• Title/Summary/Keyword: X선

Search Result 1,674, Processing Time 0.035 seconds

Efficacy of Pamidronate in Nephropathic Children with Ongoing Long Term Corticosteroid Therapy (장기 스테로이드 치료요법 중인 신질환 환자에서 Pamidronate의 효과)

  • Hong Hyun-Kee;Kim Eun-Seong;Kim Sung-Do;Cho Byoung-Soo
    • Childhood Kidney Diseases
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2004
  • Background : Steroid-induced osteoporosis(SIO) is one of the serious complications of long-term steroid therapy, especially in growing children. Recently bisphosphonates have been used to treat or prevent SIO in adult, which is rare in children with glomerular diseases. We studied the effect of pamidronate on SIO using dual energy X-ray absorptiometry and biochemical markers of bone turnover. Methods : Forty four children receiving moderate-to-high doses of steroids were enrolled. They had no history of bone, liver, or endocrine disease. Patients were stratified by their baseline bone mineral density(BMD) findings. All patients received corticosteroids for 3 month and oral calcium supplementation(500 mg/day) daily. Among them, 28 patients were treated with placebo and 16 were treated with pamidronate(125 mg) for 3 months. Blood chemistry and bone mineral density(BMD) were measured at baseline, and 3months. In addition, parathyroid hormone(PTH), serum osteocalcin, and urinary dipyridinoline levels were evaluated. Results : In overall population, the mean lumbar spine BMD decreased from $0.754{\pm}0.211(g/cm^2)$ to $0.728{\pm}0.208(g/cm^2)$ in the placebo group(P<0.05) and increased from $0.652{\pm}0.194(g/cm^2)$ to $0.658{\pm}0.226(g/cm^2)$ in the pamidronate group(P>0.05). Conclusion : Pamidronate appears to be effective in preventing SIO in children with glomerular diseases requiring long-term steroids therapy. Further careful observation and follow-up might be needed for children receiving bisphosphonates such as pamidronate.

  • PDF

The Position for Measuring BMD of the Distal Radius and The Study of the Correlation Between the Distal Radius and Lumba (원위 요골 골밀도의 측정 자세 및 요추 골밀도의 상관관계에 관한 연구)

  • Han, Man-Seok;Jeon, Chul-Min;Kim, Jong-Jin;Seo, Seon-Youl;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The aim of this study was to evaluate the change of bone mineral density according to distal radius rotation and the correlations of the lowest BMD measured by DXA at the lumba versus distal radius. The eleven males were projected distal radius by DR X-ray and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 21 males. The healthy 11 and 21 volunteers without any history of operations, anomalies, or trauma were enrolled. The experiment was performed by two methods. First, The DR X-ray was measured distal radius of 11 males in pronation and supination with three, six and nine degrees, including a neutral position. The ROI was measured by the m-view program on the PACS monitor. Second, The DXA was measured distal radius of 21 males in pronation and supination with five and ten degrees, including a neutral position to evaluate the changes of BMD according to the rotation. A correlation of the BMD in the distal radius with BMD that lumbar spine was performed, along with analysis of the data by SPSS 12.0v. The mean rotation angle of the distal radius about eleven males DR X-ray measured $7^{\circ}$ of pronation (82%, n = 9), $6^{\circ}$ of supination and $0^{\circ}$ of neutral of (9%, n = 1), The total average rotation angle in 11 male was $5.1^{\circ}$ of pronation. The rotation angle of the distal radius about twenty one males on DXA measured $7.2^{\circ}$ of pronation (43%, n = 9), $7^{\circ}$ of supination (24%, n = 5), and $0^{\circ}$ of neutral (33%, n = 7), The total average rotation angle in 21 people was $4.1^{\circ}$ of pronation. The correlation of the analysis of lumba and distal radius were r = 3.0, p = 0.18. consequently, The correlation was not significance. Because BMD of lumba was not coverd for BMD of the distal radius, with a neutral position, Pronation is needed for BMD in the distal radius with the rotation angle measuring at the lowest BMD. the rotation angle about five degrees of pronation of the distal radius is recommended.

The Bone Mineral Density Impact Factors of Adult Women before the Menopause - based on the National Health and Nutrition Examination Survey - (폐경 전 성인여성의 골밀도 영향 요인 - 국민건강영양조사 자료를 이용하여 -)

  • Kim, Kyung-Hee;Lee, Jung-Hee;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.147-168
    • /
    • 2015
  • In this research, we have analyzed the impact factors on the bone mineral density thru the examination of bone density difference in the entire femur, femoral neck and lumbar of adult women before the menopause in accordance with the general features, lifestyle, eating habits, health and body composition. The survey was conducted among adult women before the menopause and older than 30 years based on the data of the National Health and Nutrition Examination Survey carried out in the 4th term (2008-2009) and 5th term (2010-2011) and we would like to provide the research results for the establishment of recommendations or guidelines for the treatment of adult women before the menopause with regard to the impact factors on the bone mineral density and for the development of health education materials for the accurate measurement of bone mineral density of young women in order to prevent the postmenopausal osteoporosis. With respect to the general features of adult women before the menopause, the bone mineral density was higher in the entire femur at age 40-44, femoral neck at 35-39, in high-school education level, in the earlier menarche group, without smoking experiences, with regular walking time and exercise frequency and with the habits of eating no hamburger or pizza. With regard to the body composition, the bone mineral density was higher in obesity and lower in underweight cases, higher among people with abdominal obesity and weight control experiences. In terms of total body fat ratio, total amount of fat and muscle, the bone mineral density got gradually increased from the 1st quarter (Q1) to the 4th quarter(Q4). The obesity, disease, total amount of fat and muscle were shown to be significantly related with the bone mineral density in this research and it is required for young women to keep the adequate weight and the normal BMI in order to increase the bone mineral density. For the prevention of osteoporosis, it is advised to keep the right habits including regular exercise and no smoking discipline from the growing period and achieve the maximum bone mass thru the control of proper weight from a young age.

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.

Hydrothermal Synthesis of Kaolinite and Change of Its Properties (캐올리나이트의 수열합성 및 특성변화)

  • Jang, Young-Nam;Ryu, Gyoung-Won;Chae, Soo-Chun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.241-248
    • /
    • 2009
  • Kaolinite was synthesized from amorphous $SiO_2$ and $Al(OH)_3{\cdot}xH_{2}O$ as starting materials by hydrothermal reaction conducted at $250^{\circ}C$ and $30\;kg/cm^2$. The acidity of the solution was adjusted at pH 2. The synthesized kaolinite was characterized by XRD, IR, NMR, FE-SEM, TEM and EDS to clarify the formational process according to the reaction time from 2 to 36 hours. X-ray diffraction patterns showed after 2 h of reaction time, the starting material amorphous $Al(OH)_3{\cdot}xH_{2}O$ transformed to boehmite (AlOOH) and after the reaction time 5 h, the peaks of boehmite were observed to be absent thereby indicating the crystal structure is partially destructed. Kaolinite formation was identified in the product obtained after 10 h of reaction and the peak intensity of kaolinite increased further with reaction time. The results of TGA and DTA revealed that the principal feature of kaolinite trace are well resolved. TGA results showed 13 wt% amount of weight loss and DTA analysis showed that exothermic peak of boehmite observed at $258^{\circ}C$ was decreased gradually and after 10 h of reaction time, it was disappeared. After 5 h of the reaction time, the exothermicpeak of transformation to spinel phase was observed and the peak intensiy increased with reaction time. The results of FT-IR suggested a highly ordered kaolinite was obtained after 36 hours of reaction. It was identified by the characteristic hydroxide group bands positioned at 3,696, 3670, 3653 and $3620\;cm^{-1}$. The development of the hydroxyl stretching between 3696 and $3620\;cm^{-1}$, depends on the degree of order and crystalline perfection. TEM results showed that after 15 h reaction time, curved platy kaolinite was observed as growing of (001) plane and after 36 h, the morphology of synthetic kaolinite exhibited platy crystal with partial polygonal outlines.

CO2 Sequestration and Utilization of Calcium-extracted Slag Using Air-cooled Blast Furnace Slag and Convert Slag (괴재 및 전로슬래그를 이용한 CO2 저감 및 칼슘 추출 후 슬래그 활용)

  • Yoo, Yeongsuk;Choi, Hongbeom;Bang, Jun-Hwan;Chae, Soochun;Kim, Ji-Whan;Kim, Jin-Man;Lee, Seung-Woo
    • Applied Chemistry for Engineering
    • /
    • v.28 no.1
    • /
    • pp.101-111
    • /
    • 2017
  • Mineral carbonation is a technology in which carbonates are synthesized from minerals including serpentine and olivine, and industrial wastes such as slag and cement, of which all contain calcium or magnesium when reacted with carbon dioxide. This study aims to develop the mineral carbonation technology for commercialization, which can reduce environmental burden and process cost through the reduction of carbon dioxide using steel slag and the slag reuse after calcium extraction. Calcium extraction was conducted using NH4Cl solution for air-cooled slag and convert slag, and ${\geq}98%$ purity calcium carbonate was synthesized by reaction with calcium-extracted solution and carbon dioxide. And we conducted experimentally to minimize the quantity of by-product, the slag residue after calcium extraction, which has occupied large amount of weight ratio (about 80-90%) at the point of mineral carbonation process using slag. The slag residue was used to replace silica sand in the manufacture of cement panel, and physical properties including compressive strength and flexible strength of panel using the slag residue and normal cement panel, respectively, were analyzed. The calcium concentration in extraction solution was analyzed by inductively coupled plasma optical emission spectrometer (ICP-OES). Field-emission scanning electron microscope (FE-SEM) was also used to identify the surface morphology of calcium carbonate, and XRD was used to analyze the crystallinity and the quantitative analysis of calcium carbonate. In addition, the cement panel evaluation was carried out according to KS L ISO 679, and the compressive strength and flexural strength of the panels were measured.

A Study on the Peripheral Dose of 6MV X-ray Beam (6 MV X선의 주변선량분포)

  • Choi, Doo-Ho;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.24-33
    • /
    • 1989
  • The peripheral dose, defined as the dose outside therapeutic photon fields, was estimated for 6MV X-ray linear accelerator. The measurements were performed using silicon diode detectors controlled by automatic controlled water phantom. The effects of field size, collimator position, presence or absence of wedge filter, and wedge angle were analyzed. The results were as follows 1. The peripheral dose decreases as the distance from field margin increases and it is more than 2.4% of central axis maximum dose even at 15cm distance from field margin. 2. Maximum build-up of peripheral dose is at 2-3 mm from the water surface and drops to a minimum at 1.5cm depth and then the dose increase again. 3. The peripheral dose increases as the field size. increases. At the short distance from field margin, the difference of peripheral dose between 5 $\times\;5cm^2$ and 20 $\times\;20cm^2$ field size reaches more than 2 fold. 4. The peripheral dose is higher along the upper collimator than along the lower collimator. The differences is less than 1%. 5. The presence of wedge filter increases peripheral dose. And the peripheral dose is higher along the blade side of wedge filter than along the ridge side. The difference is about 3% at 5cm distance from the field margin for 15 $\times\;15cm^2$ field size and 60$^{\circ}$ wedge filter. 6. The Peripheral dose of wedge filter increases as the wedge filter angle increases and the increasing ratio is about 2 fold in 60$^{\circ}$wedge filter compared with open field.

  • PDF

XRF Analysis and Polarizing Microscopic Study of the Lava Cave Formation, Korea, Japan and Russia (한국, 일본, 러시아 용암동굴 형성층의 형광X선 분석과 편광현미경적 연구)

  • Sawa, Isao;Furuyama, Katsuhiko;Ohashi, Tsuyoshi;Kim, Chang-Sik;Kashima, Naruhiko
    • Journal of the Speleological Society of Korea
    • /
    • no.74
    • /
    • pp.23-31
    • /
    • 2006
  • (1) Kaeusetgul Cave in Kimnyong-Ri, Jeju-Do, Korea. Kaeuset-gul Cave (KC) is situated in NNE area of the Manjang-gul cave (125m a.s.l.). Kaeuset-gul Cave lies at $126^{\circ}45'22"$ E in longitude and $33^{\circ}33'09"$ N in latitude. The coast belong Kimnyeong-Ri, Kujwa-eup, Jeju-Do. Altitude of the cave-entrance is 10m and length of the cave is 90m. Lava hand-specimens of KC are studied by X-ray fluorescence analysis (XRF). Average major chemical components of specimens from KC is as follows (wt.%); $SiO_2=47.03$, $TiO_2=3.16$, $Al_2O_3=18.41$, FeO*=13.53, MnO=0.14, MgO=5.05, CaO=8.66, $Na_2O=2.81$, $K_2O=0.67$, $P_2O_5=0.55$ in KC. Polarizing microscopic studyindicates that these specimens are described of alkali-basalt. (2) Tachibori Fuketsu (Cave) in Shizuoka Prefecture, Fuji Volcano, Japan Tachibori Fuketsu lies attoward the south in skirt of the Fuji volcano, $138^{\circ}42'04"$ east longitude and $35^{\circ}18'00"$ north latitude. The location of cave entrance is 2745, Awakura, Fujinomiya-shi, Shizuoka Prefecture. The above sea level and length of Tachibori Fuketsu are 1,170m and 82m. Average major chemical components of specimens from cave areas follows (Total 100 wt.%) ; ($SiO_2$=50.52, $TiO_2$=1.69, $Al_2O_3$=15.47, FeO*=13.13, MnO=0.20, MgO=5.97, CaO=9.17, $Na_2O$=2.52, $K_2O$=0.94 and $P_2O_5=0.40).$ Polarizing microscopic study indicates that these specimens may belong to tholeiite-basalt series. According to polarizing microscopic study, Au (Augite), P1 (Plagioclase), and O1 (Olivine) are contained as phenocryst minerals. (3) Gorely Cave in Kamchatka Peninsula, Russia Gorely caldera is located at the southeastern part of Kamchatka Peninsula, about 75km southwest of Petropavlovsk-Kamchatskiy.. Gorely lava caves are situated in NHE area of Mt. Gorely volcano (1829m a.s.1.). One of lava cave (Go-9612=K-1) lies at $158^{\circ}00'22"$ east longitude and $52^{\circ}36'18"$ north latitude. The elevation of cave entrance is about 990m a.s.1. and the main cave extends in the NNW direction for about 50m by 15m wide and 5m in depth. The cave of K-3is near the K-1 cave. "@Lava hand-specimens K-1 and K-3 caves are studied by X-ray fluorescence analysis and polarizing microscopic observation. Average major chemical components of specimens from these caves are as follows (wt.%) ;($SiO_2$=55.12, $TiO_2$=1.25, $Al_2O_3$=16.07, T-FeO* =9.41, MnO=0.16, MgO=5.01, CaO=7.21, $Na_2O$=3.39, $K_2O$=1.92, $P_2O_5$=0.45) and these values indicate that the Gorely basaltic andesite belong to high alumina basalt. Polarizing microscopic study indicates that these specimens are described of Augite andesite.

The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR) (Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교)

  • Kim, Jin-Bae;Kang, Chung-Hwan;Kang, Sung-Jin;Park, Soo-In;Park, Jong-Won;Kim, Yeong-Su;Kim, Seung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.64-77
    • /
    • 2002
  • DR has had an important fact not only in the department of radiology but also in productivity or work efficiency of a whole hospital. The environment of DR has more various parameter than CR, so it is able to supply high quality of medical services. The current environment of radiology department in each hospital has been changed from Film-Screen system to DR through Full-PACS. This hospital which uses Full-PACS became to study the proper condition of CR and DDR and how the image quality of them is expressed among general photographing systems in the DR environment. From this experiment, the image quality of DDR is better than CR under the same exposure condition. And in the DDR system, the score of image which uses AEC is a little higher than the score which doesn't use it. Especially it can be known that the function of AEC of DDR is useful to improve the image quality in the part of skull and chest. (The function of AEC : It is the tool that detects the ionized current of x-ray which goes through objects with using the ion chamber which is in the detector. Also it controls the examination of X-ray when the proper density is reached.) Because the proper degree of density can be represented by this system, the photographing can be taken much easily without consideration of the exposure condition with the thickness of various objects. From the result of this experiment, it can be known that the selection of proper exposure condition plays an important rule to gain good Image Quality. More researches will be necessary about DDR system which has potential ability in the future.

  • PDF

Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws (고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구)

  • Kim Jeung-kee;Choi Young-Min;Lee Hyung-Sik;Hur Won-Joo
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 1996
  • Purpose : The accurate dosimetry of independent collimator equipped for 6MV and 15MV X-ray beam was investigated to search for the optimal correction factor. Materials and Methods : The field size factors, beam quality and dose distribution were measured by using 6MV, 15MV X-ray Field size factors were measured from $3{\times}3cm^2$ to $35{\times}35cm^2$ by using 0.6cc ion chamber (NE 2571) at Dmax. Beam qualities were measured at different field sizes, off-axis distances and depths. Isodose distributions at different off-axis distance using $10\times10cm^2$ field were also investigated and compared with symmetric field. Result: 1) Relative field size factors was different along lateral distance with maximum changes in $3.1\%$ for 6MV and $5\%$ for 15MV. But the field size factors of asymmetric fields were identical to the modified central-axis values in symmetric field, which corrected by off-axis ratio at Dmax. 2) The HVL and PDD was decreased by increasing off-axis distance. PDD was also decreased by increasing depth For field size more than $5{\times}cm^2$ and depth less than 15cm, PDD of asymmetric field differs from that of symmetric one ($0.5\~2\%$ for 6MV and $0.4\~1.4\%$ for 15MV). 3) The measured isodose curves demonstrate divergence effects and reduced doses adjacent to the edge close to the flattening filter center was also observed. Conclusion . When asymmetric collimator is used, calculation of MU must be corrected with off-axis and PDD with a caution of underdose in central axis.

  • PDF