• 제목/요약/키워드: Winding Analysis

검색결과 801건 처리시간 0.031초

대형 화력 발전용 발전기 권선단부의 전자기력에 의한 진동 해석 (Vibration Analysis of the End-winding of Large Generator for Fossil Power Plant under Electromagnetic Excitation)

  • 김철홍;주영호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.350-355
    • /
    • 2003
  • This paper presents results of vibration analysis of a end-winding of large generator for fossil power plant. A finite element analysis using a commercial S/W is performed to calculate alternating electromagnetic forces, mainly of 120㎐ in 60㎐ machines, acting on the end-winding, and then to calculate forced response of the end-winding under electromagnetic forces. Also, this paper presents analytical and experimental modal analysis results of generator end-winding to validate FE model. We calculated forced response of end-winding on 120㎐, double rotating frequency. These results will be used to evaluate structural reliability of end-winding and applied to update model.

  • PDF

Winding function theory를 이용한 flux switching motor의 토크 계산 (Torque Calculation of Flux Switching Motor by Winding Function Theory)

  • 김재곤;박한석;우경일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.478-482
    • /
    • 2015
  • 본 논문에서는 winding function이론을 이용하여 플럭스 스위칭 전동기의 토크 계산에 대하여 기술하였다. 먼저 플럭스 스위칭 전동기의 토크 리플을 줄이기 위하여 기존의 전동기 모델에서 회전자 형상을 최적화한 새로운 플럭스 스위칭 전동기를 제시였고, 유한요소해석을 통하여 최적화된 전동기의 토크 리플의 감소를 확인하였다. 그리고 Winding function 이론을 이용한 시뮬레이션 결과와 유한요소해석 결과를 비교 검토하였다. 또한 최적화된 플럭스 스위칭 전동기와 구동 실험 장치를 제작하였고, winding function 이론을 이용한 토크 특성 해석 결과와 실험결과를 비교한 결과로부터 winding function 이론을 이용한 해석 방법의 가능성을 확인하였다.

500MW 급 대형 발전기 권선단부의 전자기력과 동특성 해석 (Analysis of Vibration and Electromagnetic Forces on a Generator End-winding for 500 MW Fossil Power Plant)

  • 김철홍;주영호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.826-831
    • /
    • 2001
  • Electromagnetic forces generate vibrations in the end-winding of large generators. A finite element analysis using a commercial S/W is performed to calculate electromagnetic force of end-winding in two pole generator for 500 MW fossil power plant. Also, this paper presents analytical and experimental modal analysis results of generator end- winding. Using validated FE model, 3D electromagnetic model which computes the forces on the end-winding is coupled with a 3D mechanical model which calculates the dynamic displacement and stress under electromagnetic forces. These results will be used to evaluate reliability of end-winding and applied to update model.

  • PDF

긴고정자 상집중권 선형 동기 전동기의 설계 및 특성 해석 (Design and Characteristics Analysis on Linear Synchronous Motor with Long Stator and Phase Concentrated Winding)

  • 김정만;조한욱;장석명;조정민;한영재
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.54-62
    • /
    • 2014
  • This study deals with the design and characteristics analysis on a linear synchronous motor (LSM) with a long stator and phase concentrated winding (PCW) to apply for a propulsion system such as a roller coaster for leisure facilities. First of all, the required propulsion force of LSM is computed and its design with double sided permanent magnets (PMs) and a phase concentrated winding is processed. The phase concentrated winding is composed of a module with each A, B, and C phase unlike an conventional concentrated winding (CW). It has an advantage of the installation and manufacture, compared to the conventional concentrated winding in the propulsion system for leisure facilities that have a long acceleration area and stator configuration placed on rail continuously. Thus, the design for the propulsion system and characteristics comparison between the phase concentrated winding and concentrated winding are carried out in this paper. Also, the analysis on dynamic characteristics is conducted to confirm the performance at operation.

고주파 트랜스포머의 권선배열에 기법 따른 손실해석 (Power Loss Analysis according to Winding Array Method of High Frequency Transformer)

  • 윤신용;김일남
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.15-19
    • /
    • 2005
  • This paper analyzed the power loss characteristics according to winding thickness and winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM tool. The ferrite core model for analysis be used the EE10 type of TDK cop.. Transformer model objected flyback transformer type applied to flyback converter/inverter. Therefore, analysis results of loss were obtained from inner parameters of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

Backstepping Control for Multi-Machine Web Winding System

  • Bouchiba, Bousmaha;Hazzab, Abdeldjebar;Glaoui, Hachemi;Med-Karim, Fellah;Bousserhane, Ismail Khalil;Sicard, Pierre
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.59-66
    • /
    • 2011
  • This work treat the modeling and simulation of non-linear dynamic behavior of a web winding process during traction. We designate by a winding process any system applying the cycles of unwinding, transport, treatment, and winding to various flat products. This system knows several constraints, such as the thermal effects caused by the frictions, and the mechanical effects provoked by metal elongation, that generates dysfunctions due to the influence of the process conditions. Several controllers are considered, including Proportional-integral (PI) and Backstepping control. This paper presents the study of Backstepping controls strategy of the winding system. Our winding system is simulated in MATLAB SIMULINK environment, the results obtained illustrate the efficiency of the proposed control with no overshoot, and the rising time is improved with good disturbances rejections comparing with the classical control law.

Effect of Winding Configuration on the kVA Rating of Wye-connected Autotransformer Applied to 12- pulse Rectifier

  • Meng, Fangang;Du, Qingxiao;Gao, Lei;Li, Quanhui;Man, Zhongcheng
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.463-474
    • /
    • 2019
  • This paper presents the effect of winding configuration on the kVA rating of a wye-connected autotransformer applied to a 12-pulse rectifier. To describe the winding configuration of the wye-connected autotransformer, position and proportional parameters are defined and their quantitative relation is calculated. The voltages across and currents through the windings are measured under different winding connections. Consequently, a relation between the kVA rating and position parameter is established in accordance with the analysis, and the optimal winding configuration is obtained on the basis of this relation. A wye-connected autotransformer with the least equivalent kVA rating and simplest winding configuration is designed and applied to the 12-pulse rectifier. Simulations and experiments are conducted to validate the theoretical analysis.

커패시터 구동형 단상유도전동기의 권선설계에 대한 연구 (A Study of Winding Design for Capacitor Run Single phase Induction Motor)

  • 함상환;임종빈;이주
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.776-780
    • /
    • 2011
  • This paper is concerned with winding design in capacitor-run single phase motor. Winding design in single phase induction motor is more complicated than that in three phase induction motor, because of using concentric winding in the single phase. Various winding designs are possible, and accordingly layout of the slot is calculated by formula. And then accurate design of winding is available. Using the design process in this paper, we can get the base model with slot layout and turns of windings of 1.12 kW single phase induction motor, and it is verified by finite element analysis. In this paper, winding design and winding layout of single-phase induction motor using concentric winding are suggested.

Back EMF Design of an AFPM Motor using PCB Winding by Quasi 3D Space Harmonic Analysis Method

  • Jang, Dae-Kyu;Chang, Jung-Hwan;Jang, Gun-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.730-735
    • /
    • 2012
  • This paper presents a method to design the waveform of a back electromotive force (back EMF) of an axial flux permanent magnet (AFPM) motor using printed circuit board (PCB) windings. When the magnetization distribution of permanent magnet (PM) is given, the magnetic field in the air gap region is calculated by the quasi three dimensional (3D) space harmonic analysis (SHA) method. Once the flux density distribution in the winding region is determined, the required shape of the back EMF can be obtained by adjusting the winding distribution. This can be done by modifying the distance between patterns of PCB to control the harmonics in the winding distribution. The proposed method is verified by finite element analysis (FEA) results and it shows the usefulness of the method in eliminating a specific harmonic component in the back EMF waveform of a motor.

Winding Function 이론을 이용한 동기형 릴럭턴스 전동기의 토크 특성 해석 (Torque Characteristics Analysis of Synchronous Reluctance Motor by Winding Function Theory)

  • 우경일
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.26-31
    • /
    • 2011
  • In this paper, torque characteristics analysis of Synchronous Reluctance Motor with the cylindrical rotor type by winding function theory(WFT) is described. The stator is same as one of the induction motor. From the d-axis, q-axis flux density distribution, to calculate self and mutual inductances needed to calculate the torque of the machine by using winding function theory the new equivalent geometry of rotor was proposed. D-axis, q-axis flux densities, self inductance and torque characteristics were obtained. From the comparison with results of finite element analysis the proposed method was verified.