• 제목/요약/키워드: X선조사야

검색결과 478건 처리시간 0.027초

X선조사(線照射)에 의한 절연유(絶緣油)의 도전특성(導電特性)에 관한 연구(硏究) (A Study on Conductivity Characteristics of X-ray Irradiated Insulating Oil)

  • 김영일;이덕출;정연택
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.75-83
    • /
    • 1987
  • The insulating oil used for X-ray tube housing were degraded by X-ray irrdiation, high temperature and high anode voltage for normal operation. This study was measured the conduction current-X-ray dose, heating degradation, time, temperature and electric field characteristics and the dependense of electrode materials and gap length in the X-ray irradiatied insulating oil under of D.C voltage. The obtained results can be summarized as following. 1. The conduction current of X-ray irradiated insulating oil is more about $2.5{\sim}3$ times as large as than that of non x-ray irradiated, and is become saturation phenomena after some degree. 2. The conduction current of many times heating x-ray irradiated insulating oil is more than that of a few times heating. 3. The higher temperature x-ray irradiated insulating oil is increased, the more conduction current, and that is increased about ten times as large as when it's temperatures is increased to $80^{\circ}C\;at\;30^{\circ}C$, twenty five times at $100^{\circ}C$. 4. The dependence of electrode materials is appeared at the low electric field, and the small gap length with Fe > Cu > Al. 5. The low electric field than 3000 v/cm is appeared Ohm's law region, and the high is become saturation region at the I-E characteristics. 6. The larger gap length is become, the more conduction current is increased at the same electric field.

  • PDF

MA법에 의한 V-Co계 비정질합금의 제조 및 구조분석 (Fabrication and structural observation of amorphous V-Co alloy by mechanical alloying)

  • 이충효
    • 한국결정성장학회지
    • /
    • 제22권1호
    • /
    • pp.51-56
    • /
    • 2012
  • 본 연구에서는 출발원료로 ${\sigma}$-VCo 금속간화합물과 $V_{50}Co_{50}$ 혼합분말을 각각 사용하여 기계적 합금화에 따른 비정질화 가능성을 조사하였다. X선 회절에 의해 얻어진 전구조인자 S(Q) 및 동경분포함수 RDF(r)의 결과로부터 볼밀링이 진행됨에 따라 비정질상의 구조적 특징이 분명히 관찰되었다. 120시간 MA 처리에 의하여 두 경우 모두에서 비정질상이 생성됨을 알 수 있었다. 60시간 동안 MA 처리한 $V_{50}Co_{50}$ 분말시료의 열분석 에서는 약 $600^{\circ}C$에 비정질상의 결정화에 의한 발열 peak가 관찰되었다. X선 회절법에 의해 얻어진 전구조인자 및 동경분포함수의 분석으로부터 MA 시간에 따라 출발 결정상은 비정질상의 특징적인 원자구조로 서서히 변화함을 알 수 있었다.

입자침전법을 이용한 다결정 산화수은과 산화납 필름의 방사선 유방촬영 장치 적용성 평가 (The Evaluation of the Thick Polycrystalline HgO and PbO Films Derived by Particle Sedimentation Method for the Mammographic Application)

  • 노시철;박지군;최일홍;정형진;강상식;정봉재
    • 한국방사선학회논문지
    • /
    • 제8권7호
    • /
    • pp.429-433
    • /
    • 2014
  • 본 연구에서는 입자 침전법으로 제작된 HgO와 PbO 기반 영상 센서의 유방촬영 영역에서의 적용 가능성을 조사하였다. 이를 위하여, 다양한 두께에 따른 HgO와 PbO 필름의 물리적 특성과 x선에 대한 양자 효율을 측정하였으며, 몬테카를로 시뮬레이션 결과와 비교 평가하였다. 또한, 입자 침강법을 이용하여 인듐 주석 산화물로 코팅 된 투명 유리기판 위에 대면적 다결정 박막을 제작하였다. 본 연구에서는 단결정의 효율과 비슷한 양자 효율을 얻기 위하여 필름의 두께와 제작 조건을 변화시켜 최적화 하였다. 본 연구의 결과를 기반으로 차후 대면적 a-Si:H 패널에 적합한 대면적 필름의 제작 기술과 최적화 연구가 가능할 것으로 판단된다.

형광체기반 Application에서 페를린 증착 유무에 따른 광학적 농도 변화에 대한 연구

  • 김교태;홍주연;김진선;허예지;신정욱;허승욱;박지군;남상희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.397.1-397.1
    • /
    • 2014
  • 최근 방사선 진단 영역에 이용되고 있는 증감지는 입사된 방사선의 감도를 증가시키기 위해 형광체를 사용하고 있으며, 외부의 에너지를 흡수하여 빛으로 방출하는 역할을 한다. 이는 방사선 검출기, 디스플레이, 의료기기 등 다양한 분야에 활용되고 있다. 필름에 X선을 노출 할 경우 형광체의 사용 유무에 따라 방사선 흡수 효율에 영향을 미치며, 이는 발광 효율 및 감도에 주요한 인자로 작용한다. 현재 상용화되어 있는 형광체는 낮은 발광 효율로 인한 한계를 가지므로, 발광 효율 향상을 위하여 제작 구조에 대한 연구가 진행되고 있다. 이 중 반사막을 활용하는 연구가 활발히 진행되고 있다. 일반적으로 형광체의 제조를 위하여 보편적으로 이용하고 있는 스크린프린팅 방법에서 건조 공정을 수행 시 균일도가 감소하는 현상이 발생한다. 이러한 현상은 반사막의 증착을 불균일하게 만드는 원인으로 작용하고 빛의 산란을 초래하는 현상을 초래한다. 이에 본 연구에서는 증착 시 투명도 저하에 따라 반사율이 증가되는 반사막 성질을 가지며, 방수성 및 절연성과 같은 보호층 특성을 지닌 유기성 투명 박막 페를린에 대하여 연구하고자 한다. 본 연구에서는 화학적 증기 증착법(Chemical Vapor Deposition, CVD)을 이용하여 투명 필름의 상단에 페를린을 코팅한 시편과 코팅하지 않은 시편으로 구분하여 제작하였고, 상단에 스크핀프린팅 방법을 활용하여 형광체를 도포 하였다. 시편 제작 후 실험은 시편을 필름 상단에 위치시키고, 일반진단에너지 대역(Model-SF 80)의 X선을 조사하였다. 이 후 현상기(model-pro14)를 통해 현상된 필름에 나타난 광학적 농도(Optical Density, O.D)를 농도계(Fluke Biomedical Nuclear Associates Densitometer)로 측정하였는데, 불확실성을 줄이기 위하여 총 5회를 측정하여 그 중 2번째로 높은 값을 도출하였다. 측정 결과, 페를린을 코팅한 형광체에서는 1.71의 O.D 값이 측정되었고, 페를린을 코팅하지 않은 형광체에서는 1.43의 O.D 값이 측정되었다. 이를 이용하여 투명도를 산출한 결과 상대적으로 약 1.76% 차이가 나타났다. 이러한 결과는 페를린 활용 시 환자의 피폭 선량 저감화 및 해상력 개선을 도모할 수 있을 것으로 사료된다.

  • PDF

문 개폐 여부와 차폐체 설치 유무에 따른 공간산란선량 측정 : X선 촬영 시 피폭선량 감소방안에 대한 연구 (Measurement of the Spatial Scattering Dose by Opening, Closing Door and Installing Shielding : A Study on the Reduction of Exposure Dose in Radiography)

  • 윤홍주;이용기;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.477-482
    • /
    • 2019
  • Recently, due to the increased use of medical radiation, the radiation exposure of radiation workers should be considered as well as medical exposure of patients. And it is recommended to close the door during radiography. however, In this study, when the door was inevitably opened for radiography, the proposed method was to install the shield as a method of reducing the exposure dose. And its efficiency was analyzed. In simple chest radiography, the measurement point was changed according to the measurement location. Dose rate were measured 10 times for each condition using a dosimeter. And the average value was derived. Using this, the change of dose according to the opening and closing of the door and the installation of the shield was analyzed. Using this, we compared and analyzed the dose change according to the door opening and closing and the installation of the shield, and significance was verified through the SPSS ver. 24. Depending on whether the door was opened or closed, 11,215.35%, 159.0%, 101.9% increased in front of the door in the consol room, behind the wall and behind the lead glass. Depending on the installing of the shield, the 49.2%, 29.6%, 19.9%, 30.6% decrease in front of the door in the examination and consol room, behind the wall and lead glass. In addition, statistical analysis was showed that there were significant differences in both the results according to whether the door was opened or closed and shielding(p<.05). Close the door during radiography. However, when the door should be opened, it was confirmed that the dose rate were reduced by installing the shield. Therefore, to optimize radiation protection, it is recommended to install shields when opening the door.

이온교환된 X형 및 Y형 제올라이트의 O1S 전자에 대한 X선 광전자분광학적 해석 (XPS Studies for O1S Electrons of Ion Exchanged Zeolite X and Y)

  • 김명철;김종택
    • 공업화학
    • /
    • 제3권2호
    • /
    • pp.240-246
    • /
    • 1992
  • X선 광전자분광법을 이용하여 교환된 제올라이트내 산소원자의 전자구조를 조사하였다. $Na^+$, $Fe^{2+}$$Fe^{3+}$로 교환된 X형 및 Y형 제올라이트에 대하여 얻어진 $O_{1S}$스펙트럼은 골격산소의 결합에너지를 밝히기 위하여 분해하였다. 각 스펙트럼에서는 2-3개의 분해띠들이 있었다. 분해된 각 띠들의 특성은 교환된 양이온에 따라서 $O_{1S}$ 전자의 결합에너지와 띠면적의 관점에서 고찰되었다. 분해된 띠들을 각각 골격내 가교산소에 의한 것(띠 1), 양이온에 결합된 산소에 의한 것(띠 2), 양이온에 배위된 물분자내 산소에 의한 것(띠 3)으로 해석되었다. $O_{1S}$스펙트럼 면적의 대부분을 차지하고 있는 띠 1은 제올라이트내 Al함량의 감소에 따라서 결합에너지상의 증가를 나타내었다.

  • PDF

비수계 용매를 사용하는 마이크로파 환원법에 의한 서브마이크론 니켈 분말의 합성 (Preparation of Submicron Nickel Powders with Non-aqueous Solvent In Microwave-Assisted Reduction Method)

  • 전승엽;김재환;박나이;박효열;이근대;홍성수;박성수
    • 공업화학
    • /
    • 제18권4호
    • /
    • pp.320-325
    • /
    • 2007
  • 본 연구에서는 재래식 및 마이크로파 합성법을 통하여 비수계 유기용매인 diethanolamine을 용매로 하여 초산니켈 수용액과 히드라진 수화물로부터 니켈 분말을 합성하였다. X선 회절분석, 주사 전자현미경 분석, 열분석 및 X선 광전자 분광기 분석등을 통하여 마이크로파의 비열적 효과 및 반응 조건이 니켈분말의 합성에 미치는 영향을 조사하였다. 재래식 합성과 비교해보면, 마이크로파를 이용한 합성에서 마이크로파의 비열적 효과에 기인하여 상대적으로 응집이 적게 일어나고, 입자 크기는 작고, 입도 분포는 균일하였다.

CsI(T1) 방사선센서의 제작 및 분광특성 연구 (A Study on the Fabrication of CsI(T1) Radiation Sensor and its Spectroscopic Characteristics)

  • 권수일;신동호
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.44-50
    • /
    • 2002
  • 실험실에서 성장시킨 CsI(T1)섬광체를 이용하여 검출기를 설계 제작하고 분광 및 출력특성을 조사하여 핵분광과 진단방사선센서로서의 응용가능성을 타진해 보았다. CsI(T1)단결정은 수직 Bridgman성장장치를 이용하여 지름 11mm, 몰농도 0.001mo1%로 성장시키었다. 이 단결정을 광다이오드를 이용하여 방사선 센서로 제작한 후, $^{22}$ Na, /up 137/Cs, $^{30}$ Co 표준감마선원에 대한 에너지 분해능을 각각 측정하였으며 진단 X선 영역에 대한 출력특성도 측정하였다. $^{22}$ Na의 0.511 MeV 의 경우13.2%, $^{137}$Cs의 0.662 MeV의 경우 8.3%, 그리고 $^{60}$Co의 1.17 MeV와 1.332 MeV에 대해서는 각각 6.7%와 5.1%의 에너지 분해능을 얻었다. 또한 관전압 60kVp, 80kVp, 100kVp, 120kVp 에 대하여 5mAs부터 80mAs 까지 진단 X선영역에 대한 출력 선형성을 확인하였다.

  • PDF

In Vitro X선조사(線照射)가 가토폐포표면(家兎肺胞表面) 활성물질(活性物質)에 미치는 영향(影響) (Effect of X-Irradiation in Vitro on the Pulmonary Surfactant in Rabbits)

  • 조중환;주영은
    • The Korean Journal of Physiology
    • /
    • 제5권1호
    • /
    • pp.51-58
    • /
    • 1971
  • In an attempt to further clarify the effect of X·irradiation on the activity of surfactant in rabbits, X-ray in dose of 900r was irradiated to the lung tissues of rabbits in vitro. Tension-area diagram of the lung extract was recorded automatically by a modified Langmuir-Wilhelmy balance with a synchronized recording system designed in this department. The surface tension of the lung extract was measured at 1,3,5,24 and 48 hours post-irradiation, and the results were compared with the non·irradiated normal group. The result$ thus obtained are summarized as follows: I The maximal surface tension, minimal surface tension, width of the tension·area diagram at the surface area of 40% in the lung extract and stability index of the normal rabbit long extract were 40.73 dynes/cm, 8.96 dynes/cm, 20.71 dynes/cm and 1.28, respectively. II. When 900r of X-ray was irradiated to the lung in vitro, 1) The maximal and minimal surface tensions did not differ noticeably from the normal at 1,3, and 5 post-irradiation hours, but the minimal surface tension increased significantly at 24 and 48 hours Post-irradiation. 2) The width of the tension area at the surface area of 40% showed a tendency of decrease throughout the experiment. 3) The stability index showed no significant change at 1,3 and 5 post-irradiation hours,but at 24 and 48 hours post-irradiation a significant decrease was observed comparing with the control. III. Activity of surfactant was significantly depressed by X·irradiation in vitro especially at 24 and 48 hours post-irradiation.

  • PDF

CD-RAD Phantom을 이용한 의료영상의 분석 (Analysis of Medical Image with CD-RAD Phantom)

  • 김창복;김영근;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.369-369
    • /
    • 2007
  • 본 연구에서는 CD-RAD Phantom을 이용하여 의료영상의 명세성 (image clarity)분석을 위하여 동일한 X선 영상을 대상으로 물리적 평가와 시각적 평가를 비교분석 하였다. 측정방법은 CD-RAD Phantom을 X선 조사하여 CR 영상처리장치를 통해 영상을 획득하였으며, 영상분석은 CD-RAD analyser program을 통한 통계학적 방법으로 물리적 평가를 시행하고, 동일한 영상의 시각적 평가는 관찰자 20명을 대상으로 blind test를 시행하였다. 분석결과는 Contrast-detail curve의 물리적 평가 IQF값은 25, 시각적 평가 IQF값은 30으로 분석되어 물리적 평가가 시각적 평가에 비해 우수하게 나타났다. 의료영상의 특성은 영상 판독자에게 영상의 정보 전달능력이 매우 중요하므로 객관적인 물리적 분석법과 시각적 분석법이 병행되어야 한다고 판단된다.

  • PDF