• Title/Summary/Keyword: Wind turbine system

Search Result 994, Processing Time 0.037 seconds

An Investigation on Step Responses of Pitch PI Controller for a 2MW Wind Turbine Using Bladed S/W (Bladed S/W를 이용한 2MW급 풍력터빈에 대한 피치 PI 제어기의 계단응답 고찰)

  • Lim, Chae Wook
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.59-64
    • /
    • 2015
  • The pitch control system in wind turbines becomes more and more important as the wind turbines are larger in multi-MW size. PI controller has been applied in most pitch controllers and it has been known that gain-scheduling is essential for pitch control of wind turbines. A demo model of 2 MW wind turbine which represents the whole dynamics of wind turbine including dynamic behaviors of blade, tower and rotational shaft is given in the commercial Bladed S/W for real wind turbines. In this paper, some results on step responses of the pitch PI controller and effectiveness of gain-scheduled pitch PI controller are presented through the Bladed S/W for the 2 MW wind turbine.

Condition Monitoring System of Wind Turbine (풍력발전기를 위한 상태 모니터링 기술)

  • Hameed, Z.;Hong, Y.S.;Ahn, S.H.;Cho, Y.M.;Song, C.K.;Park, Jong-Po
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.395-399
    • /
    • 2007
  • Renewable energy sources such as wind energy is copiously available without any limitation. Wind turbines are used to tap the potential of wind energy which is available in millions of megawatt. Reliability of wind turbine is critical to extract this maximum amount of energy from the wind. We reviewed different techniques, methodologies, and algorithms developed to monitor the performance of wind turbine as well as for an early fault detection to keep away the wind turbines from catastrophic conditions due to sudden breakdowns. To keep the wind turbine in operation, implementation of Condition Monitoring System (CMS) is paramount, and for this purpose ample knowledge of these types of system is mandatory. So, an attempt has been made in this direction to review maximum approaches related to CMS in this piece of writing.

  • PDF

CCT Analysis of Power System Connected to DFIG Wind Turbine (DFIG 풍력터빈이 연계된 전력계통의 CCT 영향분석)

  • Seo, Gyu-Seok;Park, Ji-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2388-2392
    • /
    • 2013
  • Wind generation systems are very different in nature from conventional generation systems. Therefore it is necessary to research dynamic characteristics of wind generation systems connected to a power system. The stability analysis of wind turbine generator is an important issue in the operation of the power system. The result of angular stability of the power system that consists of only synchronous generators is different from that of the power system including wind turbine generators. This is due to the fact that generators connected to wind turbines are generally induction generators. The angular stability assessing synchronization of generators is determined by its corresponding critical clearing time(CCT). Wind turbine models for the analysis of power system are varied and difficult to use, but now these are standardized into four types. In this paper, the analysis of the CCT of the power system connected to wind farm considering the location and capacity is performed by using DFIG(Doubly-Fed induction Generator) wind turbine built-in type3 model in PSS/E-32.

A Study of Accelerated Life Test Conditions for Yaw Drive of Wind Turbine (풍력 발전기용 요 드라이브의 가속수명시험 조건에 관한 연구)

  • Lee, Young-Bum;Kang, Bo-Sik
    • Journal of Applied Reliability
    • /
    • v.14 no.4
    • /
    • pp.213-219
    • /
    • 2014
  • Wind turbine, which is attracting part of the renewable energy and is researching continuously, is going to be large size for high efficiency. There is a yaw system rotating the nacelle, weighted about 600 tons, to be perpendicular with the wind direction blowing in the large wind turbine. The wind turbine is focusing on the reliability improvement because working environment effect is bigger than any other points and specially, the reliability improvement of the yaw drive is required by the customer because it is the key component of the wind turbine. Because of this, the establishment of criteria for yaw drive is required because yaw drive system is the part of the wind turbine closely related with ensuring the reliability. So, this study did the failure analysis of the yaw drive system, which is consisted with 10 sets of yaw drives through researching and analyzing the site conditions. Also this study designed the life test method based on the failure analysis and working condition of the yaw drive. To design the accelerated life test of the yaw drive, this study reviewed the torque, lubrication condition, and frequency of use and etc. Finally, this selected the torque as the acceleration factor which is affected mainly to the system and also, the test equipment was developed based on the requirement of the life and performance test.

A Study on the Probabilistic Reliability Evaluation of Power System Considering Wind Turbine Generators with A simplified Multi-state Model (간략화한 다개상태 모델을 갖는 풍력발전계통을 고려한 전력계통의 신뢰도평가에 관한 기초연구)

  • Wu, Liang;Park, Jeong-Je;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.271-272
    • /
    • 2008
  • Renewable energy resources such as wind, wave, solar, micro hydro, tidal and biomass etc are becoming important stage by stage, considering the effect of environment. Wind energy is one of the most successful sources of renewable energy for the production of electrical energy. What's more, due to wind speed random variation the wind turbine generators can not make two-state model as conventional generators. The method of obtaining reliability evaluation indices of wind turbine generators is different from the conventional generators. This paper presents a study on the reliability evaluation of power system considering wind turbine generators with a simplified multi-state model.

  • PDF

Characteristics of Fatigue Load in a Wind Turbine by the Wake (후류에 의한 풍력터빈의 피로하중 특성)

  • Kim, Chung-Ok;Eum, Hark-Jin;Nam, Hyun-Woo;Kim, Gui-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.57-65
    • /
    • 2011
  • The wake generated by a wind turbine has an effect on performance of a downstream wind turbine as well as mechanical loads. This paper investigated characteristics of fatigue load at the blade root due to the wake effects and quantitatively analyzed its effects at operating condition of a 5MW tripod offshore wind turbine using Bladed 4.1 software. The wake effects was studied the way the wake's center position move from the rotor center to the blade tip to the far-away position where the wake doesn't affect the wind turbine. When wake's center was located on the blade tip or the rotor center, damage equivalent fatigue load was higher than other positions. It was up to 10~14% compared to those of non-wake case. Results of this study would be helpful to design wind turbines and wind farms to have lifetimes more than 20 years of the wind turbine.

The study of load measurement on U50 wind turbine (U50 풍력발전기 하중측정 실증연구)

  • Cho, Joo-Suk;Hong, Hyeok-Soo;Bang, Jo-Hyug;Park, Jin-Il;Ryu, Ji-Yune
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.114-122
    • /
    • 2007
  • This paper addresses the measurement of structural loads on the Unison U50 wind turbine. The load measurement are carried out to determine the actual loads acting on a wind turbine. This is needed not only the certification process but also improving the technical development for prototype wind turbine. The measurement system is consists of measuring load, operating quantities and meteorological signal. All data that occur during the operating of a WT are stored the data acquisition system automatically. With using the measured data, load spectrum and equivalent load are evaluated according to IEC61400-13 "Measurement of mechanical loads".

  • PDF

The study of load measurement on U50 wind turbine (U50 풍력발전기 하중측정 실증연구)

  • Cho, Joo-Suk;Hong, Hyeok-Soo;Bang, Jo-Hyug;Park, Jin-Il;Ryu, Ji-Yune;Gil, Kye-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.341-344
    • /
    • 2007
  • This paper addresses the measurement of structural loads on the Unison U50 wind turbine. The load measurement are carried out to determine the actual loads acting on a wind turbine. This is needed not only the certification process but also improving the technical development for prototype wind turbine. The measurement system is consists of measuring load, operating quantities and meteorological signal. All data that occur during the operating of a WT are stored the data acquisition system automatically. With using the measured data, load spectrum and equivalent load are evaluated according to IEC61400-13 "Measurement of mechanical loads".

  • PDF

750kW Gearless Type Wind Turbine Generator System (750kW급 Gearless형 국산화 풍력발전시스템)

  • Ryu, Ji-Yoon;Park, Jin-Il;Kim, Dae-Hyun;Hwang, Jin-Su;Kim, Doo-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.245-248
    • /
    • 2006
  • The first of korean 750kW gearless type wind turbine is developed. The wind turbine is designed, manufactured and tested by GE regulation and obtained the design certificate by GL. And the performance test is being performed at the demonstration site now. This paper presents the history of development and performance test for 750kW gearless type wind turbine.

  • PDF

Effects of Design Parameters on the Frictional Coefficient of Clamping Pads for Self-Climbing Crane systems (자력 승강식 크레인의 클램핑 패드 마찰계수에 미치는 설계변수 영향)

  • Sang-Hyun Park;Su-Min Lee;Youngjae Yu;Sang-Rai Cho
    • Journal of Wind Energy
    • /
    • v.14 no.4
    • /
    • pp.13-20
    • /
    • 2023
  • A self-climbing crane (SCC) system is under development for the installation and maintenance of wind turbines. It can move vertically along the wind turbine tower by itself. One of the key components of the SCC system is the clamping pad to maintain a safe position on the wind turbine tower. The SCC system can maintain its position on the tower from the frictional force generated between the surfaces of the clamping pads and the tower. If the frictional force provided by the clamping pads are insufficient, the SCC system cannot stay in the vertical position on the tower. Therefore, the development of clamping pads with sufficient frictional force is very important for the SCC system. At the same time, the operation of the SCC system should not damage the paint coating of the wind turbine tower. In order to verify that the frictional force is sufficient and that frictional and compressive forces do not cause damage to the paint, a number of combined compression and shear loading tests were conducted using a test device prepared for this study. The details regarding the test specimens, test procedure, and test results are summarized in this paper.