• Title/Summary/Keyword: Window opening

Search Result 133, Processing Time 0.022 seconds

Intelligent and Responsive Window Opening-Closing Operation Process for Carbon Dioxide(CO2) Management of Secondary School Classroom (중등학교 교실의 이산화탄소(CO2) 관리를 위한 지능형 창호개폐 작동 프로세스)

  • Choi, Yoon-Young;Lee, Hyun-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.4
    • /
    • pp.19-30
    • /
    • 2018
  • The school classroom is a common living place where students spend 7 to 14 hours a day to prepare for their careers. Therefore, if the ventilation of the classroom is not properly performed, it may lead to the deterioration of learning ability due to the unclear air. The concentration of carbon dioxide in the classroom is reported to be high, and the increase in carbon dioxide concentration has a negative effect on the learner's academic performance. In this context, the purpose of this study is to propose a methodology for intelligent and responsive window opening-closing operation process that can reduce the concentration of $CO_2$ in the classroom in order to build a support space that can create an effective teaching-learning environment for adolescents. The specific objectives are as follows. First of all, we define the concept of window opening-closing operation. Secondly, twe develop the operation process of window opening-closing. Thirdly, we develop an algorithm for real-time window opening and closing (process) (Window Opening-Closing Operation Process). Finally, we verify the intelligent responsive window opening-closing operation process through developing examples of window opening-closing operation process using the parametric design program. This study is a preliminary study to develop algorithms necessary for window opening-closing operation. Based on the first-order algorithm, We simulated window opening-closing operations according to a hypothetical scenario. As a result, This study can show that the window is open and close depending on the $CO_2$ concentration, but the $CO_2$ concentration in the room is higher than outdoors. Consequentially, we suggest that it is necessary to develop an algorithm to supplement these results because window is often not working when the temperature difference between indoor and outdoor in winter is large.

A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types (케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구)

  • Choi, Taehwoan;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.57-62
    • /
    • 2007
  • At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.

Comparison of implant survival rate by sinus lifting technique in implantation with sinus lift (상악동 거상술을 동반한 임플란트 식립 시에 거상술 방법에 따른 임플란트 생존율의 비교)

  • Park, Kwang-Su;Hong, Ki-Seok;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.445-452
    • /
    • 2008
  • Purpose: The purpose of this study was comparison of survival rate of implant as two sinus elevation techniques and when window opening procedure had done it was comparison of survival rate of implant between the procedure of implantation after 6 month of sinus elevation to allow healing period and that of implantation with sinus elevation simultaneously. Material and Methods: All 79 of patients treated at DanKook University Dental Hospital Dept. of Periodontics for 164 implantation of maxillary posterior edentulous area with sinus elevation. Sinus elevation technique was divided of the technique : Osteotome technique and window opening technique. Result: 14 implants among 96 implants was failed implants of using osteotome for sinus elevation whereas one implant of 68 implants was failed of using window opening technique. Conclusion: Window opening technique had higher survival rate than osteotome technique. In case of window opening, there was no significant difference of immediate implantation and delayed implantation.

The investigation into the standards and performances of domestic and foreign windows for an apartment house (국내외 공동주택용 창호의 기준 및 성능 조사)

  • Song, Su-Bin;Kim, Young-Tag;Yoon, Seong-Kon;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.330-335
    • /
    • 2008
  • This research aims to investigate the standards and the performances of domestic and foreign windows for and apartment house and to present fundamental data for selecting the optimum window at the step of designing an apartment house. To compare the performances of domestic and foreign windows it is selected 5 major window companies in and 3 major window companies in Japan, and investigated window structure, material, type of opening and closing, window glass and the performances of windows for an apartment house-closing and opening force, repeated closing and opening, thermal resistance, sound transmission loss, air tightness, water tightness, wind resistance. The result of a comparative analysis show that the average thermal resistance of Korean window is higher than Japan's but the average sound transmission loss and water tightness of Korean window is lower than Japan's and the rest of the performances is similar.

  • PDF

A Study on the Enhance of Air tightness Performance of a New Type Silding Window with horizontally Rolling Wheels (수평 구름 바퀴가 적용된 신 유형 미서기 창문의 기밀성능 개선에 관한 연구)

  • Jang, Hyok-Soo;Kim, Young-Il;Chuung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.63-70
    • /
    • 2015
  • Crevices between window and window frame cause not only heat losses but also serve path to sound transmission and infiltration of fine dusts that are harmful to humans. There were many efforts in the past to eliminate these crevices but because of the windows' indispensable function of opening and closing, it was an unsolvable problem. In this study, a new type sliding window is developed by applying horizontally rolling wheels to implement a surface sealing which is excellent for enhancing air tightness. To evaluate the feasibility of the newly developed window, forces for opening and closing, durability and air tightness were testet according to Korean Testing Standards. Force for opening a 2000 N window is 30 N. It endured 100,000 cycles of opening and closing. Infiltration was $0.00m^3/(m^2h)$ for a pressure difference of 10 Pa. Since this window has few moving parts, it has favorable features of low cost and few breakdown.

Convergent Investigation with Internal Flow Analysis According to the Opening and Closing of Vehicle Window (차량 창문 개폐에 따른 내부에서의 유동 해석으로의 융합적 고찰)

  • Oh, Bum-Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.2
    • /
    • pp.155-160
    • /
    • 2020
  • In this study, the pleasant driving environment of the driver and passenger in the summer was investigated through the internal flow analysis of air due to the opening and closing of the car windows. The conditions on the entrance of the air conditioner with the opening and closing status of vehicle window were applied to the flow analysis by taking into consideration the actual driving environment. The automotive air conditioning outlet, the seat and the inside of car were modeled. As the air flow inside the car was analyzed, the air flow configuration and the temperature distribution were examined. In this analysis, the results were taken in consideration of only the effects of internal air and the opening and closing of window, assuming the interior of the vehicle as insulation. The analysis of each condition shows that these models maintain a pleasant environment. It is seen that this analysis result on the internal flow analysis according to the opening and closing of vehicle window can be applied by converging with the field of design.

Study on Thermal Comfort in according to Rate of Opening Windows of Flat-type Apartment (판상형 아파트의 창문개폐율에 따른 열쾌적도 분석)

  • Kim, Sung Gil
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.93-98
    • /
    • 2013
  • The purpose of this study is to analyze the rate of opening windows that makes residents of a flat-type apartment feel pleasant in summer time. A few conditions were simulated on the wind flow that pass through internal and external spaces of the flat-type apartment, utilizing CFX program. The simulation was made with the criteria for the rates of opening window at 20%, 50%, 70% and 100%. When the rate of window opening was more 50%, the wind speed(more than 1m/s) that makes the residents feel pleasant was observed in more 60% of the internal space. When the all windows of the apartments were opened, the heat island phenomenon was almost disappeared and the pleasant wind flow was more evenly distributed in the external spaces. If residents of apartments recognize the result of this study and practice in agrement on opening windows in summer, it is expected to contribute to minimizing the energy consumption for air conditioning.

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(III) -A variation of temperature and humidity by the window opening ways of the even-Span type house- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(III) -양지붕형 하우스의 창 개방방법에 따른 온.습도의 변화-)

  • 김진현;김철수;구건효;이기명
    • Journal of Biosystems Engineering
    • /
    • v.20 no.2
    • /
    • pp.162-172
    • /
    • 1995
  • The ventilation in greenhouse have been important for such as adjustment of temperature, supplying of the oxygen, prevention of the overhumidity, density adjustment of $CO_2$, discharge of harmfulness gas, etc. However, the general ventilation which had been used the quantitative control method in discharge of a property of air mechanism in greenhouse, and caused mainly in waste of the heating energy and growth obstacle of the vegetable. Therefore, this study was peformed to obtain more scientific ventilation method using by analysis and measurement of the isothermal lines according to opening of window ventilation in greenhouse, and the results are summarized as follows. 1. The ventilating amount was more influenced by rather opening amount of window than the ventilating time. 2. In window ventilation, the temperature in greenhouse was mostly changed within 5 minutes after ventilating not regard to the spot of opening, after about 10 minutes temperature became to equilibrium state under the respective ventilating conditions. 3. In opening of the skylight only, isothermal lines were complicated, therefore, a tall vegetable may be possible to damage by a cold-weather from the lower central port in greenhouse. 4. Isothermal lines were a tendency to simply in opening of a side window that may be more effective ventilation in kinds of the short vegetable. 5. In conditions of internal temperature>setting temperature>external temperature, a skylight can be suitable to open 10~20cm in order to the optimum ventilation in greenhouse. 6. In conditions of internal temperature>external temperature>setting temperature, opening of all the windows or both the side windows that can be suitable in order to obtain the optimum ventilation in greenhouse. 7. An effect of ventilation was the most excellent to open of all the windows or both the side windows, and it were also found orderly excellent to open of the side window and the skylight or the skylight only, to open of the side window only. 8. Temperature was varied as the equation of T=Tc+ (To-Tc)e-at, and the ranges of (a) values were limited within 0.34~0.68. 9. A variations of humidity were similar to that of temperature, s.

  • PDF

Shear capacity of Unreinforced Masonry Wall with Opening (개구부를 갖는 조적벽체의 전단내력에 관한 연구)

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.69-72
    • /
    • 2006
  • The objective of this study is to find out the shear capacity of URM wall and the variables that affect the shear capacity of URM wall such as the opening and the aspect ratio, considering four kinds of failure modes, sliding shear failure, toe crushing failure, and diagonal shear failure. The main varialble is the shape of opening of URM walls. First URM has one door, second has one window, third hase one door and one window, the last has two windows. The test results of URM with openings show that the specimens are governed by rocking failure mode.

  • PDF

A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea (국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구)

  • Lee, Kyu-Min;Koo, Tae-Yoon;Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF