• Title/Summary/Keyword: X선조사야

Search Result 478, Processing Time 0.029 seconds

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.

Monte Carlo Simulation for absorbed dose in PMMA phantom during the low-energy X-ray irradiation (저 에너지 X선 조사 시 PMMA 팬텀 내의 흡수선량 평가를 위한 몬테카를로 시뮬레이션)

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.383-389
    • /
    • 2011
  • This study offered a new method to calculate absorbed dose of actual patients through Monte Carlo Simulation by using the linkage of Geant4 and DICOM, and, the experimental value of absorbed dose at the center and Geant 4 simulation result according to the depth of PMMA mock phantom were compared by using MOSEF in order to verify Geant4 calculation code. In the area where there was no air space between the irregular gap due to incomplete compression of PMMA slab, the differences were $0.46{\pm}4.69$ percent and $-0.75{\pm}5.19$percent in $15{\times}15cm^2$ and $20{\times}20cm^2$ respectively. Excluding the error due to incomplete compression of PMMA mock phantom, the calculation values of the Monte Carlo simulation by linkage of Geant4 and DICOM was the same.

Effect of Low Temperature Annealing on the Magnetoresistance in Co/Cu Artificial Superlattice (Co/Cu인공초격자에서 저온 열처리가 자기저항에 미치는 영향)

  • 민경익;송용진;이후산;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.4
    • /
    • pp.305-309
    • /
    • 1993
  • Thermal stability of Co/Cu artificial superlattice (AS) prepared by RF-magnetron sputtering and the effect of low temperature annealing on the magnetoresistance of the AS have been investigated in this work. Dependence of annealing behavior on the Cu spacer thickness, Fe underlayer thickness, and kind of the underlayer was examined and the relationship between the interfacial reaction and magnetoresistance was studied. It turned out that when Co/Cu AS was annealed at low temperature ($<450^{\circ}C$), the magnetoresistance could increase in the case of AS with thick spacer Cu ($20~25\AA$) layer, whereas it decreased in the case of AS with thin spacer Cu ($7\AA$) layer, which of the former is in contrast with previous reports and the latter in consistent with them. The increase of magnetoresistance is due to increase of interfacial atomic sharpness, which is supported by low angle X-ray diffraction analysis. The thermal stability of Co/Cu AS was better in the case of thick Fe underlayered AS. Interfacial reaction (separation of intermixed Co and Cu) could be observed at lower temperature for (200)-textured samples than for (111)-textured samples, which can be interpreted in terms of interdiffusion kinetics depending on the crystallographic orientation.

  • PDF

Preliminary Study for Development of Low Dose Radiation Shielding Material Using Liquid Silicon and Metalic Compound (액상 실리콘과 금속화합물을 융합한 저선량 방사선 차폐 소재 개발을 위한 사전연구)

  • Jang, Seo Goo;Han, Su Chul;Kang, Sung Jin;Lim, sung wook;Lee, Sung Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.461-468
    • /
    • 2017
  • This study measured and compared the protective clothing using Pb used for shielding in a diagnostic X-ray energy range, and the shielding rates of X-ray fusion shielding materials using Si and $TiO_2$. For the experiment, a pad type shielding with a thickness of 1 mm was prepared by mixing $Si-TiO_2$, and the X-ray shielding rate was compared with 0.5 mmPb plate of The shielding rate of shielding of 0.5 mmPb plate 95.92%, 85.26 % based on the case of no shielding under each 60 kVp, 100 kVp tube voltage condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 11 mm or more, and the shielding rate of 100% or more was confirmed at a thickness of 13 mm in 60 kVp condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 17 mm or more, and a shielding rate of 0.5 mmPb plate was observed at a thickness of 23 mm in 100 kVp condition. Through the results of this study, We could confirm the possibility of manufacturing radiation protective materials that does not contain lead hazard using various metalic compound and liquid Si. This study shows that possibility of liquid Si and other metalic compound can harmonize easily. Beside, It is flexible and strong to physical stress than Pb obtained radiation protective closthes. But additional studies are needed to increase the shielding rate and reduce the weight.

Crystallographical Characteristics of Solar Salts Produced from Jeonnam Area by X-Ray Diffraction Technique (X선 회절법에 의한 전남지역 천일염의 결정학적 특성)

  • Jeong, Byung-Jo;Kim, Yong;Kim, Chang-Dae;Hyun, Seung-Cheol;Ham, Gyung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1284-1288
    • /
    • 2009
  • Identification of various inorganic compound crystals contained in solar salts, which are produced from 12 areas of Jeonnam, was firstly made by the X-ray diffraction (XRD) technique. The analysis of the XRD spectra was carried out on the basis of Joint Committee on Powder Diffraction Standards (JCPDS) data and the results of Energy Dispersive X-ray Spectrometer (EDX) measurements. In particular, the analysis of the XRD spectra supported that each solar salt contains $Na_2S$ (Shinan Jeungdo and Sinui), $KMgCl_3$ (Shinan Bigeum), $Ca(ClO_3)_2$ (Shinan Docho), $CaAl_4O_7$ (Haenam Songji), $CaSiO_3$ and $CaCl_2$ (Goheung) as inorganic compound crystals, which have not been reported for the solar salts. Also, the XRD results indicated that the solar salts maintain a cubic NaCl crystal structure without any change of lattice parameters etc. However, it was shown in the Field Emission Scanning Electron Microscope (FE-SEM) images that an external form of the solar salts has a lamination layer shape of a cubic structure, which is different from a simple cubic form for the purified salts and the reagent NaCl.

Chest Radiographs and CT Findings during Healthcare Workers' Tuberculosis Screening Using Interferon- Gamma Release Assay: Retrospective Observational Study (인터페론-감마 분비 검사를 이용한 의료 종사자의 결핵 스크리닝에서 흉부 X선 사진 및 CT 소견: 후향적 관찰 연구)

  • Ye Ra Choi;Jung-Kyu Lee;Eun Young Heo;Deog Kyeom Kim;Kwang Nam Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1524-1533
    • /
    • 2021
  • Purpose To investigate the incidence of tuberculosis (TB) in healthcare workers (HCWs) with positive interferon-gamma release assay (IGRA) results based on chest X-ray (CXR) and CT findings and determine the role of imaging in the diagnosis of TB. Materials and Methods Among 1976 hospital personnel screened for TB using IGRA, IGRApositive subjects were retrospectively investigated. Clustered nodular and/or linear streaky opacities in the upper lung zone were considered positive on CXR. The CT findings were classified as active, indeterminate, inactive, or normal. The active or indeterminate class was considered CT-positive. Results IGRA was positive in 255 subjects (12.9%). CXR and CT were performed in 249 (99.2%) and 113 subjects (45.0%), respectively. CXR- and CT-positive findings were found in 7 of 249 (2.8%) and 9 of 113 (8.0%) patients, respectively. Among the nine CT-positive subjects, active and indeterminate TB findings were found in 6 (5.3%) and 3 (2.7%) patients, respectively. Microbiological tests, including acid-fast bacilli staining, culture, and polymerase chain reaction for TB, were negative in all nine CT-positive subjects. Empirical anti-TB medications were administered to 9 CT-positive subjects, and 3 of these nine subjects were CXR-negative for pulmonary TB.

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.

Crystallization Behavior of Poly(ethylene terephthalate)/Ethylene-Methyl acrylate-Glycidyl methacrylate Copolymer Blend (폴리에틸렌테레프탈레이트/에틸렌-메틸아크릴레이트-글리시딜 메타크릴레이트 공중합물 블렌드의 결정화 거동)

  • 성상엽;이종관;이광희;진병석
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.848-854
    • /
    • 2001
  • The crystallization behavior of poly (ethylene terephthalate) (PET) /ethylene-methyl acrylate-glycidyl methacrylate copolymer (E-MeA-GMA) blend was studied. The extent of reaction and the reaction rate between PET and E-MeA-GMA were measured with torque rheometer, FT-IR and SEM. The effects of the grafting reaction on the crystallization behavior were investigated with DSC and time-resolved light scattering (TR-LS) techniques. The morphological change at the lamellar level was also examined by using a small angle X-ray scattering (SAXS) method.

  • PDF

Optical characteristics of Nd:LSB microchip laser device (Nd:LSB 마이크로칩 레이저 광소자의 광학 특성)

  • Jang, Won-Kweon;Park, Jong-Seon;Kim, Tong-Yol;Yu, Young-Moon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.965-967
    • /
    • 2003
  • Czochralski pulling method에 의해 성장된 고농도 도핑 Nd:LSB의 광학적 특성을 조사하였다. 결정 성장조건에 의해 달라지는 space group은 지금까지 C2/c, R32, Cc와 C2등 4가지가 보고되었으며, 기본적으로 6방정계의 구조를 가지고 비선형 광학 결정으로서의 특성을 보였다. x선 회절 분석계를 이용하여 구조를 분석하였고, 도핑 농도에 따른 형광 수명의 변화, 분산곡선 특성을 조사하였다. 또한 흡수 및 저온 형광 스펙트럼을 이용하여 도핑 농도 및 space group의 변화에 따른 에너지 준위의 변화를 관찰하고 비교하였다.

  • PDF

Study of the Al Alloy Surface with Fe Alloy Zincate Treatment (Fe합금 징케이트 처리한 알루미늄 합금 표면분석2)

  • Kim, Yu-Sang;U, Ji-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.166.2-166.2
    • /
    • 2016
  • 알루미늄 합금 표면의 도금피막 밀착성을 향상시키는 전처리 방법으로는 아연 치환법[이하; 징케이트(Zincate)처리]이 사용되고 있다. 2중 징케이트 처리에 의해 아연 치환층이 치밀화 하여, 아연 치환층의 일부가 알루미늄과 합금화 한다. 일본에서는 2중 징케이트 처리의 각 과정에 있어서 알루미늄 합금의 표면 상태를 X선 광전자분광장치(XPS)로 조사하였다. 본고에서는 Fe합금 징케이트 처리의 각 공정에 있어서 알루미늄 합금 표면을 XPS로 조사한 결과, 징케이트 처리에 기초한 피막의 구조와 밀착성 개선효과에 관하여 기술하였다.

  • PDF