• 제목/요약/키워드: Wrapping Method

검색결과 149건 처리시간 0.025초

반복적인 위상 랩핑 방법을 이용한 실질적인 암호화 및 복호화 시스템 (Practical Encryption and Decryption System using Iterative Phase Wrapping Method)

  • 서동환;이성근;김윤식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.955-963
    • /
    • 2008
  • In this paper, we propose an improved practical encryption and fault-tolerance decryption method using a non-negative value key and random function obtained with a white noise by using iterative phase wrapping method. A phase wrapping operating key, which is generated by the product of arbitrary random phase images and an original phase image. is zero-padded and Fourier transformed. Fourier operating key is then obtained by taking the real-valued data from this Fourier transformed image. Also the random phase wrapping operating key is made from these arbitrary random phase images and the same iterative phase wrapping method. We obtain a Fourier random operating key through the same method in the encryption process. For practical transmission of encryption and decryption keys via Internet, these keys should be intensity maps with non-negative values. The encryption key and the decryption key to meet this requirement are generated by the addition of the absolute of its minimum value to each of Fourier keys, respectively. The decryption based on 2-f setup with spatial filter is simply performed by the inverse Fourier transform of the multiplication between the encryption key and the decryption key and also can be used as a current spatial light modulator technology by phase encoding of the non-negative values. Computer simulations show the validity of the encryption method and the robust decryption system in the proposed technique.

오버레이용접된 Wrapping Roll의 비드마크제거를 위한 열영향부의 미세조직에 관한 연구 (The Study on Microstructure of the Heat Affected Zone for Removing of Beadmark in the Overlayered Wrapping Roll)

  • 유국종;백응률
    • Journal of Welding and Joining
    • /
    • 제18권6호
    • /
    • pp.68-73
    • /
    • 2000
  • In case of overalyered wrapping roll, beadmark shape appear at wrapping roll surface due to irregular wear between weld bead. Irregular wear of this is caused by difference of hardness between weld bead. This study aims at investigating which matrix is good for removing of beadmark at wrapping roll surface. So, we make specimen with martensitic matrix and austenitic matrix. The overlayered alloys were deposited 4 times on a SS41 steel plate using self-shielding flux cored arc welding method. Difference of hardness between weld bead of specimen with matrix of martensite was higher than specimen with matrix of austenite both as-welded and after heat treatment. Therefore, austenitic matrix is between than martensitic matrix for removing of beadmark of wrapping roll surface.

  • PDF

수도용 강관의 도복장 재료특성 평가에 관한 연구 (Evaluation of the Properties of Wrapping Material of Steel Pipe for Water Supply)

  • 이현동;이지은;곽필재
    • 대한환경공학회지
    • /
    • 제30권3호
    • /
    • pp.331-338
    • /
    • 2008
  • 본 연구에서는 국내에서의 생산되는 강관의 도복장 재료 및 방법별로 관체 시편을 이용하여 도복장강관의 성능을 시험하였다. 도복장강관의 원관의 물성 및 화학조성의 분석결과 모두 기준에 적합하였다. 강관의 도복장 재료의 물성시험 결과, 블론아스팔트와 콜타르에나멜은 비용이 저렴하고 기계적 성질은 매우 우수하나, 유기용매에 녹는 단점을 지니고 있고, 도복장강관이 도복장재료로서 성능이 떨어지는 것으로 나타났다. 또한 두껍게 도복할 경우, 강관 자체의 하중이 필요 이상으로 높아지는 문제가 발생할 수 있다. 당김강도 시험과 음극박리 시험결과, PE-3층 도복장방식이 우수하였으며, PE의 도복장방법에 따라서는 압출식(T-Die) 3층 폴리에틸렌(PE 3-Layer)이 분말용착식 폴리에틸렌(PE Fluidized)보다 당김강도가 강하며 음극박리 면적도 작았다. 압출식(T-Die) 3층 폴리에틸렌(PE 3-Layer)은 기계적 특성, 열적 특성 모두 우수하였고, 내화학성도 뛰어났다. 액상에폭시는 수지 선정과 경화 조건에 따라서 도장재의 특성을 변화시킬 수 있다. 본 시험에서 사용된 폴리우레탄은 강관과의 접착력도 에폭시에 비하여 낮았으며, 수분 흡수율은 에폭시 보다 높은 결과를 나타내었다. 폴리우레탄을 도복장재료로 사용하기 위해서는 우레탄의 기본물성과 최적의 도장조건을 도출하는 연구가 진행되어야 할 것으로 판단된다. 본 연구에서 실험한 시편 중에서는 현재 압출식으로 제조한 PE-3층 도복장방법이 가장 우수한 것으로 평가되었지만, 앞으로 기타 다른 도복장재료와의 추가 검증시험이 필요할 것으로 판단된다.

육성용접된 Wrapping Roll의 비드마크제거를 위한 미세조직 (The Microstructure For Removing of Beadmark of Hardfacing Wrapping Roll)

  • 유국종;백응률
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2000년도 특별강연 및 추계학술발표대회 개요집
    • /
    • pp.216-218
    • /
    • 2000
  • In case of hardfaced wrapping roll, beadmark shape appear at wrapping roll surface due to irregular wear between weld bead. Irregular wear of this is caused by difference of hardness between weld bead. This study aims at investigating which matrix is good for removing of beadmark at wrapping roll surface. So, we make specimen with martensitic matrix and austenitic matrix. The hardfacing alloys were deposited 4 times on a SS41 steel plate using self-shielding flux cored arc welding method. Difference of hardness between weld bead of specimen with matrix of martensite was higher than specimen with matrix of austenite both as-welded and after heat treatment. Therefore, austenitic matrix is better than martensitic matrix for removing of beadmark of wrapping roll surface.

  • PDF

포장술을 시행한 뇌동맥류의 치료 성적 (Treatment Results of Intracranial Aneurysms by Wrapping and Coating)

  • 권택현;정흥섭;박윤관;조태형;임동준;박정율;정용구;이훈갑;이기찬;서중근
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권7호
    • /
    • pp.891-895
    • /
    • 2001
  • Objective : Although surgical clipping of intracranial aneurysm is the definite method of treatment, there remains a small number of patients in whom surgical clipping is not technically possible. In such difficult cases, surgeon has to consider other therapeutic alternatives. In this report, we analyze our aneurysmal cases treated by wrapping and coating method and evaluate their surgical outcome and follow-up results. Method : Among the total of 877 patients operated from 1990 to 1999 for intracranial aneurysms at our hospital, 40 cases(4.6%) were treated by wrapping and coating method. They included 24 cases of single ruptured aneurysms and 16 with unruptured ones in multiple aneurysms. Wrapping with temporalis muscle and/or muslin gauze and coating with bioadhesive agent such as fibrin glue were performed. Result : Wrapping and coating method was performed mostly to the anterior communicating artery aneurysm (35%), and mostly because of the broad-based neck of an aneurysm(43%). At the time of discharge, 30 out of 40 patients(80%) showed favourable outcome and three cases died. The patients were monitored for average of 37 months(3-75 months). Among 24 cases with single ruptured aneurysm, 4 cases(17%) had early rebleeding within 6 months from the initial hemorrhage, and such rebleeding occurred within the first postoperative month in 3 cases. However, there was no rebleeding after the 6 months. Among 16 patients whose aneurysms were unruptured ones, none of them showed bleeding episode. Conclusion : It seems likely that the wrapping and coating method would be some help to prevent the rebleeding of an intracranial aneurysm. In order to obtain more accurate results regarding the efficacy of such method, it will be necessary to perform a multi-center study for longer follow-up periods and various wrapping and coating materials.

  • PDF

수술 후 발생한 족근관 증후군의 자가 복재 정맥 이식술을 이용한 치료 (Treatment of Postoperative Tarsal Tunnel Syndrome with Autogeneous Vein Wrapping Graft)

  • 김재영;박현규;이경태;양기원;정주선
    • 대한족부족관절학회지
    • /
    • 제10권1호
    • /
    • pp.109-112
    • /
    • 2006
  • Management of postoperative tarsal tunnel syndrome is a perplexing problem to the surgeons. Autogenous vein wrapping graft is a effective method to decompress the tarsal tunnel. We treated 2 cases of postoperative tarsal tunnel syndrome with autogenous saphenous vein wrapping graft technique, and could get good results. Autogenous vein wrapping graft seems to be a good technique for tarsal tunnel syndrome with severe adhesion, particularly after surgery, and postoperative nerve adhesion can be prevented.

  • PDF

인발성형 FRP의 Wrapping에 의한 기계적 특성 (Mechanical Properties of Pultruded FRP rod with Wrapping)

  • 박효열;강동필;한동희;안명상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1530-1532
    • /
    • 2000
  • The properties of FRP usually depends on the fabricating method. The fiber orientation of FRP is also depends on the fabricating method. The fiber orientation in FRP has a great effect on the strength of FRP because the strength of FRP mainly depends on the strength of fiber. In this study. compressive and bending strength of FRP rods were investigated. Inner part of FRP was made unidirectionally by pultrusion method and outer part of FRP was made by wrapping method. The size effect was also investigated with pultruded FRP rods.

  • PDF

특징 래핑을 통한 숫자형 특징과 범주형 특징이 혼합된 데이터의 클래스 분류 성능 향상 기법 (Improving Classification Performance for Data with Numeric and Categorical Attributes Using Feature Wrapping)

  • 이재성;김대원
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권12호
    • /
    • pp.1024-1027
    • /
    • 2009
  • 본 논문에서는 혼합형 데이터에 대한 특징 선별 기법의 효율성을 비교하기 위해 특징 필터링과 특징 래핑을 통한 특징 선별 후, 클래스 분류 성능을 측정하였다. 혼합형 데이터는 숫자형 특징과 범주형 특징이 함께 혼합되어 있으므로, 숫자형 특징을 범주형 특징으로 이산화를 하여 단일형 데이터로 변환한 뒤 특징 선별 기법 등을 적용할 수 있다. 본 연구에서는 혼합형 데이터를 전처리하여 단일형 데이터로 변환하고, 널리 활용되는 특징 필터링 기법과 특징 래핑 기법을 통해 클래스 분류 성능을 높일 수 있는 특징 집합을 선별하였다. 선별된 특징 집합을 통한 클래스 분류 성능을 비교한 결과, 특징 필터링에 비해 특징 래핑을 통해 선별한 특징 집합을 활용하여 클래스 분류를 하였을 때 분류 정확도가 높은 것을 확인할 수 있었다.

조각보의 조형성을 응용한 현대복식디자인 개발에 관한 연구 (A Study on Developing the Modern Fashion Design with the Application of Plasticity of Patchwork Wrapping Cloth)

  • 김정미
    • 한국의류학회지
    • /
    • 제30권4호
    • /
    • pp.507-518
    • /
    • 2006
  • This study aims to prove that traditional patchwork wrapping cloth can be a creative motive for modem fashion, and the application of it can be a way of expressing not only the pride in our cultural heritage but also the originality of fashion design. The analysis of the plasticity of 108 patchwork wrapping clothes has come up with the following findings: Firstly, the plane structure consists of 41 basic forms and 67 applied ones. Secondly, 61 contrast color harmony and 47 similarity color harmony. Thirdly, the fabric consists of 88 silk clothes, 19 ramie clothes, and 1 silk and ramie cloth. Fourthly, 47 unlined clothes and 61 lined ones. The study also expresses the analyzed plasticity of patchwork wrapping cloth for fashion with the following findings: Firstly, basic plane structures, contrast color harmony, silk cloth and the press flower coating technique become one piece dress to express splendid and elegant image. Secondly, application plane structures, similarity color harmony of natural dyeing method using persimmon, ramie cloth and the press flower coating and over lock technique become a jacket and a blouse to express calm and dynamic image. Thirdly, the needling and over lock technique used to patch clothes has become a desirable way to express fabric with unique surface effects. Fourthly, the press flower coating which modernizes embroidery in patchwork wrapping. cloth has become a new technique which can create high values with its extended the visual effects of the material. Fifthly, Patchwork wrapping cloth in Chosun Dynasty has now become a motive for modem fashion design to express tradition and creation.

세균성 동맥내막염을 동반한 개방성 동맥관의 치험예 (Surgery of the Infected Patent Ductus Arteriosus with Teflon Wrapping)

  • 조범구
    • Journal of Chest Surgery
    • /
    • 제5권1호
    • /
    • pp.25-28
    • /
    • 1972
  • Patent ductus arteriosus is one of the most common congenital heart diseases, which treated operatively has excellent results. Treatment by surgical means is common and invariably successful. However,infected PDA cases present problems and surgeons operating must face the possibility of adhesions,aneurysmal dilatation and friabiilty of tissue with tearing of the pulmonary arterial end, especially, which causes a fatal hemorrhagic ccmplication. In the earlier days of cardiac surgery, many surgeons deferred operative treatment infected PDA because of frequent complications, high postoperative morbidity and mortality. This continued until Touroff et al. successfully divided the infected PDA in 1940. In 1944, Harper et aI. have used Cellophane for the wrapping of the infected PDA. This surgical procedure has become a single, simple and safe method for treating infected PDA, since that time. In the Teflon wrapping technique, a cardiothoracic team of Yonsei University Severance Hospital used Teflon felt instead of Cellophane in one case of infected PDA and this method proved intractable to antibiotic treatment for 40 days.

  • PDF