 성장시키고, InGaN/GaN MQWs의 광학적 및 계면 구조 특성을 고찰하였다. 보다 효율적인 청색 발광을 하는 InGaN/GaN MQWs을 성장시키기 위하여, MQWs의 성장온도 및 InGaN 우물층과 GaN 장벽층의 두께를 변화시켜 최적 조건을 확립하였다. 특히, GaN 장벽층의 두께 변화가 InGaN 우물층과 GaN 장벽층간 계면의 구조적 특성에 지대한 영향을 미침을 확인하였다. X-ray 회절분석결과와 고분해능의 투과전자현미경 사진 분석으로부터 MQW 구조의 InGaN 우물층과 GaN 장벽층간의 계면이 매우 급준함을 발견할 수 있었다. 또한, 상온 PL 스펙트럼에서 72.6meV의 매우 좁은 반치폭을 갖는 단일 피크가 463.5nm에서 확인되었다.

  • PDF

수열합성법으로 합성된 산화아연 나노 구조 박막의 광촉매적 응용 (Hydrothermally Synthesis Nanostructure ZnO Thin Film for Photocatalysis Application)

  • ;남민식;;전성찬
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.97-101
    • /
    • 2016
  • 산화아연은 다양한 나노 구조와 특유의 특성으로 인하여 여러 분야에서 많은 관심을 받고있는 물질이다. 산화아연을 합성하는 다양한 방법 중에서, 수열합성법은 간단하고 친환경적인 장점을 가지고 있다. 나노 구조를 가지는 산화아연 박막은 수열합성법을 통하여 FTO 전극 위에 제작되었다. 성장된 산화아연은 X-ray diffraction (XRD)와 Field-emission scanning electron microscopy (FESEM)을 통하여 분석되었다. XRD 분석에서 산화아연 박막이 자연상태의 hexagonal wurtzite 상으로 구성되어 있음을 확인하였으며 SEM 사진에서는 나노 로드 형태를 구성하고 있는 것을 확인할 수 있었다. 본 연구에서는 UV 영역의 흡수 스펙트럼을 분석하여 산화아연이 보이는 365 nm 파장에서의 흡수를 확인하였다. 또한 photoluminescence 방출을 분석한 결과, 424 nm의 band edge emission과 500 nm에서 산화아연의 oxygen vacancies에 의한 방출을 확인하였다. 또한 라만 스펙트럼 분석을 통하여 본 연구진이 제작한 산화아연이 높은 결정성을 가지고 있는 것을 확인할 수 있었다. 이러한 연구를 통하여 다양한 특성을 가진 산화아연의 광촉매적 적용을 기대할 수 있다.

Si (001) 기판에서 $N_2$처리에 의해 형성된 에피택셜 C49-$TiSi_2$상의 열적 거동과 결정학적 특성에 관한 연구 (Thermal Behavior and Crystallographic Characteristics of an Epitaxial C49-$TiSi_2$ Phase Formed in the Si (001) Substrate by $N_2$Treatment)

  • 양준모;이완규;박태수;이태권;김중정;김원;김호정;박주철;이순영
    • 한국재료학회지
    • /
    • 제11권2호
    • /
    • pp.88-93
    • /
    • 2001
  • $N_2$처리에 의해 Si (001) 기판에 형성된 C49상의 구조를 갖는 에피택셜 $TiSi_2$상의 열적 거동과 결정학적 특성을 X선 회절법 (XRD)과 고분해능 투과전자현미경법 (HRTEM)으로 조사하였다. 에피택결 $C49-TiSi_2$상은 $1000^{\circ}C$ 정도의 고온에서도 안정상인 C54상으로 상변태하지 않고 형태적으로도 고온 특성이 우수하다는 것이 밝혀졌다. HRTEM 결과로부터 에피택결 $TiSi_2$상과 Si 사이의 결정학적 방위관계는 (060) [001]TiSi$_2$//(002) [110]Si임을 알 수 있었고 계면에서의 격자 변형에너지는 misfit 전위의 형성에 의하여 해소되는 것을 확인할 수 있었다. 또한 HRTEM상의 해석과 원자 모델링을 통하여 Si에서 에피택셜 C49-TiSi$_2$상의 형성기구와 C49상의 (020) 면에 존재하는 적층결함을 고찰하였다.

  • PDF

디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구 (The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography)

  • 신수인;김종일;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권3호
    • /
    • pp.223-228
    • /
    • 2008
  • 의학적으로 방사선을 사용 시 가장 중요한 점은 환자의 병을 진단 가능하되 피폭선량을 최소화시켜야 한다는 점이다. 진단용 X-선 중 장파장부분은 대부분 흡수에 관여하게 되어 환자의 피폭선량을 증가시키므로 불필요하다. 이러한 장파장영역을 제거하기 위한 방법으로 가장 효과적인 방법은 여과 판의 사용이다. 이에 부가여과가 없는 경우와 0.3mmCu filter 사용 시의 화질과 피부입사선량에 대해 실험을 해 보았다. ROC 신호용 지름 4mm, 두께 3mm의 아크릴 디스크를 chest phantom에 랜덤하게 위치시키면서 non filter 및 Cu filter시 각 각 20매씩 총 40매의 신호+잡음영상을 촬영하고, 또한 신호가 없는 영상(잡음만의 영상)을 각 각 20매씩 40매 촬영하여 총 80매의 영상을 준비한 후 5명의 방사선종사자가 판독 후 P(S/s), P(S/n) 구하여, ROC곡선을 그리고, 감도와 특이도 및 곡선하면적을 구해 평가하였다. 또한 AAPM(American Association of Physicists in Medicine by the American Institute of Physics)권고에 따른 ANSI chest phantom과 Contrast-detail phantom을 이용하여 non filter 또는 Cu filter사용 시 시각적으로 관찰 가능한 병소의 갯수를 파악하였으며, 또한 두 경우에서 피부입사선량을 측정하였다. 그 결과 Cu filter사용 시에 ROC곡선이 좌상방향에 위치하고, 감도, 곡선하면적 및 CD phantom 병소의 갯수에서 모두 좋은 결과를 나타내었다. 또한 피부입사선량은 감소가 되어 여러 측면에서 부가필터의 사용을 검토해 볼 필요가 있으리라 사료된다.

  • PDF

$Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ 구조의 전기적 특성 분석 및 $SrTiO_3$박막의 완충층 역할에 관한 연구 (Electrical Properties in $Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ Structure and the Role of $SrTiO_3$ Film as a Buffer Layer)

  • 김형찬;신동석;최인훈
    • 한국전기전자재료학회논문지
    • /
    • 제11권6호
    • /
    • pp.436-441
    • /
    • 1998
  • $Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ structure was prepared by rf-magnetron sputtering method for use in nondestructive read out ferroelectric RAM(NDRO-FEAM). PBx(Zr_{0.52}Ti_{0.48})O_3}$(PZT) and $SrTiO_3$(STO) films were deposited respectively at the temperatures of $300^{\circ}C and 500^{\circ}C$on p-Si(100) substrate. The role of the STO film as a buffer layer between the PZT film and the Si substrate was studied using X-ray diffraction (XRD), Auger electron spectroscopy (ASE), and scanning electron microscope(SEM). Structural analysis on the interfaces was carried out using a cross sectional transmission electron microscope(TEM). For PZT/Si structure, mostly Pb deficient pyrochlore phase was formed due to the serious diffusion of Pb into the Si substrate. On the other hand, for STO/PZT/STO/Si structure, the PZT film had perovskite phase and larger grain size with a little Pb interdiffusion. the interfaces of the PZT and the STO film, of the STO film and the interface layer and $SiO_2$, and of the $SiO_2$ and the Si substate had a good flatness. Across sectional TEM image showed the existence of an amorphous layer and $SiO_2$ with 7nm thickness between the STO film and the Si substrate. The electrical properties of MIFIS structure was characterized by C-V and I-V measurements. By 1MHz C-V characteristics Pt/STO(25nm)/PZT(160nm)/STO(25nm)/Si structure, memory window was about 1.2 V for and applied voltage of 5 V. Memory window increased by increasing the applied voltage and maximum voltage of memory window was 2 V for V applied. Memory window decreased by decreasing PZT film thickness to 110nm. Typical leakage current was abour $10{-8}$ A/cm for an applied voltage of 5 V.

  • PDF

CR X선 영상의 복합잡음 감소에 관한 연구 (Mixed Noise Reduction Filters for CR Images)

  • 민정환;정회원;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권1호
    • /
    • pp.1-6
    • /
    • 2007
  • 인위적으로 noise factor를 주고 그 위에 촬영을 하여 노이즈와 영상의 복합물을 만들었다. 그 후 Low Pass Filter(LPF)와 Median Filter(MF)의 두 종류의 필터를 통하여 노이즈를 제거하고 노이즈를 나타내는 지표로 Signal To Noise Ratio(SNR), Peak Signal to Noise Ratio(PSNR), Mean Square Error(MSE)를 비교하였다. 또한 Median Filter의 kernel size에 따라서도 노이즈제거효과를 평가하였다. 각각의 처리된 영상과 원 영상을 비교하여 원 영상에 가까운 영상을 찾아봄으로서 어떤 필터가 유용하며 어떤 주파수대를 제거해야 하는가를 알고자 실험하였다. Cutoff frequency가 다른 필터를 비교 했을 때 noise power 값에는 상관없이 cutoff frequency $2/3\pi{\sim}3/4\pi$까지가 원 영상에 가까우면서 SNR, PSNR이 좋다. 따라서 높은 filter 효과를 나타낸다고 할 수 있다. Median filter의 kernel size가 커짐에 따라서 SNR 값이 커지며 반대로 MSE의 값이 작아져 filter 효과는 좋아 짐을 알 수 있다. 의료 영상에 filter를 적용하는 것에 대해서 대부분의 영상들이 filter 적용 후에 왜곡된 상이 되곤 하였다. 의료 영상은 다른 영상과는 달리 공간 분해능을 유지하면서 평활화(노이즈 제거)하는 것이 중요한 문제이다. SNR 등 정량적 지표에 의한 비교와 함께 시각적 평가가 병행되어야 할 필요가 있다.

  • PDF

자동 영상분석 계기를 이용한 골 유도재생능력의 분석에 관한 조직계측학적 연구 (Study on the histomorphometry of guided bone regeneration using automated image analysis system)

  • 김태일;구영;류인철;정종평;한수부;최상묵;손성희
    • Journal of Periodontal and Implant Science
    • /
    • 제26권3호
    • /
    • pp.771-778
    • /
    • 1996
  • The assessment of alveolar bone changes on dental radiographs to indicate progression of periodontal diseases or healing response to therapy is routine procedure. However, the diagnostic accuracy in detecting small alveolar bone changes is very limited. Recently, guided bone regeneration therapy is popular, but the quantification of new bone is somewhat difficult with conventional evaluation method. To quantificate the amount of new bone, various evaluating methods have been introduced including histomorphometry, radiomorphometry, biochemical analysis, X-ray probe microanalysis, scanning electron microscope backscatter method. In this study, guided bone regeneration using resorbable membrane with & without PDGF-BB is quatificated through histomorphmetry to evaluate the efficacy of histomorphometric analysis. 4 beagle dogs and 8 Sprague-Dawley rats were selected as experimental animals. In beagle dog experiment, $4{\times}4mm$ Class II defects were created in maxillary both second premolars, and biodegradable membrane containing PDGF-BB(experimental group) were covered over one defect, and same membrane without PDGF-BB(control group) were covered over the other defect. At 2 weeks, 5 weeks after surgery, each beagle dogs were sacrificed, and the tissues were treated by undecalcified fixation. In Sprague-Dawley rat experiment, 5mm round defect were created in temporal bone, the same membranes were covered on the defects. At 1 week, 2 weeks after surgery, each rats were sacrificed, and undecalcified fixation were taken. After grinding tissue specimen, we analyse them histomorphometrically using image analysis system. In beagle dog 2 weeks specimens, new bone formation area were $0.03123mm^2$ in experimental group,and $0.03012mm^2$ in control group. At 5 weeks specimens, $0.15324mm^2$ in experimental group, and $0.09123mm^2$ in control group. In Sprague-Dawley rat specimens, new bone fomation area were $0.20448mm^2$ in 1 week experimental group, $0.03604mm^2$ in 1 week control group. At 2 weeks specimens, $0.46349mm^2$ in experimental group, $0.17741mm^2$ in control group. The results indicated that histomorphometric analysis of new bone formation using image analysis system is very effective quantification method to evaluate the efficacy of treatment modalities.

  • PDF

디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로 (Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation)

  • 진성진;임인철;조지환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.1-6
    • /
    • 2017
  • 흉부방사선 영상의 평가는 시각에 의한 사진평가가 가장 실용적이고 효과적인 방법으로 알려져 있다. 미국 방사선 안전국 규정 평가표(Bureau of Radiological Health, BRH)는 흉부방사선 영상의 해부학적 평가와 물리적 평가를 합하여 평가하는 효율적인 영상 평가방법이다. 본 연구는 여성 351명의 흉부방사선 영상을 체질량지수(Body Mass Index, BMI)와 허리둘레, 관전류량(mAs)과의 관계를 비교하고, 미국 방사선 안전국 규정 평가표를 사용하여 흉부 방사선 영상품질평가를 시행하였다. 대상자의 평균 연령은 $30.17{\pm}4.73$세이고, 허리둘레는 평균 $66.91{\pm}4.67cm$이었다. 체질량지수 값의 평균은 $20.21{\pm}2.23$으로 나타났으며, 전체 대상자의 관전류량 평균값은 $3.04{\pm}0.78$이고, 미국 방사선 안전국 규정 평균값은 $79.83{\pm}8.45$이었다. 허리둘레가 커질수록 관전류량 값이 증가함으로 나타났으며, 체질량지수가 커질수록 mAs값도 증가하였다. 연구대상자의 허리둘레, 관전류량, 미국 방사선 안전국 규정 값은 체질량지수 값이 커지면 허리둘레와 관전류량 평균값이 증가하였고, 미국 방사선 안전국 규정 값은 체질량지수가 높은 그룹이 낮은 그룹에 비하여 상대적으로 낮게 나타났으며, 통계적으로 유의하였다. 흉부검사 시 피검자의 신체두께나 체질량지수에 따라 자동노출제어 장치의 노출제어가 적절히 잘 이루어진 것으로 생각되며, 체질량지수가 증가할수록 신체두께가 커지고 또한 여성의 유방 두께도 증가하여 자동노출제어 장치에 의한 노출량이 변화되어 영상품질에 영향을 미치는 것으로 생각되어진다.

두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향 (Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images)

  • 정호걸;김기덕;박혁;김동욱;정해조;김희중;유선국;김용욱;박창서
    • Imaging Science in Dentistry
    • /
    • 제34권3호
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF