• 제목/요약/키워드: Wiring

검색결과 524건 처리시간 0.023초

필드버스를 이용한 신호설비 제어 및 감시에 관한 연구 (A study on Control and Monitoring for Signaling system use Fieldbus)

  • 박채영;이준호;김용규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1016-1020
    • /
    • 2005
  • The real-time monitoring and controlling between the interior and the field signaling security devices is a necessity for the train safety in terms of the train operating plan. The type wiring lower the safety level of signaling security device, because too much wiring makes the maintenance more difficult and it might be have a problem of an induction field and contact. It also need high cost. The single network communication(Fieldbus) does not need that much wiring, and the maintenance will be easier. It also guarantee the high level of stability.

  • PDF

차량용 데이터 통신을 위한 네트워크 프로토콜의 평가 (Evaluation of network protocols for automotive data communication)

  • 윤정아;남상운;김기웅;이석
    • 제어로봇시스템학회논문지
    • /
    • 제3권6호
    • /
    • pp.632-638
    • /
    • 1997
  • The growing number of electronic components used in automobiles has given rise to problems concerning the increasing number, size and weight of the wiring harnesses. As an approach to resolve these problems, multiplexed wiring systems using automotive communication protocol such as Controller Area Network(CAN), Advanced PALMNET and J1850 have been developed by many automobile companies. In order to compare these protocols quantitatively, this paper presents the performance evaluation of CAN and Advanced PALMNET via discrete event simulation. Through numerous simulation experiments, several important quantitative performance factors such as the probability of a transmission failure, average system delay(data latency), and throughput have been evaluated.

  • PDF

가요성 알루미늄피 케이블 (MCIF CABLE) 을 적용한 일체형 배선시스템 (IN-FLEX System Using Aluminum Clad Flex Cable (MCIF CABLE))

  • 구경완;전인석;문영재;이병용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.58-60
    • /
    • 2007
  • This paper introduces the IN-FLEX system using aluminum clad flex cable, which is expected to alternate the conventional wiring method, such as, a steel pipe wiring method, and a synthetic resin pipe wiring method. The aluminum clad flex cable has a superior operation characteristics in heat dissipation property, in installation and maintenance facility, flammability, and appearance. Moreover, the IN-FLEX system adopted an easy connection mechanism which enable to reduce the time, hands and expense for the installation and maintenance of the system. Certification tests verifying the superior operation characteristics and reliability of the system using aluminum clad flex cable were carried with standard method in KOLAS certification institute.

  • PDF

THE RECENT TREND OF BUILD-UP PRINTED CIRCUIT BOARD TECHNOLOGIES

  • Takagi, Kiyoshi
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.289-296
    • /
    • 1999
  • The integration of the LSI has been greatly improved and the circuit patters on the LSI are becoming finer line and pitch. The high-density electronic packaging technology is improved. In order to realize the high-density packaging technology, the density of the circuit wiring of the printed circuit boards have also been more dense. The build-up process multilayer printed circuit board technology have a lot of vias, possibilities of the finer conductor wirings and have a freedom of capabilities of wiring design. The build-up process printed circuit boards have the wiring rules which are the pattern width: $100-20\mu\textrm{m}$, the via hole diameter: $100-50\mu\textrm{m}$. There three kinds of build-up processes as far materials and hole drilling. In this paper, the recent technology trends of the build-up printed circuit board technologies are described.

  • PDF

Oblique transnasal wiring canthopexy via Y-V epicanthoplasty for telecanthus correction in a patient with Waardenburg syndrome

  • Choi, Bong Gyu;Kim, Yong-Ha
    • 대한두개안면성형외과학회지
    • /
    • 제20권5호
    • /
    • pp.329-331
    • /
    • 2019
  • Telecanthus is a common symptom accompanied by Waardenburg syndrome, a rare genetic disorder. The optimal surgery for telecanthus correction is still debated. A 28-year-old patient with Waardenburg syndrome underwent transnasal wiring canthopexy using a Y-V epicanthoplasty for telecanthus correction. A Mini-Monoka stent was used to prevent damage to the lacrimal apparatus. The intercanthal distance decreased from 50 mm to 43.2 mm. The easily designed Y-V epicanthoplasty incision provides sufficient operative field for oblique transnasal wiring, which is effective in properly positioning the medial canthal tendon. It has minimal scarring resulting in satisfactory cosmetic outcomes.

Acormegaly의 일예 (Case Report of Acromegaly)

  • 한장술
    • 대한치과의사협회지
    • /
    • 제11권4호
    • /
    • pp.255-256
    • /
    • 1973
  • Twenty three year old soldier, was referred to me because of extreme mandibular prognathism. Eight years before, the patient had become aware of some protrusion of his mandible. Up until this time, his jaws seemed to have been developing normally. The oblique osteotomy of the mandible was performed. Risdon cable wiring was used in the upper and lower jaw in order to immobilize the mandible by intermaxillary wiring. The patient recovered from the operation, and was discharged from the 1st Army Hospital after 6 months with good functional mandibular relationship. The appearance of the patient was greatly improved.

  • PDF

환악 결찰술을 이용한 소아 하악 골절의 보존적 치료: 증례보고 (The conservative treatment of mandibular fracture in a child with circummandibular wiring: case report)

  • 김형모;김태완;송승일;이정근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.145-148
    • /
    • 2010
  • Maxillofacial injuries are less common in children than in adolescents and adults. This lower incidence is a result of the relatively small size of mandible, the resilient nature of the bones, and a relatively protected environment, which distinguish the treatment principles of pediatric mandibular fractures from those of the adult. The bone of child is malleable, so pediatric fractures tend to be less displaced and rarely comminuted. Moreover, high regeneration potential of the wound allows more conservative treatment modalities for the pediatric mandibular fracture. High risk of damaging unerupted tooth bud renders many clinicians to resort to more conservative treatment modality for the reduction of displaced segments. This case report describes two successful treatment cases using the circummandibular wiring which was applicated to the fracture on parasymphysis of mandible. Circummandibular wiring can protect the tooth buds, and there is no need for intermaxillary fixation so that it prevents the possible complications of intermaxillary fixation such as the temporomandibular joint ankylosis and the facial growth disturbances. The acrylic splint was removed after 3 weeks, which showed clinically good union across the fracture line without complications. They showed complete clinical and radiological bone healing with an optimum occlusion.

제 1, 2 경추간 판하철사고정술 없는 후방 경관절 나사못 고정술 및 골유합술 (Posterior C1-2 Transarticular Screw Fixation without C1-2 Sublaminar Wiring in Atlantoaxial Instability)

  • 신용환;황정현;성주경;황성규;함인석;박연묵;김승래
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권11호
    • /
    • pp.1469-1475
    • /
    • 2000
  • Objective : The goal of this study was to evaluate the clinical outcome of the posterior C1-2 transarticular screw fixation without C1-2 sublaminar wiring in atlantoaxial instability. Methods : Between Apr. 1995 and Feb. 2000, we used this technique in treat randomly selected 17 patients (11 men, 6 women) who had atlantoaxial instability. The causes of instability were : type II-A odontoid process fracture(10 cases) ; type II-P odontoid process fracture(1 case) ; Os odontoideum(2 cases) ; transverse ligament laxity due to rheumatoid disease(1 case) ; and, transverse ligament injury without bone fracture(3 cases). All cases were operated with posterior C1-2 transarticular screw fixation with 3.5mm cortical screw and interlaminar iliac graft without sublaminar wire fixation. The mean follow-up period was 28 months(5 to 58 months) and the mean age at the time of operation was 41 years(15 to 68 years). All Patients were allowed to ambulate with Philadelphia neck collar on the first post-operation day. Results : Bony fusion was successfully achieved in all cases demonstrated at 3-month follow-up studies. There was no operative mortality or morbidity. Conclusion : The authors conclude that the posterior transarticular screw fixation without C1-2 sublaminar wiring provide adequate stability with high bony union rate in atlantoaxial instability of various causes.

  • PDF

전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석 (Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact)

  • 김두현;황동규
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

물리적 처리에 의한 폐 컴퓨터 기판으로부터 유가금속의 분리선별 특성 연구 (A Study on the Physical Separation Characteristics of Valuable Metals from the Waste Printed Wiring Boards)

  • 현종영;채용배;정수복
    • 자원리싸이클링
    • /
    • 제11권1호
    • /
    • pp.9-18
    • /
    • 2002
  • 폐 컴퓨터 기판(Printed Wiring Boards, PWBs)은 다양한 종류의 금속 및 합금류, 각종의 유기 및 무기화합물 등으로 구성되어 있다. 따라서 폐 기판에 포함된 유가물을 경제적인 방법으로 분리 회수하면 2차 자원으로써 활용가치가 매우 클 것으로 판단되어, 물리적인 선별기술에 의하여 유가금속을 분리 회수하는 데에 따른 특성 연구를 행하였다. 본 연구에는 폐 컴퓨터 기판에 탑재된 소켓류와 칩류를 탈리한 다음 소켓류, 칩류 및 보드류로 분리하여 각각의 산출물의 특성에 따른 적절한 물리적 분리선별 기술을 적용하였다. 소켓류를 파쇄하여 입자크기를 -2.36 mm/+1.18 mm 범위로 조절한 다음 건식 자력선별을 실시하였을 때, 자성산물의 약 97 wt%가 금속류였다. 칩류의 경우에는 -2.36 mm1+0.15 nun의 크기로 분쇄하고 공기분급 및 건 식 자력선별을 행하여 Fe-Ni 97%, Cu 95%를 각각 회수할 수 있었다. 보드류의 경우에는 금속류가 얇게 프린트 된 상태이기 때문에 가능한 단체분리 효과를 향상시키기 위하여 ball mill로 분쇄하였으며, 공기 분급기에 의한 정밀 분급을 행하여 Cu 77%를 회수할 수 있었다.