• Title/Summary/Keyword: With-Corona

Search Result 828, Processing Time 0.043 seconds

Prebreakdown Phenomena of $SF_{6}$ Gas in a Non-uniform Field Disturbed by a Metallic Protrusion

  • Lee, Kyoung-Ok;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.137-141
    • /
    • 1996
  • This paper deals with the prebreakdown phenomena of $SF_{6}$ gap stressed by non-oscillating and oscillating impulse voltages in a strong inhomogeneous field disturbed by a fred needle shaped-protrusion on the earth-side electrode. The breakdown voltage-time characteristics were measured for both positive and negative polarities and over the gas pressure range of 0.1∼0.5 MPa, and the temporal developments of the 77breakdown were observed by a shunt of 50 n. The dependence of the leader stopping time on the gas pressure were obtained. The local field enhancement due to the space charges, which is produced by the streamer corona, has influence with the electrical breakdown of the test gap. The test streamer corona is oxy a necessary condition for the electrical breakdown and the subsequent ionization activities launch the leader at the local field region.

  • PDF

Evaluation of Endothelial Cell Attachment on Polymer Surface (고분자 표면의 혈관내피세포 부착력에 관한 연구)

  • Choi, Jin-Wook;Ryu, Gyu-Ha;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.131-140
    • /
    • 1990
  • To improve antithrombogenicity of polymer that used in vascular graft and artificial organs, seeding of human endothelial cells on the polyurethane was studied. Human endothelial cells were ismlated from human umbilical veins, using type I collagenase, and identified with goat anti vWF antibodies. Human endothilial cell seeding was tried upon the polyurethane which has good mechanical property and resists stresses. The hydrophobic polyurethane surface was changed hydrophilic by corona discharf:e treatment. Surface hydrophilicity was measured with Wilhemly plate method and the goniometer. To evaluate matrix protein adsorption, fibronectin adsorption test was done. To eveluate cell adhesion, human endothelial cell attachment forces were measured rising a perfusion chamber of , ism diamter. Less cells were detached from the hydrophilically treated polyurethane. This showed that corona discharge on the polyurethane could improve matrix adsorption and endothelial cell attachment.

  • PDF

Effects of Hydroxy Silicone Oil on Insulation Properties of Silicone Rubber(1) (Hydroxy Silicone Oil이 실리콘 고무의 절연특성에 미치는 영향(1))

  • 강동필;박효열;안명상;이웅재;이후범;오세호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.11
    • /
    • pp.1001-1007
    • /
    • 2003
  • The silicone fluids have been generally used as processing agent in silicone rubber(SIR) compounding. The addition of hydroxy silicone (HS) fluids to SIR for insulator housing material is required to meet the good electrical performance and the good processability. In this study, SIR with HS fluids was evaluated to investigate how the kinds of them affect insulation properties. The contact angle of the virgin sample of 40-HS SIR was low and its recovery rate was also slow. The recovery rate of 50-HS SIR was the highest being decreased with the viscosity increase of HS fluids. The tracking resistances and the corona aging resistance of 70-HS SIR and 1,040-HS SIR were excellent Tracking resistance depended largely on heat resistance of silicone fluids. But arc resistance didn't depend merely on the kind of silicone fluids.

Numerical Simulation of Corona Streamer Using Adaptive Mesh Generation and FEM-FCT Method (적응요소분할기법과 FEM-FCT를 이용한 코로나 스트리머 해석)

  • Min, Woong-Gee;Kim, Hyeong-Seok;Lee, Seok-Hyun;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2044-2046
    • /
    • 1999
  • In this paper, the propagation of corona streamer was simulated using finite element method(FEM) combined with Flux-Corrected Transport(FCT) algorithm. To obtain more effective grid distribution, the adaptive mesh generation scheme was also employed. The employed adaptive scheme can refine the mesh where needed. In addition, it is possible to coarsen the unnecessarily dense mesh. Two models were analyzed with proposed method. And the results are shown.

  • PDF

Study on UV degradation in Polymeric Insulating Materials for Use in Outdoor Insulators by Corona-Charging (코로나 대전을 통한 옥외용 고분자 절연재료의 자외선 열화특성 연구)

  • Youn, Bok-Hee;An, Jong-Sik;Lee, Sang-Yong;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.106-109
    • /
    • 2001
  • In this paper, we have investigated the degradation of shed materials of outdoor insulators by UV-radiation by using corona-charging and XPS analysis. The accumulated charges on polymeric surface having intrinsic hydrophobic property have a negative impact on retaining its hydrophobicity. Therefore, shorter decay times of surface charges are preferred. The surface voltage decay on UV-treated silicone rubber and EPDM show a different decay trend with UV treated time. From the XPS analysis, the oxidized groups of silica-like structure in silicone rubber increase with UV treatment time. For EPDM, the oxidized carbon groups of C=O, O=C-O increase as elapse of UV radiation time. These oxidized surface for each material have different electrostatic characteristics, so deposited charges may be expected to have different impacts on their surface hydrophobicity. The degradation mechanism based on our results is discussed.

  • PDF

Analysis of Electric Field Distribution of High Voltage Polymeric Bushing with Structure (초고압 폴리머 부싱의 구조에 따른 전계분포 해석)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Kang, Hyung-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.489-490
    • /
    • 2008
  • This paper describes the analysis of electric field distribution of high voltage polymeric bushing with structure. The high voltage bushing consists of FRP tube and housing made of LSR. The field control can be achieved by means of the design of such internal field shaper and top corona ring as grading electrodes. In accordance, the optimized design uses both internal and external elements for electric stress grading at critical parts of the bushing. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymeric bushing.

  • PDF

Characteristics of Ultrasonic Signals by Partial Discharge Types (변압기내 부분방전의 종류에 따른 초음파 신호 특성)

  • Park, Hyun-Soo;Park, Jae-Do;Chung, Young-Ki;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1897-1899
    • /
    • 2000
  • This paper describes the frequency characteristics and the number of pulse of ultrasonic signals due to partial discharge occurred at each electrode. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC(b) electrode and void electrode. As a result, the dominant frequency of ultrasonic signals generated by corona in oil and partial discharge in void was hardly changed regardless with the applied voltage, but in case of surface discharge in oil, its dominant frequency moved to low frequency with the applied voltage. The increasing rate of pulse number per second was high in order of the surface discharge in oil, the partial discharge in void, the corona in oil.

  • PDF

A Study on the Collection Characteristics of a Wide Plate-Spacing Electrostatic Precipitator -II. Effect of Wave Form of Pulse Energization - (광폭 전기집진기의 집진특성에 판한 연구 - II. 펄스 하전 파형의 영향 -)

  • 김용진;하병길;정상현;홍원석;하대홍;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1059-1064
    • /
    • 2001
  • This study Investigates the effect of the wave form of pulse energization on the collection characteristics of a wide plate spacing electrostatic precipitator. For the semi-pulse energization, the peak current and voltage of the energization increases with increase of the pulse period, and the corona current increases, as pulse ratio decreases. For the micro-pulse energization, the corona current increases with increase of the pulse voltage. The collection efficiency of semi-pulse and micro-pulse energization is larger than that of DC charge.

  • PDF

The Characteristics of Potential Decay on the Corona Electrified Composite Insulating Material by Surface Condition (코로나 대전된 복합절연재료의 표면상태가 전위감쇠에 미치는 영향)

  • 황명환;정재희;조한구;송진호;이덕출
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.65-69
    • /
    • 1997
  • Especially, Fiber glass Reinforced Plastics(FRP) is the best composite insulating material which has been so far. Therefore, it's worthy of notice to investigate on the corona electrified composite insulating material by surface condition. And then some other materials will be focussed on. In this study, charge decay were measured with charging-time and grid voltage on FRP composite material surface in order to analyze the mechanism. As a result we have studied that the way of the composite glass fiber(GF) and Polymer and the condition of the contaminated surface was different. In case of the GF is mixed with vertical, charge decay speed is fast because the charge is easily leaked. On the other hand, the surface charge decay speed is depend on conductive or insulated of the contaminant.

  • PDF

Case Study on the Electrostatic Hazards in the Coating Mechanical System (도장설비에서의 정전기 재해 사례 연구)

  • Kim, Gil-Tae;Jung, Young-Man;Lee, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.602-606
    • /
    • 2006
  • The electrostatic is well known phenomena. The fires and explosions caused by electrostatic occur often in the coating mechanical system. This paper presents various cases of electrostatic hazards, reasons why electrostatic hazards are happened, and methods for preventing electrostatic hazards. Generally the electrostatic can be lead to corona discharging, streaming electrification, and impinging electrification in the coating process. Corona discharging happens at electrostatic spray gun with 70 kV. Streaming electrification occurs at mixing process between paint and thinner, and transportation process with thinner. Impinging electrification is shown when the thinner are sprayed to drums. For the purpose of preventing the electrostatic discharge and damage, conductors should be ground, surface electric potential of should be decreased in using electrostatic shielding and ground, and flow of thinner should be controlled acceptable velocity.

  • PDF