• Title/Summary/Keyword: Working capacity

Search Result 593, Processing Time 0.021 seconds

Design of CTS for Graduation Album Production (졸업앨범 책자 제작을 위한 컴퓨터조판시스템 설계)

  • Jung, Byung-Wan;Choi, Sin-Hyeong;Han, Kun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1491-1495
    • /
    • 2007
  • Due to proliferation of Digital cameras and high-speed digital printers, anyone can do easily digital photo shoot and print services, but album manufacture for celebrating the graduation or marriage, and a hundred days needs a lot of capacity of image files and requires high quality, therefore that is working in the photo studio's to the whole responsibility. In this paper, we show all album process to product album manufacture quickly and accurately using high-quality template and variety of libraries, and propose CTS(computerized typesetting system) to build album, which separates a role of photo studio, processing laboratory and printing house and can revolutionize a working process.

  • PDF

A Study of Application on the Pulsating Heat Pipe for Heat Transfer Enhancement of Metal Hydride Alloy (수소 저장합금층의 열전달 촉진을 위한 진동형 히트 파이프 적용에 관한 연구)

  • Lee, Min-Jae;Im, Yong-Bin;Bae, Sang-Chul;Kim, Jong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.346-351
    • /
    • 2006
  • When metallic alloys are reacted to hydrogen, heat transfer of storage tank effects hydrogen storage rate and capacity. If pulsating heat pipe are used to improve heat transfer efficiency, production of hydrogen storage tank can be more simple and economical. Experiment of heat pipe was conducted by varying working fluids and heat flux. According to supply heat flux, test indicate that R-22 and R-l42b were found lower temperature difference between evaporator and condenser than R-134a and Ethanol. Thermal resistances of R-22 and R-142b were also lower than others. Using R-142b as a working fluid, heat pipe type hydrogen storage tank is tested in absorption and desorption processes.

  • PDF

Factors Affecting Organizational Commitment: An Empirical Study of Information Technology Sector in Vietnam

  • NGUYEN, Van Thuy;NGUYEN, Trung Kien
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.11
    • /
    • pp.277-284
    • /
    • 2021
  • This study was conducted to determine the factors affecting employees' engagement in Information Technology (IT) enterprises in Vietnam. Quantitative method was used to test the research model. Research data is collected through a survey of 205 employees working in Ho Chi Minh City - Vietnam IT enterprises. The research results show that all seven factors affecting OC are ability, remuneration, training/development, challenging work, teamwork relationship, company policy, and culture, and work environment all make sense. In which, WOE, TER, REM factors are the three most influential factors, while company CPC, T&D, CHW, ABI have a lower impact. The proposed management implications include building, providing, ensuring a good working environment for employees, building/developing relationships within the company, having a policy of salary, bonus, support, and incentives. In addition, appropriate, competitive remuneration, adequate incentives, and rewards for the efforts that the employee has made, training and development of skills and soft skills suitable for each type of work, development orientations for employees, as well as frequent rotation of positions and jobs, in addition to improving employees' capacity, also avoid causing boredom and loss of motivation at work, thereby increasing OC of employees in IT enterprises in Vietnam.

Mechanics of a variable damping self-centering brace: Seismic performance and failure modes

  • Xie, Xing-Si;Xu, Long-He;Li, Zhong-Xian
    • Steel and Composite Structures
    • /
    • v.31 no.2
    • /
    • pp.149-158
    • /
    • 2019
  • The force-deformation behavior, strain distribution and failure modes of a variable damping self-centering brace (VD-SCB) are theoretically analyzed, experimentally studied, and numerically simulated to guide its design. The working principle of the brace is explained by describing the working stages and the key feature points of the hysteretic curve. A large-scale brace specimen was tested under different sinusoidal excitations to analyze the recentering capability and energy dissipation. Results demonstrate that the VD-SCB exhibits a full quasi-flag-shaped hysteretic response, high ultimate bearing capacity, low activation force and residual deformation, and excellent recentering and energy dissipation capabilities. Calculation equations of the strain distribution in different parts of the brace are proposed and are compared with the experimental data and simulated results. The developments of two failure modes are compared. Under normal circumstances, the brace fails due to the yielding of the spring blocking plates, which are easily replaced to restore the normal operating conditions of the brace. A brief description of the design procedure of the brace is proposed for application.

Ergonomic and performance analysis of rail-type boom sprayer for agro-photovoltaic power system

  • Rack-Woo Kim;Jae-Woong Han;Woong Kim
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.1
    • /
    • pp.151-162
    • /
    • 2022
  • This study was conducted to develop a rail-type boom sprayer, performing safe spraying with improved ergonomic postures during pesticide spraying of agro-photovoltaic power system. The sprayer was designed to reduce labor cost and to be safe from pesticide exposure, and was analyzed through a comparison with a conventional spray method. The rail-type boom sprayer, consisted of a self-propelled spray and hose winder, hose, and boom sprayer parts, was designed to automatically pull and spray in the vertical and horizontal directions. The performance of the sprayer for an agro-photovoltaic power system was appropriate. From the analysis of postures with the Ovako Working posture Analysis System (OWAS), Rapid Entire Body Assessment (REBA), and Rapid Upper Limb Assessment (RULA) methods, the musculoskeletal risk factors to the body using the rail-type boom sprayer were less than those with the conventional power sprayer. In addition, the possibility of pesticide poisoning was reduced compared to the conventional power sprayer. The working capacity with the rail-type boom sprayer was more than five times greater, compared with the conventional power sprayer. After performing pesticide spraying with the rail-type boom sprayer, the labor cost was reduced to 42,750 won·yr-1, which was 90% (402,750 won·yr-1) less than the cost with the use of a conventional power sprayer (445,500 won·yr-1).

Diesel Exhaust Particle Exposure and its Pulmonary Function Effects (경유차량 배출물질의 노출과 폐기능의 상관성 연구)

  • Lee, Yong-Jin;Kim, Da-Hye;Kim, Soo-Hwan;Kim, Jeong-Soo;Shin, Dong-Chun;Lim, Young-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.457-468
    • /
    • 2016
  • Traffic-related air pollutants and particulates from diesel exhaust cause for increasing respiratory health problem. Recent epidemiologic studies have reported adverse effects of urban air pollution on various aspects of respiratory health. Bus or truck terminal workers have high probability of exposure to diesel exhaust particle than general office worker. This study was designed to evaluate the relationship between pulmonary function of people who working at the high-density area of diesel vehicles and pulmonary function of people who working at general office in Seoul. So, this study explored the effects on people with exposure to diesel traffic or exposure to diesel traffic, through the pulmonary function test (PFT). There were significant difference in Forced Vital Capacity (FVC) and Forced Expiratory Volume in 1 second ($FEV_1$) between high-exposure group and control. High-exposure to diesel particle were increased risk of reduction in pulmonary function in this study. These results provide the necessity additional research that manage people who working at the high-density area of diesel vehicles.

Visualizing Construction Process Linking Process Simulation (프로세스 시뮬레이션을 연계한 건설공정 시각화)

  • Kim, Yeong-Hwan;Jung, Pyung-Ki;Seo, Jong-Won
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.1 s.29
    • /
    • pp.73-79
    • /
    • 2006
  • Even though graphical simulation is very useful for construction planning, the application of graphical simulation has a limitation in dealing with objects without fixed form like earthmoving process. In this case, the mathematical/statistical simulation about the productivity of the whole processes based on the numerical data of working time, waiting time and working capacity of using equipment becomes effective. The mathematical/statistical simulation is not fully utilized in the field of construction due to the difficulties of creating process models and securing trust the numerically expressed results of simulation. In this research, the output of discrete-event simulation programs which are the most common mathematical/statistical simulation tool for construction processes were analyzed for the purpose of earthmoving process visualization. The purpose of this research is to develop a graphical simulation system that can help the construction planner select most suitable equipment and construction methods through the visualize the numerical simulation results of the working time, the queuing time as well as the amount resources etc.

A Study on the Convective Heat Transfer in a Regenerative Ice Energy System by a Bundle of the Heat-pipes. (히이트파이프 다발을 이용한 냉축열시스템에서의 대류열전달에 관한 연구)

  • 권형정;김경석;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.57-66
    • /
    • 1990
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air conditioning systems are being operated during daytime in summer season, which inevitably entails the construction of an additional electric power plant. This study is aimed to carry out a basic experiment for the development of a cooling air conditioning system using the ice energy by the surplus electric power during the night-time. The experimental apparatus consists of four major parts; (1) the heating section consisting of the air duct and I.D. fan, (2) the cold section with the ice chamber, (3) the bundle of heat pipes made in a form of the staggered arrangement with ${C_y}/{d_o}$=2.0 and ${C_x}/{d_o}$=1.73, (4) the refrigerator system to cool down the ice chamber. This study involves an intensive experiment concerning the convective heat transfer of the air flow surrounding the bundle of heat pipes. This major experimental parameters are the amount of working fluid, the velocity of air and the working temperature. The major findings of the present study are as follows; (1) The optimum amount of the working fluid necessary for the horizontal heat pipes is much more than that for the vertical type. (2) The convective heat transfer coefficients of the air are coincided with the empirical equations of Grimson and ${\breve{Z}ukauskas}$. (3) The equation of the mean heat transfer coefficient obtained in the present study is ${N_um}=0.32 {Re_max^{0.63}}$.

  • PDF

The performance comparison of vapor-vapor ejector OTEC system using wet refrigerants (습냉매를 적용한 증기-증기 이젝터용 OTEC 시스템의 성능비교)

  • Yoon, Jung-In;Son, Chang-Hyo;Kim, Young-Bok;Ye, Byung Hyo;Ha, Su-Jeong;Lee, Ho-Saeng;Kim, Hyeon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.51-56
    • /
    • 2014
  • In this paper, OTEC(Ocean Thermal Energy Conversion) system with vapor-vapor ejector is newly proposed. And 6 wet refrigerants are applied into the proposed OTEC system for performance comparison. The results of comparison performance are as follows. In the view of system efficiency, R32/R744(90:10) has the highest efficiency among the 6 refrigerants. In case of evaporation capacity, pump work and mass flow rate of working fluid, R744, R717 and R717 is lowest value, respectively. As this results, the vapor-vapor ejector is able to increase the efficiency of system. And It is necessary to select the optimized working fluid considering environmental and economic factors.

Desorption characteristics of Activated Carbon and Activated Carbon Fiber by Development of Sorbent Tube for Measurement of Organic Solvent (유기용제 측정용 흡착관 개발을 위한 AC 및 ACF의 흡착특성)

  • 원정일;김기환;신창섭
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.99-109
    • /
    • 2002
  • Charcoal $tube/CS_2$ method are more popularly used than any other in the measurement of the working environment for the exposure evaluation of organic solvent, but it is some weak points that the lower accuracy can be obtained on the polar materials and within the range of the low concentration. Thus solvent desorption method has been developed to make accuracy higher and to overcome some weak points. However, because of high price of adsorption tube for thermal desorption and the short of study on its application to the working environment, it is not popularly used in the domestic industrial hygiene fields. This dissertation aims to develop thermal desorption and adsorption tubes for measuring organic solvents in the working environment, by comparing and analyzing breakthrough condition and adsorption capacity with ACF. Specific surface area of ACF used in this study is wider than the one of AC and micropore of ACF related with adsorption has been developed, and adsorption velocity and adsorption amount are very excellent by linking a pore of surface and an inside well into micropore. 1. Result of analysis on physical characteristics of adsorbent, the specific surface area of ACF was 1.3 times higher than that of AC. Distribution ratio of micropore related to adsorption was 94% on ACF and AC. Result of SEM, micropore of the AC is opened to the surface. In contrast, ACF shows that extremely fast adsorption speed. Because of micropore are exposed on the surface and penetrate through each other. 2. Breakthrough characteristics of adsorbents was not different from slop of breakthrough curve. The effluent concentration reaches 10% of initial concentration($C_{out}/C_{in}=0.1$, break point) of ACF was 30~316min longer than that of AC. Therefore, the adsorption capacities of ACF was 1.1~4.6 times higher than that of AC. ACF can be used as a proper adsorbent for measurement of organic solvent.