• 제목/요약/키워드: Working capacity

검색결과 593건 처리시간 0.026초

Studies on Supply and Demand Paradox in Shipping Market

  • Kim, Jin-Hwan
    • 산경연구논집
    • /
    • 제10권1호
    • /
    • pp.19-27
    • /
    • 2019
  • Purpose - The purpose of the paper is to examine disconnection between supply and demand shipping market, which means shipowner has determined to raise capacity in bust period. Research design, data, and methodology - The research method to be applied is first to look into conceptual theory about shipping market, and then to study imbalance of supply and demand situations in shipping on crisis, and next, to analyses paradoxical aspects traced. Results - Shipping market is a volatile and cyclic characteristics, and its situations have to be examined very carefully. Since financial crisis has broken up in 2008, it is natural to think that world trade volumes has reduced rapidly, which means demand for shipping service has fallen, and accordingly, tonnage should be stagnated as well. However, shipping companies have put capacity into market as unexpectedly. This is because of economy of scale and time lag. Here, this can be explained in terms of paradox that is proved in this paper. Conclusions - From careful research in this paper, it is found that supply and demand are not always got along with market situations, in other words supply side could be working well, in spite of depression time of demand situations in world shipping markets.

건설기계용 유압실린더 위치 제어시스템의 성능개선에 관한 연구 (A study on performance improvement of position control system in hydraulic cylinder for heavy construction machinery)

  • 한석재;박성환;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1450-1454
    • /
    • 1996
  • Even though digital control type high speed solenoid valve is a little inferior to analog control type servo valve and proportional control valve in performance, it is cheap and has secure performance against pollutant and simple control circuit. But high speed solenoid valve is hardly used for heavy machinery instead of servo valve or proportional control valve that is used in severe condition because the valve itself is small capacity and it shows wide dead zone during on-off control and chattering of hydraulic cylinder by chattering of pressure. It is desirable to use low-priced and strong pollutant resistant high speed solenoid valve for obtaining reliability of operation from severe working condition because it isn't necessary to acquire response characteristic of high frequency when we consider the characteristic of heavy machinery operation. In this study, PWM control algorithm for pilot pressure control of large capacity pilot operating valve will be used for precision position control of heavy machinery hydraulic cylinder. Not only cost reduction of main control valve but also high reliability of heavy machinery in severe condition can be obtained by using this pilot operating spool valve with high speed solenoid valve.

  • PDF

용액유량에 따른 플레이트 흡수기의 흡수 열전달 특성 실험 (Experimental Study on Heat Transfer Performance of Plate Type Absorber with Variation of Solution Flow Rate)

  • 문춘근;방기석;김재돌;윤정인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1548-1553
    • /
    • 2003
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of development of high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is the most effective to improve the performance of absorber with the largest heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which can increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, horizontal tube bundle type. The size of plate absorbers were made for $0.4m{\times}0.6m$ and the design object of a refrigeration capacity was lRT. In this experiment, three kind plate absorbers which were flat plate, dimple plate and groove plate were used. The results were less than the design object values, that is, the refrigeration capacity was about $0.3{\sim}0.4RT$ and the overall heat transfer coefficient was $500{\sim}600kcal/m^2h^{\circ}C$ at the standard conditions.

  • PDF

액체 제습식 냉방 사이클의 최적화 (Optimization of Liquid Desiccant Cooling Cycle)

  • 김선창;김영률;이상재;전동순;최장현;권혁민;이창준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.673-678
    • /
    • 2009
  • This paper presents the optimization process of liquid desiccant cooling cycle using LiCl aqueous solution as a working fluid. Operating conditions and design factors for heat exchangers were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of $dT_{hw}$ on system performances was also examined. As $dT_{hw}$ increases, the cooling capacity increases and COP decreases.

  • PDF

Utility Interactive PV Systems with Power Shaping Function for Increasing Peak Power Cut Effect

  • Choe, Gyu-Ha;Kim, Hong-Sung;Heo, Hye-Seong;Jeong, Byong-Hwan;Choi, Young-Ho;Kim, Jae-Chul
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.371-380
    • /
    • 2008
  • This paper describes the Utility Interactive PV (UIPV) system which can improve the peak-cut effect by adding an energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and an application algorithm have been applied to the UIPV system which is based on working PV system during a 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. The proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve the power capacity of peak cut.

전기구동 파워트레인의 감속기어비 설계를 위한 농용 트랙터의 작업 부하 분석 (Analysis of Agricultural Working Load Experiments for Reduction Gear Ratio Design of an Electric Tractor Powertrain)

  • 김정윤;박영일
    • 한국자동차공학회논문집
    • /
    • 제20권5호
    • /
    • pp.138-144
    • /
    • 2012
  • Recent environmental issues such as exhaust gas and greenhouse effect make the agricultural machinery market takes into account the hybrid and electric propulsion technology used in automotive engineering. Generally the agricultural machinery, particularly an agricultural tractor, needs large load capacity and long continuous operating time comparing with conventional vehicles. In case of a pure electric tractor, it is necessary for considering large capacity batteries and long charging time. Therefore we take an AER extended PHEV (All Electric Range extended Plug-in Hybrid Electric Vehicle) power transmission system in developing an electric tractor in this study. First we propose a PHEV powertrain structure in order to substitute the conventional diesel engine equipped tractor. And we performed the road tests using a conventional mechanical tractor with various load conditions, which were classified and statistically treated real agricultural works. The test results were analysed with respect to the power characteristics of the power source. Finally using the test result, we designed two-stepped reduction gear ratios in the proposed an electric tractor powertrain for carrying out typical agricultural works.

액체 제습식 냉방 시스템의 최적 설계 (Optimization Design of Liquid Desiccant Cooling System)

  • 전동순;이상재;김선창;김영률;이창준
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.419-428
    • /
    • 2010
  • This paper presents the optimization process of liquid desiccant cooling system using LiCl aqueous solution as a working fluid. Operating conditions(mass flow rate, conditioner outlet concentration, difference concentration) and design factors for heat exchangers(difference temperature of the district heating water, leaving temperature difference of the conditioner, leaving temperature difference of the regenerator, air temperature difference of the conditioner, air temperature difference of the regenerator) were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of difference temperature of hot water on system performances was also examined. As difference temperature of the district heating water increases, the cooling capacity increases and COP decreases.

전국 수은 취급사업장의 작업환경 실태 조사 연구 (A Study of Field Survey on Working Environment for Mercury Treatment Establishments in Korea)

  • 엄성인;백존배;이영섭
    • 한국안전학회지
    • /
    • 제7권3호
    • /
    • pp.30-34
    • /
    • 1992
  • This study is conducted to evaluate the airborne concentration of mercury, as well as installation and efficiency of local exhaust ventilation system for 57 factories manufactured fluorescence lamps, mercury lamps and thermometers for July and August 1990. Results and conclusion are as fellows : 1) Mercury treatment factories are 32 among 57 ones, which are 18 fluorescence lamp manufacturing ones and 6 mercury lamp ones and 3 thermometer ones and 5 other ones. 2) Mean airborne concentrations of mercury for factories manufactured mercury lamps are 0.01 mg/ ㎥ in injection process and 0.0155mg/㎥ in exhaust process, and mean airborne concentration of mercury for factories manufactured thermometer are 0.023mg/㎥ in injection process and 0.012mg/㎥ in selection process. All of these airborne concentrations of mercury are lower than PEL(Permissible Exposure Limit ), 0.05mg/㎥. 3) Mean airborne concentrations of mercury for factories manufactured fluorescence lamps are 0.094mg/㎥ in injection process and 0.087mg/㎥ in exhaust process, and 0.052mg/㎥ in sealing process and 0.085mg/㎥ in other process, respectively. All of these air borne concentrations of mercury are exceeded to PEL. More than 60% among 32 factories manufactured mercury are exceeded to PEL. 4) Nine factories among 18 factories manufactured fluorestence lamps are equipped with local exhaust ventilation system, and 7 factories among 9 factories are required for the improvement of suction capacity and structure. Five factories among 14 factories manufactured mercury lamps and the other ones are equipped with local exhaust ventilation system, and 2 factories are required for the improvement of suction capacity and structure.

  • PDF

Cell-balancing Algorithm for Paralleled Battery Cells using State-of-Charge Comparison Rule

  • La, Phuong-Ha;Choi, Sung-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.156-158
    • /
    • 2018
  • The inconsistencies between paralleled battery cells are becoming more considerable issue in high capacity battery applications like electric vehicles. Due to differences in state-of-charge (SOC) and internal resistance within individual cells in parallel, charging or discharging current is not appropriately balanced to each cell in terms of SOC, which may shorten the lifetime or sometimes cause safety issues. In this paper, an intelligent cell-balancing algorithm is proposed to overcome the inconsistency issue especially for paralleled battery cells. In this scheme, SOC information collected in the sub-BMS module is sent to the main-BMS module, where the number of parallel cells to be connected to DC bus is continuously updated based on the suggested SOC comparison rule. To verify the method, operation of the algorithm on 4 paralleled battery cells are simulated on Matlab/Simulink. The simulation result shows that the SOCs of paralleled cells are evenly redistributed. It is expected that the proposed algorithm provides high reliable and prolong the life cycle and working capacity of the battery pack.

  • PDF

탄화수소 냉매를 사용한 냉방시스템의 성능 및 열전달 특성 (Performance and heat transfer of an air conditioning system filled with hydrocarbon refrigerants)

  • 장영수;김민수;노승탁
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.713-723
    • /
    • 1997
  • Performance and heat transfer characteristics of an air conditioning system filled with hydro- carbon refrigerants are experimentally investigated. Single component hydrocarbon refrigerants (propane, isobutane, butane and propylene) and binary mixtures of propane/isobutane and propane/butane are considered as working fluids in the air conditioning system. Performances of each refrigerant are obtained at several compressor speeds and temperature levels of secondary heat transfer fluids. The cooling capacity and the coefficient of performance are obtained as test results. Heat transfer data of selected refrigerants are achieved from overall conductance measurement. Average heat transfer coefficients at different mass fluxes are shown and they are also displayed for different heat capacities of the system. Experimental results show that some hydrocarbon refrigerants have better characteristics than R22.