• Title/Summary/Keyword: Windows and doors

Search Result 155, Processing Time 0.03 seconds

A Study on the Attractive Items of Hanok in Urban Area focused on Preceding Studies (선행연구에 나타난 도시한옥의 매력 요소에 관한 연구)

  • Min, Sae-Rom;Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.3
    • /
    • pp.61-68
    • /
    • 2012
  • The purpose of this paper is to derive attractive items of 'Hanok' in order to preserve 'Hanok' in urban area, focused on the 13 preceding studies which have got in respect of image, satisfaction, preference, awareness and advantage of 'Hanok' in urban area revolved around the latest studies. This study is analysis of questionnaire items and results of 13 preceding studies. And attractive items are classified with general and overall survey items, advantage of 'Hanok' in urban area, and image of Hanok-density urban area. These can also be classified with 5 items which are space, health, material, form, and image of 'Hanok' in urban area. As a result, Space items are composed with 'use of a space', 'cosiness', 'garden' and 'floor and ondol(korean floor heating system). Health items are composed with 'lighting and ventialtion', 'a sense of the season' and 'natural material'. Material items are composed with 'natural beauty', 'wooden', 'changhoji(traditional Korean paper made from mulberry bark for doors and windows) and hanji(traditional Korean paper handmade from mulberry trees), 'rafter' and 'new materials'. Form items are composed with 'attractive appearance', 'simply decoration' and 'traditional elements'. Image items are composed with 'crowding', 'traditionality and historicity', 'dichroism' and 'warmth'.

Experimental investigation into infrasound and low-frequency noise radiation characteristics from large wind turbines (중대형 풍력터빈의 저주파 및 초저주파 소음 방사 특성에 대한 실험적 고찰)

  • Lee, Seung-Yub;Cheong, Cheol-Ung;Shin, Su-Hyun;Jung, Sung-Soo;Cheung, Wan-Sup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1482-1489
    • /
    • 2007
  • In this paper, characteristics of infrasound and low-frequency noise emission from large modern wind turbines are experimentally investigated. The sound measurement procedures of IEC 61400-11 and ISO 7196 are utilized to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbines using the stall regulation and the pitch control for the power regulation, respectively. It was found that the G-weighted SPLs of low-frequency noise including infrasound shows positive correlation with the wind speeds, irrespective of methods of power regulation. This highlights the potential complaint of local community against the infrasound and low-frequency noise of wind turbines. The comparison of measured data with the existing hearing thresholds and criteria curves shows that it is highly probable that the low-frequency noise from the 1.5 MW and 660 kW wind turbines in the frequency range over 30 Hz leads to the psychological complaint of ordinary adults, and that the infrasound in the frequency range from 5 Hz to 8 Hz causes the complaint by rattling the house fitting such as doors and windows.

  • PDF

A Basic Study on the Optional Composition for Apartment Housing Design (아파트 단위주호 개발에서 선택사양 구성을 위한 기초연구)

  • Cho, Sung-Heui;Lee, Eun-Joo
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.67-76
    • /
    • 2010
  • The purposes of this study are to understand residents' needs in regard to living space and to suggest how to provide layout options for the infill, based on their needs, so that the residents can change their living space to suit their own need. This study analyzed residents' needs in terms of living spaces through literature reviews on apartment remodeling and related previous studies. The results are as follows: First, the residents remodeled the various infill, and remodeling works are then classified into five infill groups according to the flexible features: 1) structural elements, such as flooring, ceilings, interior walls, and windows/doors; 2) equipment elements, such as lighting and electricity, electrical wiring, heating arrangements, and water supply & drainage systems: 3) finishing material elements, such as finishing materials for floors, walls, and ceilings, skirting boards, moldings, and art walls; 4) furniture elements, such as built-in wardrobes, storage closets, and kitchen cabinets; and 5) bathroom facility elements such as faucets and sinks. Second, based on the remodeling features, four ways to provide options can be suggested. 1) options are provided for each room; 2) options are provided in connection with structural elements; 3) options are provided for each finishing material element; and 4) options are provided with the combinations of different bathroom facilities.

A Study on Problems of High-rise Building Fires in Korea and the Basic Directions for Fire Safety of High-rise Building Design (우리나라 고층건축화재의 문제점과 그 대책의 기본방향에 관한 연구)

  • 이강훈
    • Fire Science and Engineering
    • /
    • v.4 no.2
    • /
    • pp.15-26
    • /
    • 1990
  • Building become higher. larger and more complex than ever before, showing abrupt changes in building structures. forms and mechanical systems. Likewise hazads of fire and the scale of fire losses become more and more greater. Therefore. considerations for fire safety take up great portion of the building design process. In this study, problems of high-rise building fires and basic directions for fire safety of high-rise building design were studied through the statistical analysis of 138 fire cases. The results of this study are summarized as follows : ·Most of the fires in high-rise building occur on the low floors and the fire frequencies are very low on the upper floors. Fire casualties are liable to be more on the upper floors than on tile floor of fire origin. ·The important causes of evacuation failures were analyzed as being late in escape and lack of stairwell enclosures. ·The main cause of vertical fire spread is lack of stairwell enclosures. However, the fire spreads mainly through the enterior windows in apartment houses. The combustible materials in buildings act on as the major factors of horizontal fire spread and the improper fire doors play role of another the critical causes. ·The basic directions for fire safety of high-rise building design put much stress firstly on the compartmentation of the buildings effectively performing the provision of safe escape routes and the safe refuse places in buildings.

  • PDF

A Field Study on the Facilities and Equipments of the Traditional Farmhouse in Lungching, China (중국 연변 조선족 전통농가의 시설설비 실태조사)

  • 고도임
    • Journal of the Korean Home Economics Association
    • /
    • v.36 no.6
    • /
    • pp.123-132
    • /
    • 1998
  • This paper is a part of "The Study of the Traditionla Korean Ethnic Farmhousing in Yanbian, China" The purpose of this study is to investigate the facilities and equipments of the traditional farmhouse in the villages of Lungching China. The data is collected from 124 households in the villages based on the survey conducted using questionnaire and photograph. The major findings are: 1) The people in farmhouse use wood as a fuel for cooking and the method of cooking is traditional style using their iron pots. 2) Heating system of the house is ondol type of heating using. wood which is also traditional type. This means that the floor heating of the house and cooking food can be carried out simultaneously. 3) Even though pump system and running water system are the two kinds of water supply that are available in the villages, majority of people use pump system. Many houses have no drainage facilities but few houses have got bad drainage system. 4) From the planning stage of the farm house facilities and equipments for ventilation is not considered and hence it is not provided in most of the houses. 5) Farmhouses are oriented to the south and the windows and the doors are covered either with viny1 or cloth during winter time effecting the lighting system of the house. 6)Many of the houses use incandescent lights. But the switchs and the electric Outlets are short in number. 7) Sanitation facilities are worst equipped compared to other facilities present in Lungching villages of China. of China.

  • PDF

Development of a Body Network System with GSEK/VDX Standards and CAN Protocol (OSEK/VDX 표준과 CAN 프로토콜을 사용한 차체 네트웍 시스템 개발)

  • 신민석;이우택;선우명호;한석영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.175-180
    • /
    • 2002
  • In order to satisfy the requirements of time reduction and cost saving for development of electronic control systems(ECU) in automotive industry, the applications of a standardized real-time operating system(RTOS) and a communication protocol to ECUs are increased. In this study, a body control module(BCM) that employs OSEK/VDX(open system and corresponding interfaces for automotive electronics/vehicle distributed executive) OS tour the RTOS and a controller area network(CAN) fur the communication protocol is designed, and the performances of the system are evaluated. The BCM controls doors, mirrors, and windows of the vehicle through the in-vehicle network. To identify all the transmitted and received control messages, a PC connected with the CAN communication protocol behaves as a CAN bus emulator. The control system based upon in-vehicle network improves the system stability and reduces the number of wiring harness. Furthermore it is easy to maintain and simple to add new features because the system is designed based on the standards of RTOS and communication protocol.

Construction History of the Old House "IMCHEONGGAK" in Andong and Estimation of its Original Structure -Focused on the 'Inner chamber' and the 'Sarang section'- (안동 "임청각(臨淸閣)"의 건축 이력과 원형 가구(架構) 추정 -사랑채와 안채를 중심으로-)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.25 no.2
    • /
    • pp.31-44
    • /
    • 2016
  • Imcheong-gak[臨淸閣] was a familial residence constructed in the early half of the Joseon dynasty period. It was partially destroyed by a fire during the 1590s war[壬辰倭亂] with the Japanese, and another fire that was caused between 1631 and 1634. The inner chamber[An-chae] and the Sarang section[Sarang-chae] today is the result of a partial reconstruction that took place back in 1626 and again around 1634. The residence also went through some changes because the new Ondol[溫突] heating system had to be applied to the structure. Based upon sections that remain in their original forms, we can presume that the Imcheong-gak residence originally had an inner chamber which was composed of the following elements: A main structure which was built upon a foundation featuring a Matbae[맞배] roof, two "Ik'rang[翼廊, flank]" sections on the East and West sides of the inner chamber, and a "Haeng'rang[行廊, passage]" structure on the opposite side of the main structure. Unlike the main structure, other portions of the inner chamber were all built directly upon the ground, and showed multiple stories, with Matbae roofs of their own. We can also assume that the Sarang section in the south would have been a pre-Ondol[溫突] bedroom, with a Board platform[板房] and a Gomi-ceiling[Gomi-banza] fashion.

The Design Characteristics of Spatial Organization Elements Observed in Malaysian Hotel Lobbies (말레이시아 호텔 로비에 나타난 공간구성요소의 디자인 특성)

  • Oh, Hye-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.5
    • /
    • pp.188-196
    • /
    • 2011
  • The objective of this study was to identify the design characteristics of space components observed in Malaysian hotel lobbies. For this study, we conducted a case study on the facades and indoor space components of 15 hotel lobbies in Langkawi and Penang, and drew conclusions as follows. First, designs found in the facades and indoor space components of Malaysian hotel lobbies reflected all of traditional and colonial styles, religious styles including Islamic, and contemporary styles. Second, traditional designs showed rather the modernization of traditions than the preservation of traditions. Particularly in ceilings, walls and windows/doors, conservative or progressive modemization was observed frequently. Third, contemporary designs were mostly formative modernization, and materials and colors still adhered to traditions and nature. Fourth, in applied furniture, traditional wood sculptures were mixed or traditional material rattarn(stems of climbing palms) was utilized actively. Fourth, a large number of designs symbolized the Malaysian first religion Islam. Summing up these results, the common point of designs observed in the facades and indoor space components of Malaysian hotel lobbies was that they were transformed into Malaysian style regardless of whether they were traditional or colonial.

An Experimental Research on the Room Acoustical Environment of the Elementary School Classrooms (초등학교 교실의 음환경 평가에 관한 실험적 연구)

  • Haan, Chan-Hoon;Moon, Kyu-Chun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.5-14
    • /
    • 2004
  • Since 1990s in Korea, elementary school classrooms have been designed toward open education system in pursuit of variety of educational purpose. Also, the architectural designs of schools have been acomplished for individual school not based on the standard design code. The present paper aims to investigate the acoustic environment of existing classrooms and to compare the sound insulation capacity between the ordinary classrooms and the newly built classrooms for open education. The current acoustical situation of elementary classrooms was analyzed using field measurements and questionnaire survey. In order to this, Three elementary schools were selected which were built in 1978, 1996 and 2000 respectively. Room acoustical parameters including Reverberation time(RT), Definition(D50), Speech Intelligibility(RASTI), Transmission loss(TL) and STC were measured in a classroom in each elementary school classroom. Each measurement was undertaken with the windows and doors being open or closed. As the result, it was found that the transmission loss between rooms in open classrooms is, $5{\sim}6dB$ in average, inferior than the ordinary classrooms. The RASTI of 0.70 was measured in newly built classrooms which is better than old classrooms(0.70) and open classrooms(0.73). This was shown as same in the speech definition measurements. This results from the condition of sealing and airtightness of classrooms and floor materials. The results denote that open classrooms have poor acoustic condition in sound insulation and speech intelligibility.

A Development of an Intelligent CAD Engine to Support Architectural Design Collaboration (건축설계의 협동작업을 지원하는 지능형 CAD 엔진의 개발)

  • 최진원
    • Korean Journal of Computational Design and Engineering
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 1997
  • Current CAD systems used in the AEC community have some critical problems. One of them is that they hardly support design collaboration. Thus designers and engineers are hard to transfer design knowledge from one discipline to another. What we need is a common building database which creates and manages building plans/models and relevant design knowledge consistently and effectively. This paper presents a powerful CAD editor, called UNIFORM, which is being developed. Currently UNIFORM includes three main modules: a plan generator, a 3-D model generator, and component databases. A plan generator, called UNIFORM PLANNER, creates a plan which contains semantically-rich information of building. Each component in the plan can be presented in various ways and connected to component databases that contain knowledge of building components such as windows, doors, walls, etc. Based on the plan UNIFORM MODELER, another module of the program, generates a three dimensional building model which could be a multiple-story building. One of the main ideas behind the system is that it generates and maintains a common building form that can be easily delivered to other members of the project team. Thus it is expected to increase system integration, team interactions, and productivity.

  • PDF