• Title/Summary/Keyword: Working length

Search Result 565, Processing Time 0.039 seconds

Establishment of the roof model and optimization of the working face length in top coal caving mining

  • Chang-Xiang Wang;Qing-Heng Gu;Meng Zhang;Cheng-Yang Jia;Bao-Liang Zhang;Jian-Hang Wang
    • Geomechanics and Engineering
    • /
    • v.36 no.5
    • /
    • pp.427-440
    • /
    • 2024
  • This study concentrates on the 301 comprehensive caving working face, notable for its considerable mining height. The roof model is established by integrating prior geological data and the latest borehole rock stratum's physical and mechanical parameters. This comprehensive approach enables the determination of lithology, thickness, and mechanical properties of the roof within 50 m of the primary mining coal seam. Utilizing the transfer rock beam theory and incorporating mining pressure monitoring data, the study delves into the geometric parameters of the direct roof, basic roof movement, and roof pressure during the initial mining process of the 301 comprehensive caving working face. The direct roof of the mining working face is stratified into upper and lower sections. The lower direct roof consists of 6.0 m thick coarse sandstone, while the upper direct roof comprises 9.2 m coarse sandstone, 2.6 m sandy mudstone, and 2.8 m medium sandstone. The basic roof stratum, totaling 22.1 m in thickness, includes layers such as silty sand, medium sandstone, sandy mudstone, and coal. The first pressure step of the basic roof is 61.6 m, with theoretical research indicating a maximum roof pressure of 1.62 MPa during periodic pressure. Extensive simulations and analyses of roof subsidence and advanced abutment pressure under varying working face lengths. Optimal roof control effect is observed when the mining face length falls within the range of 140 m-155 m. This study holds significance as it optimizes the working face length in thick coal seams, enhancing safety and efficiency in coal mining operations.

Comparison of the ability of Reciproc and Reciproc Blue instruments to reach the full working length with or without glide path preparation

  • Adiguzel, Mehmet;Tufenkci, Pelin
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.41.1-41.7
    • /
    • 2018
  • Objectives: The purpose of the present study was to compare the mean preparation times and frequency with which Reciproc and Reciproc Blue instruments reached the full working length in mandibular molars, with or without glide path preparation. Materials and Methods: Previously untreated mesiobuccal and mesiolingual canals with completely formed apices were randomly divided into 6 groups (n = 50) depending on the usage of Reciproc (RC; VDW), Reciproc Blue (RC Blue; VDW), C-Pilot (CP; VDW), and R-Pilot (RP; VDW) files: RC, RC Blue, RC + C-Pilot (RC-CP), RC-Blue + C-Pilot (RC Blue-CP), RC+R-Pilot (RC-RP), and RC Blue + R-Pilot (RC Blue-RP). A glide path was prepared using the hand-operated C-Pilot or the machine-operated R-Pilot instruments, respectively. The ${\chi}^2$ test, analysis of variance, and the Tukey post hoc test were used for statistical comparisons. Results: No statistically significant differences were observed in the distribution of the frequency of reaching the full working length in the RC (94%), RC Blue (88%), RC-CP (94%), RC Blue-CP (90%), RC-RP (96%), and RC Blue-RP (92%) groups (p > 0.05). Conclusions: Preparation of a glide path did not have a significant effect on reaching the full working length using these systems.

Effects of canal enlargement and irrigation needle depth on the cleaning of the root canal system at 3 mm from the apex (근관확대 및 세척 주사바늘의 근관 내 위치가 치근단 3 mm 부위의 근관 세정에 미치는 영향)

  • Moon, Ho-Jin;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of ${\times}250$, ${\times}500$, ${\times}1,000$, ${\times}2,500$ were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.

A Study on Factors Influencing Perceptions of Dental Hygienists' Environmental Working Conditions (치과위생사의 작업환경 인식에 영향을 미치는 요인)

  • Choi, Min-Ji;Park, Eui-Jung
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.539-547
    • /
    • 2020
  • Objectives: This study was performed to emphasize improvement of the perception of dental hygienists' environmental working conditions by analyzing various factors. Methods: Two hundred ninety-eight female dental hygienists working at 35 medical institutions in Daegu City and Gyeongsangbuk-do Province participated. A self-recording type survey was done in October 2016. Results: Factors influencing the perception of infection control was length of career. Dental hygienists with more experience have a higher level of perception. Factors influencing the perception of working posture was the number of patients per day and career level. Dental hygienists seeing 50 or fewer patients per day and senior staff showed higher levels of this perception. Factors influencing the perception of noise in the working area were length of career and lunchtime break. The perception level was high in the group with longer careers and dental hygienists who rest at lunch time. Factors influencing chemical exposure during work were the number of patients per day and the type of institute. Dental hygienists working in dental clinics or dealing with more patients had lower levels of perception. Conclusions: The sociodemographic and working characteristics of dental hygienists influence the perception of dental hygienists' environmental working conditions.

THE EFFECT OF THE CANAL IRRIGANTS ON THE ELECTRONIC WORKING LENGTH DEVICE (전자 근관장측정기 사용에 있어서 근관세척제의 사용이 측정에 미치는 영향에 관한 연구)

  • Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.127-133
    • /
    • 1990
  • Electronic working length determination is based on the electrical impedence between the root canal and the periodontal ligament Different canal irrigants with different electric conductivity may effect on the accuracy of the electronic mechanism. 0.9% Saline, 2.5% NaOCl and 3% $H_2O_2$ were evaluated either in wet or in dry condition. The results were as follows. 1. The electrical resistance mearured by Impedence Meter (Model #253, portland, USA) were 1 $K{\Omega}$ in 0.9% Saline, 0.1$K{\Omega}$ in 2.5% NaOCl and 48 $K{\Omega}$ in 3% $H_2O_2$. 2. Saline measured -0.57mm from the actual canal length and had significant difference. When dried with paper points, however, it measured -0.25mm demonstrating no statistical difference. 3. 2.5% NaOCl measured -4.07mm in wet and -2.26mm in dry condition and both showed significant difference from the actual canal length. 4. 3% $H_2O_2$ measured +0.02mm in wet and -0.09mm in dry canals and both appeared to be within acceptable range for the electronic working length mechanism.

  • PDF

A STUDY ON THE ACCURACY OF THE ROOT-ZX IN THE CANAL WITH MECHANICALLY FORMED CONSTRICTION (기계적 협착부를 갖는 근관에서 Root-ZX의 정확도에 관한 연구)

  • Kim, Byung-Hyun;Lee, Young-Kyoo;Kim, Young-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.628-632
    • /
    • 1999
  • Currently electronic apex locators have been widely used to determine working length in endodontic treatment. According to Manufacture's recommendation, it is beneficial to find the working length before instrumenting the canal. However, in crown-down pressureless technique, working length of tooth is established following coronal instrumentation 3mm short of radiographic apex. In narrow canals, mechanically formed constriction might be established by coronal instrumentation in some distance from anatomical constriction. The purpose of this study was to evaluate the accuracy of Root-ZX in the canal with mechanical constriction following considerable coronal enlargement with ProFile .06 series. The 40 root canals in 30 extracted mandibular molars were accessed, and their actual length (AL) established by passing a size 10 file just through the minor apical foramen. The teeth were then embedded in an acrylic container with normal saline. The initial canal length(IL) was measured with Root-ZX by negotiating a size 10 file to the apical constriction. The canal was sequentially enlarged to size 40 with ProFile .06 file 3mm short of actual length. The enlarged final canal lengths (FL) were obtained with a size 15 file. The average values of IL, FL were calculated and compared using Repeated measures Analysis of Variance followed Turkey's Studentized Range test. The results were obtained as follows: 1. The initial canal length was 0.12mm shorter than actual canal length(P>0.05). 2. The differences between initial canal length and final canal length were not significant(P>0.05). 3. As a result of this study, regardless of mechanically formed constriction. Root-ZX differentiated between mechanical and anatomic constriction.

  • PDF

Thermo-physiological Responses by Presence of Vents and Difference in Clothing Length for Construction Site Working Clothes (통기구 유무와 옷 길이 차이에 따른 건설현장 작업복의 온열생리반응)

  • Kim, Seong-Suk;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.20 no.2
    • /
    • pp.202-209
    • /
    • 2018
  • This study examined thermo-physiological responses according to the design change of construction site working clothes (control (C) working clothes; prototype (P) working clothes). We measured rectal temperature, skin temperature, micro-climate within the clothes and sweat rate. In the evaluation of physiological functionality, based on pattern improvement in working clothes, P working clothes showed significantly lower rectal temperatures, trunk and thigh skin temperatures than C working clothes. It is preferable that rectal temperature should be kept low during work that is not favorable to an increase in body temperature. P working clothes were more physiologically functional than C working clothes. In addition, P working clothes showed significantly lower temperatures in the trunk and thigh parts in a micro climate temperature. We could explain that the side seam zipper on the pants and the gusset on armpit parts create an air permeability effect of lowering the temperature of micro-climate. Aggressive ventilation through the slit of the garment is an important factor for the restoration of the physiological function of the worker at rest between work. Sweat rate showed a higher level in C working clothes than P working clothes. When working in a hot environment, workwear needs to be designed so that the worker is not exposed to thermal stress. Therefore, it was evaluated that the P work clothes used in this study alleviated the physiological burdens of heat.

Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length

  • Yoo, Jin Suk;Kwon, Kung-Rock;Noh, Kwantae;Lee, Hyeonjong;Paek, Janghyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.143-151
    • /
    • 2017
  • PURPOSE. The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. MATERIALS AND METHODS. Test model was created with epoxy resin. The strain gauges made a tight contact with implant surfaces. A universal testing machine was used to exert a vertical pressure on the mandibular implant overdenture and the strain rate of the implants was measured. RESULTS. Means and standard deviations of the maximum micro-deformation rates were determined. 1) Locator attachment: The implants on the working side generally showed higher strain than those on the non-working side. Tensile force was observed on the mesial surface of the implant on the working side, and the compressive force was applied to the buccal surface and on the surfaces of the implant on the non-working side. 2) Bar/clip attachment: The implants on the both non-working and working sides showed high strain; all surfaces except the mesial surface of the implant on the non-working side showed a compressive force. CONCLUSION. To minimize the strain on implants in mandibular implant overdentures, the attachment of the implant should be carefully selected and the denture base should be extended as much as possible.

An Analysis of the Job Sequences of the Working Poor (근로빈곤층의 직업력 분석 -비빈곤층과의 비교를 중심으로-)

  • Choi, Ok-Geum
    • Korean Journal of Social Welfare
    • /
    • v.60 no.4
    • /
    • pp.55-77
    • /
    • 2008
  • After the economic crisis of Korea, the character of Korean Poverty has changed. Most notably, many people are working but poor. Therefore it is important to understand the characteristics of the working poor, especially the unstable work experiences of the working poor since one of the causes of poverty is that. Prior research about the working poor has not fully proven this issue. This study is to examine the job sequences of the working poor. Thus I utilized the KLIPS(Korea Labor and Income Study), and analyzed it by event sequence analysis and optimal matching methods. The job sequences are divided as follows: total years of working in the labor market, the number of gaps and the length of gaps in their careers, and the characteristics of experienced jobs since they have entered the labor market from age 15. As a result, there are no statistically significant in the total years of working in the labor market. And the number of gaps and the length of gaps in their careers, and the characteristics of experienced jobs show that working poor have been experiencing more unstable than non-poor. Thus, almost all of the male working poor has unstable jobs their whole lives, and the female working poor's job sequences show distinct features according to women's life course. These results can give political implications to the anti-poverty policy in Korea.

  • PDF