• Title/Summary/Keyword: Window Manipulation

Search Result 24, Processing Time 0.027 seconds

Characterization of Dielectrophoretic Force for the Structural Shapes of Window in Microfluidic Dielectrophoretic Chip (미세유체칩내 electrode의 opening window형태에 따른 유전전기영동력 특성 규명)

  • Lee, Jaewoo;Kwak, Tae Joon;Yoon, Dae Sung;Lee, Sang Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.189-196
    • /
    • 2013
  • Dielectrophoresis(DEP) is useful in manipulation and separation of micro-sized particles including biological samples such as bacteria, blood cells, and cancer cells in a micro-fluidic device. Especially, those separation and manipulation techniques using DEP in combination of micro fabrication technique have been researched more and more. Recently, it is revealed that a window structure of insulating layer in microfluidic DEP chip is key role in trap of micro-particles around the window structure. However, the trap phenomenon-driven by DEP force gradient did not fully understand and is still illusive. In this study, we characterize the trap mechanism and efficiency with different shapes of window in a microfluidic DEP chip. To do this characterization, we fabricated 4 different windows shapes such as rhombus, circle, squares, and hexagon inside a micro-fluidic chip, and performed micro-sized particles manipulation experiments as varying the frequency and voltage of AC signal. Moreover, the numerical simulation with the same parameters that were used in the experiment was also performed in order to compare the simulation results and the experimental results. Those comparison shows that both results are closely matched. This study may be helpful in design and development of microfluidic DEP chip for trapping micro-scaled biological particle.

A Comparison of Pelvic Tilt Before and After Manipulation of Sacroiliac Joint in the Patients with Low Back Pain (요통환자의 천장관절에 대한 도수교정 전과 후의 골반경사 비교)

  • Oh, Seung-Gil;Lee, Jin-Haeng
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.579-595
    • /
    • 2000
  • The purposes of this study were to compare pelvic tilt before and after manipulation of sacroiliac joint in 31 low back pain patients (11 males, 20 females) with sacroiliac joint dysfunction. The sacroiliac joint of patients was manipulated on the side of anterior pelvic tilt, using the technique described by Stoddard (1962) and Greenmann (1996). I used this technique because it usually eliminated sacroiliac joint dysfunction in one treatment session. SPSS for window computer system was used to analyze the data. Also t-test was performed for comparison of pelvic tilt angle before and after manipulation, and Pearson product-moment correlation analysis was performed for intratester reliability for measurements of pelvic tilt angle before and after manipulation. The result were as follows: 1. Intratester reliability was good for measures of pelvic tilt (r=.98). 2. The pelvic tilt after manipulation was significantly decreased (mean=$3.40^{\circ}$) compared with the pelvic tilt before manipulation (p=.001). All subjects showed asymmetrical right versus left pelvic tilt before manipulation. 40% of subjects showed decreased asymmetrical right versus left pelvic tilt after manipulation, and 60% of subjects showed symmetrical right versus left pelvic tilt after manipulation. I think that pelvic tilt asymmetry with hypomobility due to loss of joint play could be symmetrized by manipulation or mobilization, but pelvic tilt asymmetry with unilateral pelvic muscle shortening could not be symmetrized by manipulation or mobilization without relaxation and stretching of shortened muscles.

  • PDF

Biomechanical changes in lower quadrant after manipulation of low back pain patients with sacroiliac joint dysfunction (요통환자의 엉치엉덩관절 기능부전에 대한 도수교정 후에 하지의 생체역학적인 변화)

  • Oh, Seung-Gil;Yoo, Seung-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.893-906
    • /
    • 2001
  • The purposes of this study were to compare pelvic tilt. range of motion(ROM) of hip rotation, and leg length difference before and after manipulation and to investigate correlation between changes of each variables after manipulation of sacroiliac pint in 31 low back pain patients(11 males, 20 females) with sacroiliac pint dysfunction. The sacroiliac pint of patients was manipulated on the side of anterior pelvic tilt, using the technique described by Stoddard(1962) and Greenmann (1996). I used this technique because it usually eliminated sacroiliac Pint dysfunction in one treatment session. SPSS for window computer system was used to analyze the data. Also t-test was performed for comparison of the variables before and after manipulation, and Pearson product-moment correlation analysis and regression analysis were performed for changes of each variables after manipulation. The result were as follows: 1. The pelvic tilt after manipulation was significantly decreased(mean=$2.79^{\circ}$) compared with the pelvic tilt before manipulation(p=.001). 2. The PROM of hip internal rotation ipsilateral to anterior pelvic tilt after manipulation significantly decreased (mean = $1.88^{\circ}$) compared with hip internal rotation before manipulation (p=.008). The PROM of hip internal rotation ipsilateral to posterior pelvic tilt after manipulation significantly increased(mean = $1.29^{\circ}$) compared with hip internal rotation before manipulation (p=.029). 3. The PROM of hip external rotation ipsilateral to anterior pelvic tilt after manipulation significantly increased(mean=$2.42^{\circ}$) compared with the hip external rotation before manipulation(p=$2.42^{\circ}$) compared with the hip external rotation ipsilateral to posterior pelvic tilt after manipulation significantly decreased(mean = $1.84^{\circ}$) compared with the hip external rotation before manipulation (p=.008). 4. Leg length difference after manipulation significantly decreased(mean=2.15 mm) compared with leg length difference before manipulation (p=.008). Regression analysis revealed that a fair correlation was found between change in leg length difference and change in anterior pelvic tilt after manipulation(p=.009). 5. Pearson product-moment correlation coefficient was used to assess differences of the variables after manipulation. A fair correlation was found between change in leg length difference and change in anterior pelvic tilt after manipulation(r=.462, p<.01). A fair correlation was found between change in anterior pelvic tilt and change in hip internal rotation ipsilateral to anterior pelvic tilt(r=.397, p<.05) and between change in anterior pelvic tilt and change in hip external rotation ipsilateral to anterior pelvic tilt(r=.516, p<.01). A fair correlation was found between change in posterior pelvic tilt and changes in hip internal rotation ipsilateral to posterior pelvic tilt (r=.441, p<.05) and between change in posterior pelvic tilt and change in hip external rotation ipsilateral to posterior pelvic tilt(r=.361, p<.05). A fair correlation was found between change in hip internal rotation ipsilateral to anterior pelvic tilt and change in hip external rotation ipsilateral to posterior pelvic tilt(r=.388, p<.05) and between change in hip internal rotation ipsilateral to posterior pelvic tilt and change in hip internal rotation ipsilateral to anterior pelvic tilt(r=.426. p<.05).

  • PDF

Visual Touchless User Interface for Window Manipulation (윈도우 제어를 위한 시각적 비접촉 사용자 인터페이스)

  • Kim, Jin-Woo;Jung, Kyung-Boo;Jeong, Seung-Do;Choi, Byung-Uk
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.6
    • /
    • pp.471-478
    • /
    • 2009
  • Recently, researches for user interface are remarkably processed due to the explosive growth of 3-dimensional contents and applications, and the spread class of computer user. This paper proposes a novel method to manipulate windows efficiently using only the intuitive motion of hand. Previous methods have some drawbacks such as burden of expensive device, high complexity of gesture recognition, assistance of additional information using marker, and so on. To improve the defects, we propose a novel visual touchless interface. First, we detect hand region using hue channel in HSV color space to control window using hand. The distance transform method is applied to detect centroid of hand and curvature of hand contour is used to determine position of fingertips. Finally, by using the hand motion information, we recognize hand gesture as one of predefined seven motions. Recognized hand gesture is to be a command to control window. In the proposed method, user can manipulate windows with sense of depth in the real environment because the method adopts stereo camera. Intuitive manipulation is also available because the proposed method supports visual touch for the virtual object, which user want to manipulate, only using simple motions of hand. Finally, the efficiency of the proposed method is verified via an application based on our proposed interface.

Development of a PC based Simulator for Excavator Manipulation using Virtual Reality (PC기반의 가상현실을 이용한 굴삭기 조작 시뮬레이터 개발)

  • Lee, Se-Bok;Kim, In-Shik;Cho, Chang-Hee;Kim, Sung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.536-541
    • /
    • 2000
  • A low cost PC based simulator for excavator manipulation has been developed using virtual reality technology. The simulator consists of two joystick input devices, server and client PCs, an excavator kinematics module, and a graphic rendering program Open Inventor. In order to use two joysticks in the PC window environment multi-thread programing with network protocol TCP/IP has been used. To provide realistic view to the operator, CAD program Pro/Engineer and 3D modeller have been employed to create 3D part geometry of tile manipulator and virtual environmental geometries. Those geometries also have been transformed and imported to the Open Inventor. The Simulator developed is to be improved for more realistic excavator operational training.

  • PDF

The estended query-by-example supporting subqueries (부질의 기능을 추가한 확장된 Query-by-Example)

  • 원희선;이종학;황규영
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.9
    • /
    • pp.10-21
    • /
    • 1994
  • Query-by-Example(QBE) is high-level display-oriented databased manipulation language that provides a convenient and unified style for querying, updating, defining, and controling a relational database. QBE is relationally complete. However, lack of aubquery constructs limits th usability of QBE significantly. In particular, certain queries cannot be represented in one window. In this paper, we define a subquery box and extend QBE for subquery construction. The Extended QBE makes it possible to represent the queries that the QBE cannot do in one window, reducing the overhead and complexity of composing those queries. We also define the grammar of the Extended QBE and present the parsing techniques. Finally, we present an algorithm to transform the queries in Exteded QBE to those in SQL. The result of the transformation can be executed using dynamic SQL features of any SQL system. The proposed language has been implemented on OS/2 using the OS/2 EE Database Manager.

  • PDF

ON THE ALGORITHM FOR BOAO CCD CAMERA CONTROL SOFTWARE (보현산천문대 CCD 카메라 제어 소프트웨어 알고리즘)

  • Yuk, In-Su;Park, Byeong-Gon
    • Publications of The Korean Astronomical Society
    • /
    • v.11 no.1
    • /
    • pp.147-161
    • /
    • 1996
  • The development of universal CCD camera control software for all BOAO CCD camera systems is proposed. The new software, running under Sun SPARCstation and motif based X window system with SunOS 4.1.3 operating system, replaces existing control software based on NeXTstation color and NeXTstep 2.1 operating system which is no more produced now. Several new features of the new software is introduced, some of which are 1) the image contrast is enhanced by color manipulation and display, 2) image zooming and trimming, 3) any size of image can be displayed in the scrolled window, and 4) the offset between telescope pointing position and CCD center is easily calculated by alt-azi map. Along with the above new features, the new software has advantages including ease of maintenance and upgrading and elimination of risk caused by hardware damage. Since September 1, the software beta version is being used by observers and there is not seen severe problem regarding the software itself, but several requests to equip more features to the software will be mirrored to future release.

  • PDF

Manipulation of the Windows Interface Based on Haptic Feedback (촉각 기반 윈도우 인터페이스)

  • Lee, Jun-Young;Kyung, Ki-Uk;Park, Jun-Seok
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.366-371
    • /
    • 2008
  • In this paper, we suggest a haptic interface and a framework of interaction with haptic feedback based Windows graphical user interface (GUI) in a computing device with touch screen. The events that occur during a user interacts with Windows interfaces through a touch screen are filtered out by the Windows Interface Message Filter (WIMF) and converted into appropriate haptic feedback information by the Haptic Information Provider (HIP). The haptic information are conveyed to users through a stylus-like haptic interface interacting with a touch screen. Major Windows interaction schemes including button click, menu selection/pop-up, window selection/movement, icon selection/drag & drop and scroll have been implemented and user tests show the improved usability since the haptic feedback helps intuition and precise manipulation.

  • PDF

The Effects of a Circle-based Early Childhood Science Education Program Using Physical Movement on Young Children's Scientific Inquiry Ability, Scientific Attitude, Object Manipulation Ability and Spatial Ability (신체움직임을 활용한 순환학습기반 유아과학교육 프로그램이 유아의 과학적 탐구능력, 과학적 태도, 물체조작능력 및 공간능력에 미치는 효과)

  • Chung, Gibun;Kim, Jihyun
    • Korean Journal of Childcare and Education
    • /
    • v.15 no.6
    • /
    • pp.139-167
    • /
    • 2019
  • Objective: This study aims to investigate the effects of a learning cycle model-based early childhood education program using physical motion on young children's scientific inquiry ability, scientific attitude, object manipulation ability and spatial ability. Methods: The subjects of this study were 60 five-year-old children who were attending K-G City Childcare Center. The SPSS Window 21.0 program and content analysis method were used, and post-validation Tukey was conducted to examine the differences between the one-way ANOVA and the group. Results: Activities using body movement were practiced systematically based on the circle learning. Children could revise their pre-concept and concept of error by interacting with other children, teachers and the environment. Furthermore, children were attaining new knowledge while they were doing body movement activities, assessing and applying them to actual activities. Conclusion/Implications: This study is investigated a cyclic learning-based early childhood science education program using physical motion, which has significance in systematic and practical early childhood centered education for young children.

The Development of Window Operating EMTP Package Using Matlab (매트랩을 사용한 윈도우 구동형 EMTP 패키지의 개발)

  • 이재용
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.3
    • /
    • pp.79-84
    • /
    • 1999
  • The existing EMTP(Electromagnetic Transients Program) is writted by FORTRAN-77, has a closed architecture and uses a large number of code lines to satisfy requirements ranging from low level data manipulation to the actual solution mathematics which eventually become diluted and almost impossible to visualize. Thus has a difficulty in the development and maintenenace of its program module. This paper proposes a new design idea suitable (or a re-development of EMTP using the MATLAB and VISUAL-C++, which presents the development of the new EMTP package is operated in the window environment. The package has the GUI(Graphic User Interface) ability, and the MATLAB computation engine for an analysis of a transient state in an electric circuit.

  • PDF