• Title/Summary/Keyword: X -ray Computed

Search Result 787, Processing Time 0.027 seconds

Design and Evaluation of the Tabletop Made of Carbon Fiber for X-ray CT Scanner (카본 섬유를 이용한 엑스선 CT 스캐너용 Tabletop의 설계 및 평가)

  • Sung, Kum-Gil;Park, Myung-Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.4
    • /
    • pp.195-199
    • /
    • 2008
  • The carbon fiber has low x-ray absorption property and high stiffness. This is the reason why many CT(Computed Tomography) manufacturer use carbon fiber in couch tabletop for CT scanner. In this paper, we design and make the couch tabletop made of carbon fiber composite, and verify the validity in CT scanner. In designing the couch tabletop, to determine the aluminum equivalent thickness of couch tabletop, we evaluate X-ray the transmissivity of aluminum and carbon plate in 80-120kVp X-ray energy range. And we perform structural analysis and mechanical design using determined thickness of carbon sheet. In conclusion, it was evaluated that manufactured couch tabletop satisfies X-ray transmissivity and mechanical requirements in CT scanner.

  • PDF

3D Inspection by Registration of CT and Dual X-ray Images

  • Kim, Youngjun;Kim, Wontae;Lee, Deukhee
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.1
    • /
    • pp.16-21
    • /
    • 2016
  • Computed tomography (CT) can completely digitize the interior and the exterior of nearly any object without any destruction. Generally, the resolution for industrial CT is below a few microns. The industrial CT scanning, however, has a limitation because it requires long measuring and processing time. Whereas, 2D X-ray imaging is fast. In this paper, we propose a novel concept of 3D non-destructive inspection technique using the advantages of both micro-CT and dual X-ray images. After registering the master object’s CT data and the sample objects’ dual X-ray images, 3D non-destructive inspection is possible by analyzing the matching results. Calculation for the registration is accelerated by parallel computing using graphics processing unit (GPU).

Study of Image Properties for Computed Radiography (Computed Radiography의 영상특성에 관한 연구)

  • Ryu, Ki-Hyun;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

Study of the Production Method of the Framework of Lacquerware Inlaid with Mother-of-pearl Using X-ray Computed Tomography (엑스선 컴퓨터 단층면 조사를 통한 나전연상 백골의 제작기법 연구)

  • Park, Youngman;Yang, Seokjin
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.75-80
    • /
    • 2020
  • X-ray computed tomography (X-ray CT), which is often applied to the investigation of the interior structures of cultural properties, is very useful for studying production methods used in lacquerware that would otherwise be difficult to observe with the naked eye. Lacquerware inlaid with mother-of-pearl is an important subject in the study of traditional Korean craft. However, it can be a challenge to specify the production methods used in the framework of a lacquerware item unless the object has been structurally damaged. Studies of lacquerware inlaid with mother-of-pearl have thus far focused on the techniques of lacquering and of inlaying the mother-of-pearl. Production methods for the framework of lacquerware has received little academic attention. This study conducted X-ray CT on a lacquerware item from the Joseon period to reveal the materials and woodworking techniques used for the framework. The study revealed that softwood was used for the framework, and the post (gidungmok) and apron (soemok) were joined using a three-way miter joint (sambang yeongwi jjaim). Other pieces were joined with nails.

Microfocus X-ray CT Analysis of Shrinking Direction in Resin Composite.

  • Inai, N.;Katahira, N.;Hashimoto, K.;Tagami, J.;Hirakimoto, A.;Marshall, S.J.;Marshall. G.W.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.559.1-559
    • /
    • 2001
  • The aim of the study was to determine the direction and the rate of polymerization shrinkage of light-cured resin composite. Materials and Methods: A microfocus x-ray CT(computed tomography) instrument (SMX-255CT, Shimadzu Co., Kyoto, Japan) was used to analyze and characterize the pre-and post-gel phases. A microfocus x-ray tube was used to enable a focus dimension of 4 microns.(omitted)

  • PDF

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

Physiologic Cervical Alignment Change between Cervical Spine X-ray and Computed Tomography

  • Lee, Ho Jin;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.784-790
    • /
    • 2021
  • Objective : The purpose of this study was to investigate the correlations among various radiological parameters used to determine cervical alignment from cervical spine radiographs (X-CS) and cervical spine computed tomography (CT-CS), both within and between modalities. Methods : This study included 168 patients (≤60 years old) without a definite whole spine deformity who underwent CT-CS and X-CS. We measured occipital slope (O-s), C1 slope, C2 slope, C7 slope, sella turcica - C7 sagittal vertical axis (StC7-SVA), spino-cranial angle, T1 slope, and C27-SVA. We calculated the O-C2 angle, O-C7 angle, and C2-7 angle from the measured parameters and conducted correlation analyses among multiple parameters. Results : The intrinsic correlation features among multiple cervical parameters were very similar for both X-CS and CT-CS. The two SVA parameters (C27-SVA and StC7-SVA) were mainly influenced by the upper cervical slope parameters (r=|0.13-0.74|) rather than the lower slope cervical parameters (r=|0.08-0.13|). The correlation between X-CS and CT-CS for each radiological parameter was statistically significant (r=0.26-0.44) except for O-s (r=0.10) and StC7-SVA (r=0.11). Conclusion : The correlation patterns within X-CS and CT-CS were very similar in this study. The correlation between X-ray and CT was statistically significant for most radiological parameters, and the correlation score increased when the horizontal gaze was consistently maintained. The lower cervical parameters were not statistically associated with translation-related parameters (C2-7 SVA and StC7-SVA). Therefore, the upper cervical segment may be a better predictor for determining head and neck translation.

A Study on the Diagnosis of Urinary Stone Location by Abdominal Positioning Variations (요로결석 위치 진단에 대한 복부자세 변화에 따른 연구)

  • Kim, Dong-Jin;Chae, Jong-Sang;Yoo, Chae-Min;Lee, Bae-Won
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.7-12
    • /
    • 2018
  • Patients who visit the emergency room with urinary stones have difficulty lying down in a supine position due to severe pain when performing the KUB test. The purpose of this study was to find methods to reduce the patients' pain and image distortion, and obtain medical images with high diagnostic values. After checking the standard classification of disease and cause of death, the target group consisted of 121 patients who had clearly distinguished stones from computed tomography. Patients with stones in the ureteralvesical junction were excluded. Qualitative image evaluation was performed by confirming the location of the stone in the computed tomography images. and evaluated the rate of visual discrimination of stones possible through KUB and abdominal plain X-ray. Quantitative image evaluation was performed on the KUB, abdominal plain X-ray images. The transverse process of the first lumbar vertebrae served as the standard point, and the length from this point to the lower part of the stone was measured. Results from looking at the rate of visual discrimination of stones possible through KUB and abdominal plain X-ray showed: 94 patients (77.6%) for KUB images and 91 patients (75.2%) for computed tomography images. The standard deviation for KUB and abdominal X-ray was 3 (2.4%). Comparing and analyzing the location from KUB images and abdominal plain X-ray images, the stone position was 10.1 mm in the kidney, 10.5 mm in the ureteropelvic junction, and 9.7 mm in the ureters. It was shown that the stone moved 10 mm on average with significant statistical difference (P<0.05). In cases where the pain is so severe that it is impossible to perform the test in the supine position, an alternative may be to check the stone position by performing a modified KUB test by having the patient stand in a vertical position. In the future, this will provide convenience to both the examiner and the patient when performing the examination, and it will contribute with its reproducibility.

Evaluation Method of Rock Characteristics using X-ray CT images (X-ray CT 이미지를 이용한 암석의 특성 평가 방안)

  • Kim, Kwang Yeom;Yun, Tae Sup
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.542-557
    • /
    • 2019
  • The behavior of rock mass is influenced by its microscopic feature of internal structure generating from forming and metamorphic process. This study investigated a new methodology for characterization of rock based on the X-ray CT (computed tomography) images reflecting the spatial distribution characteristics of internal constituent materials. The X-ray image based analysis is capable of quantification of heterogeneity and anisotropy of rock fabric, size distribution and shape parameter analysis of rock mineral grains, fluid flow simulation based on pore geometry image and roughness evaluation of unexposed joint surface which are hardly acquired by conventional rock testing methods.

Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species (Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1))

  • Song, Jung Il;Kim, Han Seul
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.220-231
    • /
    • 2021
  • The use of digital copies of film-based analog images and the introduction of digital radiographic imaging systems using image plates gradually replace the non-destructive radiationirradiation method of Cultural Heritage. The quality of images obtained from this technique is affected by conditions such as tube voltage, tube current, and exposure time, type of image acquisition medium, distance of the artifacts from the image acquisition medium, and thickness of artifacts. In this study, we evaluated the grayscale image obtained using GE's Computed Radiograhpy (CR) imaging system, the transmission characteristics of the X-ray source for each tree type (pine, chestnut, sawtooth oak, ginkgo) used in wooden Cultural Heritage, and the signal-to-noise ratio (SNR) and contrast. The GE's CR imaging were analyzed using the Duplex wire image quality indicator, line-pair gauges.