• Title/Summary/Keyword: X선 촬영

Search Result 287, Processing Time 0.033 seconds

Application of Incidence Angle on Lumbar Spine Anteroposterior General Radiography Image according to Measured Intervertebral Disc Angle (방사선 일반 정면검사에서 허리뼈 추간판 계측 값에 따른 입사각 적용)

  • Moon, Seul-Ji-A;Kim, Gyeong-Rip;Cho, Hee-Jung;Sung, Soon-Ki;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.6
    • /
    • pp.471-480
    • /
    • 2019
  • L-spine 3~4, L-spine 4~5, and L-spine 5~Sacrum 1 intervertebral disc(IVD) angle according to gender, age, body mass index(BMI), lumbar lordosis angle(LLA) were compared and analyzed. The anteriorposterior incidence angle of L-spine 3 ~ 4, L-spine 4 ~ 5 and L-spine 5~Sacrum 1 in body mass index were 5.66, 13.23 and 29.13 degrees in the head direction and L-spine 3 4, L-spine 4 ~ 5, L-spine 5~Sacrum 1 had 6.32 degrees, 16.09 degrees and 35.36 degrees in the head direction. The distortion area ratio comparison was performed with the phantom image using the proposed incidence angle. There was a significant difference in L-spine 4~5 and L-spine 5~Sacrum 1 IVD angle relative to body mass index and LLA(p<0.05), IVD angle and LLA were positively correlated(p<0.05).As a result of evaluating the usefulness of the image by applying the incidence angles of the disc angles according to the phantom angle of deviation to the head direction as 11 degrees for L4 and 26 degrees for L5, the distortion ratio area decreased from 14.90% to 12.11% in L4, And from 15.25% to 13.72% in L5. In anteriorposterior image of the Lumbar spine applying the incidence angle according to the measured disc angle, it is possible to reduce the distortion to purpose L4, L5. And improved the quality and diagnostic information of the target site.

The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems (디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구)

  • Kim, Kyo Tae;Kim, Kum Bae;Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.757-763
    • /
    • 2019
  • Recently, Following the recent development of flat panel detector with wide dynamic ranges, increasing numbers of healthcare providers have begun to use digital radiography. As a result, filter thickness standards should be reestablished, as current clinical practice requires the use of thicknesses recommended by the National Council on Radiation Protection and Measurements, which are based on information, acquired using conventional analog systems. Here we investigated the possibility of minimizing dose creep and optimizing patient dose using Al filters in digital radiography. The use of thicker Al filters resulted in a maximum 19.3% reduction in the entrance skin exposure dose when medical images with similar sharpness values were compared. However, resolution, which is a critical factor in imaging, had a significant change of 1.01 lp/mm. This change in resolution is thought to be due to the increased amount of scattered rays generated from the object due to the X-ray beam hardening effect. The increase in the number of scattered rays was verified using the scattering degradation factor. However, the FPD, which has recently been developed and is widely used in various areas, has greater response to radiation than analog devices and has a wide dynamic range. Therefore, the FPD is expected to maintain an appropriate level of resolution corresponding to the increase in the scattered-ray content ratio, which depends on filter thickness. Use of the FPD is also expected to minimize dose creep by reducing the exposure dose.

Nondestructive Analysis of Portrait of Master Gowun at Wunamyeongdang Shrine for Investigation of the Original Images and Pigments (비파괴 분석을 통한 최치원 진영(崔致遠 眞影)의 도상 및 채색재료 연구)

  • Choi, Hyunwook;Gwak, Hongin;Shin, Yongbi
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.81-98
    • /
    • 2020
  • This paper presents the results of a comprehensive nondestructive analysis of Portrait of Master Gowun at Wunamyeongdang Shrine (Hereafter, Portrait of Choe Chiwon), Tangible Cultural Heritage No. 187 of Gyeongsangnam-do, including the underlying images drawn at the time of its production and the pigments present. The analysis revealed that the portrait was produced in 1793 at Ssanggyesa Temple in Hadong, Gyeongsangnam-do, which makes it the earliest known example among the extant portraits of Choe Chiwon. X-ray examination found images of a half-length boy monk and a full-length boy monk on either side of the portrait, which had been painted over and became invisible to the naked eye. XRF analysis of the pigments indicated that white lead was used for white, cinnabar and red lead for red, malachite for green, azurite for blue, and gold for gold. It was revealed that the overpainted boy monks were colored using the same pigments as those applied in the portrait of the main figure. It is hoped that the analysis of the pigments used for the boy monks can provide basic materials for research on the production of copied portraits and local Buddhist paintings. Also, additional research drawing upon other fields of study is required to examine the details of the inscription of the portrait.

Comparison of Bone Ages in Early Puberty: Computerized Greulich-Pyle Based Bone Age vs. Sauvegrain Method (초기 사춘기의 골연령 비교: 전산화된 Greulich-Pyle 기반 골연령 대비 Sauvegrain 방법)

  • Sang Young Lee;Soo Ah Im
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1081-1089
    • /
    • 2022
  • Purpose To compare the computerized Greulich-Pyle based bone age with elbow bone age. Materials and Methods A total of 2126 patients (1525 girls; 601 boys) whose elbow bone age was within the evaluable range by the Sauvegrain method, and who simultaneously underwent hand radiography, were enrolled in the study. The 1st-bone age and VUNO score of the hand were evaluated using VUNOMed-BoneAge software. The correlation between the hand and elbow bone age was analyzed according to the child's gender and the probability of 1st-bone age. Results The correlation between VUNO score and elbow bone age (r = 0.898) was higher than the correlation between 1st-bone age and elbow bone age (r = 0.879). Moreover, the VUNO score showed a better correlation with the elbow bone age in patients with a 1st-bone age probability of less than 70%, or in girls. Elbow bone age was more advanced compared to hand bone age, and this difference increased until the middle of puberty and gradually decreased in the latter half. Conclusion The computerized Greulich-Pyle based hand bone age showed a significant correlation with the elbow bone age at puberty. However, since the elbow bone age tends to advance faster than the hand bone age, caution is required while judging the bone age during puberty.

An Experimental Method for the Scatter Correction of MV Images Using Scatter to Primary Ratios (SPRs) (산란선 대 일차선비(SPR)를 이용한 MV 영상의 산란 보정을 위한 실험적 방법)

  • Jeon, Hosang;Park, Dahl;Lee, Jayeong;Nam, Jiho;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun;Lee, Ju Hye;Kim, Dongwon
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.143-150
    • /
    • 2014
  • In general radiotherapy, mega-voltage (MV) x-ray images are widely used as the unique method to verify radio-therapeutic fields. But, the image quality of MV images is much lower than that of kilo-voltage x-ray images due to scatter interactions. Since 1990s, studies for the scatter correction have performed with digital-based MV imaging systems. In this study, a novel method for the scatter correction is suggested using scatter to primary ratio (SPR), instead of conventional methods such as digital image processing or scatter kernel calculations. We measured two MV images with and without a solid water phantom describing a patient body with given imaging conditions, and calculated un-attenuated ratios. Then, we obtained SPR distributions for the scatter correction. For experimental validation, a line-pair (LP) phantom using several Al bars and a clinical pelvis MV image was used. As the result, scatter signals of the LP phantom image were successfully reduced so that original density distribution of the phantom was restored. Moreover, image contrast values increased after SPR correction at all ROIs of the clinical image. The mean value of increases was 48%. The SPR correction method suggested in this study has high reliability because it is based on actually measured data. Also, this method can be easily adopted in clinics without additional cost. We expected that the SPR correction can be an effective method to improve the quality of MV image guided radiotherapy.

Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques (조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가)

  • Nam, Ji-Ho;Ki, Yong-Kan;Kim, Dong-Won;Kim, Won-Taek
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The aim of this study is to evaluate and compare the incidence and aspects of myocardial perfusion defects in patients who were subjected to either two-dimensional or three-dimensional simulation techniques for early left-sided breast cancer. The myocardial perfusion defects were determined from using single photon emitted computerized tomography (SPECT) myocardial perfusion images. $\underline{Materials\;and\;Methods}$: Between January 2002 and August 2003, 32 patients were enrolled in this study. The patients were diagnosed as having early (AJCC stage T1-T2N0M0) left-sided breast cancer and were treated with tangential irradiation after breast-conserving surgery and systemic chemotherapy. The patients were divided into two groups according to the type of simulation received: two-dimensional simulation using an X-ray fluoroscope simulator or three-dimensional simulation with a CT simulator. All patients underwent technetium-99m-sestamibi gated perfusion SPECT at least 3 years after radiotherapy. The incidence and area of myocardial perfusion defects were evaluated and were compared in the two groups, and at the same time left ventricular ejection fraction and cardiac wall motion were also analyzed. The cardiac volume included in the radiation fields was calculated and evaluated to check for a correlation between the amount of irradiated cardiac volume and aspects of myocardial perfusion defects. $\underline{Results}$: A myocardial perfusion defect was detected in 11 of 32 patients (34.4%). There were 7 (46.7%) perfusion defect cases in 15 patients who underwent the two-dimensional simulation technique and 4 (23.5%) patients with perfusion defects in the three-dimensional simulation group (p=0.0312). In 10 of 11 patients who had myocardial perfusion changes, the perfusion defects were observed in the cardiac apex. The left ventricular ejection fraction was within the normal range and cardiac wall motion was normal in all patients. The irradiated cardiac volume of patients in the three-dimensional simulation group was less than that of patients who received the two-dimensional simulation technique, but there was no statistical significance as compared to the incidence of perfusion defects. $\underline{Conclusion}$: Radiotherapy with a CT simulator (three-dimensional simulation technique) for early left-sided breast cancer may reduce the size of the irradiated cardiac volume and the incidence of myocardial perfusion defects. Further investigation and a longer follow-up duration are needed to analyze the relationship between myocardial perfusion defects and clinical ischemic heart disease.

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Positive Rate of Tumor Marker according to Sites of Recurrence in Gastric Cancer (위암 재발부위에 따른 종양표지자의 양성률)

  • Jang, Jin-Seok;Lee, Sung-Wook;Lee, Jong-Hun;Roh, Myung-Hwan;Han, Sang-Young;Kim, Min-Chan;Jeong, Gap-Jung;Choi, Seok-Reyol
    • Journal of Gastric Cancer
    • /
    • v.5 no.4 s.20
    • /
    • pp.222-227
    • /
    • 2005
  • Purpose: There are several reports suggested the usefulness of serum tumor markers, AFP, CEA and CA19-9 as prognostic factors or indicators for recurrence in gastric cancer. This clinical study was peformed to evaluate positive rate of tumor markers according to site of recurrence in gastric cancer. Materials and Methods: From the database of patients who underwent radical gastrectomy for gastric cancer between January 1999 and January 2004, 52 patients who showed recurrence were included in this retrospective study. Serum levels of tumor markers were measured at the time of preoperative diagnosis of the gastric cancer and at the time of postoperative recurrence during follow up, respectively. Results: The overall positivity of tumor markers at the time of recurrence was found to be significantly higher than that of prior to surgery in the recurred group for the single test as well as the combination tests. For the peritoneum, the most common recurrent site, the positivity of CA19-9 was higher at the time of recurrence. And the significant positivity of CEA at the time of recurrence was detected in the liver cases. Conclusion: Having a preoperative positive tumor marker may identify the patient as having an increased chance of a recurrence. Although tumor markers continue to have limited diagnostic significance in gastric cancer, CA19-9 may be useful as a predictor for peritoneal recurrence of the gastric cancer, and CEA for recurrence to liver.

  • PDF

Early and Late Bowel Complication Following Irradiation of Cancer of the Uterine Cervix (자궁경부암의 고선량 치료후의 장관 합병증)

  • Kim Myung Se;Kim Kyung Ae;Kim Sung Kyu;Shin Sei One;Lee Sung Ho;Chang Jae Chun
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.59-70
    • /
    • 1989
  • Cervix cancer is the most common female cancer in Korea. In spite of their relatively local invasive tendency, still $44\%$ of patient will develop recurrent cancer. This result suggests that more aggressive local treatment may increase the cure rate but increased complication risk also cannot be avoidable. Various institutions proposed different treatment regimen, but recommended dose were about 4500 cGy for whole pelvis and 8000 cGy at point A, even though they agreed that those doses may not be satisfactory for control of bulky disease. 96 cases of invasive cervical cancer, treated with postoperative or primary radiation therapy were analyzed to determine the complication rate and prognostic factor in our treatment regimen Which is $5500\~1000 CGy$ higher than Other institution. Mean follow up duration was 21 months. Symptomatic patients including mild but persistent abdominal discomfort was $46\%$, but only 1 patient $(1\%)$ had operative treatment because of incomplete obstruction of small bowel. Most symptoms appeared within 12 months and most common complaints were frequent bowel movement. Barium enema and sigmoidoscopy were performed for persistent symptomatic patients. Only one patient had abnormal finding in barium enema which showed inefficiency of this method for detecting bowel complication. Patient's age, total tumor dose, total TDF, rectal dose were not significant risk factors for complication, but boost dose, previous history of operation had some relationship with complication risk. Even though dose of point A and rectum is $500\~1,000cGy$ higher than other institution, such a low rate of severe complications may suggest that fear of complications should not be overestimated than cure rate and the possibility of more aggressive treatment for better local control should not be underestimated.

  • PDF

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.