• Title/Summary/Keyword: Work Load

Search Result 1,967, Processing Time 0.041 seconds

Analysis of Microbiological Contamination in Cultivation and Distribution Stage of Melon

  • Park, Kyeong-Hun;Yun, Hye-Jeong;Kim, Won-Il;Kang, Jun-Won;Millner, Patricia D.;Micallef, Shirley A.;Kim, Byeong-Seok
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.6
    • /
    • pp.615-622
    • /
    • 2013
  • The purpose of this study was to evaluate microbial contamination of melons in Korea. A total of 123 samples including melon fruits, leaves, seeds, soils, and irrigation water were collected from farms and markets to detect total aerobic bacteria, coliform, Escherichia coli, and pathogenic bacteria such as Bacillus cereus, Listeria monocytogenes, Salmonella spp., and Staphylococcus aureus. Samples were collected from Iksan and Nonsan farms to monitor bacterial levels on pre-market melons. The total aerobic and coliform bacteria on melon cultivation were between 0.43 and 6.65 log CFU $g^{-1}$, and 0.67 and 2.91 log CFU $g^{-1}$, respectively. Bacillus cereus, a fecal coliform, was detected in soils and melon leaves from Iksan farm at 2.95, 0.73 log CFU $g^{-1}$, respectively, and in soils from Nonsan farm at 3.16 log CFU $g^{-1}$. Market melon samples were collected to assay bacterial load on melon being sold to consumers. The contamination levels of total aerobic bacteria in agricultural markets, big-box retailers, and traditional markets were 4.82, 3.94, 3.99 log CFU $g^{-1}$, respectively. The numbers of coliform in melon on the markets ranged from 0.09 to 0.49 log CFU $g^{-1}$. Listeria monocytogenes, Salmonella spp., and Staphylococcus aureus were not detected in any samples. The count of total aerobic bacteria on melon seeds ranged from 0.33 to 3.34 log CFU $g^{-1}$. This study found that irrigation water, soil, manure and various farm work activities including post-harvest processes were latent sources of microbial contamination. These results suggest that hygienic management and monitoring of soil, water, and agricultural material should be performed to reduce microbial contamination in melon production.

Studies on Working Intensity in Felling Operation of the Thinning Forest -In Thinning of Some Conifer Species- (벌채작업(伐採作業)에서의 작업강도(作業强度) 측정연구(測定硏究) -침엽수(針葉樹) 간벌림에(間伐林)서-)

  • Park, Soo-Kyoo;Kang, Gun-Uh
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.3
    • /
    • pp.396-408
    • /
    • 1996
  • The purposes of this study were to standardise the forest working system to design the intensity of working system in felling operation of the thinning forest in our country as well as to contrive the improvement of working method and the increase of productivity. For the purpose of investigating these, element working was classified by felling operation in softwood thinning forest, and a pulse rate were measured and analyzed. The results were as follow : 1. From the analysis of the pulse frequence measurment, the average pulse showed 108 pulse per minute for worker A in the total of pure working time, 130 pulse per minutes for worker B, 119 pulse per minute for worker C and 125 pulse per minute for worker D, respectively. 2. From the results of the pulse frequence analysis according to element working classification, the highest pulse frequence represented 115 pulse per minute for worker A in the circumference, 131 pulse per minute for worker B in the movement, 122 pulse per minute for worker C in the limbing operation and 128 pulse per minute for work D in hang-up. 3. If the original pulse frequence was 100% for workers, the working intensity showed as follow : worker A was 160%(original pulse frequence was 61=100%) for the total of the working intensity and 188% for the circumference among element working. Worker B was 220%(original pulse frequence was 57=100%) for the total of the working intensity and 229 for movement among element working. Worker C was 159%(original pulse frequence was 73=100%) for the total of the working intensity and 168% for limbing operation among the element working. Worker D was 156%(original pulse frequence was 70=100%) for the total of working intensity and 182% for hang-up among element working. 4. At the limit point of Labor performance rating, showing the total of working intensity, overtime pulse rate per minute was 30 for worker A, 207 for worker B, 14 for worker C and 67 for worker D. Worker B was highest in working intensity, and got physically a big load.

  • PDF

Development of Robotic Inspection System over Bridge Superstructure (교량 상판 하부 안전점검 로봇개발)

  • Nam Soon-Sung;Jang Jung-Whan;Yang Kyung-Taek
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.180-185
    • /
    • 2003
  • The increase of traffic over a bridge has been emerged as one of the most severe problems in view of bridge maintenance, since the load effect caused by the vehicle passage over the bridge has brought out a long-term damage to bridge structure, and it is nearly impossible to maintain operational serviceability of bridge to user's satisfactory level without any concern on bridge maintenance at the phase of completion. Moreover, bridge maintenance operation should be performed by regular inspection over the bridge to prevent structural malfunction or unexpected accidents front breaking out by monitoring on cracks or deformations during service. Therefore, technical breakthrough related to this uninterested field of bridge maintenance leading the public to the turning point of recognition is desperately needed. This study has the aim of development on automated inspection system to lower surface of bridge superstructures to replace the conventional system of bridge inspection with the naked eye, where the monitoring staff is directly on board to refractive or other type of maintenance .vehicles, with which it is expected that we can solve the problems essentially where the results of inspection are varied to change with subjective manlier from monitoring staff, increase stabilities in safety during the inspection, and make contribution to construct data base by providing objective and quantitative data and materials through image processing method over data captured by cameras. By this system it is also expected that objective estimation over the right time of maintenance and reinforcement work will lead enormous decrease in maintenance cost.

  • PDF

A study on the effect of tunnelling to adjacent single piles and pile groups considering the transverse distance of pile tips from the tunnel (말뚝의 횡방향 이격거리를 고려한 터널굴착이 인접 단독말뚝 및 군말뚝에 미치는 영향에 대한 연구)

  • Jeon, Young-Jin;Kim, Sung-Hee;Lee, Cheol-Ju
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.6
    • /
    • pp.637-652
    • /
    • 2015
  • In the present work, a number of three-dimensional (3D) parametric numerical analyses have been carried out to study the influence of tunnelling on the behaviour of adjacent piles considering the transverse distance of the pile tip from the tunnel. Single piles and $5{\times}5$ piles inside a group with a spacing of 2.5d were considered, where d is the pile diameter. In the numerical modelling, several key issues, such as the tunnelling-induced pile settlements, the interface shear stresses, the relative shear displacements, the axial pile forces, the apparent factors of safety and zone of influence have been rigorously analysed. It has been found that when the piles are inside the influence zone, the pile head settlements are increased up to about 111% compared to those computed from the Greenfield condition. Larger pile settlements and smaller axial pile forces are induced on the piles inside the pile groups than those computed from the single piles since the piles responded as a block with the surrounding ground. Also tensile pile forces are induced associated with the upward resisting skin friction at the upper part of pile and the downward acting skin friction at the lower part of pile. On the contrary, when the piles were outside the influence zone, tunnelling-induced compressive pile forces developed. Based on computed load and displacement relation of the pile, the apparent factor of safety of the piles was reduced up to about 45%. Therefore the serviceability of the piles may be substantially reduced. The pile behaviour, when considering the single piles and the pile groups with regards to the influence zone, has been analysed by considering the key features in great details.

Evaluation of Worker's Health and Occupational Exposure to Perchloroethylene in Laundries (Perchlotoethylene을 사용하는 세탁소 작업자들의 직업성 폭로와 건강에 관한 연구)

  • An, Sun-Hee;Lee, Jong-Hwoa;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.224-239
    • /
    • 1994
  • In this study we examined several subjective symptoms in an exposed group and an unexposed group to perchloroethylene. The exposed group consists to 30 workers employed in 23 dry-cleaning establishments located in Chung Cheung Do, whereas the unexposed group consists of 42 officers employed in a certain university. This study was conducted from October, 1993 to March, 1994. Also we investigated personal exposure levels and area concentration of PCE, and performed hematological and biochemical examination in blood and urine samples from the exposed group. The results are : 1. The exposed group highly complains several subjective symptoms, particularly in neuropsychiatry, eye, respiratory system and digestive system, compared with the unexposed group. But complaint rates in the exposed group are not related with PCE exposure levels. 2. PCE exposure levels for all dry-cleaning establishment varied widely, from 0.18 to 37.58ppm. The mean exposure level for centers of chain was 16.85ppm, and for local laundries was 8.83ppm, while for self-service establishment it was 3.07ppm. Eighty three percent of the workers were exposed less than the half-level(25.0ppm) of the Korea 50.0ppm standard for eight-hour PCE exposure. Seventeen percent of them exceeded the half-level of the Korea TLV. 3. Statistical correlation exists between the work load(number of operation cycles of equipment and the mass of processed textiles) and the personal exposure levels to be observed. 4. In hematological examination the values of WBC, RBC, Hgb, Hct, MCV, MCH, MCHC and PLT in the exposed group were within normal ranges. In biochemical examination(GOT, GPT, ALP, U-A and LDH) most of the items were within normal ranges. From this surveys conducted on 23 dry-cleaning establishments, the complaint rates of the exposed group to PCE in several subjective symptoms were higher than those of the unexposed group, and PCE exposure levels in all dry-cleaning establishment were below the Koera standard 50.0ppm. In hematological and biochemical examination the significant abnormalities by occupational exposure to PCE were not observed. However, the workers employed in dry-cleaning establishments are always faced with risk, becauses they are also exposed to several organic solvents used to remove stains. Therefore, various measures to improve occupational environment in dry-cleaning establishment should be considered.

  • PDF

Data Mining and Construction of Database Concerning Effects of Vitis Genus (산머루 관련 정보수집 및 데이터베이스의 구축)

  • Kim, Min-A;Jo, Yun-Ju;Shin, Jee-Young;Shin, Min-Kyu;Bae, Hyun-Su;Hong, Moo-Chang;Kim, Yang-Seok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.4
    • /
    • pp.551-556
    • /
    • 2012
  • The database for the oriental medicine had been existed in documentation in past times and it has been developed to the database type for random accesses in the information society. However, the aspects of the database are not so diversified and the database for the bio herbal material exists in widened type dictionary style. It is a situation that the database which handles the in-depth raw herbal medicines is not sufficient in its quantity and quality. Korean wild grape is a deciduous plant categorized into the Vitaceae and it was found experimentally that it has various medical effects. It is one of the medical materials with higher potentiality of academic study and commercialization recently because it has a bigger possibility to be applied into diverse industrial fields including the medical product for health, food and beauty. We constituted the cooperative system among the Muju cluster business group for Korean mountain wild grapes, Physiology Laboratory in Kyung Hee University Oriental Medicine and Medical Classics Laboratory in Kyung Hee University Oriental Medicine with a view to focusing on such potentiality and a database for Korean wild grapes was made a touchstone for establishing the in-depth database for the single bio medical materials. First of all, the literatures based on the North East Asia in ancient times had been categorized into the classical literature (Korean literature published by government organization, Korean classical literature, Chinese classical literature and classical literature fro Korean and Chinese oriental medicine) and modern literature (Modern literature for oriental medicine, modern literature for domestic and foreign herbal medicine) to cover the eastern and western research records and writings related to Korean wild grapes and the text-mining work has been performed through the cooperation system with the Medical Classics Laboratory in Kyung Hee University Oriental Medicine. First of all, the data for the experiment and theory for Korean wild grape were collected for the Medline database controlled by the Parliament Library of USA to arrange the domestic and foreign theses with topic for Korean wild grapes and the network hyperlink function and down load function were mounted for self-thesis searching function and active view based on the collected data. The thesis searching function provides various auxiliary functions and the searching is available according to the diverse searching/queries such as the name of sub species of Korean wild grape, the logical intersection index for the active ingredients, efficacy and elements. It was constituted for the researchers who design the Korean wild grape study to design of easier experiment. In addition, the data related to the patents for Korean wild grape which were collected from European Patent Office in response to the commercialization possibility and the system available for searching and view was established in the same viewpoint. Perl was used for the query programming and MS-SQL for database establishment and management in the designing of this database. Currently, the data is available for free use and the address is as follows. http://163.180.41.43:8011/index.html

Early Response of Cardiopulmonary Exercise Test(CPET) in Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Radiation (방사선 치료 후 폐암환자의 운동부하 심.폐 기능의 초기변화)

  • Shin, Kyeong-Cheol;Lee, Deok-Hee;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • Background : Patients with locally advanced non-small cell lung cancer are often treated with radiation alone or in combination with chemotherapy. Both modalities have a potentially damaging effect on pulmonary function. In order to examine changes in the cardiopulmonary exercise function of patients with locally advanced non-small cell lung cancer before and after conventional radiotherapy, we conducted a prospective study involving patients with such cancer, that had received radiation therapy. Method : Resting pulmonary function test, thoracic radiographic finding and cardiopulmonary exercise test(CPET) were assessed prior to and 4 weeks following radiation therapy in 11 male patients with locally advanced non-small cell lung cancer. Patient with endobronchial mass were excluded. Results : The forces vital capacity (FVC), forced expiratory volume in 1 second ($FEV_1$ and maximal voluntary ventilation (MVV) did not decreased between before and 4 weeks after radiation but the diffusing capacity (DLCO) had decreased by 11% 4 weeks after radiation, which was not statistically significant. No changes in maximal oxygen consumption ($VO_2$max), carbon dioxide production ($VCO_2$), exercise time and work load were attributed to radiation therapy. Follow up cardiopulmonary exercise testing revealed unchanged cardiovascular function, ventilatory function and gas exchange. No difference in cardiopulmonary exercise test performance was observed between pre- and post-radiation. Conclusion : Cardiopulmonary exercise function did not decrease within the short-term after the radiation of patients with locally advanced non-small cell lung cancer.

  • PDF

Preparation of guidance documents item by item for one-step evaluation and approval for Medical Devices (의료기기 일괄허가 및 기술문서 심사를 위한 품목별 길라잡이 개발)

  • Kim, Yong-Woo;Shin, Chae-Min;Bang, Ji-Young;Yi, Jung-Yeon;Oh, Hyeon-Joo;Bae, Woo-Jin;Choi, Jin-Man;Lim, Kyung-Mi;Oh, Heon-Jin;Kim, Mi-Young;Hur, Chan-Hoi;Kim, Hyung-Bum;Choi, Min-Yong;Kwak, Ji-Young;Kim, Su-Yeon;Hwang, Sang-Yeon;Youn, Hae-Suk;Hong, Hye-Kyeong;Ahn, So-Young;Lee, Chang-Hyung;Jeong, Jin-Baek;Koo, Ja-Jung;Kang, Se-Gu;Jung, Jae-Hoon;Lim, Kyoung-Taek;Lim, Chang-Keun;Kim, Min-Su;Lee, Seong-Hyi;Lee, Jae-Keun;Park, Ki-Jung
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.280-284
    • /
    • 2010
  • Approvals of medical device increase every year as industry of medical device grows. Therefore KFDA keeps trying to improve approval systems. However, the firms of medical device are in trouble due to regulation amendment, a firm of small size, exchange of the person in charge. The staffs of KFDA increase their work load because applicants of approval of medical device aren't used to writing of document. Therefore the firm of medical device in business have a long term. KFDA develops eight guidance document item by item for one-step evaluation and approval for Medical Devices because applicants of approval of medical device write documents easily. KFDA reviewer can carry on quick reviewing in use of this eight guidances. This guidance are improved on satisfaction of applicants of approval of medical device.

Effect of fire - retardant treatment and redrying on the mechanical properties of radiata pine (내화처리(耐火處理) 및 재건조(再乾操)가 라디에타소나무의 역학적(力學的) 성질(性質)에 미치는 영향(影響))

  • Chung, Doo-Jin;Jo, Jae-Sung;Yun, Ki-Eon;Kim, Jae-Jin;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 1999
  • The effect of fire-retardant treatment and redrying on the mechanical properties of radiata pine sapwood were evaluated. Small, clear specimens were treated with three different fire-retardant(FR) chemicals, borax-boric acid(BRX), minalith(MIN), and pyresote(PYR), with target retentions of 30 and 60kg/$m^3$, and then redried at maximum dry-bulb temperature of $25^{\circ}C$, $60^{\circ}C$, $80^{\circ}C$ or $110^{\circ}C$. Each specimen, including untreated and water-treated controls, was tested in static bending and in compression parallel to grain. The extent of strength reduction was dependent on the type of FR chemicals, retention, and redrying temperature, and a highly significant interaction existed between FR treatment and redrying temperature. Modulus of rupture(MOR) and work to maximum load(WML) were significantly decreased by FR treatment and redrying. None of three FR chemicals adversely affect modulus of elasticity (MOE) and maximum crushing strength(MCS). MOE of BRX treatment and MCS of both BRX and PYR treatment increased significantly compared to untreated controls. No significant differences existed between retention levels except for MOE and MCS of some combinations of FR chemicals and redrying temperatures. Although MOE and MCS was not significantly affected by any of the redrying temperatures, these properties were generally decreased with the increase in redrying temperature. The significant reduction in MOR and WML was observed in BRX treatment when dried at temperatures of $60^{\circ}C$ and above, and in MIN and PYR treatment when dried at temperatures of $80^{\circ}C$ and above. Consequently, BRX-treated radiata pine should not be redried at temperatures >$60^{\circ}C$, and MIN- and PYR-treated radiata pine should not be redried at temperatures > $80^{\circ}C$ where bending strength and energy-related properties are important design considerations.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.