• Title/Summary/Keyword: Wireless

Search Result 16,263, Processing Time 0.036 seconds

Data Replicas Relocation Strategy in Mobile Computing System Environment (이동 컴퓨팅 시스템 환경에서 데이터 복제 재배치 기법)

  • Choe, Gang-Hui;Jo, Tae-Nam
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.10
    • /
    • pp.2587-2596
    • /
    • 1999
  • Recently, by the extension of skills like LAN, the wireless telecommunication network and the satelite services make it possible for the mobile computer users to access a database. A method to use the replicated database on a server to get new data without missing any information has been being studied. So far we have used the Static Replica Allocation(SRA) for the replication which is the method of the replication on the server. This method is to replicate the data on the replica server after a moving host is transferred to a cell. Since the network of the SRA is very good, and if there are few moving users, no trouble will happen. But if there is no moving users in a cell, the data will not be shared. Therefore, this paper is about the study of the method of relocation after replicating the data to the cells for the users(User Select Replica Allocation : USRA). We also analyze the access rate and the possibility which are closely related to the moving frequency of the mobile hosts and the numbers of the cells. As a result, We show that the 120% lower access cost and the 40%∼50% gains are achieved from the low mobility

  • PDF

Design and implement of patch type wireless skin temperature measuring system (패치형 무선 피부 온도 측정 시스템의 설계 및 구현)

  • Woo, S.H.;Park, S.Y.;Din, Z. Mohy Ud;Won, C.H.;Lee, J.H.;Park, H.J.;Lee, J.W.;Hong, Y.G.;Suh, J.H.;Youm, Y.G.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.350-360
    • /
    • 2008
  • In every large hospital, nurses must perform simple repetitive tasks such as measuring body temperature. Such tedious work reduces nurses' motivation to provide quality medical care, which is an important element of the medical services provided by a hospital. If a device were available to measure body temperature, nurses could focus on the more important aspects of providing quality medical care to the patients. However, body temperature is generally measured from the throat, anus, tympanum or armpit, where it is difficult to affix a patch type device. In addition, general body temperature measuring points shows moving artifact error; therefore, it is not good point to continually measure the temperature. In this paper, a patch type skin temperature measuring system was developed. To appropriately measure the skin temperature, a thermal transducer was implemented with a thin (0.5 mm) temperature sensor. The system is small and thin ($H6.6{\sim}5.3{\times}L35{\times}W24\;mm$), and weighs only 5 g including a battery, case and circuit; therefore, it is small and light enough to function as a patch type device. Moreover, the system worked for 5 days. To investigate differences between the experimental and conventional thermometer, simple clinical experiments were performed with 17 volunteers, and the result showed some correlation between the implemented system and conventional thermometer (Correlation coefficient = 0.647, P<0.1).

HRV Evaluation under Stress Condition by Using Patch Type Bipolar Heart Activity Monitoring System (패치형 바이폴라 심장활동 모니터링 시스템을 이용한 스트레스 상태의 HRV 평가)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Lee, Kang-Hwi;Choi, Hee-Jung
    • Science of Emotion and Sensibility
    • /
    • v.12 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • In this study, we have developed the patch type HAMS (Heart Activity Monitoring System) which is non-restricted, non-awarable and non-invasive. The module using wireless telecommunication to receive the ECG (electrocardiogram) signal at the computer has mobility which it easily monitors the heart activity of subjects in no time for long term at any time and places. We developed the small patch type electrode which can be attached on the chest. Also the reliability and moving artifact of ECG signal measured by this electrode have been verified. Using HAMS, we measured the HRV (Heart Rate Variability) parameters, the questionnaire evaluation for anxiety and stress and the amount of stress hormone (cotisol) to evaluate the stress effect in HRV on the same subject. As a result of comparing the values under non stressed and stressed condition, there was significant difference on many parameters. And the parameter highly related with stress on Pearson's Correlation Coefficient has been examined. These show that using HAMS is able to evaluate the function of autonomic nervous system. Therefore, we can predict heart problem in daily life by using HAMS. Also we expect that this module can be applied for more application as health monitoring system.

  • PDF

In vitro evaluation of nano zinc oxide (nZnO) on mitigation of gaseous emissions

  • Sarker, Niloy Chandra;Keomanivong, Faithe;Borhan, Md.;Rahman, Shafiqur;Swanson, Kendall
    • Journal of Animal Science and Technology
    • /
    • v.60 no.11
    • /
    • pp.27.1-27.8
    • /
    • 2018
  • Background: Enteric methane ($CH_4$) accounts for about 70% of total $CH_4$ emissions from the ruminant animals. Researchers are exploring ways to mitigate enteric $CH_4$ emissions from ruminants. Recently, nano zinc oxide (nZnO) has shown potential in reducing $CH_4$ and hydrogen sulfide ($H_2S$) production from the liquid manure under anaerobic storage conditions. Four different levels of nZnO and two types of feed were mixed with rumen fluid to investigate the efficacy of nZnO in mitigating gaseous production. Methods: All experiments with four replicates were conducted in batches in 250 mL glass bottles paired with the ANKOM$^{RF}$ wireless gas production monitoring system. Gas production was monitored continuously for 72 h at a constant temperature of $39{\pm}1^{\circ}C$ in a water bath. Headspace gas samples were collected using gas-tight syringes from the Tedlar bags connected to the glass bottles and analyzed for greenhouse gases ($CH_4$ and carbon dioxide-$CO_2$) and $H_2S$ concentrations. $CH_4$ and $CO_2$ gas concentrations were analyzed using an SRI-8610 Gas Chromatograph and $H_2S$ concentrations were measured using a Jerome 631X meter. At the same time, substrate (i.e. mixed rumen fluid+ NP treatment+ feed composite) samples were collected from the glass bottles at the beginning and at the end of an experiment for bacterial counts, and volatile fatty acids (VFAs) analysis. Results: Compared to the control treatment the $H_2S$ and GHGs concentration reduction after 72 h of the tested nZnO levels varied between 4.89 to 53.65%. Additionally, 0.47 to 22.21% microbial population reduction was observed from the applied nZnO treatments. Application of nZnO at a rate of $1000{\mu}g\;g^{-1}$ have exhibited the highest amount of concentration reductions for all three gases and microbial population. Conclusion: Results suggest that both 500 and $1000{\mu}g\;g^{-1}$ nZnO application levels have the potential to reduce GHG and $H_2S$ concentrations.

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

Development of the High_frequency and Low_strain Vibration Stimulation System for Stimulating Bone (고주파 저스트레인 골자극 인가용 진동 시스템 개발)

  • Yoo, Ju-Yeon;Park, Guen-Chul;Jeon, Ah-Young;Kim, Yun-Jin;Ro, Jung-Hoon;Jeon, Gye-Rok
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.177-184
    • /
    • 2011
  • In this study, the system for application of the bone stimulation was implemented using high frequency and low strain method. The whole system consists of the high frequency and low strain vibration stimulation system 177 for stimulating bone, LVDT sensor, and wireless sensor based on tri-axial accelerometer. To evaluate the usefulness of the system, the frequencies and accelerations from function generator were applied to the vibration stimulation system. The range of frequency was 17 Hz, 30 Hz, 45 Hz, 50 Hz and the range of acceleration was set 0.3 g, 0.6 g, 1g, and 2 g. The measured frequencies and acceleration using LVDT (linear variable difference transformer) sensor and 3-axial accelerometer were estimated and compared. The range of frequencies average difference was from 0.0 to 0.004 Hz. As the standard deviation of frequencies estimated by LVDT sensor and accelerometer was below 0.03 Hz and the output frequencies of function generator were similar: Also the results of t-test were satisfied with conditions of p > 0.05. And the acquired frequencies and acceleration from vibration measuring device module were estimated and analyzed. As the mean of accelerations was similar to the acceleration applied from function generator. And the standard deviation of acceleration estimated from vibration measuring device module was ranged from 0.019 g to 0.038 g. Also the results of t-test were satisfied with conditions of p > 0.05. Therefore, these results were airy similar to the acceleration applied from function generator. As a result, the usefulness of the system was confirmed. n a further study, clinical experiment will be carried out with the authorization of IRB (institutional review board) so that appropriate frequency and strain would be investigated in clinical field.

A study on analysis model for real radio spectrum data correlation in High-Mountain Area (고지대에서의 전파도달범위 분석을 위한 실측 데이터 기반 전파도달 상관관계 분석모델 연구)

  • Han, In-Sung;Sohn, Ju-Hang;Park, Moo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.697-708
    • /
    • 2016
  • As the needs for fast wireless communication technology in various fields, including companies, individuals, etc., grows, many research projects related to the coverage of propagation are being carried out for plaining optimized communication services. On the other hand, there are some limitations in surveying and analyzing propagation in highland areas. To provide a better communication service of a new service, a range of radio environment conditions based on a wide radio bandwidth (selection of propagation model, correction of value in accordance with radio bandwidth, etc.) should be considered. In particular, radio environment conditions are becoming increasingly sophisticated. By the early detection of real-time changes in the radio spectrum, which is based on an examination and research of regional occupied band width condition, proper measures should be established. To make a proper solution of above, the basic real-time analysis of spectrum distribution status by regional groups is necessary. In addition, the establishment of prompt measures should be enable by stored or analyzed radio data. In an attempt to predict reliable propagation coverage, this thesis examines the limited propagation data with HTZ Warfare, which were collected from domestic high land sites faced with limited access. Furthermore, a comparative result value evaluation for an optimized propagation model was performed through testing simulations, and frequency-dependent and propagation model-dependent analysis.

Design of the Flexible Buffer Node Technique to Adjust the Insertion/Search Cost in Historical Index (과거 위치 색인에서 입력/검색 비용 조정을 위한 가변 버퍼 노드 기법 설계)

  • Jung, Young-Jin;Ahn, Bu-Young;Lee, Yang-Koo;Lee, Dong-Gyu;Ryu, Keun-Ho
    • The KIPS Transactions:PartD
    • /
    • v.18D no.4
    • /
    • pp.225-236
    • /
    • 2011
  • Various applications of LBS (Location Based Services) are being developed to provide the customized service depending on user's location with progress of wireless communication technology and miniaturization of personalized device. To effectively process an amount of vehicles' location data, LBS requires the techniques such as vehicle observation, data communication, data insertion and search, and user query processing. In this paper, we propose the historical location index, GIP-FB (Group Insertion tree with Flexible Buffer Node) and the flexible buffer node technique to adjust the cost of data insertion and search. the designed GIP+ based index employs the buffer node and the projection storage to cut the cost of insertion and search. Besides, it adjusts the cost of insertion and search by changing the number of line segments of the buffer node with user defined time interval. In the experiment, the buffer node size influences the performance of GIP-FB by changing the number of non-leaf node of the index. the proposed flexible buffer node is used to adjust the performance of the historical location index depending on the applications of LBS.

An Implementation of Mobile Platform using Location Data Index Techniques (위치 데이터 인덱스 기법을 적용한 모바일 플랫폼구현)

  • Park, Chang-Hee;Kang, Jin-Suk;Sung, Mee-Young;Park, Jong-Song;Kim, Jang-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.11
    • /
    • pp.1960-1972
    • /
    • 2006
  • In this thesis, GPS and the electronic mapping were used to realize such a system by recognizing license plate numbers and identifying the location of objects that move at synchronous times with simulated movement in the electronic map. As well, throughout the study, a camera attached to a PDA, one of the mobile devices, automatically recognized and confirmed acquired license plate numbers from the front and back of each cu. Using this mobile technique in a wireless network searches for specific plate numbers and information about the location of the car is transmitted to a remote sewer. The use of such a GPS-based system allows for the measurement of topography and the effective acquisition of a car's location. The information is then transmitted to a central controlling center and stored as text to be reproduced later in the form of diagrams. Getting positional information through GPS and using image-processing with a PDA makes it possible to estimate the correct information of a car's location and to transmit the specific information of the car to a control center simultaneously, so that the center will get information such as type of the cu, possibility of the defects that a car might have, and possibly to offer help with those functions. Such information can establish a mobile system that can recognize and accurately trace the location of cars.

Design and Implementation of Picture Archiving and Communication System Component using the RFID for Mobile Web Environments (모바일 웹 환경을 위한 의료영상저장전송시스템 컴포넌트의 설계 및 구현)

  • Kim Chang-Soo;Yim Jae-Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.6
    • /
    • pp.1124-1131
    • /
    • 2006
  • The recent medical treatment guidelines and the development of information technology make hospitals reduce the expense in surrounding environment and it requires improving the quality of medical treatment of the hospital. Moreover, MIS, PACS(Picture Archiving and Communication System), OCS, EMR are also developing. Medical Information System is evolved toward integration of medical IT and situation is changing with increasing high speed in the ICT convergence. Mobile component refers to construct wireless system of hospital which has constructed in existing environment. Through RFID development in existing system, anyone can log on easily to internet whenever and wherever. It is the core technology to implement automatic medical processing system. This paper provides a basic review of RFID model, PACS application component services. In addition, designed and implemented database server's component program and client program of mobile application that recognized RFID tag and patient data in the ubiquitous environments. This system implemented mobile PACS that performed patient data based db environments, and so reduced delay time of requisition, medical treatment, lab.