A Study on the One-chip Design of Low Cost for Micro-stepping Drive of 5-Phase Stepping Motor Having Pentagon Type Winding (5상 펜타곤 결선방식 스테핑 모더의 마이크로스텝 구동을 위한 저가형 전용 칩 설계에 관한 연구)

  • Kim Myung-Hyun;Ahn Ho-Kyun;Park Seung-Kyu;Son Young-chul
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.451-454
    • /
    • 2002
  • In this paper, studied on the one-chip design of low cost for the micro-stepping drive having 5-phase Pentagon Type winding. Micro-stepping method in order to eliminate effectively the resonant phenomena and to Increase the positional resolution. This paper proposed trapezoidal current wave- form for current control and provided design- method by using only one-chip of low cost. Therefore the drive will be simple and small size. Also the drive will have a lot of advantage at commercial business. Finally the above study has been implemented on the VHDL. Simulation has been performed to verify the PWM for micro-stepping drive.

  • PDF

Design Methodology for Minimal Stator Copper Loss in A Single-phase Induction Motor (단상 유도전동기의 고정자 동손 최소화를 위한 설계 방법)

  • Baek, Soo-Whang;Kim, Byung-Taek;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1536-1545
    • /
    • 2008
  • In this paper, we research a new method for efficiency improvement of a single-phase Induction motor by minimization of the stator loss. To make this, we perform winding design which is based on balanced and quasi-balanced operation condition. It gives efficiency improvement greatly but poor starting torque simultaneously. To obtain the best efficiency improvement maintaining the maximum and starting torque, the optimal winding specification and rotor dimension is determined with variation of secondary resistance, running capacitor and turn ratio. Finally, this paper gives the comparison between the simulation results and experimental results.

Characteristics Analysis of a Forward Converter by Finite Element Method Considering Hysteresis and State Variables Equation (히스테리시스를 고려한 유한요소법과 회로 방정식을 이용한 포워드 컨버터의 동작특성 해석)

  • Park, Seong-Jin;Kwon, Byung-Il;Park, Seung-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.6-8
    • /
    • 1999
  • This paper presents a method to analyze a forward converter. A transformer is coupled with the forward converter electric circuit and then the finite element analysis considering a hysteresis phenomenon of magnetic core is carried out when the primary or the reset winding conducts current. The analytical method is used to reduce the computation time when the reset winding circuit of the transformer turns off. As a result, the simulation results show a good agreement with experimental ones.

  • PDF

A Comparative Study on Fault Detection Algorithm of AC Generator (교류 발전기의 고장 검출 알고리즘에 관한 비교 연구)

  • Park, Chul-Won;Shin, Kwang-Chul;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.102-108
    • /
    • 2008
  • AC generator plays an important role of power system. The large AC generator fault may lead to large impacts or perturbations in power system. And then the protection of a generator has very important role in maintaining stability in a power system. In present, the DFT(discrete Fourier transform) based RDR(ratio differential relay) had been widely applied to a internal fault of a generator stator winding. But DFT has a serious drawback. In the course of transforming a target signal to frequency domain, time information is lost. DWT uses a time-scale region. This paper proposes an advanced fault detection algorithm using DWT(discrete Wavelet transform) to enhance the drawback of conventional DFT based relaying. To evaluate the performance of the proposed relaying, we used the test data which were sampled with 720 [Hz] per cycle and obtained from ATP(alternative transient program) simulation. And we made a comparative study of conventional DFT based RDR and the proposed relaying.

Study on resonant frequency tracking for contactless power system using multiple primary winding contactless transformer (다중일차권선 비접촉변압기를 이용한 비접촉 전원시스템의 공진주파수 추적에 관한 연구)

  • Kim, Yoon-Ho;Rho, Sung-Chan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.3
    • /
    • pp.182-188
    • /
    • 2006
  • Contactless power system is base on power transmission by magnetic force. The transformer loss is large because it separated with the gap. Also the system has unstable factor, since the parameters in the secondary can vary with the system movement. This paper proposes light train power transmission system using contactless transformer with multiple primary winding. To increase the system efficiency and to obtain the stable power transmission to the dynamic load, a resonant inverter is adopted. The proposed system was verified by the simulation using Spice and Maxwell. The designed contactless power transmission system is implemented for 5[kW] class and experimental results are discussed.

Protective Relaying Algorithm for Transformer Using Wavelet Transform (웨이블렛 변환을 이용한 변압기 보호계전 알고리즘)

  • 홍동석;이종범
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.2
    • /
    • pp.134-141
    • /
    • 2003
  • The power transformer is one of the very important electric facilities in power systems. Recently, current differential relay is widely used to protect such power transformer But if inrush occurs in transformer, relay can be tripped by judging like internal fault. Therefore the correct discrimination between internal winding fault, inrush and overexcitation should be performed. This paper presents a new protective relaying algorithm which discriminates inrush, internal faults and overexcitation of transformer modelled using BCTRAN and HYSDAT of EMTP. Discrimination between internal winding fault and inrush is revealed in simulation within 1/2 cycle after fault. Accordingly, it is evaluated that the proposed algorithm has better discrimination characteristics in various cases thin the current relaying for protection of transformer.

A Study on the Analysis for Fluid Path Design of the Rotor considering Electrical Losses of High-Tc Superconducting Synchronous Motor (고온초전도동기모터의 전기적 손실에 따른 회전자의 유로 설계에 관한 연구)

  • Yoon, Yong-Soo;Song, Myung-Kon;Jang, Won-Kap;Chang, In-Bae;Lee, Sang-Jin;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.98-100
    • /
    • 1998
  • This paper presents the fluid characteristics simulation and design guide line of the fluid path inside the rotor, which has an high-Tc superconducting field winding using Ag sheathed BSCCO-2223. The analysis was conducted with an equivalent model of the high-Tc superconducting synchronous motor under transition condition that occurs during the load varying from 250watt to 500watt. The results show that the designed fluid circulation system performs adequately in maintaining the superconducting state in the winding.

  • PDF

The Modeling of inductive power collector for light railway system (소형궤도차량 시스템에 적합한 유도전력 집전 장치의 모델링)

  • Han, K.H.;Lee, B.S.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.215-217
    • /
    • 2005
  • In this paper, the inductive power collector using electromagnetic induction for the PRT{Personal Rapid Transit) system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power collector is used for the PRT system, which has a large air-gap and demands a large electrical power capability. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. Also, model of power collector and parallel winding structure are presented, in addition, the performance of inductive power collector to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

Fabrication of the HTS Solenoid for DG Reactor of 6.6kV/200A Inductive Superconducting Fault Current Limiter (6.6kV00A급 유도형 초전도한류기의 DC 리액터용 고온 초전도 솔레노이드의 제작)

  • 김현석;안민철;이승제;이안수;이상진;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.230-233
    • /
    • 2003
  • This paper deals with the fabrication of high temperature superconducting(HTS) solenoid for DC reactor of 6.6㎸/200A inductive superconducting fault current limiter(SFCL). The winding machine which is suitable to wind HTS wire was manufactured. The proper inductance was calculated by circuit simulation and G10-FRP bobbin was fabricated with this inductance, HTS solenoid was wound by using the winding machine. The V-I characteristic of completed DC reactor in sub-cooled nitrogen(65K) was measured. The full quench current of this magnet is about 490A.

  • PDF

A Selection of an Optimal Mother Wavelet for Stator Fault Detection of AC Generator (교류 발전기 고정자 사고 검출을 위한 최적 마더 웨이브릿의 선정)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.377-382
    • /
    • 2008
  • For stator winding protection of AC generator, KCL(Kirchhoff's Current Law) is widely applied. Actually a CRDR(Current Ratio Differential Relay) based on DFT(Discrete Fourier Transform) has been used for protecting generator. It has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. Wavelets techniques are proposed for the analysis of power system transients. This paper introduces an algorithm to choose a suitable Mother Wave1et for generator stator fault detection. For optimal selection, we analyzed db(Daubechies), sym(Symlets), and coif(Coiflects) of Mother Wavelet. And we compared with performance of the choice algorithm using detail coefficients energy and RMS(root mean square) error. It can be improved the reliability of the conventional DFT based CRDR. The feasibility and effectiveness of the proposed scheme is proved with simulation using collected data obtained from ATP (Alternative Transient Program) package.