• 제목/요약/키워드: Winding direction

검색결과 90건 처리시간 0.035초

전초전도 호모폴라 모터의 3차원 자계해석 및 회로상수 추출 (3D Field Analysis And Circuit Parameter Calculation of Superconducting Homopolar Synchronous Motor)

  • 조영한;성탄일;김영선;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.700_701
    • /
    • 2009
  • In comparison with conventional motors, Superconducting Homopolar Synchronous Motors (SHSMs) have advantages that it generates high magnetic field by superconducting winding. Therefore, superconducting coil used in SHSM can reduce the motor size and enhance the motor efficiency for high torque applications under the space constraints for propulsion system. During the design process of SHSM, it is required to evaluate the performance of initial design model, that is accurately analyzed using 3D magnetic field modeling large air-gap and flux distribution of axial direction is properly taken into account. In this paper, we analyze magnetic field of a homopolar motor with a 4-pole homopolar rotor and a stator of 3 phase windings. The field analysis is done using 3D finite element analysis which can reflect the end effect and overhang winding. And we extract mutual inductances between a rotor wind and the 3 stator windings. The extracted inductances are used for evaluation of overall motor performances that are calculated with generalized circuit theory of electrical machines.

  • PDF

감극결선용 자속구속형 전류제한기의 사고주기별 전압전류 특성 (Voltage-Current Characteristics According to Fault Period of Flux-Lock SFCL with subtractive polarity winding)

  • 한태희;황종선;조용선;박형민;남긍현;이나영;최효상;임성훈;정동철;최명호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.101-102
    • /
    • 2006
  • We investigated the characteristics of flux-lock type superconducting fault current limiter (SFCL) by the fault cycles. Since the recovery characteristics of a superconducting element in the flux-lock type SFCL were dependent on the winding' direction between two coils, the analysis for the recovery characteristics of this type SFCL together with the current limiting characteristic is necessary to apply it to power system. As the fault cycles was increased from 1 cycle to 5 cycles, the initial limiting current ($I_{ini}$) and quench characteristic were mostly same. As the fault period increases, the recovery time of the superconducting element increases. The consumed energy and recovery characteristics in a superconducting element show the same tendency.

  • PDF

자기회로의 위상학적 상사성을 이용한 전류제한기 구조에 관한 연구 (The Research for a Structure of Current Limiter using a Phasic Similitude of Magnetic Circuit)

  • 지근양;민경일;이수원;장봉환;문영현
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2128-2135
    • /
    • 2009
  • In this paper, current limiter using a magnetic switching which is based on magnetic flux change in the case of fault is proposed. This current limiter consists of iron-core and three parts of coils. One is the primary coil connected to the power system. Another is the secondary coil wound to the opposite direction of the primary coil's winding. The other is the secondary of the secondary coil which is a movable copper plate winding and located below the secondary coil. In the normal state, the magnetic flux produced in the primary and secondary coils flows to the opposite directions each other and becomes to be canceled out. Therefore the voltages induced between the coils are zero. In the case of a fault, at the moment of a fault occurrence recognition, the switch connected to a secondary coil is opened and the secondary of the secondary coil is pulled out to the outside of the iron-core. Then, magnetic flux becomes to flow through the iron-core. Accordingly, the voltage is induced between the both ends of the primary coil and makes the current reduced. Therefore it is possible to cut off the circuit breaker easily with the proposed current limiter. This paper analyzes the current limiting effects and the detailed results are given.

양수발전소 동기전동기의 기동제어 알고리즘에 관한 연구 (A study developing control algorithm for Pumped-Storage Synchronous motor drive)

  • 강승우;박신현;김장목;임익헌;류호선;김진성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.467-471
    • /
    • 2003
  • The large synchronous motor for the pumped-storage plant(or SFC : Static Frequency Converter) has to be brought up to 100$\%$ rated speed and synchronized with the AC power network. Starting the motor from rest is achieved by switching current into the stator winding so that interaction between this stator current and the rotor flux will cause the correct direction of torque to be developed so that the motor turns in the required direction. Starting ranges of the synchronous motor are divided into three regions. The first region Is at standstill, the second that is called by the forced commutation is from standstill to 5-8$\%$ of rated speed, and the third, which is called by the natural commutation, is from 5-8$\%$ of rated speed to 100$\%$ rated speed. So this paper describes three regions of the control techniques of the pumped-storage synchronous motor drive.

  • PDF

Non-uniform wind environment in mountainous terrain and aerostatic stability of a bridge

  • Chen, Xingyu;Guo, Junjie;Tang, Haojun;Li, Yongle;Wang, Lei
    • Wind and Structures
    • /
    • 제30권6호
    • /
    • pp.649-662
    • /
    • 2020
  • The existence of a dam has potential effects on the surrounding wind environment especially when it is located in mountainous areas. In this situation, the long-span bridge over the reservoir can easily be exposed to non-uniform incoming flows, affecting its wind-resistance performance. This paper presents a study on the aerostatic stability of such a bridge. Wind tunnel tests were first carried out to investigate the wind environment above a mountainous reservoir. The results show that the angle of attack and the wind speed along the bridge axis show obvious non-uniform characteristics, which is related to the inflow direction. When winds come from the south where the river is winding, the angle of attack varies along the span direction significantly. The finite element model for the bridge was established using ANSYS software, and effects of non-uniform wind loads on the aerostatic stability were computed. Non-uniform angle of attack and wind speed are unfavorable to the aerostatic stability of the bridge, especially the former. When the combined action of non-uniform angle of attack and wind speed is considered, the critical wind speed of aerostatic instability is further reduced. Moreover, the aerostatic stability of the bridge is closely related to the dam height.

BLDC 모터의 열적 성능에 대한 설계 인자의 영향 (Effects of Design Parameters on the Thermal Performance of a Brushless DC Motor)

  • 김민수;이관수
    • 대한기계학회논문집B
    • /
    • 제32권2호
    • /
    • pp.141-148
    • /
    • 2008
  • A numerical simulation of brushless DC motor is performed to elucidate thermo-flow characteristics in winding and bearing with heat generation. Rotation of rotor and blades drives influx of ambient air into the rotor inlet. Recirculation zone exists in the tiny interfaces between windings. The flow separation causes poor cooling performance in bearing part and therefore the redesign of the bearing groove is required. The design parameters such as the inlet location, geometry and bearing groove threshold angle have been selected in the present simulation. As the inlet location moves inward in the radial direction, total incoming flow rate and heat transfer rate are increased. Total incoming flow rate is increased with increasing the inlet inner length. The effect of the bearing groove threshold angle on the thermal performance is less than that of other design parameters.

충돌 예상 시나리오에 따른 모터 구동형 리트랙터의 잠김 작용 평가 (Evaluation of Motorized retractor locking mechanism based on predetermined collision scenarios)

  • 박재순;국민구;김대희;탁태오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.903-908
    • /
    • 2007
  • A retractor is the major component of a seatbelt system that restraints passengers by locking the movement of webbing. Recently, in order to increase the effectiveness of seatbelt systems, motorized retractors that remove slack and correct passenger posture just before airbag expansion when collision is predicted are widely used. Key component of motorized retractors is the one-way clutch that engages and disengages the winding action of webbing according to the direction of motor revolution. Analytical investigation of action of the one-way clutch mechanism has been carried out to figure out conditions for one-way locking, and to study the effect of various kinematic and dynamic design variables of one-way clutch. Using combination of ADAMS and LifeMOD soft-wares, dynamic simulation of operation of motorized retractors including Hybrid-III dummy model has been carried out to evaluate the performance of the motorized retractors in various crash scenarios.

  • PDF

3차원 적분법을 이용한 변류기의 누설 자계 및 누설 인덕턴스 해석 (Analyses of Leakage Magnetic Field and Leakage Inductance in Current Transformers by 3-D Integral Methods)

  • 이희갑;박용필;이준웅;박우현;이기식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.503-506
    • /
    • 2001
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL3, it confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances L$\sub$r1/ and L$\sub$R2/ of the primary and secondary windings were calculated, their values are 4.23 mH and 0.49 mH, respectively. They are also similar to the measured values of the leakage inductances for the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

직동식 공압서보밸브의 Force Motor 설계 및 성능시험 (Design and Performance Test of the Force Motor for Direct Drive-type Pneumatic Servo Valve)

  • 이원희;김동수;박상운
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.836-839
    • /
    • 2003
  • A pneumatic servo valve which is widely applied in industrial field. And It is consist of force motor, spool & sleeve and servo controller. In this study. we developed the force motor which is consume to low power for a pneumatic servo valve. We could reduce the number of turn of the solenoid by using ferromagnetic permanent magnet and took different direction of each other using one coil instead of two coil. we modeled a system consisting of various electro-mechanical subsystems. The appropriateness of the model was verified by simulation. The simulation model resolved the motion of spool, the winding current and the magnetic force. Also, we calculated the displacement and velocity of the spool, flux contour line, b vector. flux density. flux linkage, back EMF etc.

  • PDF

대용량 알터네이터의 코일덮개 설계 (Structural Design of a Coil Cover for High Capacity Alternator)

  • 김대원;김종수
    • 한국정밀공학회지
    • /
    • 제19권3호
    • /
    • pp.46-51
    • /
    • 2002
  • Recently, High capacity alternator are used fur some special equipments in industry. But, several serious problem are occured, especially, broken coil of rotor, caused by crash with stator on rotating the rotor. Although added coil cover thor protect coil of rotor, coil cover is broken. In this study purpose 2 step for corrected that problems. First, three dimensional finite element method far investigate what is most important point. For that purpose, performed stress analysis of coil and coil cover that modeling and finite analysis by ANSYS software. Second, Apply prestress when winding the coil on stator to modify direction of net force. Vector analysis is used for determine corrected prestress. Result of the analysis and prestress are reviewed.