• Title/Summary/Keyword: Winding equipment

Search Result 56, Processing Time 0.027 seconds

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

The Characteristics analysis of a Flux-lock Type Fault Current Limiter according to the Winding Directions for Power Grid (전력계통 적용을 위한 결선방향에 따른 자속구속형 한류기의 특성 분석)

  • Lee, Mi-Yong;Park, Jeong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5879-5884
    • /
    • 2013
  • With the rapid industrialization and economical development, the electricity demands of the industrial facilities and densely populated large cities are continuing to increase in Korea. The increase in the power consumption requires the extension of power facilities, but it is difficult to secure spaces for equipment installation in the limited space of urban areas. In addition, the 154 kV or 345 kV transmission systems in Korea has a short transmission distance, and are connected to one another in network structures that ensure the high reliability and stability of power supply. This structure reduces the impedance during the fault in power system, and increases the magnitude of in the short circuit fault current. The superconducting fault current limiter (SFCL) was devised to effectively address these existing problems. The SFCL is a new-concept eco-friendly protective device that ensures fast operation and recovery time for the fault current and does not need additional fault detection devices. Therefore, many studies are being conducted around the world. In this paper, based on the wiring method the initial fault current characteristics, current limiting characteristics, according to the incident angle and the change in inductance current limiting characteristics were analyzed in a multifaceted methods.

An Analysis of the Place Branding Methods for Regenerated Idle Industrial Facilities (재생 유휴산업시설의 플레이스 브랜딩 방법 분석)

  • Cho, Youn-Joo;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.1
    • /
    • pp.54-63
    • /
    • 2015
  • This study aims to suggest the place branding methods applicable for regenerated idle industrial facilities. The place branding methods were analyzed by separating into hard branding methods and soft branding methods, and the results of the study are as follows: As for the hard branding methods, the exterior, outer wall materials and interior materials of the building and industrial equipment are preserved to revive the historicity of the building. In order to organize a differentiated space, it is important to create the convenience space such as cafes, experience space, lounge, and restaurants as well as the space for the operation of the programs. The building itself is utilized as a landmark or the iconic facility such as the winding tower or chimney is utilized as a landmark. As the methods of introducing natural elements, there is a need to create the resting space, law area and water space where trees can be planted and landscape can be viewed, and the development of tourism products utilizing the peripheral resources and the link of programs are also important. As for the soft branding methods, the provision of programs where a variety of art genres and the sense of place are reflected and the programs linked to the region is needed, and the story of place can be shared by storytelling utilizing the work and programs reflecting the sense of place. In addition, the content development and physical improvement of facilities reflecting the needs of visitors and the establishment of the organic collaboration system of a variety of subjects are needed for the sustainability of place.

Characteristics of the Fault Current and the Protection for Superconducting and Normal Conducting Limiter combined with a Transformer (상용변압기와 결합된 초전도체 및 상전도체 한류기의 고장전류 및 보호기기 동작특성)

  • Im, In-Gyu;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1313-1317
    • /
    • 2013
  • With increasing demand of power, the equipment of power system is enlarging and the absolute capacity is going up. As a result, when a fault occurs, the fault current is consistently increasing. Therefore, I suggested some solution for limiting the fault current more efficiently. This study shows the characteristics of superconducting limiting elements and normal conducting elements combined with a transformer. We performed a short-circuit test about the fault current by using SCR switching control system operated from a CT. When short circuit accidents happened in the secondary side of a transformer, fault currents flowed and a SCR switching control system was operated. It resulted in a decrease of the fault current in the limited elements of third winding connected in parallel. For this test, we used YBCO thin films and normal conducting elements as the limited elements. Within a cycle, a superconducting fault current limiter with YBCO thin films reduced more than 90% of fault current because the resistance of superconducting elements sustainedly grew. On the other hand, the limiter with normal conductors limited as much as a set value because its resistance characteristic was linear. Consequently, in case of the limiter with superconductor, limiting range of the circuit was wide but the range of protective detection was undefined. In contrast, as for the limiter with normal conductors, limiting range and protection duty were appropriate.

Hoop Ring Test Method to Evaluate the Fiber Material Properties of Composite Motor Case (Hoop ring 시험방법을 이용한 복합재연소관의 섬유방향 물성 평가)

  • Hwang, Tae-Kyung;Park, Jae-Byum;Kim, Hyung-Kun;Lee, Sang-Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.429-432
    • /
    • 2009
  • The deformation and burst pressure of composite motor case highly depends on fiber material properties. Therefore, measuring exact fiber material properties is a priority item to develop a advanced composite motor case. However, the fiber material properties in composite motor case is very sensitive on the various processing variables (equipment, operator and environmental condition etc..)and size effect, so the fiber material properties can't be measured exactly from the existing specimen test method. This paper suggests a newly developed test method, hoop ring test, that is capable of pressure testing with ring specimens extracted from real composite motor case. The results of hoop ring test showed excellent agreement with measured fiber material properties from hydro-burst test with full scale composite motor cases.

  • PDF

Study on the Design of a Rotary-type LSM and Test Equipment for Design Verification of LSM for Ultra-high-speed Train (초고속열차용 LSM 설계 검증을 위한 회전형 구조의 LSM 및 시험기 설계 연구)

  • Park, Chan-Bae
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.196-202
    • /
    • 2017
  • A very long test track is required for high-speed operation test of the real-scale Linear Synchronous Motor (LSM) for ultra-high-speed trains. The required length results in huge construction cost and economic loss if any error occurs during development. Therefore, validation study of the LSM design technology using a low-cost small-scale model must be carried out in the early research stages. It is possible to deduce an optimal winding method for the armature and determine the mechanical properties of the LSM through a performance tester that applies a rotary-type small-scale LSM model. In addition, it is possible to utilize previous research on LSM control systems. Therefore, a basic design model, comprising a rotary-type LSM tester that meets the requirements for the propulsion of 600km/h-class ultra-high-speed trains, is derived in this study. Finally, an optimal model, which has a stable structure under the condition of 1500rpm or more high-speed rotation, is derived by electromagnetic and mechanical stiffness analysis.