• Title/Summary/Keyword: Wiring operation

Search Result 66, Processing Time 0.02 seconds

Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

A Study on Grounding Technology for the Reduction of Electric Surge in IBS Building (IBS 빌딩에서의 서어지 저감을 위한 접지방안 연구)

  • 박중양;김학련;최규형
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.87-92
    • /
    • 2003
  • According to the realization of highly information dependent society, the recent building system is developed into the concept of suitable for management of intellegent work, which is demanded to unify of IBS(Intelligent Building System), IC(information communication), OA(office automation), BA(building automation) system and computer technology. However inspite of the presence arrester, cable shielding, insulated TR, filter, earth etc., in the IBS building for the cope with several surge and noise has several problems from the wrong operation of the equipment which caused from several surge, damage of equipment, and noise etc. And the miss operation caused by wrong earth works, which must be considered at first during the building construction. In order to minimize these problems, it's necessary that various earth project are performed effectively, and bonding methods between the mutual wiring of earth system and the equipments in the building should be improved sucessively. So in this paper, we analyze present domestic conditions of the earth technology in IBS building, and propose minimization method for the various surge and noise problem, and examine and analyze through the applied works.

  • PDF

Achilles Tendon Rupture Associated with Ipsilateral Bimalleolar Fracture (A Case Report) (아킬레스건 파열과 동반된 동측 족관절 양과 골절(1예 보고))

  • Chung, Hyung-Jin;Bae, Su-Young;Min, Byoung-Kwon;Song, Min-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.107-109
    • /
    • 2011
  • We report here on a case of Achilles tendon rupture associated with ipsilateral bimalleolar fracture that was caused by ski injury. The association of an ankle fracture with rupture of the Achilles tendon is even more infrequent, although both injuries alone are extremely common. We treated as a operation of Achilles tendon repair with Krackow method and open reduction with Tension-band wiring technique for bimalleolar fracture.

Home Automation System based on Ubiquitous (유비쿼터스 기반의 홈 오토메이션)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3039-3042
    • /
    • 2009
  • Home automation system is a demo which is capable of remote monitoring and control on PDA device (which was) programming used by LabVIEW PDA module in embedded system. Every operation program is composed of LabVIEW. And each embedded system is made of self-operating mode without any wiring of PC. This home automation system is controlled by LabVIEW of PDA through Wireless LAN(802.11b).

Analysis of the Earth Resistance for the Tower Footing of T/L (송전선로 철탑기초의 접지저항 해석)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.344-346
    • /
    • 2001
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. During a fault on any of the transmission lines, energization of the earth by supporting structures near the fault can result in large voltages appearing locally between the earth and the steel wall of any nearby pipeline. This paper presents the outline of the tower footings for the transmission lines having been used in KEPCO and analyzes the earth resistance for operation method of the tower footing, that is contact presence for the anchor and reinforcing rob of the tower and foundation presence of the underground wiring.

  • PDF

A study of Voltage Dmp in Electrical Wiring System for Railway Vehicles (철도 차량 배선의 전압강하에 대한 고찰)

  • Son, Min-Kyu;Jung, Ho-Young;Park, Du-Man
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.959-965
    • /
    • 2009
  • To meet the demand increasing passengers in railway vehicles, railway transportation service companies are increasing the numbers of cars per train-set. Two solutions, Variable train-set formations and Multiple train-set operation, are common way to increase the transportation capability. These kind of long distance train-set can effect train-set command and control system, and sometimes the digital signals using train line from master cabin can not reach to the systems located the other extremity slave car. This is so called Voltage Drop. This phenomenon is originated from the electrical power consumption and electrical cable resistance, and cause to the equipments or cars located end of the electrical cable way, malfunction or abnormal operations. This voltage drop happens not only in train lines but also Battery Power Lines. The purpose of this investigation is to design high reliability railway vehicles by clarifying the possibility of happening these events case by case, by analyzing the reasons, and finally by finding the best solutions.

  • PDF

A Two-Step Micromirror for Low Voltage Operation

  • Hwang Yong-Ha;Han Seungoh;Lee Byung-Kab;Kim Jae-Soon;Pak James Jungho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.270-275
    • /
    • 2005
  • In order for the application of the in-vivo endoscopic biopsy, a micromirror which can be driven at a low voltage is required. In this paper, a two-step micromirror composed of bottom electrodes, moving plate and top mirror plate is proposed. Because an electrical wiring of two plates are separated, they can be actuated separately. Therefore, an intermediate moving plate plays an important role in reducing the driving voltage in half. The designed device was fabricated by the surface micromachining. Maximum rotation angle of $6.3^{\circ}$ was obtained by applying DC 48V, while a conventional one-step mirror pulled down at DC 120V. The designed structure can be used in microphotonic applications requiring low driving voltage.

Phase Shift Analysis and Phase Identification for Distribution System with 3-Phase Unbalanced Constant Current Loads

  • Byun, Hee-Jung;Shon, Sugoog
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.729-736
    • /
    • 2013
  • Power grids are large complicated networks in use around. An absolute phase value for a particular unknown-phase line at a local site should be identified for the operation and management of a 3-phase distribution network. The phase shift for a specific point in the line, as compared with a phase reference point at a substation, must be within a range of ${\pm}60^{\circ}$ for correct identification. However, the phase shift at a particular point can fluctuate depending on the line constants, transformer wiring method, line length, and line amperage, etc. Conducted in this study is a theoretical formulation for the determination of phase at a specific point in the line, Simulink modeling, and analysis for a distribution network. In particular, through evaluating the effects of unbalanced current loads, the limitations of the present phase identification methods are described.

Diagnosis Engineering of Grounding System to Reduce Noise Signals (노이즈 저감을 위한 접지시스템 진단 엔지니어링)

  • Cho, Dae-Hoon;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1290-1294
    • /
    • 2016
  • In this study, we investigate the sources of system malfunctions by measuring and diagnosing various surges and noise signals from grounding systems for electrical and electronic systems and installations in order to ensure the reliability and stability of the system operations. We measured performance or structural problems detected in the grounding systems currently in operation and analyzed the measured data in order to eliminate noise currents and interferences causing the systems to malfunction and be damaged. Based on the analysis results, we proposed improving grounding systems and the wiring arrangements most appropriate for the grounding systems and carried out the installations as per the proposed engineering. We verified that the proposed engineering made the status of system operations improved by measuring the ground noise signals during the system operations and comparing them before and after improvements being carried out.

A Study on the wiring Control Method of Hand & Auto Operation of an easy Elevator (간이 승강기 수.자동 배선제어방식에 관한 연구)

  • Wee, Sung-Dong;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.596-602
    • /
    • 2002
  • An easy elevator for learning originated is opened to compare the existed learning equipment, and it had a high studying efficient that the sequence control circuit can opens and closes with the wire. The structure of equipment to be controlled from the first floor to the fifth floors is demonstrated a constructive apparatus by a lamp atc to express the function of the open-close of the door according to the cage moving with a mechanical actuation of the forward-reverse breaker and the motor of load and a mechanical actuation of hand-operation control components of push-button S/W and L/S and relay etc. These components let connects each other in order to control of the elevator function with the auto program and the designed sequence control circuit. Consequent1y the process of these functions of 1~5steps could operates the cage with an auto program of the elevator and the sequence control circuit. The sequence control circuit is controlled by the step of forward and reverse to follow as that the sensor function of the L/S1~L/S5 let posit with the control switchs of S/W1~S/W5 of PLC testing panel and switchs of S/W1~S/W5 installed on the transparent acryl plate of the frame. In here, improved apparatus is a hand-auto operation combined learning equipment to study the principle and a technique of the originated sequence control circuit and the auto program of PLC.

  • PDF