• Title/Summary/Keyword: Worker Detection

Search Result 102, Processing Time 0.024 seconds

Derivatization and Residual Determination of MCPP in Soil Leachate (토양 침투수중 MCPP의 유도체화 및 잔류분석)

  • Hong, Moo-Ki;Smith, Albert E.
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.199-208
    • /
    • 1994
  • Analytical methods for the determination of the derivatives of the herbicide (${\pm}$)-2-(4-chloro-2-methylphenoxy)propionic acid (MCPP) by capillary column gas chromatography with mass spectrometer (GC-MS) and electron-capture detection (GC-ECD) were studied. A successful procedure was introduced for the ester preparation using $H_2SO_4$, as the catalyst and the alcohol 2,2,2-trichloroethanol (TCE) or 2,2,2-trifluoroethanol (TFE). The identificaiton and elucidation of MCPP by GC-MS spectrometry following the esterification with diazomethane, $BF_3$/methanol, $H_2SO_4$/methanol, TCE, TFE, or pentafluorobenzyl bromide (PFB) were carried out. A comparison of the response-sensitivities among those MCPP esters was made with GC-ECD. Although the methylation product of MCPP was confirmed by GC-MS, its low sensitivity to the ECD limited the detection of MCPP. TCE, TFE, and PFB derivatization methods resulted in a high rate of MCPP esterifications and very sensitive ECD molecular responses. Based on efficiency, convenience, worker safety, and least sample contamination, TFE esterificaiton was considered as the superior method for MCPP analysis to the other methods of derivatization. An accurate method is described for quantifying MCPP in soil leachates by GC-ECD at very low concentrations without the requirement of a complicated clean-up process. As a result, MCPP residues at concentrations of less than $0.1{\mu}g$ in 100ml soil leachate were detected.

  • PDF

Implementation of Constructor-Oriented Visualization System for Occluded Construction via Mobile Augmented-Reality (모바일 증강현실을 이용한 작업자 중심의 폐색된 건축물 시각화 시스템 개발)

  • Kim, Tae-Ho;Kim, Kyung-Ho;Han, Yunsang;Lee, Seok-Han;Choi, Jong-Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.55-68
    • /
    • 2014
  • Some infrastructure these days is usually constructed under the ground for it to not interfere the foot-traffic of pedestrians, and thus, it is difficult to visually confirm the accurate location of the site where the establishments must be buried. These technical difficulties increase the magnitude of the problems that could arise from over-reliance on the experience of the worker or a mere blueprint. Such problems include exposure to flood and collapse. This paper proposes a constructor-oriented visualization system via mobile gadgets in general construction sites with occluded structures. This proposal is consisted with three stages. First, "Stage of detecting manhole and extracting features" detects and extracts the basis point of occluded structures which is unoccluded manhole. Next, "Stage of tracking features" tracks down the extracted features in the previous stage. Lastly, "Stage of visualizing occluded constructions" analyzes and synthesizes the GPS data and 3D objects obtained from mobile gadgets in the previous stages. This proposal implemented ideal method through parallel analysis of manhole detection, feature extraction, and tracking techniques in indoor environment, and confirmed the possibility through occluded water-pipe augmentation in real environment. Also, it offers a practical constructor-oriented environment derived from the augmented 3D results of occluded water-pipings.

Preparation of Styrene-Ethyl acylate Core-shell Structured Detection Materials for aMeasurement of the Wall Contamination by Emulsion Polymerization

  • Hwang, Ho-Sang;Seo, Bum-Kyoung;Lee, Dong-Gyu;Lee, Kune-Woo
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.84-85
    • /
    • 2009
  • New approaches for detecting, preventing and remedying environmental damage are important for protection of the environment. Procedures must be developed and implemented to reduce the amount of waste produced in chemical processes, to detect the presence and/or concentration of contaminants and decontaminate fouled environments. Contamination can be classified into three general types: airborne, surface and structural. The most dangerous type is airborne contamination, because of the opportunity for inhalation and ingestion. The second most dangerous type is surface contamination. Surface contamination can be transferred to workers by casual contact and if disturbed can easily be made airborne. The decontamination of the surface in the nuclear facilities has been widely studied with particular emphasis on small and large surfaces. The amount of wastes being produced during decommissioning of nuclear facilities is much higher than the total wastes cumulated during operation. And, the process of decommissioning has a strong possibility of personal's exposure and emission to environment of the radioactive contaminants, requiring through monitoring and estimation of radiation and radioactivity. So, it is important to monitor the radioactive contamination level of the nuclear facilities for the determination of the decontamination method, the establishment of the decommissioning planning, and the worker's safety. But it is very difficult to measure the surface contamination of the floor and wall in the highly contaminated facilities. In this study, the poly(styrene-ethyl acrylate) [poly(St-EA)] core-shell composite polymer for measurement of the radioactive contamination was synthesized by the method of emulsion polymerization. The morphology of the poly(St-EA) composite emulsion particle was core-shell structure, with polystyrene (PS)as the core and poly(ethyl acrylate) (PEA) as the shell. Core-shell polymers of styrene (St)/ethyl acrylate (EA) pair were prepared by sequential emulsion polymerization in the presence of sodium dodecyl sulfate (SOS) as an emulsifier using ammonium persulfate (APS) as an initiator. The polymer was made by impregnating organic scintillators, 2,5-diphenyloxazole (PPO) and 1,4-bis[5-phenyl-2-oxazol]benzene (POPOP). Related tests and analysis confirmed the success in synthesis of composite polymer. The products are characterized by IT-IR spectroscopy, TGA that were used, respectively, to show the structure, the thermal stability of the prepared polymer. Two-phase particles with a core-shell structure were obtained in experiments where the estimated glass transition temperature and the morphologies of emulsion particles. Radiation pollution level the detection about under using examined the beta rays. The morphology of the poly(St-EA) composite polymer synthesized by the method of emulsion polymerization was a core-shell structure, as shown in Fig. 1. Core-shell materials consist of a core structural domain covered by a shell domain. Clearly, the entire surface of PS core was covered by PEA. The inner region was a PS core and the outer region was a PEA shell. The particle size distribution showed similar in the range 350-360 nm.

  • PDF

A Qualitative Study on Intervening Work Experiences of Hospital-Based Child Protection Team on Child Abuse Death Cases (병원 학대피해아동보호팀의 아동학대 사망사건 개입경험 연구)

  • Kim, Kyunghee;Lee, Heeyoun;Chung, Ickjoong;Kim, Jihae;Kim, Sewon
    • Korean Journal of Social Welfare
    • /
    • v.65 no.4
    • /
    • pp.61-88
    • /
    • 2013
  • The aim of this study was to explore the work experiences of hospital-based child protection team staffs who had intervened the child abuse cases resulting in death. In order to gather the relevant data, all 62 child protection teams registered nationwide were contacted and 5 teams which had actually experienced at least one child abuse deaths were found. The staffs (hospital social workers and doctors) who belonged to these teams were intensively interviewed, and the interviewed materials were thoroughly analyzed by qualitative research methodology. The result showed that treatment delay was the most important obstacle to prevent unnecessary deaths of the victims. Some abused victims were sent to the hospital only after their physical condition had so gravely deteriorated. In other cases, custodians' bland denial or refusal to treatment made impossible the timely intervention to save the child lives. Nevertheless, child protection team staffs' reasonable suspicion and active intervention could sometimes uncover the hidden truth that child abuse was the actual cause of death. These incidents were regarded as a team's meaningful accomplishments by team members. Meanwhile, lack of awareness and excessive burden about the role and responsibility of mandated reporter precluded medical staffs' active involvement. Also, substantiating the abuse suspicion by securing positive evidences was found to be a facilitatory factor for the rapid public intervention. On the basis of these results, several practice and policy implications were discussed to improve the early detection process, securing evidence and uncovering the actual cause of death in child abuse deaths.

  • PDF

A Baseline Study on the Choice of Optimal Screening Test Items among Workers with Abnormal Liver Function Tests on Workers' Periodic Health Examination (근로자 건강진단시 간기능 이상자의 정밀검사항목 개선을 위한 조사연구)

  • Cheong, Hae-Kwan;Lim, Hyun-Sul;Kim, Gyu-Hoi
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.4 s.48
    • /
    • pp.747-761
    • /
    • 1994
  • Workers' periodic health examination is the main tools used to manage the health problems of most workers in Korea. The most common health problem found in workers' periodic health examination is liver disorder. Liver disorder is also one of the most common health problems in general population and one of the leading causes of mortality in adult population. Regulation proposed by government (No. 207, Ministry of Labor, 1992) defines the criteria for selection of workers with the liver dysfunction for further evaluative examination and the examination items used for diagnosis of the workers with liver dysfunction. This study was designed to evaluate the proficiency of each examination items presently defined in Regulation and propose the optimal examination items for detection of the liver disorders found by workers' periodic health examination. Study subjects are 186 workers with abnormal liver function tests in screening examination of workers' periodic health examination. Questionnaire survey including past history of liver disorder, drinking history, height and weight was done. Physical examination by physician, routine test items defined by Regulation (SGOT, SGPT, $\gamma$-GTP, protein, albumin, total and direct bilirubin, alkaline phosphatase, $\alpha$-feto protein, HBsAg and anti-HBs), anti-HCV antibody test and liver ultrasonography were done. Results are as follows; 1. Result of evaluative examination utilizing only the items defined in Regulation was; There were 75 workers with suspected live. disorder(40.3%), 63 with no liver dysfunction (33.9%), 13 with suspected hepatitis B(7.0%), 10 workers with hepatitis B(5.4%), 10 workers with hepatitis B carrier state(5.4%), 10 with alcoholic liver disorders(5.4%), 5 with fatty liver(2.7%). When alternative diagnostic criteria applying additional examination items (drinking history, body mass index, anti-HCV antibody and ultrasonography) diagnosability of liver disorder was increased. When all four items were included, final results were; 23 workers (17.8%) with hepatitis B (10 carriers, 13 suspects and 10 hepatitis B), 10 (5.4%) with hepatitis C(4 carriers, 5 suspects and 1 hepatitis C), 13(7.0%) with alcoholic liver disorder, 45(24.2%) with fatty liver (40 suspects, 5 fatty liver), 410%) with suspected liver disorders and 44 (23.7%) with normal liver. 2. Of examination items defined by Regulation, only SGOT, SGPT, $\gamma$-GTP and HBsAg were significantly different in abnormal rate and mean value, and all other laboratory findings did not showed significant difference between two groups. Drinking history, body mass index and anti-HCV antibody test which are the items that authors included in this study, also showed significant difference between two groups. Utilization of body mass index (BMI) for abnormal liver function group in diagnosis of fatty liver had high specificity (97.6%) but sensitivity (22.3%) was low. Therefore we suggest that SGOT, SGPT, $\gamma$-GTP, HBsAg, alcohol drinking history, BMI and anti-HCV Ab were useful for diagnosis of liver disorders among worker's periodic health examination.

  • PDF

Fabrication and estimation of the plastic detector for measuring the contamination for beta-ray level of the kind of duct waste (배관류 폐기물의 베타선 오염도 측정용 플라스틱 검출기 제작 및 특성평가)

  • Kim Gye-Hong;Oh Won-Zin;Lee Kune-Woo;Seo Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.159-165
    • /
    • 2005
  • The characterization of radiological contamination inside pipes generated during the decommission of a nuclear facility is necessary before pipes can be recycled or disposed. But, existing direct measurements of radioactive contamination level using the survey-meter can not estimate the characteristic of contamination on a local area such as the pipe inside. Moreover, the measurement of surface contamination level using the indirect methods has many problems of an application because of the difficulty of collecting sample and contamination possibility of a worker when collecting sample. In this work, plastic scintillator was simulated by using Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. In addition, the problem of scintillator processing and transferring the detector into the pipe inside was considered when fabricating the plastic detector on the basis of simulation results. The characteristic of detector fabricated was also estimated. As a result, it was confirmed that detector capability was suitable for the measurement of contamination level. Also, the development of a detector for estimating the radiological characteristic of contamination on a local area such as the pipe inside was proven to be feasible.

  • PDF

Analysis on Urinary N-methylformamide of Korean Workers according to Industrial Classification and Countermeasures for Exposure Control of N,N-dimethylformamide (우리나라 근로자들의 업종별 뇨중 N-methylformamide 분석 및 N,N-dimethylformamide 노출관리 대책)

  • Kim, Dohyung;Byun, Kiwhan;Park, Jae-Oh;Lee, Mi-Young;Kim, Eun-A
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.345-352
    • /
    • 2014
  • Objectives: This study is aimed to describe the current situation about urinary biomarker N-methylformamide(NMF) for workers exposed to N,N-dimethylformamide(DMF) according to industrial classification. Materials: Special health examination records of the workers who had undergone urinary biological monitoring in 2013 were collected. The numbers and percentage of workers, whose urinary NMF values were above the limit of detection(LOD) and above the biological exposure index(BEI) were calculated. Health relatedness with DMF as judged by their doctors was also described. All description was classified according to the $9^{th}$ Korean Standard Industrial Classification(KSIC). Results: It appeared that most workers exposed to DMF belong to manufacturing section(80.7%). The geometric mean(GM) values of urinary NMF were 6.25 mg/L, 3.54, and 3.86 for the manufacturing section, professional, scientific and technical activities section, and for the construction section respectively. In detail, it seemed that division of textiles(except apparel) (GM 7.51 mg/L), division of leather, luggage and footwear(11.59 mg/L), and division of rubber and plastic products(6.89 mg/L) were highly exposed to DMF with a high percentage of workers with urinary NMF values above BEI. This was probably due to the effect of skin absorption that the division of leather, luggage and footwear showed the highest urine NMF GM. Conclusions: It seemed that workers in manufacture industries such as textile, leather, luggage, footwear, rubber and plastic products were highly exposed to DMF. So, efforts should be focused on those industries in order to effectively diminish worker's exposure. Further studies to compare DMF air-monitoring with bio-monitoring according to industrial classification should be considered.

A Study on Urinary N-acetyl-$\beta$-D-glucosaminidase Activities of Office Workers in a Certain Industrial Complex Area (모 공단지역 사무직 근로자들의 요중 N-acetyl-$\beta$-D-glucosaminidase 역가에 관한 연구)

  • Kim, Hwa-Sung;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.547-556
    • /
    • 1994
  • In order to identify the necessary information of biochemical Indices for renal effect of lead for the early detection in medical surveillance of lead worker, the reference values of urinary N-acetyl-$\beta$-D-glucosaminidase (NAG) activities were studied with 205 office workers in one industrial complex area who were not exposed to lead occupationally. While study variables selected for lead exposure were blood lead (PbB), blood zinc protoporphyrin(ZPP) and $\delta$-aminolevulinic acid (DALA) in urine, those for renal effect were urinary N-acetyl-$\beta$-D-glucosaminidase (NAG), blood urea nitrogen (BUN), serum creatinine(Cr), serum uric acid (Ua), and urinary total protein(U-TP). The results obtained were as follows: 1. The mean values of blood lead, ZPP and DALA in all subjects were $14.39{\pm}4.02{\mu}g/dl,\;21.61{\pm}8.00{\mu}g/dl,\;and\;2.73{\pm}0.90mg/l$ respectively. 2. The mean value of urinary NAG activities in all subjects was $3.51{\pm}2.01U/l$. The mean value of urinary NAG activities, which calculated from NAG activities divided by urinary creatinine concentration (CNAG), was $5.42{\pm}5.53U/g$ creatinine and log-arithmic normal distributed. 3. The reference value of urinary NAG activity was 12.06 U/g creatinine(95% CU=10.57-14.76 U/g creatinine). 4. Logarithmic CNAG(r=0.781 p<0.0l), U-TP(r=0.670 p<0.01) and ZPP(r=0.172 p<0.05) showed statistically significant correlation with CNAG.

  • PDF

Development of an Imaging Based Gang Protection System

  • Grimm, M.;Pelz, M.
    • International Journal of Railway
    • /
    • v.1 no.4
    • /
    • pp.149-156
    • /
    • 2008
  • During maintenance or construction works in or at the tracks of railways, high risks for passengers and railway staff, especially for the workers on the construction site exist. The high risks result out of the movement of rail vehicles, like trains or construction vehicles, which must be faced by using any available technical and operational technologies for securing them against the environment. Therefore, it is necessary to evaluate the level of protection continuously and to identify new and innovative methods and technologies for the protection of the gang (construction worker, machines and material). Especially on construction sites at line sections with two or more parallel tracks but also with single tracks, there are still a lot of incidents and accidents mostly with seriously injured persons or fatalities. These were mainly gang members that breach the railway-loading gage. By using proper warning or protection systems, the avoidance of such accidents must be achieved. The latest developments. in gang protection systems concern on the one hand fixed barriers in the middle between the construction site and the operated track and on the other hand construction vehicles equipped with automatic warning systems. The disadvantage of such protection methods is that the gang can be warned against an approaching train but a monitoring of the gang members cannot be performed. Only one part of a potential dangerous situation will be detected. If the gang members will overhear the acoustic warning signal of the security staff and the workers will not leave the danger zone in the track, the driver of the approaching train had no chance to react to the dangerous situation. An accident is often inevitable. While the detection of acoustic warning signals by the gang members working on a construction site is very difficult, the acoustical planning of an automatic warning system has to be designed for an acoustic short range level of one meter besides the construction vehicle. The decision about the use of today's technical warning system (fixed systems, automatic warning systems, etc.) must be geared to the technical feasibility and the level of safety which is needed. Criteria for decision guidance to block a track should be developed by danger estimation and economical variables. To realize the actual jurisdiction and to minimize the hazards of railway operations by the use of construction vehicles near the tracks further developments are needed. This means, that the warning systems have to be enhanced to systems for protection, which monitor the realization of the warning signal as a precondition for giving a movement authority to a train. This method can protect against accidents caused by predictable wrongdoing. The actual state of the art technique of using a collective warning combined with additional security staff is no longer acceptable. Therefore, the Institute of Transportation System of the German Aerospace Center in Braunschweig (Germany) will develop a gang warning and protection system based upon imaging methods, with optical sensors such as video in visible and invisible ranges, radar, laser, and other. The advantage of such a system based on the possibility to monitor both the gang itself and the railway-loading gauge either of the parallel track or of the same track still in use. By monitoring both situations, the system will be able to generate a warning message for the approaching train, that there are obstacles in the track, so that the train can be stopped to prevent an accident. And also the gang workers will be warned, while they breach their area.

  • PDF

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) via Public Facilities PM2.5, Korea (II)

  • Kim, Ho-Hyun;Lee, Geon-Woo;Yang, Ji-Yeon;Jeon, Jun-Min;Lee, Woo-Seok;Lim, Jung-Yun;Lee, Han-Seul;Gwak, Yoon-Kyung;Shin, Dong-Chun;Lim, Young-Wook
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.35-47
    • /
    • 2014
  • The purpose of the study is to evaluate the pollution level (gaseous and particle phase) in the public facilities for the PAHs, non-regulated materials, forecast the risk level by the health risk assessment (HRA) and propose the guideline level. PAH assessments through sampling of particulate matter of diameter < 2.5 ${\mu}m$ ($PM_{2.5}$). The user and worker exposure scenario for the PAHs consists of 24-hour exposure scenario (WIES) assuming the worst case and the normal exposure scenario (MIES) based on the survey. This study investigated 20 PAH substances selected out of 32 substances known to be carcinogenic or potentially carcinogenic. The risk assessment applies major toxic equivalency factor (TEF) proposed from existing studies and estaimates individual Excess Cancer Risk (ECR). The study assesses the fine dusts ($PM_{2.5}$) and the exposure levels of the gaseous and particle PAH materials for 6 spots in each 8 facility, e.g. underground subway stations, child-care facilities, elderly care facilities, super market, indoor parking lot, terminal waiting room, internet caf$\acute{e}$ (PC-rooms), movie theater. For internet caf$\acute{e}$ (PC-rooms) in particular, that marks the highest $PM_{2.5}$ concentration and the average concentration of 10 spots (2 spots for each cafe) is 73.3 ${\mu}g/m^3$ (range: 6.8-185.2 ${\mu}g/m^3$). The high level of $PM_{2.5}$ seen in internet cafes was likely due to indoor smoking in most cases. For the gaseous PAHs, the detection frequency for 4-5 rings shows high and the elements with 6 rings shows low frequency. For the particle PAHs, the detection frequency for 2-3 rings shows low and the elements with 6 rings show high frequency. As a result, it is investigated that the most important PAHs are the naphthalene, acenaphthene and phenanthrene from the study of Kim et al. (2013) and this annual study. The health risk assessment demonstrates that each facility shows the level of $10^{-6}-10^{-4}$. Considering standards and local source of pollution levels, it is judged that the management standard of the benzo (a)pyrene, one of the PAHs, shall be managed with the range of 0.5-1.2 $ng/m^3$. Smoking and ventilation were considered as the most important PAHs exposure associated with public facility $PM_{2.5}$. This study only estimated for inhalation health risk of PAHs and focused on the associated cancer risk, while multiple measurements would be necessary for public health and policy.