• 제목/요약/키워드: Window performance

검색결과 1,373건 처리시간 0.026초

저방사 코팅이 진공창의 열성능에 미치는 영향 (Study on thermal performance of vacuum window with various low-ε coating glasses)

  • 조성환;태춘섭
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.300-311
    • /
    • 1997
  • A theoretical method was developed to analyze the effect of low-$\varepsilon$ coatings which have influence on thermal performance of vacuum windwo glazing and double pane glazing. The overall heat transfer coefficient(U) value and thermal performance were analyzed by theroretical method on various kins of windows. TRNSYS program was used to analyze total heating and cooling energy consumption on the model building which has various windows. As the result, better thermal insulation can be achieved on the vacuum window glazing than double pane glazing when low-$\varepsilon$ coating was done on the surface of glass. Total heating and cooling energy consumption was almost same on the double pane window glazing but was lessened on the vacuum window glazing when the window size of south direction increased. Therefore, low-$\varepsilon$ coating was very necessary for vacuum window glazing in order to improve thermal insulation performance and efficient energy conservation can be achieved by vacuum window glazing at the real building which has large window.

  • PDF

다기능 복합 솔라윈도우 시스템의 에너지성능평가 (The Energy Performance Evaluation of Multi-purpose Solar Window System)

  • 조일식;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.10-15
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window System built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. The reference model of simulation was made up to analysis energy performance on Solar Window system. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

다기능 솔라윈도우의 열성능 연구 (The Study of Thermal Performance on Solar Window)

  • 조일식;김장회;양윤섭;김병수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in Heating/cooling performance analysis. The reference model of simulation was made up to analysis Heating/cooling performance on Solar Window. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

  • PDF

푸싱 방식에 의한 윈도우 입력 버퍼 스위치의 성능 향상 에 관한 연구 (Window input buffer switch performance progressing by pushing police)

  • 양승헌;조용권;곽재영;이문기
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(1)
    • /
    • pp.123-126
    • /
    • 2000
  • In this paper, we are proposed to pushing window input buffer A.T.M Switch that is not use memory read and write of general window police. Pushing window switch is superior to general window switch in performance but is large to general window switch in cross point number. Max throughput and Cell occupying probability results are verified by analysis an simulation. The evaluation of performance is max throughput and cell loss probability and mean queue length.

  • PDF

건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가 (A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.1-6
    • /
    • 2010
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.

수정된 Sinc 보간법을 이용한 새로운 Rayleigh 페이딩 보상 알고리즘 (An Improved Rayleigh Fading Compensation Algorithm with Modified Sinc Interpolation)

  • 이창재
    • 한국통신학회논문지
    • /
    • 제25권10A호
    • /
    • pp.1492-1498
    • /
    • 2000
  • Sine 보간법을 이용한 PSAM은 Cavers의 최적 Wiener 필터를 사용한 알고리즘보다 구현은 간단하면서 채널추정 성능은 거의 동일하다. 그러나 이 알고리즘은 window 함수와 같이 사용해야만 우수한 채널추정 성능을 갖는다. 본 논문에서는 이러한 기존의 sine 보간법 (conventional sine interpolation : CSI) 의 단점을 보완한 수정된 sine 보간법 (modified sine interpolation : MSI) 을 제안한다. MSI 알고리즘의 성능평가를 위해 다중반송파 QAM 시스템과 주파수 선택성 페이딩을 고려한 최적 프레엄구조를 사용하였다. 성능평가에서 window 함수를 사용하지 않은 MSI 알고리즘은 더 적은 수의 파일럿 심볼을 사용하면서도, window 함수를 사용한 CSI 알고리즘과 거의 동일한 BER 성능을 보였다. 아울러, window 함수를 사용한 MSI 알고리즘의 성능은 PSAM을 적용한 이론적인 16QAM의 성능과 거의 일치하였다.

  • PDF

편측창에서 창개구부의 형상이 천공상태별 채광성능에 미치는 영향 (Effects of Different Fenestration Configurations on Daylighting Performance in Unilateral Window under Clear and Overcast Sky Conditions)

  • 술타나 아즈미리;김정태
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.105-113
    • /
    • 2009
  • Daylighting provides the opportunity for both energy savings and improved visual comfort. An accurate estimation of the amount of daylight entering a building is the key step for daylight designing. This research aims to assess comparative daylighting performance of four different configurations of fenestration in case of unilateral windows and their variation under clear and overcast sky conditions. The selected window openings in this study were single punched, double punched, multiple punched and clerestory, and the area was same for each type of window. The experiment was designed for an office space using 1/10 scale model. Daylighting performance was evaluated by measuring the illuminance on work-plane height using Agilent data logger and photometric sensor Li-Cor. Thecomputer program ECOTECT was also used to simulate the pattern of interior illuminance distribution. Clerestory window showed the best performance in term of both illuminance level and distribution in the experiment. Multiple punched window provided more uniform illuminance distribution than single punched window. Lowest daylighting performance in the experiment was shown by double punched window.

창호의 단열성능에 따른 공동주택 냉난방 부하량 변화 (The Change of Heating and Cooling Load according to the Thermal Insulation Performance of Window for an Apartment House)

  • 송수빈;김영탁;윤성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.853-856
    • /
    • 2008
  • Windows have an great effect on annual building load because windows are the weakest parts of building envelope thermally. To reduce the consumption of building energy, the thermal performance of window has to be improved in first place. Therefore this research aims to make a quantitative analysis of the heating and cooling load according to the window thermal performance using the heat load simulation program. As a result of the simulation, annual heat load is down 38% according to the decrease of U-value of window, 1.00 W/$m^2K$. and annual heat load is up 10% according to the decrease of shading coefficient, 0.20. The annual load of the window with Low-E glass is 15% lower than the window with pair glass.

  • PDF

MAC Frame Aggregation이 가능한 에드혹 네트워크에서의 Congestion Window Limit을 통한 TCP 성능의 최적화 (TCP Performance Optimization Using Congestion Window Limit in Ad Hoc Networks with MAC Frame Aggregation)

  • 강민우;박희민;박준상
    • 한국ITS학회 논문지
    • /
    • 제9권4호
    • /
    • pp.52-59
    • /
    • 2010
  • 무선 애드혹 네트워크에서 MAC layer의 효율을 높이기 위한 하나의 방법으로서 사용되는 MAC frame aggregation은 MAC layer에서 여러 개의 MPDU (MAC protocol data units)를 하나의 PPDU (PHY protocol data units)로 aggregation 시켜서 성능을 향상시키는 방법이다. 애드혹 네트워크에서 TCP 성능 향상을 위해서 사용되는 방법의 하나로서 CWL (congestion window limit)의 설정 방법이 있는데 이는 congestion window의 상한을 두어 부적절한 congestion window 크기가 선택에 따른 영향을 최소화 하고자 하는 방법이다. 본 논문에서는 MAC frame aggregation이 가능한 MANET에서 최적화된 TCP 성능을 위하여 CWL를 조정하는 방법에 대하여 다룬다.

초음파 영상시스템에서 카이저 윈도우를 이용한 사이드 로브 감축에 관한 연구 (A Study on Sidelobe Reduction Using Kaiser Window in Ultrasonic Imaging System)

  • 나병윤;안영복;정목근
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.189-200
    • /
    • 1996
  • In this paper, we compared the performance of the Kaiser window with those of others as a weight function of well known anodization technique for regression of side lobe in a field pattern resulted from focusing of transducer array. The Kaiser window is an window providing many types of curve with several variables. In order to compare performance of the Kaiser window as the weight function, anodization results of the previously used Hamming window function and the Matched Gaussian function are compared Result of computer simulation, the pertormance of Kaiser window with $\delta$=0.0025 in side lobe regression was better than that of Hamming window or Matched Gausian function.

  • PDF