• Title/Summary/Keyword: Wire Driving

Search Result 97, Processing Time 0.03 seconds

Power Line Communication Heating Control System by LonWorks (LonWorks를 이용한 전력선 통신 난방제어 시스템)

  • Kim, Myung-Ho;Kim, Sun-Boo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1150-1155
    • /
    • 2006
  • In a heating control system, the indoor temperature controller transfers temperature signals inputed from the temperature sensor and the user to the valve controller. The valve controller recieves these signals then the valve controller controls the valve driving motor on two position control and controls the indoor temperature. When setting up a new valve driving motor from a long distance it is necessary to set up a new valve controller. But occasionary, due to construction, it is impossible to wire between the existing valve controller and the new valve controller. In this situation, the new and existing valve controllers can communicate via power line communication. In this paper it is proposed heating control system controls on two position control via power line communication.

  • PDF

Vibration Characteristics of a Wire-Bonding Ultrasonic Horn (와이어 본딩용 초음파 혼의 진동 특성)

  • Kim, Young Woo;Yim, Vit;Han, Daewoong;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.2
    • /
    • pp.227-233
    • /
    • 2014
  • This study investigates the vibration characteristics of a wire-bonding piezoelectric transducer and ultrasonic horn for high-speed and precise welding. A ring-type piezoelectric stack actuator is excited at 136 kHz to vibrate a conical-type horn and capillary system. The nodal lines and amplification ratio of the ultrasonic horn are obtained using a theoretical analysis and FEM simulation. The vibration modes and frequencies close to the driving frequency are identified to evaluate the bonding performance of the current wire-bonder system. The FEM and experimental results show that the current wire-bonder system uses the bending mode of 136 kHz as the principal motion for bonding and that the transverse vibration of the capillary causes the bonding failure. Because the major longitudinal mode exists at 119 kHz, it is recommended that the design of the current wire-bonding system be modified to use the major longitudinal mode at the excitation frequency and to minimize the transverse vibration of capillary in order to improve the bonding performance.

A Study for Detecting Fuel-cut Driving of Vehicle Using GPS (GPS를 이용한 차량 연료차단 관성주행의 감지에 관한 연구)

  • Ko, Kwang-Ho
    • Journal of Digital Convergence
    • /
    • v.17 no.11
    • /
    • pp.207-213
    • /
    • 2019
  • The fuel-cut coast-down driving mode is activated when the acceleration pedal is released with transmission gear engaged, and it's a default function for electronic-controlled engine of vehicles. The fuel economy becomes better because fuel injection stops during fuel-cut driving mode. A fuel-cut detection method is suggested in the study and it's based on the speed, acceleration and road gradient data from GPS sensor. It detects fuel-cut driving mode by comparing calculated acceleration and realtime acceleration value. The one is estimated with driving resistance in the condition of fuel-cut driving and the other is from GPS sensor. The detection accuracy is about 80% when the method is verified with road driving data. The result is estimated with 9,600 data set of vehicle speed, acceleration, fuel consumption and road gradient from test driving on the road of 12km during 16 minutes, and the road slope is rather high. It's easy to detect fuel-cut without injector signal obtained by connecting wire. The detection error is from the fact that the variation range of speed, acceleration and road gradient data, used for road resistance force, is larger than the value of fuel consumption data.

The Spray Behavior Analysis and Space Distribution of Mixture in Transient Jet Impinging on Piston Cavity (비정상 충돌 분류의 Cavity형상에 따른 공간 농도 분포 및 거동해석)

  • Lee, S.S.;Kim, K.M.;Kim, B.G.;Chang, S.S.;Ha, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.1 no.2
    • /
    • pp.16-23
    • /
    • 1996
  • In case of a high-speed D.I. diesel engine. the injected fuel spray is unavoidable that the impinging on the wall of piston cavity and in this case the geometry of piston cavity has a great influence on the atomization structure and air flow fields. In the field of combustion and in many other spray applications, there are clear evidence of correlation between spray structure and emission of pollutants. Ordinary, the combustion chamber of driving engine have unsteady turbulent flow be attendant on such as the change of temperature, velocity and pressure. So the analysis of spray behavior is difficult. In this study, a single spray was impinged on each cavity wall at indicated angle in a quiescent atmosphere at room temperature and pressure, as being the simplest case, and 3 types of piston cavity such as Dish, Toroidal and Re-entrant type was tested for analyzing the influence of cavity geometry. And hot wire probe was used for analyze non-steady flow characteristics of impinging spray, and to investigate the behavior of spray, the aspects of concentration c(t), standard deviation $\sigma(t)$ and variation factor (v.f.) was measured with the lapse of time.

  • PDF

Estimation of Power Collector Wear Considering the Operating Environment of a Maglev (자기부상열차의 주행 환경을 고려한 집전자 마모도 평가)

  • Lee, Kyoung-bok;Ma, Sang-kyeon;Lim, Jae-won;Park, Do-young;Son, Jeong-ryong;Kang, Hyun-il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • The wear of the third track power collector is one of the essential check factors for safe train operation. Rapid wear of the current collector accelerates the line of the catenary. In addition, the arc generated when the catenary line is turned off causes a malfunction in the minute portion of the catenary line, thereby shortening the life of the catenary line. In this paper, to analyze the mechanical wear of the current collector during driving according to the environmental factor of the Maglev(magnetic levitation train), it was divided into dry season and wet season. the wear of metallized collector, copper alloy collector and carbon collector were measured and compared with each other. The wear rate was measured according to the position of the wire, the position of the power collector and the position per hour. Microscopic photographs of the cross section and surface of the power collector were measured. The electrical currents of the metallized collector, copper alloy collector and carbon collector were measured.

The Behavior of Impinging Spray by Piston Cavity Geometry (PistonCavity 형상에 따른 충돌분류의 분무거동)

  • 이상석;김근민;김봉곤;정성식;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.211-219
    • /
    • 1996
  • In a small high-speed D. I. diesel engine, the injected fuel spray into the atmosphere of the high temperature is burnt by go through the process of break up, atomization, evaporation and process of ignition. These process are important to decide the emission control and the rate of fuel consumption and out put of power. Especially, in the case of injected fuel spray impinging on the wall of piston cavity, the geometry of piston cavity gives great influence the ignitability of injected fuel and the flame structure. Ordinary, the combustion chamber of driving engine have unsteady turbulent flow be attendant on such as the change of temperature, velocity and pressure. So the analysis of spray behavior is difficult. In this study, the spray was impinged on the wall of 3 types of piston cavity such as Dish, Toroidal, Re-entrant type, in order to analyze the combustion process of impinging spray precisely and systematically. And hot wire probe was used for analyze non-steady flow characteristics of impinging spray, and to investigate the behavior of spray, the aspects of concentration c(t), standard deviation σ(t) and variation factor(vf) was measured with the lapse of time.

  • PDF

Development of autonomous system using magnetic position meter (자기거리계를 이용한 자율주행시스템의 개발)

  • Kim, Geun-Mo;Ryoo, Young-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.3
    • /
    • pp.343-348
    • /
    • 2007
  • Development of autonomous vehicle system that use magnetic position meter research of intelligence transportation system is progressed worldwide active by fast increase of vehicles. Among them, research about autonomous of vehicles occupies field. And autonomous of vehicles is element that path recognition is basic. Existent magnetic base autonomous system analyzes three-dimensional data of magnet marker to 3 axises magnetic sensor and recognized route. But because using Magnetic Wire and Magnetic Position Meter in treatise that see, measure side lateral error and propose system that driving. And system that compare with system of autonomous vehicles and propose wishes to verify by hardware of that specification and simple algorithm through an experiment that autonomous is available.

Design Parameters of Optical Pickup Actuator for the Next Generation (차세대 광 픽업 구동기를 위한 설계 변수)

  • Han, Chang-Soo;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.1
    • /
    • pp.82-88
    • /
    • 2001
  • The demands of high data transfer rate and high recording density in optical disk memory device are being increased. In this paper, 4 design parameters for next generation optical disk are investigated. As for the high data transfer rate, two design parameters such as driving acceleration and transmissibility are introduced. As the high recording density is concerned, the minimum linearity and the tilt of the actuator are introduced. Two kinds of pickup actuator are used to evaluate the validity of the parameters through the simulation and the experiment. The 4-wire actuator has good linearity but bad stability and tilt characteristics, while the rotary and axis actuator has good stability for the external vibration but bad linearity. It is demonstrated that the newly proposed design parameters are available to design and evaluate quantitatively the performance of the actuator for the next generation optical disk.

  • PDF

The Design of a I/O Circuits for Driving and Monitoring of the Diesel Generator for Emergency (비상용 디젤 발전기 구동 및 모니터링을 위한 입출력 회로 설계)

  • Joo, Jae-Hun;Kim, Jin-Ae;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1491-1496
    • /
    • 2009
  • This paper presents an digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes rick-up coil signal.

Characteristics Analysis of Induction Motor by Operation of Non-linear Loads under the 3-Phase 4-Wire Grid System (3상 4선식에시 비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.54-62
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.