• Title/Summary/Keyword: Working width

Search Result 185, Processing Time 0.018 seconds

Study on the Electrical Properties of W-interconnected DSSC Modules According to Variation of the Working Electrode Width (광전극 폭 변화에 따른 W-상호연결 염료감응 태양전지 모듈의 전기적 특성 연구)

  • Oh, Byeong-Yun;Kim, Sang-Ki;Kim, Doo-Gun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.298-303
    • /
    • 2013
  • In this study, the W-interconnected dye-sensitized solar cell (DSSC) modules composed of a number of rectangular cells connected in series were investigated, where neighboring cells are processed in reverse. The DSSC modules, a module of dimension about 200 mm ${\times}$ 200 mm, were fabricated with different working electrode width ranging from 5 mm to 21 mm. The short-circuit current of the module increased as the working electrode width increased. Whereas, the decrease in the working electrode width resulted in the increase of the conversion energy efficiency, fill factor, and open-circuit voltage, which is explained by the fact that the possibility that electrons are recombined along their path on the transparent conductive oxide substrate decreases. The module with the conversion energy efficiency of 3.59% was obtained with the working electrode width of 5 mm.

Threshing Performance dependent upon Feed Rate and Threshing Drum Length for Head-Feed Combine (공급률 및 탈곡통 길이 변화에 따른 자탈형 콤바인 탈곡 성능)

  • Seo, Sin-Won;Lee, Sang-Woo;Huh, Yun-Kun
    • Korean Journal of Agricultural Science
    • /
    • v.33 no.2
    • /
    • pp.159-166
    • /
    • 2006
  • Threshing loss was increased due to dropping of the threshing efficiency when the 4 row head-feed combine harvested 5 row rice to improve harvesting performance of a combine. Reasonable design criteria were examined to determine the ranges of both of feed rate and the length of threshing drum for the 4 row head-feed combine being used as a 5-row combine. Harvesting performance increased as working width or working speed increased, it resulted in 15% increase when the working width increased from 4 row to 5 row. Harvesting operations of the 4 row combine performed normally in the 4 row rice in threshing loss less than 1%, however, threshing loss increased to 2.25% in the 5 row due to poor threshing efficiency. The length of threshing drum was increased from 710 mm to 810 mm as well as the speed of crop feed chain was increased from 0.61 m/s to 0.75 m/s so as to improve the poor threshing efficiency resulted from the enlarged working width from the 4 row to the 5 row, which would decrease threshing loss less than 1%.

  • PDF

Required Mowing Power and Bale Density of Miscanthus × Giganteus for Field Biomass Harvesting using Different Methods

  • Jun, Hyeon-Jong;Choi, Il-Su;Kang, Tae-Gyoung;Choi, Yong;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.253-260
    • /
    • 2014
  • Purpose: This study investigated the harvesting properties of the giant miscanthus (Miscanthus ${\times}$ giganteus) to measure the required mowing power for different stem conditioning methods in order to shorten the drying time after mowing and the bale density so that the crop can be used as biomass in the winter season. Methods: The required mowing power and bale density were measured using a power measurement device, three different mower-conditioners, and a mid-sized round baler under different working speeds and conditioning methods. Results: For the various mower-conditioners, the average stem length from mowing was 0.86-0.91 m, and the available working speed was 1.6 m/s. The steel roller-type mower-conditioner showed better stem conditioning but could not mow over a working speed of 1.6 m/s. The required average power of the mower-conditioners varied from 23.8 kW for the steel roller-type rotary disk mower-conditioner with a working width of 2.4 m to 37.2 kW for the flail-type rotary disk mower-conditioner with a working width of 3.2 m at a working speed of 1.6 m/s. The bale densities were $155.8-172.2kg/m^3$. The highest bale density was measured for stems with no conditioning and a moisture content of 11.3% (d.b.) mowed by the rotary disk mower. The bale density was affected by the mowing method because of the low moisture content of the miscanthus stems. Conclusions: In terms of the working performance and conditioning statue, the steel roller-type mower-conditioner is a better choice at a working width of 2.4 m, while the flail finger-type mower-conditioner is better at a working width of 3.2 m. The type of mower-conditioner used for giant miscanthus harvesting should be determined by considering the harvest area, workable period, and working performance of a mower-conditioner and baler during the winter.

The Evaluation on Functionality with Material-improved Working Uniform of Construction Field (소재개선에 따른 건설현장 작업복 착의기능성 평가)

  • Kim, Seong-Suk;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.10 no.2
    • /
    • pp.228-235
    • /
    • 2008
  • The purpose of this study is to examine the functionality with material-improved working uniform(protocol, P) and current working uniform(control, C). Movement functionality evaluation of material-improved working uniform was carried out through sensory evaluation of working uniform. And Oxygen uptake was explored to different working uniform(P, C) in relation to a physiological functionality measurement. The results have been shown as follows: It was found that the workers feel uncomfortable with the parts of the wrist, the back width, the shoulder seam and the side in the current working uniform when they move their arms up and down, but the inconvenience has been reduced in the material-improved working uniform. And It was found that the workers feel uncomfortable with the parts of the back width, the wrist and the side seam of the jacket, and the waist, the hips and the thigh of the trousers in the current working uniform when they move their waist, but the inconvenience has been reduced in the material-improved working uniform. In the current working uniform, it was also found that they feel uncomfortable with the parts of the horse riding position in which they stand straight in their slightly bended knees, with the parts of the hips, the side seam, the thigh and the knees when they crouch down, and with the parts of the hips and the thigh when they put one of their legs onto a higher place. However, the inconvenience was reduced in the material-improved working uniform. Oxygen uptake, which was measured to assess physiological dressing functionality, was found to be higher when people work in an uncomfortable uniform than when they work in a uniform of better functionality by an increase in metabolic rate, which can be a cause of workers' inefficiency of fatigue.

Speed Control of DC Motor for Roller Type Seeder (롤러형 파종기 구동용 직류모터의 회전속도 제어)

  • 이중용;김유용;박상래
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.351-358
    • /
    • 2000
  • This study was conducted to develop a speed control system of a DC motor which drove a barley seeder mounted on a combine harvester. Barley seeder mounted on a combine has been known to reduce labor and cost of barley cultivation. However, development of the seeder has been unsuccessful because the combine, a dedicated rice and barley harvester has not enough space and proper power take-off for barley seeder. To develop a barley seeder, small powered motor speed controller was required. A proximity sensor for detecting working speed of the combine and a programmable one board microprocessor was used to develope a control system. Motor parameters and motor constant, relationship between seeding rate, motor speed, groove volumes of a tested roller, torque were measured. The proximity sensor sent a frequency signal to the microprocessor. In laboratory experiments, the excitation voltage of the motor was shown not to be proportional to the size of pulse width (duty ratio). A table transforming frequency signal, that represented for working speed to proper pulse width was developed from seeding rate experiments. However, seeding rate at low frequency signal was not proportional to the working speed. Seeding rate control proportional to the frequency signal was achieved by shifting of the frequency signal.

  • PDF

The effect of working parameters on removal of casting gold alloy using a piezoelectric ultrasonic scaler with scaler tip in vitro (압전방식 초음파 치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Cha, Kuk-Bong;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.139-148
    • /
    • 2009
  • Purpose: Ultrasonic scalers have been widely used for removing biofilm which is considered as major etiologic factor of periodontal disease. The purpose of this study was to evaluate the effect of working parameters of piezoeletric ultrasonic scaler with scaler tip (No. 1 tip) on casting gold alloy removal. Methods: Type III dental casting gold alloy (Firmilay$^{circledR}$, Jelenko Inc, CA, USA) was used as substitute for tooth substance. Piezoeletric ultrasonic scaler and No.1 scaler tip (P-Max$^{circledR}$, Satelec, France) were selected. The selected working parameters were mode (P mode, S mode), power setting (2, 4, 8) and lateral force (0.5 N, 1.0 N, 2.0 N). The effect of working parameters was evaluated in terms of ablation depth, ablation width and ablation area. Results: Mode influenced ablation depth and ablation area. Power also influenced ablation depth and ablation area. Especially, Power 2 and power 8 showed statistically significant difference. Lateral force had influence on ablation width, and 0.5 N resulted significant increase compared with 1.0 N and 2.0 N. Ablation depth was influenced by mode, power and lateral force and defect width was influenced by lateral force. Ablation area was influenced by mode and power. Conclusions: It can be concluded that the use of piezoelectric ultrasonic scaler with No. 1 scaler tip in S mode and high power may result in significant loss of tooth substance.

A Study on the Design of Rural Kitchen Furniture (농촌생활에 적합한 부엌가구 디자인요소와 모델 계획연구)

  • Yoon, Bok-Cha;Chi, Soon;Yoon, Chung-Sook;Park, Eun-Seon;Lee, Eun-Kyung;Kim, Hee-Jung
    • Korean Institute of Interior Design Journal
    • /
    • no.2
    • /
    • pp.29-39
    • /
    • 1994
  • The purpose of this study was to design rural kitchen furnitures. Thirty seven rural houses were selected for this study. Present and past uses of space for cooling and dining were investigated by a field survey method. The Major findings were that ; 1) Sink, mixing, and range centers should be installed in rural kitchen 2) The depth of working center, 550-600mm was recommended. And working space cold be added by 150mm in depth and 100mm in height. The height of working center, 820mm-850mm was recommended . The minimum width of sink was 900 mm and the optimum one was 1200mm. The optimum width of mixing center and cooking center were 600m respectively 3) In the low ceiling of kitchen or the wooden structure of kitchen, a wall cabinet without upper cupboard was recommended. On the basis of the results, four types of rural kitchen furnitures is proposed.

  • PDF

The Comparison of Simple Reaction Time between Young and Old Generation (청년층과 노인층의 단순반응속도 비교에 관한 연구)

  • Kwon Kyu-Sik;Choi Chul
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.4
    • /
    • pp.133-140
    • /
    • 2004
  • This study deals with human reaction speed according to human physical conditions (body size) such as head width, thickness, breast width, arm extent, and age. Especially, the results of this study are compared between young and old generation. According to this study, the thickness and extent factor do not have any correlation with human reaction speed, but width factors(head width, breast width, etc) have some correlation with human reaction speed. The result of this study can be used to find fitter person for a special job such as emergency condition job, sports man (because you can find a person having a good talent for it without test). Also, the purpose of this study is to find CNT (Channel Noise Time). The word of CNT is to explain the relation between Channel Noise and working speed. (Channel Noise is a kind of noise happening between the human information transmission channel.)

A Study on Level-of-Service Changes of Expressway in Accordance with the Revision of Traffic Capacity at Work-Zone (교통용량 개정에 따른 고속도로 공사구간의 서비스 수준에 대한 연구)

  • Ryu, SungWoo;Park, Kwon-Jea;Han, SeungHwan;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.109-117
    • /
    • 2014
  • PURPOSES : This study analyzes the available working time at work-zone on the Expressway in accordance to the new capacity manual. METHODS : Sensitivity analysis on variables were conducted to calculate the adjusted capacity at work-zone based on previous researches. RESULTS : The main factors which affect available working time at the work-zone were its capacity, number of lanes, terrain and lane width. Other factors have minimal effect on the available working time. Based on the analysis, a calendar of lane closures was suggested. CONCLUSIONS : A series of studies concluded that the capacity at work-zone in the new capacity manual reduced to 76-82% of the existing manual. As such, the available working time decreased. Furthermore, the factors affecting the available working time needs to be considered when making a plan to rehabilitate the distressed pavement.