• Title/Summary/Keyword: Working distance

Search Result 505, Processing Time 0.029 seconds

Measuring Economic Values of Amenity Services from Urban Greenspaces in the Seoul Metropolitan Area Using Choice Experiments (선택실험을 이용한 서울 도시녹지 어메니티의 경제가치 평가)

  • Choi, Andy S.;Eom, Young Sook
    • Environmental and Resource Economics Review
    • /
    • v.27 no.1
    • /
    • pp.105-138
    • /
    • 2018
  • This paper reports novel empirical results of a choice experiment that elicited the economic values that residents in the Seoul metropolitan area place on the amenity services realized from the landscape views and accessibilities to urban green spaces (i.e., mountains, rivers and urban parks). The 1,000 respondents in the sample were divided into two residential of housing types (apartments vs. houses) and occupancy types (owners vs. tenants). Residents living in apartments are willing to pay an average of 28% (5.0 million KRW per year) above the current housing prices per household for a mountain view, compared to an apartment view from their living room. Their willingness to pay values are about 22% (4.0 million KRW per year) and 10% (1.8 million KRW per year) respectively for a river view and a urban park view. Economic benefits of having access (i.e., a 10 minutes working distance) to mountains, rivers and urban parks are estimated to be an average of 16% (2.9 million KRW per year), 20% (3.6 million KRW per year) and 18% (3.2 million KRW per year), respectively, above the current housing prices per household. On the other hand, access benefits for those residing in houses are 18% (4.7 million KRW per year), 16% (4.1 million KRW per year) and 22% (5.6 million KRW per year) per household, respectively. They are also willing to pay an average of 35% (8.9 million KRW per year) above the current housing prices for keeping or having a garden or vegetation bed. Furthermore, a strong "greenspace premium" is centered around the three Gangnam districts for house-dwellers, whereas it is areas of "new real estate boom" for apartment dwellers.

Preliminary Report on the Geology of Sangdong Scheelite Mine (상동광산(上東鑛山) 지질광상(地質鑛床) 조사보고(調査報告))

  • Kim, Ok Joon;Park, Hi In
    • Economic and Environmental Geology
    • /
    • v.3 no.1
    • /
    • pp.25-34
    • /
    • 1970
  • Very few articles are available on geologic structure and genesis of Sangdong scheelite-deposits in spite of the fact that the mine is one of the leading tungsten producer in the world. Sangdong scheelite deposits, embedded in Myobong slate of Cambrian age at the southem limb of the Hambaek syncline which strikes $N70{\sim}80^{\circ}W$ and dips $15{\sim}30^{\circ}$ northeast, comprise six parallel veins in coincide with the bedding plane of Myobong formation, namely four footwall veins, a main vein, and a hangingwall vein. Four footwall veins are discontinuous and diminish both directions in short distance and were worked at near surface in old time. Hangingwall vein is emplaced in brecciated zone in contact plane of Myobong slate and overlying Pungchon limestone bed of Cambrian age and has not been worked until recent. The main vein, presently working, continues more than 1,500 m in both strike and dip sides and has a thickness varying 3.5 to 5 m. Characteristic is the distinct zonal arrangement of the main vein along strike side which gives a clue to the genesis of the deposits. The zones symmetrically arranged in both sides from center are, in order of center to both margins, muscovite-biotite-quartz zone, biotite-hornblende-quartz zone and garnet-diopside zone. The zones grade into each other with no boundary, and minable part of the vein streches in the former two zones extending roughly 1,000 m in strike side and over 1,100 m in dip side to which mining is underway at present. The quartz in both muscovite-biotite-quartz and biotite-hornblende-quartz zones is not network type of later intrusion, but the primary constituent of the special type of rock that forms the main vein. The minable zone has been enriched several times by numerous quartz veins along post-mineral fractures in the vein which carry scheelite, molybdenite, bismuthinite, fluorite and other sulfide minerals. These quartz veins varying from few centimeter to few tens of centimeter in width are roughly parallel to the main vein although few of them are diagonal, and distributed in rich zones not beyond the vein into both walls and garnet-diopside zone. Ore grade ranges from 1.5~2.5% $WO_3$ in center zone to less than 0.5% in garnet-diopside zone at margin, biotite-hornblende-quartz zone being inbetween in garde. The grade is, in general, proportional to the content of primary quartz. Judging from regional structure in mid-central parts of South Korea, Hambaek syncline was formed by the disturbance at the end of Triassic period with which bedding thrust and accompanied feather cracks in footwall side were created in Myobong slate and brecciated zone in contact plane between Myobong slate and Pungchon limestone. These fractures acted as a pathway of hot solution from interior which was in turn differentiated in situ to form deposit of the main vein with zonal arrangement. The footwall veins were developed along feather cracks accompanied with the main thrust by intrusion of biotite-hornblende-quartz vein and the hangingwall vein in shear zone along contact plane by replacement. The main vein thus formed was enriched at later stage by hydrothermal solutions now represented by quartz veins. The main mineralization and subsequent hydrothermal enrichments had probably taken place in post-Triassic to pre-Cretaceous periods. The veins were slightly displaced by post-mineral faults which cross diagonally the vein. This hypothesis differs from those done by previous workers who postulated that the deposits were formed by pyrometasomatic to contact replacement of the intercalated thin limestone bed in Myobong slate at the end of Cretaceous period.

  • PDF

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.

Effectiveness Evalution of 18F-FDG Auto Dispenser (RIID: Radiopharmaceutical Intelligent Dispenser) (18F-FDG 자동분주기 사용에 따른 유용성 평가)

  • Yoo, Moon-Gon;Moon, Jae-Seung;Kim, Su-Geun;Shin, Min-Yong;Kim, Seung-Chul;Lee, Tea-hun;An, Sung-Hyeun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • Purpose $^{18}F-FDG$, which is commonly used in PET-CT examinations, is low in capacity and it is difficult to keep the amount of radioactivity busy when the specific activity is high, increasing the amount of space dose and radioactive contamination in the distribution room. Therefore, while evaluating the actual dose administered to patients during the manual dispense process, the medical institution intends to assess the usefulness of the auto dispenser by comparing the differences from the actual dose administered to the patient using the new automatic dispense. Materials and Methods From July 2016 to December 2016, 846 patients were manually administered by workers using $^{18}F-FDG$ and $^{18}F-FDG$ 906 patients were using auto dispenser from July 2017 to December 2017. Results Capacity administered to patients during the manual dispense averaged $35.41{\pm}27.79%$ compared to the recommended dose, and the auto dispenser process showed a small difference of $-2.15{\pm}3.99%$ compared to the recommended dose(p<0.05). Conclusion Working people did not have to touch radioactive medicines directly while they were busy in the auto dispenser, and because of the availability of other tasks far away, the time and distance to receive the exposure were also advantageous. It is believed that future use by many medical institutions will not only reduce the dose to patients but also help reduce the exposure dose to workers.

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF