• Title/Summary/Keyword: X선

Search Result 1,669, Processing Time 0.028 seconds

Radiation Effect on Electrical Conduction of Insulating oil (절연유의 전기전도 현상에 미치는 방사선 영향)

  • 김영일;이덕출;정연택
    • Electrical & Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.235-242
    • /
    • 1988
  • 본 논문에서는 X선장치용 절연유의 X선 조사에 의한 전기전도 현상을 이해하기 위해서 X선량(1.2*$10^{4}$R), 인가시간, 분위기(공기, N$_{2}$가스, 진공), 전계 등의 특성과 전극 재료와 갭길이 의존성을 시료의 온도 30-100.deg.C 범위에서 도전전류를 측정하였다. 도전전류는 X선 미조사 절연유 보다는 저온 및 저전계 영역의 조사된 절연유에서 증가되었으나 고온과 고전계 영역에서는 구별되지 않았다. 이들 결과는 저온 및 저전계에서는 X선 조사에 의한 해리 및 이온화 작용에 의해 하전항체가 증가되고 있음을 생각할 수 있으며 X선장치 설계 및 취급 관리에 있어 적당한 자료로 제시할 수가 있겠다.

  • PDF

Survey on microcalorimetry about EDS (에너지 분산형 미세열량측정에 관한 자료조사)

  • Kim, J.H.;Park, K.S.;Oh, C.S.
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • We have surveyed on microcalorimetry which we can treat with energy dispersive spectrometer(EDS) as wavelength dispersive spectrometer(WDS), to be developed in order to make higher energy resolution as to detect X-ray peak as high as wavelength dispersive spectrometer(WDS). When we take into consideration about energy resolution, Wavelength dispersive spectrometer is 2~20eV and energy dispersive spectrometer is 140~180eV.

Fuzzy Cluster Based Diagnosis System for Digital Mammogram (퍼지 클러스터 기반 디지털 유방 X선 영상 진단 시스템)

  • Rhee, Hyun-Sook;Yoon, Seok-Min
    • The KIPS Transactions:PartB
    • /
    • v.16B no.2
    • /
    • pp.165-172
    • /
    • 2009
  • According to the American Cancer Society, breast cancer is the second largest cause of cancer deaths and most frequently diagnosed cancer in women. The currently most popular method for early detection of breast cancer is the digital mammography. A mass or calcification lesion has been known as the most important clue for the diagnosis. In this paper, we propose a diagnosis approach based on fuzzy cluster knowledge base. We combine different two sources of feature data in duel OFUN-NET and produce the diagnosis result with possibility degree. We also present the experimental results on the dataset of mass and calcification lesions extracted from the public real world mammogram database DDSM. These results show higher classification accuracy than conventional methods and the feasibility as a decision supporting tool for diagnosis of digital mammogram.

Diagnostic Value of Thoracography in Pneumothorax (기흉에서 흉강조영술(Thoracography)의 진단적 가치)

  • 박영식;한재열;장지원
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.730-734
    • /
    • 1998
  • Background: It is important to know the location, number, size and shape of bullae before thoracotomy or VATS bullectomy. Chest X-ray and chest CT may be used but with some limitation. The purpose of this study was to compare the diagnostic value of thoracography with that of chest X-ray in preoperative detection of bullae. Meterial and Method: Thoracography was performed by injection of non-ionic water-soluble dye into pleural space in 22 primary spontaneous pneumothoraces, which underwent thoracotomy or VATS bullectomy. Chest X-ray and thoracography were compared through operative finding. Results: Sensitivity and accuracy of thoracography(75% and 72.7%) were higher than those of chest X-ray(30% and 36.4%). However, specificity of thoracography(50%) was lower than that of chest X-ray (100%). There were no complications during or after thoracography. Conclusion: Thoracography is a safer and more useful method for preoperative detection of bullae when compared with chest X-ray.

  • PDF

Feasibility study of insertable miniature x-ray source for dental imaging (치과 영상용 삽입형 초소형 X선 튜브의 가능성 연구)

  • Cho, Sung-Ho;Kim, So-Yeong;An, So-Hyun;Lim, Soo-Mee;Lee, Re-Na
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Conventional periphery radiography system has a various problem such as patient dose and the pain of X-ray examination. In this paper, to solve these problems, we suggested insertional miniature x-ray system and we verified the feasibility of this system. First, we performed the Geant4 x-ray simulation to design x-ray collimator and filter to use miniature x-ray tube and we decided optimized thickness of filter and collimator. Also, we measured x-ray spectrum using CdTe detector and PX4 module to verify simulation results. Also, we acquired teeth image of fabricated phantom using conventional dental x-ray and prosed miniature x-ray system. As a results, our system has good image quality as compared to those of conventional systems. Our evaluation of the proposed system indicates that it can be potentially very useful for dental imaging.

Medical Clinics' quality Management of X-ray Units in Gyeongbuk Area (경북 지역 의원급의 X선 발생장치 정도관리 실태)

  • Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.267-275
    • /
    • 2010
  • Quality management of an x-ray unit drastically differs according to the type of establishment of medical institutions. Many primary medical institutions have it, but they do not pay much attention to quality management. In the study, Gyeongbuk area has been divided into four zones from January 4, 2010 to September 3, 2010, and four places were designated by city. Among medical institutions located at a total of 16 sites, the target was 8 places with X-ray emission equipment 10 years or more in use as well as 8 places with X-ray emission equipment less than 10 years in use. The 5 essential items of quality control were tested. In the test that checked for equipment it was found that sites with X-ray emission equipment 10 years or more in use didn't have ground connection (6.25%) while all of them passed the current leak test. In the exposure dose reproducibility test 4 sites with X-ray emission equipment 10 years or more in use (25%) and 1 site with X-ray emission equipment less than 10 years in use didn't pass the test. In the KVp accuracy test 5 sites with X-ray emission equipment 10 years or more in use (31.25%) and 2 sites with X-ray emission equipment less than 10 years in use (12.5%) didn't pass the test. In the tube current and tube current amount test 3 sites with X-ray emission equipment 10 years or more in use (18.75%) and 1 site with less than 10 years in use (6.25%) didn't pass the test. According to the findings of the present research, quality control at medical institutions with X-ray equipment 10 years or more in use was poorer than medical institutions with X-ray equipment less than 10 years in use. In this regard, administrative and technical measures need to be taken as soon as possible. In addition, owners of medical clinics or unit managers need to raise awareness, and it is necessary to revise a regular test cycle every year or every two years if they have old equipment or if the equipment is not used on a frequent basis. And it is also important to provide regular educational programs for quality management.

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

The mechanism of chondrogenesis inhibition by X-Irradiation (X선에 의한 연골세포 분화 억제 작용경로)

  • Ha, Jong-Yeol;Lim, Young-Bin;Lee, Yoon-Ae;Sonn, Jong-Kyung;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.91-97
    • /
    • 2003
  • The purpose of this study is to investigate the mechanism of inhibition of chondrogenic differentiation by X-irradiation. Cultures of chick limb bud mesenchymal cells were exposed to various dose of X-ray and chondrogenesis was examined. X-irradiation inhibited accumulation of proteoglycan based on the observation of alcian blue staining and expression of chondorcyte specific-type II collagen. X-irradiation also inhibited expression of protein kinase $C{\alpha}$ while expression of $PKC{\lambda}({\iota}),\;{\varepsilon}$ was not altered. Expression of Erk-1 was not changed by X-irradiation but phosphorylation of Erk-1 was increased. In addition, inhibition of Erk-1 phosphorylation by PD98059 overcame inhibitory effect of X-irradiation on the chondrogenic differentiation. PNA staining data showed that X-irradiation inhibited cellular aggregation. Taken together, these results suggest that X-irradiation inhibits chondrogenic differentiation by inhibiting cellular aggregation and suppressing expression of $PKC{\alpha}$ and promoting phosphorylation of Erk-1. In addition to above pathway, our results also suggest that X-irradiation may exerts its inhibitory effect by another signaling pathways.

  • PDF

How to Improve Image Quality for the Chest PA and the Simple Abdomen X-ray Examinations (흉, 복부 단순 X-ray 검사 시 영상의 질 향상 방법)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • The purpose of this study is to examine how much the movement at X-ray examinations like breathing or the positioning affects the image during chest or abdomen X-ray examination so as to create an image containing information as much as possible. The study method adopted is doing the X-ray in each of the states including breathing (inspiration & expiration) and movement in the standing chest PA X-ray and simple abdomen X-ray among the kinds of examination selected the most in hospitals and then evaluating them by applying the standards of image evaluation for each region. According to the study result, about the standing chest PA X-ray, the images taken at inspiration contain more information than those taken at expiration or having subtle movement during the examination. About the simple abdomen X-ray, the images taken at expiration contain more information than those taken at inspiration or movement. The above study results imply that regarding general X-ray examination, information we can find from the images may differ significantly according to the region examined, examination purpose, or movement during the examination like breathing.