• Title/Summary/Keyword: Wire connection part

Search Result 8, Processing Time 0.029 seconds

Development of a 4-axis optical pickup actuator (4 축 광픽업 액추에이터의 개발)

  • Kim, Jae-Eun;Lee, Kyung-Taek;Hong, Sam-Nyol;Ko, Eui-Seok;Seo, Jeong-Kyo;Choi, In-Ho;Min, Byung-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.856-860
    • /
    • 2008
  • Wire-suspensions in the conventional actuators mechanically support the moving part and guarantee the accuracy of the actuator without tangential tilt actuation. However, such a suspension configuration has considerable stiffness in the tangential tilt direction with two additional wire beams for the tangential tilt. Thus, we performed a design sensitivity analysis for the wire-suspension stiffness of 4-axis actuator and controlled the main parameters such as distance among wire-suspensions and wire-suspension length to allow tangential tilt flexibility. The elasticity of frame PCB that supports the moving part by wire-suspensions was also exploited to improve the flexibility of wire-suspension in the tangential tilt direction. A novel suspension structure was devised by establishing eight wire-suspensions at both sides of the moving part for electrical connection to coils. The magnetic circuit according to the proposed 4-axis actuator using multi-polar magnet and coils was also suggested for the generation of electromagnetic forces in the focusing, tracking, radial and tangential tilt directions.

  • PDF

A Study on the Thermal Characteristics of Wire Connection Part Depending on the Screw Torque (나사조임토크에 따른 전선접속부의 열적특성에 관한 연구)

  • Kim, Si-Kuk;Jee, Seung-Wook;Park, Sang-Min;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.82-88
    • /
    • 2012
  • To analyze the thermal characteristics of wire connection part that is connected to a screw-clamping terminal block depending on screw torque, the normal screw torque defined in KS C 2625 and the abnormal screw torque that can occur due to loosened screws resulting from defective work or aged deterioration were used as experimental variables. After the same load was applied to normal and abnormal screw torques, the thermal characteristics of the wire connector were measured and compared with a thermal imaging camera. The findings from this study will be used to detect heating due to defective screw torque at terminal block connections during electric safety inspection in the future and minimize the hazard of electric fire.

Error Wire Locating Technology with Breadth-first Search Algorithm (Breadth-first 검색 알고리즘을 이용한 와이어 오류 검출에 관한 연구)

  • Jian, Xu;Lee, Jeung-Pyo;Lee, Jae-Chul;Kim, Eal-Goo;Park, Jae-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.258-260
    • /
    • 2007
  • Nowadays the automotive circuit design becomes more complicated a practical modern car circuit usually contains thousands of wires. So the error connection between connector and pins becomes more difficult to be located. This paper proposes a general way to locate all error wires in an automotive circuit design. Firstly, we give an exact definition of error wire to guide our job. This definition also composes the core part of our algorithm. Then we limit the area of the error wires by several steps. During these steps, we apply breadth-first search method to step over all wires under consideration of reducing time cost. In addition, we apply bidirectional stack technique to organize the data structure for algorithm optimization. This algorithm can get a result with all error wires and doubtful wires in a very efficient way. The analysis of this algorithm shows that the complexity is linear. We also discuss some possible improvement of this algorithm.

  • PDF

An Experimental Study for the Evaluation of the Structural Behavior Eco Deck Plate (Eco Deck Plate의 구조적 거동 평가를 위한 실험적 연구)

  • Lee, Jin-Eung;Lee, Yong-Jae;Lee, Soo-Kueon;Jung, Byung-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.40-48
    • /
    • 2013
  • Eco deck plate system is a construction method that deconstruction of galvanized steel sheets is possible by integrating steel-wire-integrated girders and the galvanized steel sheets with bolts. Therefore, compared with previous steel-wire-integrated deck plates which were joined by welding, the system is acknowledged as the construction method possible management and repair. This study conducted an experimental research by manufacturing total 24 full size specimens in a same condition for 12-shape specimens by two parts to evaluate structural behaviors of the eco deck plates. In the results after the test, permissible deflection for the construction load action was shown to be values under design values and satisfactory. The processing of lattice steel wires was presented to be structurally advantageous in being manufactured by cutting downward. Also, in case of a specimen that D13 as a steel wire was used, destruction occurred at the welding part of the bottom steel wire and the lattice steel wire, so improvement measures for the welding in factory manufacture are necessary.

Design Concept of Beams Reinforced by Deformed Bars and Non-Prestressed Strands in Combination (비긴장강연선과 철근이 혼용된 보의 설계방안)

  • Noh, Sam-Young;Jo, Min-Joo;Kim, Jong-Sung;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.18-29
    • /
    • 2013
  • A new precast concrete (PC) beam and column connection system using non-prestressed wire strands was recently developed. The system is composed of one unit of two-storied PC-column and PC-beams with U-shaped ends. The connection part of the column and beams is reinforced by deformed bars and non-prestressed wire strands in combination for the improvement of workability. Structural performance of this system was verified by several experimental studies. The purpose of this study is developing a design concept of the beam reinforced by deformed bars and non-prestressed wire strands in combination, in terms of the cross-sectional analysis, based on the preceded experiment. A minimum and maximum reinforcement ratio and the calculation formula for the strength of flexural member reinforced by reinforcements having different yield strengths are derived based on KBC2009. Under consideration existing research results for the application of high strength reinforcement bars, the design yield strength of the non-prestressed wire strand is suggested. An example for the cross section design, satisfying the serviceability requirements, demonstrates the applicability of the design concept developed in the study.

A Study on the Thermal Characteristics Depending on Poor Contact of Wire Connection Part in Terminal Block (단자대 전선접속개소의 접촉불량에 따른 발열특성에 관한 연구)

  • Park, Sang-Min;Jee, Seung-Wook;Kim, Si-Kuk;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.48-51
    • /
    • 2011
  • 본 논문은 나사조임 단자대 내에 접속되는 전선의 접촉불량에 따른 발열특성을 분석하고자 단자대 접속개소의 조임토크를 KS C 2625에서 규정한 정상조임토크와 인위적인 불량조임토크를 변수로 설정하여 조임토크의 크기별로 동일한 부하를 인가한 후, 열화상카메라를 이용하여 접속불량에 따른 발열특성을 비교 분석하였다.

  • PDF

Surface Reconstruction for Cutting Path Generation on VLM-Slicer (VLM-Slicer에서 절단 경로 생성을 위한 측면 형상 복원)

  • Lee, Sang-Ho;An, Dong-Gyu;Yang, Dong-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.71-79
    • /
    • 2002
  • A new rapid prototyping process, Variable Lamination Manufacturing using a 4-axis-controlled hotwire cutter and expandable polystyrene foam sheet as a laminating material of the part (VLM-S), has been developed to reduce building time and to improve the surface finish of parts. The objective of this study is to reconstruct the surface of the original 3D CAD model in order to generate mid-slice data using the advancing front technique. The generation of 3D layers by a 4 axis-controlled hot-wire cutter requires a completely different procedure to generate toolpath data unlike the conventional RP CAD systems. The cutting path data for VLM-S are created by VLM-Slicer, which is a special CAD/CAM software with automatic generation of 3D toolpath. For the conventional sheet type system like LOM, the STL file would be sliced into 2D data only. However, because of using the thick layers and a sloping edge with the firstorder approximation between the top and bottom layers, VLM-Slicer requires surface reconstruction, mid-slice, and the toolpath data generation as well as 2D slicing. Surface reconstruction demands the connection between the two neighboring cross-sectional contours using the triangular facets. VLM-S employs thick layers with finite thickness, so that surface reconstruction is necessary to obtain a sloping angle of a side surface and the point data at a half of the sheet thickness. In the process of the toolpath data generation the surface reconstruction algorithm is expected to minimize the error between the ruled surface and the original parts..

An Experimental Study on the Evaluation of EMP Shielding Performance of Concrete Applied with ATMSM Using Zn-Al Alloy Wire (Zn-Al 합금 선재를 이용한 금속용사 공법 적용 콘크리트의 전자파 차폐 성능 평가에 관한 실험적 연구)

  • Choi, Hyun-Jun;Park, Jin-Ho;Min, Tae-Beom;Jang, Hyun-O;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.3
    • /
    • pp.209-217
    • /
    • 2019
  • EMP (Electromagnetic Pulse) usually means High Power Electromagnetic Wave (HPEM). In the case of the shielding plate against the EMP, there is a possibility of deterioration of the electromagnetic wave shielding performance due to the skill of the constructor, bad construction, deformation of the shielding plate at the connection portion (joint portion). The inefficient use of space due to the separation distance is also pointed out as a problem. Therefore, this study aims to derive the optimum electromagnetic shielding condition by applying ATMSM to concrete as a part of securing electromagnetic wave shielding performance with reflection loss against concrete wall. Experimental parameters included concrete wall thickness and application of Zn-Al ATMSM. For the concrete wall, the wall thickness was 100 to 300mm, which is generally applied, and experimental parameters were set for the application of Zn-Al metal spraying method to evaluate electromagnetic shielding performance. Experimental results showed that as the thickness increases, the electromagnetic shielding performance increases due to the increase of absorption loss. In addition, after the application of Zn-Al ATMSM, the average shielding performance increased by 56.68 dB on average, which is considered to be increased by the reflection loss of the ATMSM. In addition, it is considered that the shielding performance will be better than that when the conductive mixed material and the ATMSM are simultaneously applied.